The statistical basis for serial monitoring in audiology.

Abstract:

OBJECTIVES:Audiologists regularly use serial monitoring to evaluate changes in a patient's auditory function over time. Observed changes are compared with reference standards to determine whether further clinical action is necessary. Reference standards are established in a control sample of otherwise healthy subjects to identify the range of auditory shifts that one might reasonably expect to occur in the absence of any pathological insult. Statistical approaches to this seemingly mundane problem typically invoke 1 of 3 approaches: percentiles of the cumulative distribution, the variance of observed shifts, and the "standard error of measurement." In this article, the authors describe the statistical foundation for these approaches, along with a mixed model-based alternative, and identify several necessary, although typically unacknowledged assumptions. Regression to the mean, the phenomenon of an unusual measurement typically followed by a more common one, can seriously bias observed changes in auditory function and clinical expectations. An approach that adjusts for this important effect is also described. DESIGN:Distortion product otoacoustic emissions (DPOAEs) elicited at a single primary frequency, f2 of 3175 Hz, were collected from 32 healthy subjects at baseline and 19 to 29 days later. Ninety percent test-retest reference limits were computed from these data using each statistical approach. DPOAE shifts were also collected from a sample of 18 cisplatin patients tested after 120 to 200 mg of cisplatin. Reference limits established according to each of the statistical approaches in the healthy sample were used to identify clinically alarming DPOAE shifts in the cisplatin patient sample. RESULTS:Reference limits established with any of the parametric methods were similar. The percentile-based approach gave the widest and least precisely estimated intervals. The highest sensitivity for detecting clinically alarming DPOAE shifts was based on a mixed model approach that adjusts for regression to the mean. CONCLUSIONS:Parametric methods give similar serial monitoring criteria as long as certain critical assumptions are met by the data. The most flexible method for estimating test-retest limits is based on the linear mixed model. Clinical sensitivity may be further enhanced by adjusting for regression to the mean.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

McMillan GP,Reavis KM,Konrad-Martin D,Dille MF

doi

10.1097/AUD.0b013e31828a21b3

subject

Has Abstract

pub_date

2013-09-01 00:00:00

pages

610-8

issue

5

eissn

0196-0202

issn

1538-4667

journal_volume

34

pub_type

临床试验,杂志文章
  • Late-onset auditory deprivation: a review of past research and an assessment of future research needs.

    abstract::This paper includes an overview of the research on late-onset auditory deprivation, an evaluation of the evidence from retrospective and prospective studies, recommendations for future research, and a consideration of the theoretical and clinical implications of the research. The studies reviewed offer convincing evid...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199617031-00002

    authors: Neuman AC

    更新日期:1996-06-01 00:00:00

  • Longitudinal study of pure-tone thresholds in older persons.

    abstract:OBJECTIVE:Pure-tone thresholds for conventional and extended high frequencies were analyzed for 188 older adult human subjects (91 females, 97 males). The objectives were to study longitudinal changes in thresholds as well as the effects of initial threshold levels, age, gender, and noise history on these longitudinal ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200502000-00001

    authors: Lee FS,Matthews LJ,Dubno JR,Mills JH

    更新日期:2005-02-01 00:00:00

  • Human auditory evoked potentials to frequency-modulated tones.

    abstract::Three experiments evaluated steady state and transient auditory evoked potentials (EPs) to tones that were sinusoidally modulated in frequency and to tones that alternated between two frequencies with a linear ramp. The steady state responses to sinusoidal FM were small and difficult to record at both the first and se...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198906000-00003

    authors: Maiste A,Picton T

    更新日期:1989-06-01 00:00:00

  • Effects of stimulus level on the speech perception abilities of children using cochlear implants or digital hearing aids.

    abstract:OBJECTIVE:The present investigation was designed to provide information to facilitate the decision of whether a child should continue using digital signal processing (DSP) hearing aids with wide dynamic range compression (WDRC) or be recommended for a cochlear implant, based on the unaided pure-tone average (PTA at 500...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000234635.48564.ce

    authors: Davidson LS

    更新日期:2006-10-01 00:00:00

  • Effects of a Nucleus multichannel cochlear implant upon speech production in children.

    abstract::The purpose of this report is to describe the speech production of children participating in the Food and Drug Administration's approved clinical trials for the Nucleus multichannel cochlear implant. A significant increase in the ability to imitate nonsegmental aspects of speech was noted after using the implant; howe...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/00003446-199108001-00007

    authors: Tobey EA,Hasenstab S

    更新日期:1991-08-01 00:00:00

  • Auditory Distraction and Acclimatization to Hearing Aids.

    abstract:OBJECTIVE:It is widely recognized by hearing aid users and audiologists that a period of auditory acclimatization and adjustment is needed for new users to become accustomed to their devices. The aim of the present study was to test the idea that auditory acclimatization and adjustment to hearing aids involves a proces...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000366

    authors: Dawes P,Munro KJ

    更新日期:2017-03-01 00:00:00

  • Auditory N1 component to gaps in continuous narrowband noises.

    abstract:OBJECTIVES:To determine whether (1) the auditory N1 component can be elicited to gaps in continuous narrowband noises, (2) psychophysical and electrophysiological gap thresholds (PGTs and EGTs) are similar to one another, and (3) EGTs are the same for all narrowband noise center frequencies. DESIGN:PGTs and EGTs were ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181b1354f

    authors: Atcherson SR,Gould HJ,Mendel MI,Ethington CA

    更新日期:2009-12-01 00:00:00

  • Effects of presentation level on phoneme and sentence recognition in quiet by cochlear implant listeners.

    abstract:OBJECTIVE:The objectives of this study were to characterize the effects of presentation level on speech recognition in quiet by cochlear implant users with the Nucleus 22 SPEAK and Clarion v1.2 CIS speech-processing strategies, and to relate speech recognition at low presentation levels to stimulus audibility as measur...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000090340.09847.39

    authors: Donaldson GS,Allen SL

    更新日期:2003-10-01 00:00:00

  • The effect of differential listening experience on the development of expressive and receptive language in children with bilateral cochlear implants.

    abstract:OBJECTIVES:Growing evidence suggests that children who are deaf and use cochlear implants (CIs) can communicate effectively using spoken language. Research has reported that age of implantation and length of experience with the CI play an important role in a predicting a child's linguistic development. In recent years,...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000023

    authors: Hess C,Zettler-Greeley C,Godar SP,Ellis-Weismer S,Litovsky RY

    更新日期:2014-07-01 00:00:00

  • Transcutaneous vagus nerve stimulation modulates tinnitus-related beta- and gamma-band activity.

    abstract:OBJECTIVES:The ability of a treatment method to interfere with tinnitus-related neural activity patterns, such as cortical gamma rhythms, has been suggested to indicate its potential in relieving tinnitus. Therapeutic modulation of gamma-band oscillations with vagus nerve stimulation has been recently reported in epile...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0000000000000123

    authors: Hyvärinen P,Yrttiaho S,Lehtimäki J,Ilmoniemi RJ,Mäkitie A,Ylikoski J,Mäkelä JP,Aarnisalo AA

    更新日期:2015-05-01 00:00:00

  • Strategies for infant auditory brain stem response assessment.

    abstract::The use of auditory brain stem response (ABR) represents a new dimension in auditory and neurological pediatric assessment. Because the ABR may be altered by stimulus and procedural variables, the lack of an established standard has reduced its clinical efficiency. This paper describes a suggested ABR protocol for inf...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198209000-00006

    authors: Jacobson JT,Morehouse CR,Johnson MJ

    更新日期:1982-09-01 00:00:00

  • Effects of Hearing Impairment and Hearing Aid Amplification on Listening Effort: A Systematic Review.

    abstract:OBJECTIVES:To undertake a systematic review of available evidence on the effect of hearing impairment and hearing aid amplification on listening effort. Two research questions were addressed: Q1) does hearing impairment affect listening effort? and Q2) can hearing aid amplification affect listening effort during speech...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0000000000000396

    authors: Ohlenforst B,Zekveld AA,Jansma EP,Wang Y,Naylor G,Lorens A,Lunner T,Kramer SE

    更新日期:2017-05-01 00:00:00

  • Systemic Aminoglycosides-Induced Vestibulotoxicity in Humans.

    abstract:OBJECTIVES:This systematic review aimed to investigate the prevalence and characteristics of vestibular adverse effects of aminoglycoside (AG) therapy in humans and to analyze objective vestibular tests for the detection of AG-induced vestibulotoxicity. DESIGN:PubMed, Cochrane Database, Web of Science, and reference l...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0000000000000458

    authors: Van Hecke R,Van Rompaey V,Wuyts FL,Leyssens L,Maes L

    更新日期:2017-11-01 00:00:00

  • Impact of Lexical Parameters and Audibility on the Recognition of the Freiburg Monosyllabic Speech Test.

    abstract:OBJECTIVE:Correct word recognition is generally determined by audibility, but lexical parameters also play a role. The focus of this study was to examine both the impact of audibility and lexical parameters on speech recognition of test words of the clinical German Freiburg monosyllabic speech test, and subsequently on...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000737

    authors: Winkler A,Carroll R,Holube I

    更新日期:2020-01-01 00:00:00

  • Factors affecting sensitivity of distortion-product otoacoustic emissions to ototoxic hearing loss.

    abstract:OBJECTIVES:(1) To determine the ototoxicity detection rate (sensitivity) for distortion-product otoacoustic emissions (DPOAEs) testing in adults who received ototoxic medications and experienced pure-tone threshold changes during the course of treatment; (2) to determine the extent to which DPOAE sensitivity to ototoxi...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e318181ad99

    authors: Reavis KM,Phillips DS,Fausti SA,Gordon JS,Helt WJ,Wilmington D,Bratt GW,Konrad-Martin D

    更新日期:2008-12-01 00:00:00

  • Jervell and Lange-Nielsen syndrome in Norwegian children: aspects around cochlear implantation, hearing, and balance.

    abstract:OBJECTIVES:Jervell and Lange-Nielsen syndrome (JLNS) is a rare cause of autosomal recessive inherited deafness. JLNS patients are candidates for cochlear implantation, and represent a group that needs special attention and precautions. The aim of this article is to draw some guidelines for dealing with these patients, ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/aud.0b013e3181645393

    authors: Siem G,Früh A,Leren TP,Heimdal K,Teig E,Harris S

    更新日期:2008-04-01 00:00:00

  • A screening procedure for modified simplex in frequency-gain response selection.

    abstract::The preference for hearing aid frequency-gain responses selected using the modified simplex procedure over that prescribed by NAL-R is not universal. A screening protocol used before individualized fitting may help streamline its use and ensure effective use of clinical time. In this protocol, listeners compare the pr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199402000-00007

    authors: Kuk FK

    更新日期:1994-02-01 00:00:00

  • Behavioral Pure-Tone Threshold Shifts Caused by Tympanic Membrane Electrodes.

    abstract:OBJECTIVE:To determine whether tympanic membrane (TM) electrodes induce behavioral pure-tone threshold shifts. DESIGN:Pure-tone thresholds (250 to 8000 Hz) were measured twice in test (n = 18) and control (n = 10) groups. TM electrodes were placed between first and second threshold measurements in the test group, wher...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000275

    authors: Smith SB,Lichtenhan J,Cone B

    更新日期:2016-07-01 00:00:00

  • Event-related potentials in pediatric cochlear implant patients.

    abstract:OBJECTIVE:The main objective of this study was to assess the correlation of auditory event related potential (ERP) measures with behavioral assessment data to identify if ERPs including mismatch negativity (MMN) can be used to categorize cochlear implant patients into good and poor performers. DESIGN:We investigated a...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200412000-00008

    authors: Singh S,Liasis A,Rajput K,Towell A,Luxon L

    更新日期:2004-12-01 00:00:00

  • Psychophysiological therapy for tinnitus.

    abstract::Twenty-two patients with complaints of severe tinnitus received psychophysiological therapy. Biofeedback sessions were supplemented with body relaxation techniques through the use of audio cassette tapes. The experimental group was matched to a control group according to age and sex. The individuals' names in the cont...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198612000-00009

    authors: White TP,Hoffman SR,Gale EN

    更新日期:1986-12-01 00:00:00

  • Audiologic findings in botulism poisoning.

    abstract::Botulism poisoning results in a presynaptic failure of neuromuscular transmission, and may be expected to impair Eustachian tube and stapedius reflex function. The audiologic findings in five normal-hearing patients with type A botulism poisoning are presented. Results were varied. Two patients demonstrated type B or ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199108000-00007

    authors: Pijl S

    更新日期:1991-08-01 00:00:00

  • Human auditory steady state potentials.

    abstract::The auditory steady state potentials may be an important technique in objective audiometry. The effects of stimulus rate, intensity, and tonal frequency on these potentials were investigated using both signal averaging and on-line Fourier analysis. Stimulus presentation rates of 40 to 45/sec result in a 40 Hz sinusoid...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198403000-00009

    authors: Stapells DR,Linden D,Suffield JB,Hamel G,Picton TW

    更新日期:1984-03-01 00:00:00

  • Speech Recognition and Parent Ratings From Auditory Development Questionnaires in Children Who Are Hard of Hearing.

    abstract:OBJECTIVES:Progress has been made in recent years in the provision of amplification and early intervention for children who are hard of hearing. However, children who use hearing aids (HAs) may have inconsistent access to their auditory environment due to limitations in speech audibility through their HAs or limited HA...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000213

    authors: McCreery RW,Walker EA,Spratford M,Oleson J,Bentler R,Holte L,Roush P

    更新日期:2015-11-01 00:00:00

  • Effects of formant bandwidth on the identification of synthetic vowels by cochlear implant recipients.

    abstract:OBJECTIVE:The main objective was to investigate whether the broadening and narrowing of formant bandwidths had a significant effect on the identification of vowels often confused by Nucleus cochlear implant recipients using the Spectral Peak (SPEAK) speech coding strategy. Specifically, identification performance for s...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199712000-00006

    authors: Hawks JW,Fourakis MS,Skinner MW,Holden TA,Holden LK

    更新日期:1997-12-01 00:00:00

  • Evaluation of four Spanish word-recognition-ability lists.

    abstract::Tests of word recognition ability (formerly Speech Discrimination) should be suitable for the linguistic background of the person being tested. Few efforts have been made to develop a standardized test in the Spanish language. Current literature reports on six studies that have several drawbacks. The purpose of the pr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198912000-00012

    authors: Weisleder P,Hodgson WR

    更新日期:1989-12-01 00:00:00

  • Catastrophizing and fear of tinnitus predict quality of life in patients with chronic tinnitus.

    abstract:OBJECTIVES:It is well established that catastrophic misinterpretations and fear are involved in the suffering and disability of patients with chronic pain. This study investigated whether similar processes explain suffering and disability in patients with chronic tinnitus. We hypothesized that patients who catastrophic...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31821106dd

    authors: Cima RF,Crombez G,Vlaeyen JW

    更新日期:2011-09-01 00:00:00

  • The effects of amplitude normalization and EMG targets on cVEMP interaural amplitude asymmetry.

    abstract:OBJECTIVES:The purpose of this investigation was to determine whether the use of visual feedback of tonic electromyographic (EMG) activity, or the use of amplitude normalization techniques would reduce significantly the variability in cervical vestibular evoked myogenic potential (cVEMP) P13-N23 interaural amplitude as...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31827ad792

    authors: McCaslin DL,Jacobson GP,Hatton K,Fowler AP,DeLong AP

    更新日期:2013-07-01 00:00:00

  • Does the 40-Hz auditory steady-state response show the binaural masking level difference?

    abstract::In contrast to the transient (N1-P2) and steady-state (<20 Hz) cortical responses, neither the transient (auditory brain stem response) nor the steady-state (80 Hz) brain stem responses show the binaural masking level difference (BMLD). This study determined behavioral and 40-Hz auditory steady-state response (ASSR) B...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181b61cc8

    authors: Ishida IM,Stapells DR

    更新日期:2009-12-01 00:00:00

  • Effects of an adaptive filter hearing aid on speech recognition in noise by hearing-impaired subjects.

    abstract::In a digitally controlled adaptive filter, ongoing detection and spectral analysis of quasi steady state noise are performed, and analog filter parameters are adjusted to provide greatest attenuation in frequency regions where noise energy is greatest. Attenuation introduced by the filter affects both speech and noise...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198802000-00012

    authors: van Tasell DJ,Larsen SY,Fabry DA

    更新日期:1988-02-01 00:00:00

  • Accuracy of cochlear implant recipients on pitch perception, melody recognition, and speech reception in noise.

    abstract:OBJECTIVE:The purposes of this study were to (a) examine the accuracy of cochlear implant recipients who use different types of devices and signal processing strategies on pitch ranking as a function of size of interval and frequency range and (b) to examine the relations between this pitch perception measure and demog...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3180479318

    authors: Gfeller K,Turner C,Oleson J,Zhang X,Gantz B,Froman R,Olszewski C

    更新日期:2007-06-01 00:00:00