Retest stability of the communication profile for the hearing impaired.

Abstract:

:Retest stability of the Communication Profile for the Hearing Impaired (CPHI) was assessed in a sample of 101 active-duty military personnel who attended the Aural Rehabilitation Program at Walter Reed Army Medical Center. Pretests were administered by referring audiologists; retests were administered from 6 to 40 weeks later, at the beginning of the rehabilitation program. Mean scores on 5 of the 25 scales of the CPHI decreased significantly (p less than 0.01) over time, but the changes were small in magnitude (approximately -0.20). Distributions of retest-test differences were used to establish criteria for inferring significant improvement in scores over time. Retest correlations for scales in the communication environment, communication strategies, and personal adjustment areas ranged from 0.58 to 0.78. Communication performance and communication importance were less stable (r = 0.28 to 0.54). Retest correlations were comparable for short versus long retest intervals, but varied as a function of military rank. Implications of the results for clinical use of the CPHI are discussed.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Demorest ME,Erdman SA

doi

10.1097/00003446-198810000-00002

subject

Has Abstract

pub_date

1988-10-01 00:00:00

pages

237-42

issue

5

eissn

0196-0202

issn

1538-4667

journal_volume

9

pub_type

杂志文章
  • Sensory-Cognitive Interactions in Older Adults.

    abstract::The objective of this study was regarding sensory and cognitive interactions in older adults published since 2009, the approximate date of the most recent reviews on this topic. After an electronic database search of articles published in English since 2009 on measures of hearing and cognition or vision and cognition ...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0000000000000303

    authors: Humes LE,Young LA

    更新日期:2016-07-01 00:00:00

  • The statistical basis for serial monitoring in audiology.

    abstract:OBJECTIVES:Audiologists regularly use serial monitoring to evaluate changes in a patient's auditory function over time. Observed changes are compared with reference standards to determine whether further clinical action is necessary. Reference standards are established in a control sample of otherwise healthy subjects ...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e31828a21b3

    authors: McMillan GP,Reavis KM,Konrad-Martin D,Dille MF

    更新日期:2013-09-01 00:00:00

  • Head Movements Allow Listeners Bilaterally Implanted With Cochlear Implants to Resolve Front-Back Confusions.

    abstract:OBJECTIVES:We report on the ability of patients fit with bilateral cochlear implants (CIs) to distinguish the front-back location of sound sources both with and without head movements. At issue was (i) whether CI patients are more prone to front-back confusions than normal hearing listeners for wideband, high-frequency...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000581

    authors: Pastore MT,Natale SJ,Yost WA,Dorman MF

    更新日期:2018-11-01 00:00:00

  • Comparison of the Motor Performance and Vestibular Function in Infants with a Congenital Cytomegalovirus Infection or a Connexin 26 Mutation: A Preliminary Study.

    abstract:OBJECTIVES:Hearing-impaired children are at risk for vestibular damage and delayed motor development. Two major causes of congenital hearing loss are cytomegalovirus (CMV) infection and connexin (Cx) 26 mutations. Comparison of the motor performance and vestibular function between these specific groups is still underex...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000364

    authors: Maes L,De Kegel A,Van Waelvelde H,De Leenheer E,Van Hoecke H,Goderis J,Dhooge I

    更新日期:2017-01-01 00:00:00

  • Effects of Phantom Electrode Stimulation on Vocal Production in Cochlear Implant Users.

    abstract:OBJECTIVES:Cochlear implant (CI) users suffer from a range of speech impairments, such as stuttering and vocal control of pitch and intensity. Though little research has focused on the role of auditory feedback in the speech of CI users, these speech impairments could be due in part to limited access to low-frequency c...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000690

    authors: Caldwell MT,Jiradejvong P,Limb CJ

    更新日期:2019-09-01 00:00:00

  • Design and function: a physical and electrical description of the 3M House cochlear implant system.

    abstract::A patient-wearable, single-electrode cochlear implant was first used by a patient in 1972 at the House Ear Institute. Since early 1982, a redesigned version of this system has been in clinical use. This new system, called the 3M House cochlear implant system, consists of an implanted receiver and a patient-worn signal...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:

    authors: Fretz RJ,Fravel RP

    更新日期:1985-05-01 00:00:00

  • Noise-induced otoacoustic emission loss with or without hearing loss.

    abstract::The association between audiometric hearing thresholds and click-evoked otoacoustic emission (CEOAE) spectral properties was examined in 129 adult subjects with and without a noise-induced hearing loss (NIHL). Subjects were grouped according to their "beginning of hearing loss frequency" and their exposure to hazardou...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199512000-00007

    authors: Attias J,Furst M,Furman V,Reshef I,Horowitz G,Bresloff I

    更新日期:1995-12-01 00:00:00

  • Measurement of individual loudness functions by trisection of loudness ranges.

    abstract:OBJECTIVES:Loudness-balance measurements with monaurally impaired subjects have shown that the shape of the loudness versus sound-pressure curve among hearing-impaired persons varies significantly. But the effectiveness of adjusting the compression characteristics of wide-dynamic-range compression hearing aids-the comp...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e318177d9c6

    authors: Villchur E,Killion MC

    更新日期:2008-10-01 00:00:00

  • Systematic Review on Late Cochlear Implantation in Early-Deafened Adults and Adolescents: Predictors of Performance.

    abstract:OBJECTIVES:Early-deafened, late-implanted adolescents and adults constitute a unique group of cochlear implant (CI) users, showing a large variability in outcomes. The current systematic review aimed to determine which preimplantation factors are relevant in predicting postoperative outcomes in this patient group. DES...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000889

    authors: Debruyne JA,Janssen AM,Brokx JPL

    更新日期:2020-11-01 00:00:00

  • Middle ear dynamic characteristics in patients with otosclerosis.

    abstract:OBJECTIVE:To investigate the middle ear dynamic characteristics in patients with otosclerosis using the sweep frequency impedance meter (SFI test) and conventional tympanometry, and also to evaluate the diagnostic efficiency of the SFI test for otosclerosis. DESIGN:The study was designed to collect a total of 25 (36 e...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200204000-00007

    authors: Zhao F,Wada H,Koike T,Ohyama K,Kawase T,Stephens D

    更新日期:2002-04-01 00:00:00

  • Analog model of human click-elicited SP and effects of high-pass filtering.

    abstract::Recent advances in electrode design have helped to rekindle clinical interests in noninvasive electrocochleography--to enhance auditory brain stem response (ABR) recordings (namely, wave I) and to screen Meniere's disease. The salient feature of the response in suspected cases of endolymphatic hydrops is an unusually ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199104000-00011

    authors: Durrant JD,Ferraro JA

    更新日期:1991-04-01 00:00:00

  • Strategies for infant auditory brain stem response assessment.

    abstract::The use of auditory brain stem response (ABR) represents a new dimension in auditory and neurological pediatric assessment. Because the ABR may be altered by stimulus and procedural variables, the lack of an established standard has reduced its clinical efficiency. This paper describes a suggested ABR protocol for inf...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198209000-00006

    authors: Jacobson JT,Morehouse CR,Johnson MJ

    更新日期:1982-09-01 00:00:00

  • Linguistic input, electronic media, and communication outcomes of toddlers with hearing loss.

    abstract:OBJECTIVES:The objectives of this study were to examine the quantity of adult words, adult-child conversational turns, and electronic media in the auditory environments of toddlers who are hard of hearing (HH) and to examine whether these factors contributed to variability in children's communication outcomes. DESIGN:...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3182a76768

    authors: Ambrose SE,VanDam M,Moeller MP

    更新日期:2014-03-01 00:00:00

  • A Cross-Language Comparison of Sentence Recognition Using American English and Mandarin Chinese HINT and AzBio Sentences.

    abstract:OBJECTIVES:The aim of this study was to perform a cross-language comparison of two commonly used sentence-recognition materials (i.e., Hearing in Noise Test [HINT] and AzBio) in American English (AE) and Mandarin Chinese (MC). DESIGNS:Sixty normal-hearing, native English-speaking and 60 normal-hearing, native Chinese-...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000938

    authors: Xu L,Xi X,Patton A,Wang X,Qi B,Johnson L

    更新日期:2020-08-19 00:00:00

  • The risks of amplified music for disc-jockeys working in nightclubs.

    abstract:OBJECTIVES:Here, we evaluate the risks of amplified music for disc-jockeys (DJs) working in nightclubs. DESIGN:Sound level measurements were performed within the DJ mixing booths. A questionnaire was used to obtain exposure to noise and length of time in the profession. Audiograms and tinnitus pitch matching was also ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31819769fc

    authors: Potier M,Hoquet C,Lloyd R,Nicolas-Puel C,Uziel A,Puel JL

    更新日期:2009-04-01 00:00:00

  • Status of school children's hearing aids relative to monitoring practices.

    abstract::Data concerning hearing aid monitoring practices and hearing aid malfunction were collected for three groups of mainstreamed hearing-impaired children: 248 children receiving services from itinerant teachers of the hearing impaired, 43 who participated in a study involving extensive psychoeducational evaluation, and 1...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/00003446-198808000-00007

    authors: Elfenbein JL,Bentler RA,Davis JM,Niebuhr DP

    更新日期:1988-08-01 00:00:00

  • Speech Recognition and Parent Ratings From Auditory Development Questionnaires in Children Who Are Hard of Hearing.

    abstract:OBJECTIVES:Progress has been made in recent years in the provision of amplification and early intervention for children who are hard of hearing. However, children who use hearing aids (HAs) may have inconsistent access to their auditory environment due to limitations in speech audibility through their HAs or limited HA...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000213

    authors: McCreery RW,Walker EA,Spratford M,Oleson J,Bentler R,Holte L,Roush P

    更新日期:2015-11-01 00:00:00

  • Effects of Head Movements on Sound-Source Localization in Single-Sided Deaf Patients With Their Cochlear Implant On Versus Off.

    abstract:OBJECTIVES:We investigated the ability of single-sided deaf listeners implanted with a cochlear implant (SSD-CI) to (1) determine the front-back and left-right location of sound sources presented from loudspeakers surrounding the listener and (2) use small head rotations to further improve their localization performanc...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000882

    authors: Pastore MT,Natale SJ,Clayton C,Dorman MF,Yost WA,Zhou Y

    更新日期:2020-11-01 00:00:00

  • Do hearing loss and cognitive function modulate benefit from different binaural noise-reduction settings?

    abstract:OBJECTIVES:Although previous research indicates that cognitive skills influence benefit from different types of hearing aid algorithms, comparatively little is known about the role of, and potential interaction with, hearing loss. This holds true especially for noise reduction (NR) processing. The purpose of the presen...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000003

    authors: Neher T,Grimm G,Hohmann V,Kollmeier B

    更新日期:2014-05-01 00:00:00

  • Air-Conducted Vestibular Evoked Myogenic Potential Testing in Children, Adolescents, and Young Adults: Thresholds, Frequency Tuning, and Effects of Sound Exposure.

    abstract:OBJECTIVES:Pediatric vestibular evaluations incorporate cervical and ocular vestibular evoked myogenic potential (c- and oVEMP, respectively) testing; however, in children, c- and oVEMP thresholds have been minimally investigated and frequency tuning is unknown. Children are also at risk for unsafe sound exposure secon...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000607

    authors: Rodriguez AI,Thomas MLA,Janky KL

    更新日期:2019-01-01 00:00:00

  • Judgments of hearing aid processed music.

    abstract::Paired comparison perception and preference judgments of hearing aid processed music were examined under conditions of extended and reduced high and low-frequency ranges. The performance of 20 subjects with mild to moderate hearing impairment was compared with an equal number of normal hearing controls. Subjects with ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198201000-00004

    authors: Franks JR

    更新日期:1982-01-01 00:00:00

  • Relationship between two dichotic listening tests and the Token test for children.

    abstract::The relationship between two dichotic listening tasks was studied. The two dichotic tests used were the Staggered Spondaic Word (SSW) test and the directed Dichotic Consonant-Vowel (CV) test. These measures were administered to 104 children between the ages of 6.0 and 8.0 yrs. The subjects were divided into two groups...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198311000-00003

    authors: Harris VL,Keith RW,Novak KK

    更新日期:1983-11-01 00:00:00

  • Single-channel versus bilateral multichannel cochlear implant results: a case report.

    abstract::Pre- and postoperative audiologic findings are compared in a patient who underwent three cochlear implant surgeries: an initial single-channel device in a recently deafened ear with no residual hearing, followed by a multichannel device in a congenitally deafened ear with a severe to profound loss, and subsequent expl...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199112000-00007

    authors: Pijl S

    更新日期:1991-12-01 00:00:00

  • Detectability of transient and sinusoidal otoacoustic emissions.

    abstract::An analysis is presented of the detectability of the two types of otoacoustic emissions being considered for use in clinical tests of hearing. It is estimated that, for equal emission levels and equal probability of error, measurement of distortion-product emissions can be made at least 30 times faster than transient-...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199210000-00008

    authors: Zurek PM

    更新日期:1992-10-01 00:00:00

  • Unilateral Hearing Loss: Understanding Speech Recognition and Localization Variability-Implications for Cochlear Implant Candidacy.

    abstract:OBJECTIVES:At a minimum, unilateral hearing loss (UHL) impairs sound localization ability and understanding speech in noisy environments, particularly if the loss is severe to profound. Accompanying the numerous negative consequences of UHL is considerable unexplained individual variability in the magnitude of its effe...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000380

    authors: Firszt JB,Reeder RM,Holden LK

    更新日期:2017-03-01 00:00:00

  • Auditory perception changes after reimplantation in a child cochlear implant user.

    abstract::The ability to remove cochlear implants from children and subsequently reimplant a more complex device in the same ear was the concern of this single case study. A postlinguistically deafened child, J.L., received a single-channel cochlear implant 1 yr after contracting meningitis and suffering a profound bilateral se...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199206000-00009

    authors: Chute PM,Hellman SA,Parisier SC,Tartter VC,Economou A

    更新日期:1992-06-01 00:00:00

  • The effect of hearing aid microphone mode on performance in an auditory orienting task.

    abstract:OBJECTIVES:Although directional microphones on a hearing aid provide a signal-to-noise ratio benefit in a noisy background, the amount of benefit is dependent on how close the signal of interest is to the front of the user. It is assumed that when the signal of interest is off-axis, users can reorient themselves to the...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000053

    authors: Brimijoin WO,Whitmer WM,McShefferty D,Akeroyd MA

    更新日期:2014-09-01 00:00:00

  • Longitudinal study of pure-tone thresholds in older persons.

    abstract:OBJECTIVE:Pure-tone thresholds for conventional and extended high frequencies were analyzed for 188 older adult human subjects (91 females, 97 males). The objectives were to study longitudinal changes in thresholds as well as the effects of initial threshold levels, age, gender, and noise history on these longitudinal ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200502000-00001

    authors: Lee FS,Matthews LJ,Dubno JR,Mills JH

    更新日期:2005-02-01 00:00:00

  • Speech perception using maps based on neural response telemetry measures.

    abstract:OBJECTIVE:To determine how speech perception is affected for Nucleus cochlear implant users when their speech processor is programmed using neural response telemetry (NRT) measures rather than traditional behavioral estimates of threshold and maximum comfort level. DESIGN:Electrically evoked compound action potential ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200202001-00009

    authors: Seyle K,Brown CJ

    更新日期:2002-02-01 00:00:00

  • Vestibular-evoked myogenic potential in the prediction of recovery from acute low-tone sensorineural hearing loss.

    abstract:OBJECTIVE:Click and galvanic stimulations of vestibular-evoked myogenic potential (c-VEMP and g-VEMP) were applied to measure the interaural difference (IAD) of saccular responses in patients with acute low-tone sensorineural hearing loss (ALHL). This study intended to explore the relationship between saccular asymmetr...

    journal_title:Ear and hearing

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/AUD.0b013e3181c5b743

    authors: Wang CT,Fang KM,Young YH,Cheng PW

    更新日期:2010-04-01 00:00:00