Effects of Phantom Electrode Stimulation on Vocal Production in Cochlear Implant Users.

Abstract:

OBJECTIVES:Cochlear implant (CI) users suffer from a range of speech impairments, such as stuttering and vocal control of pitch and intensity. Though little research has focused on the role of auditory feedback in the speech of CI users, these speech impairments could be due in part to limited access to low-frequency cues inherent in CI-mediated listening. Phantom electrode stimulation (PES) represents a novel application of current steering that extends access to low frequencies for CI recipients. It is important to note that PES transmits frequencies below 300 Hz, whereas Baseline does not. The objective of this study was to explore the effects of PES on multiple frequency-related characteristics of voice production. DESIGN:Eight postlingually deafened, adult Advanced Bionics CI users underwent a series of vocal production tests including Tone Repetition, Vowel Sound Production, Passage Reading, and Picture Description. Participants completed all of these tests twice: once with PES and once using their program used for everyday listening (Baseline). An additional test, Automatic Modulation, was included to measure acute effects of PES and was completed only once. This test involved switching between PES and Baseline at specific time intervals in real time as participants read a series of short sentences. Finally, a subjective Vocal Effort measurement was also included. RESULTS:In Tone Repetition, the fundamental frequencies (F0) of tones produced using PES and the size of musical intervals produced using PES were significantly more accurate (closer to the target) compared with Baseline in specific gender, target tone range, and target tone type testing conditions. In the Vowel Sound Production task, vowel formant profiles produced using PES were closer to that of the general population compared with those produced using Baseline. The Passage Reading and Picture Description task results suggest that PES reduces measures of pitch variability (F0 standard deviation and range) in natural speech production. No significant results were found in comparisons of PES and Baseline in the Automatic Modulation task nor in the Vocal Effort task. CONCLUSIONS:The findings of this study suggest that usage of PES increases accuracy of pitch matching in repeated sung tones and frequency intervals, possibly due to more accurate F0 representation. The results also suggest that PES partially normalizes the vowel formant profiles of select vowel sounds. PES seems to decrease pitch variability of natural speech and appears to have limited acute effects on natural speech production, though this finding may be due in part to paradigm limitations. On average, subjective ratings of vocal effort were unaffected by the usage of PES versus Baseline.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Caldwell MT,Jiradejvong P,Limb CJ

doi

10.1097/AUD.0000000000000690

subject

Has Abstract

pub_date

2019-09-01 00:00:00

pages

1127-1139

issue

5

eissn

0196-0202

issn

1538-4667

journal_volume

40

pub_type

杂志文章
  • Factors affecting sensitivity of distortion-product otoacoustic emissions to ototoxic hearing loss.

    abstract:OBJECTIVES:(1) To determine the ototoxicity detection rate (sensitivity) for distortion-product otoacoustic emissions (DPOAEs) testing in adults who received ototoxic medications and experienced pure-tone threshold changes during the course of treatment; (2) to determine the extent to which DPOAE sensitivity to ototoxi...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e318181ad99

    authors: Reavis KM,Phillips DS,Fausti SA,Gordon JS,Helt WJ,Wilmington D,Bratt GW,Konrad-Martin D

    更新日期:2008-12-01 00:00:00

  • Retest stability of the communication profile for the hearing impaired.

    abstract::Retest stability of the Communication Profile for the Hearing Impaired (CPHI) was assessed in a sample of 101 active-duty military personnel who attended the Aural Rehabilitation Program at Walter Reed Army Medical Center. Pretests were administered by referring audiologists; retests were administered from 6 to 40 wee...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198810000-00002

    authors: Demorest ME,Erdman SA

    更新日期:1988-10-01 00:00:00

  • A Cross-Language Comparison of Sentence Recognition Using American English and Mandarin Chinese HINT and AzBio Sentences.

    abstract:OBJECTIVES:The aim of this study was to perform a cross-language comparison of two commonly used sentence-recognition materials (i.e., Hearing in Noise Test [HINT] and AzBio) in American English (AE) and Mandarin Chinese (MC). DESIGNS:Sixty normal-hearing, native English-speaking and 60 normal-hearing, native Chinese-...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000938

    authors: Xu L,Xi X,Patton A,Wang X,Qi B,Johnson L

    更新日期:2020-08-19 00:00:00

  • Effect of peak clipping on speech recognition threshold.

    abstract::Speech recognition thresholds (SRTs) were measured for a closed set of spondees that had been processed by peak clipping and compression. Both hearing-impaired and normal-hearing subject groups showed progressively higher SRTs with increasing levels of peak clipping, with significant threshold shifts occurring for cli...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199412000-00005

    authors: Crain TR,Van Tasell DJ

    更新日期:1994-12-01 00:00:00

  • Noise-induced otoacoustic emission loss with or without hearing loss.

    abstract::The association between audiometric hearing thresholds and click-evoked otoacoustic emission (CEOAE) spectral properties was examined in 129 adult subjects with and without a noise-induced hearing loss (NIHL). Subjects were grouped according to their "beginning of hearing loss frequency" and their exposure to hazardou...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199512000-00007

    authors: Attias J,Furst M,Furman V,Reshef I,Horowitz G,Bresloff I

    更新日期:1995-12-01 00:00:00

  • Current state of knowledge: outcomes research in children with mild to severe hearing impairment--approaches and methodological considerations.

    abstract::This paper will provide a backdrop to the others in this section on outcomes of children with mild to moderate sensorineural hearing loss. Our objective here is to provide an overview of the research approaches used to study the outcomes of these children to provide guidance for future studies of children with mild to...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0b013e318157f093

    authors: Tomblin B,Hebbeler K

    更新日期:2007-12-01 00:00:00

  • Evaluation of Speed and Accuracy of Next-Generation Auditory Steady State Response and Auditory Brainstem Response Audiometry in Children With Normal Hearing and Hearing Loss.

    abstract:OBJECTIVES:The first objective of this study was to compare the predicted audiometric thresholds obtained by auditory steady state response (ASSR) and auditory brainstem response (ABR) in infants and toddlers when both techniques use optimal stimuli and detection algorithms. This information will aid in determining the...

    journal_title:Ear and hearing

    pub_type: 杂志文章,多中心研究

    doi:10.1097/AUD.0000000000000580

    authors: Sininger YS,Hunter LL,Hayes D,Roush PA,Uhler KM

    更新日期:2018-11-01 00:00:00

  • Hearing handicap ratings among different profiles of adult cochlear implant users.

    abstract:OBJECTIVE:The aim was to compare outcomes in the domain of self-reported hearing handicap across groups of patients fit with one versus two cochlear implants (CI, CI + CI), or with an implant and a hearing aid (HA) in the nonimplanted ear (CI + HA). DESIGN:The design was retrospective, and a preliminary step was to fa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31815d6da8

    authors: Noble W,Tyler R,Dunn C,Bhullar N

    更新日期:2008-01-01 00:00:00

  • Age-related asymmetry on a cued-listening task.

    abstract::We report results on a cued-listening task designed to simulate the listening problems commonly described by individuals with sensorineural hearing loss, especially those experienced by elderly persons. Against a background of multitalker babble, the subject detected targets embedded in continuous discourse. Noncohere...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199208000-00009

    authors: Jerger J,Jordan C

    更新日期:1992-08-01 00:00:00

  • Discriminating and responsiveness abilities of two hearing handicap scales.

    abstract::Several scales exist for screening handicap and assessing rehabilitation in elderly individuals with hearing loss. There are few comparative studies, however, to suggest which scales perform best. Using receiver-operating curves and responsiveness indices, we examined the relative discriminating ability and sensitivit...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199006000-00002

    authors: Mulrow CD,Tuley MR,Aguilar C

    更新日期:1990-06-01 00:00:00

  • Effects of interaural pitch matching and auditory image centering on binaural sensitivity in cochlear implant users.

    abstract:OBJECTIVES:In bilateral cochlear implant users, electrodes mapped to the same frequency range in each ear may stimulate different places in each cochlea due to an insertion depth difference of electrode arrays. This interaural place of stimulation mismatch can lead to problems with auditory image fusion and sensitivity...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000135

    authors: Kan A,Litovsky RY,Goupell MJ

    更新日期:2015-05-01 00:00:00

  • Audiologic findings in botulism poisoning.

    abstract::Botulism poisoning results in a presynaptic failure of neuromuscular transmission, and may be expected to impair Eustachian tube and stapedius reflex function. The audiologic findings in five normal-hearing patients with type A botulism poisoning are presented. Results were varied. Two patients demonstrated type B or ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199108000-00007

    authors: Pijl S

    更新日期:1991-08-01 00:00:00

  • Test-retest reliability of a distinctive feature difference test for hearing aid evaluation.

    abstract::A short closed-set test of speech discrimination using consonants frequently confused by the hearing impaired and scored on the basis of distinctive features was developed and examined for reliability. In experiment I the Distinctive Feature Difference (DFD) Test and the CID W-22 Test were low-pass filtered and presen...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198203000-00002

    authors: Feeney MP,Franks JR

    更新日期:1982-03-01 00:00:00

  • Immediate and Short-Term Therapeutic Results Between Direction-Changing Positional Nystagmus with Short- and Long-Duration Groups.

    abstract:OBJECTIVES:Clinicians sometimes treat patients with relatively long-duration geotropic direction-changing positional nystagmus (DCPN), without latency. Recently, the concept of a "light cupula" in the lateral canal that reveals persistent geotropic DCPN has been introduced. In the present study, we investigated the imm...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000232

    authors: Ban JH,Kim MB,Hong SM

    更新日期:2016-03-01 00:00:00

  • A systematic review of the nonacoustic benefits of bone-anchored hearing AIDS.

    abstract:OBJECTIVE:This study completed an evidence-based practice systematic review of the nonacoustic benefits for adult patients receiving bone-anchored hearing aid(s) (BAHAs) relative to other forms of amplification (i.e., none, bone-conduction hearing aids [BCHAs], or air-conduction hearing aids [ACHAs]). DESIGN:Systemati...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/01.aud.0000240635.70277.3f

    authors: Johnson CE,Danhauer JL,Reith AC,Latiolais LN

    更新日期:2006-12-01 00:00:00

  • Design and function: a physical and electrical description of the 3M House cochlear implant system.

    abstract::A patient-wearable, single-electrode cochlear implant was first used by a patient in 1972 at the House Ear Institute. Since early 1982, a redesigned version of this system has been in clinical use. This new system, called the 3M House cochlear implant system, consists of an implanted receiver and a patient-worn signal...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:

    authors: Fretz RJ,Fravel RP

    更新日期:1985-05-01 00:00:00

  • The Benefits of Increased Sensation Level and Bandwidth for Spatial Release From Masking.

    abstract:OBJECTIVE:Spatial release from masking (SRM) can increase speech intelligibility in complex listening environments. The goal of the present study was to document how speech-in-speech stimuli could be best processed to encourage optimum SRM for listeners who represent a range of ages and amounts of hearing loss. We exam...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000352

    authors: Jakien KM,Kampel SD,Gordon SY,Gallun FJ

    更新日期:2017-01-01 00:00:00

  • Interleaved Processors Improve Cochlear Implant Patients' Spectral Resolution.

    abstract:OBJECTIVE:Cochlear implant patients have difficulty in noisy environments, in part, because of channel interaction. Interleaving the signal by sending every other channel to the opposite ear has the potential to reduce channel interaction by increasing the space between channels in each ear. Interleaving still potentia...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000249

    authors: Aronoff JM,Stelmach J,Padilla M,Landsberger DM

    更新日期:2016-03-01 00:00:00

  • Description and primary results from an audiometric study of male twins.

    abstract:OBJECTIVE:The purpose of this study is to present descriptive results from an audiometric examination of a male twin sample, compare the values with normative databases, and explore whether there are age differences in genetic and environmental contributions to variation in hearing. DESIGN:Audiometric and questionnair...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199704000-00003

    authors: Karlsson KK,Harris JR,Svartengren M

    更新日期:1997-04-01 00:00:00

  • A screening procedure for modified simplex in frequency-gain response selection.

    abstract::The preference for hearing aid frequency-gain responses selected using the modified simplex procedure over that prescribed by NAL-R is not universal. A screening protocol used before individualized fitting may help streamline its use and ensure effective use of clinical time. In this protocol, listeners compare the pr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199402000-00007

    authors: Kuk FK

    更新日期:1994-02-01 00:00:00

  • Reinforced active middle ear implant fixation in incus vibroplasty.

    abstract:OBJECTIVES:The active middle ear implant Vibrant Soundbridge® was originally designed to treat mild-to-severe sensorineural hearing losses. The floating mass transducer (FMT) is crimped onto the long incus process. The procedure is termed incus vibroplasty to distinguish from other attachment sites or stimulus modi for...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000078

    authors: Mlynski R,Dalhoff E,Heyd A,Wildenstein D,Hagen R,Gummer AW,Schraven SP

    更新日期:2015-01-01 00:00:00

  • Comparison of real-ear to coupler difference values in the right and left ear of adults using three earmold configurations.

    abstract:OBJECTIVE:The purpose of the study was to compare real-ear to coupler difference (RECD) values in the right and left ear of adults using three earmold configurations. DESIGN:The RECD was obtained from both ears of 18 normal hearing adults by subtracting the HA2 2-cc coupler response from the real-ear response using an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200506000-00005

    authors: Munro KJ,Buttfield LM

    更新日期:2005-06-01 00:00:00

  • Transcutaneous vagus nerve stimulation modulates tinnitus-related beta- and gamma-band activity.

    abstract:OBJECTIVES:The ability of a treatment method to interfere with tinnitus-related neural activity patterns, such as cortical gamma rhythms, has been suggested to indicate its potential in relieving tinnitus. Therapeutic modulation of gamma-band oscillations with vagus nerve stimulation has been recently reported in epile...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0000000000000123

    authors: Hyvärinen P,Yrttiaho S,Lehtimäki J,Ilmoniemi RJ,Mäkitie A,Ylikoski J,Mäkelä JP,Aarnisalo AA

    更新日期:2015-05-01 00:00:00

  • Top-Down Processes in Simulated Electric-Acoustic Hearing: The Effect of Linguistic Context on Bimodal Benefit for Temporally Interrupted Speech.

    abstract:OBJECTIVES:Previous studies have documented the benefits of bimodal hearing as compared with a cochlear implant alone, but most have focused on the importance of bottom-up, low-frequency cues. The purpose of the present study was to evaluate the role of top-down processing in bimodal hearing by measuring the effect of ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000298

    authors: Oh SH,Donaldson GS,Kong YY

    更新日期:2016-09-01 00:00:00

  • Deterioration of Speech Recognition Ability Over a Period of 5 Years in Adults Ages 18 to 70 Years: Results of the Dutch Online Speech-in-Noise Test.

    abstract:OBJECTIVES:The first aim of the present study was to determine the change in speech recognition in noise over a period of 5 years in participants ages 18 to 70 years at baseline. The second aim was to investigate whether age, gender, educational level, the level of initial speech recognition in noise, and reported chro...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000134

    authors: Stam M,Smits C,Twisk JW,Lemke U,Festen JM,Kramer SE

    更新日期:2015-05-01 00:00:00

  • Pitfalls in neurotologic diagnosis.

    abstract::Several cases illustrating potential pitfalls in neurotologic diagnosis from the viewpoint of the otologist are presented. The role of auditory brain stem response testing is specifically emphasized in cases with discordant audiologic and radiographic findings. Included are one case of a "false negative" ABR in a pati...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198804000-00007

    authors: Telian SA,Kileny PR

    更新日期:1988-04-01 00:00:00

  • Detectability of transient and sinusoidal otoacoustic emissions.

    abstract::An analysis is presented of the detectability of the two types of otoacoustic emissions being considered for use in clinical tests of hearing. It is estimated that, for equal emission levels and equal probability of error, measurement of distortion-product emissions can be made at least 30 times faster than transient-...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199210000-00008

    authors: Zurek PM

    更新日期:1992-10-01 00:00:00

  • Analog model of human click-elicited SP and effects of high-pass filtering.

    abstract::Recent advances in electrode design have helped to rekindle clinical interests in noninvasive electrocochleography--to enhance auditory brain stem response (ABR) recordings (namely, wave I) and to screen Meniere's disease. The salient feature of the response in suspected cases of endolymphatic hydrops is an unusually ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199104000-00011

    authors: Durrant JD,Ferraro JA

    更新日期:1991-04-01 00:00:00

  • Prevalence of Hearing Loss Among a Representative Sample of Canadian Children and Adolescents, 3 to 19 Years of Age.

    abstract:OBJECTIVES:There are no nationally representative hearing loss (HL) prevalence data available for Canadian youth using direct measurements. The present study objectives were to estimate national prevalence of HL using audiometric pure-tone thresholds (0.5 to 8 kHz) and or distortion product otoacoustic emissions (DPOAE...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000345

    authors: Feder KP,Michaud D,McNamee J,Fitzpatrick E,Ramage-Morin P,Beauregard Y

    更新日期:2017-01-01 00:00:00

  • Auditory perception changes after reimplantation in a child cochlear implant user.

    abstract::The ability to remove cochlear implants from children and subsequently reimplant a more complex device in the same ear was the concern of this single case study. A postlinguistically deafened child, J.L., received a single-channel cochlear implant 1 yr after contracting meningitis and suffering a profound bilateral se...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199206000-00009

    authors: Chute PM,Hellman SA,Parisier SC,Tartter VC,Economou A

    更新日期:1992-06-01 00:00:00