Effects of Head Movements on Sound-Source Localization in Single-Sided Deaf Patients With Their Cochlear Implant On Versus Off.

Abstract:

OBJECTIVES:We investigated the ability of single-sided deaf listeners implanted with a cochlear implant (SSD-CI) to (1) determine the front-back and left-right location of sound sources presented from loudspeakers surrounding the listener and (2) use small head rotations to further improve their localization performance. The resulting behavioral data were used for further analyses investigating the value of so-called "monaural" spectral shape cues for front-back sound source localization. DESIGN:Eight SSD-CI patients were tested with their cochlear implant (CI) on and off. Eight normal-hearing (NH) listeners, with one ear plugged during the experiment, and another group of eight NH listeners, with neither ear plugged, were also tested. Gaussian noises of 3-sec duration were band-pass filtered to 2-8 kHz and presented from 1 of 6 loudspeakers surrounding the listener, spaced 60° apart. Perceived sound source localization was tested under conditions where the patients faced forward with the head stationary, and under conditions where they rotated their heads between (Equation is included in full-text article.). RESULTS:(1) Under stationary listener conditions, unilaterally-plugged NH listeners and SSD-CI listeners (with their CIs both on and off) were nearly at chance in determining the front-back location of high-frequency sound sources. (2) Allowing rotational head movements improved performance in both the front-back and left-right dimensions for all listeners. (3) For SSD-CI patients with their CI turned off, head rotations substantially reduced front-back reversals, and the combination of turning on the CI with head rotations led to near-perfect resolution of front-back sound source location. (4) Turning on the CI also improved left-right localization performance. (5) As expected, NH listeners with both ears unplugged localized to the correct front-back and left-right hemifields both with and without head movements. CONCLUSIONS:Although SSD-CI listeners demonstrate a relatively poor ability to distinguish the front-back location of sound sources when their head is stationary, their performance is substantially improved with head movements. Most of this improvement occurs when the CI is off, suggesting that the NH ear does most of the "work" in this regard, though some additional gain is introduced with turning the CI on. During head turns, these listeners appear to primarily rely on comparing changes in head position to changes in monaural level cues produced by the direction-dependent attenuation of high-frequency sounds that result from acoustic head shadowing. In this way, SSD-CI listeners overcome limitations to the reliability of monaural spectral and level cues under stationary conditions. SSD-CI listeners may have learned, through chronic monaural experience before CI implantation, or with the relatively impoverished spatial cues provided by their CI-implanted ear, to exploit the monaural level cue. Unilaterally-plugged NH listeners were also able to use this cue during the experiment to realize approximately the same magnitude of benefit from head turns just minutes after plugging, though their performance was less accurate than that of the SSD-CI listeners, both with and without their CI turned on.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Pastore MT,Natale SJ,Clayton C,Dorman MF,Yost WA,Zhou Y

doi

10.1097/AUD.0000000000000882

subject

Has Abstract

pub_date

2020-11-01 00:00:00

pages

1660-1674

issue

6

eissn

0196-0202

issn

1538-4667

pii

00003446-202011000-00022

journal_volume

41

pub_type

杂志文章
  • A Cross-Language Comparison of Sentence Recognition Using American English and Mandarin Chinese HINT and AzBio Sentences.

    abstract:OBJECTIVES:The aim of this study was to perform a cross-language comparison of two commonly used sentence-recognition materials (i.e., Hearing in Noise Test [HINT] and AzBio) in American English (AE) and Mandarin Chinese (MC). DESIGNS:Sixty normal-hearing, native English-speaking and 60 normal-hearing, native Chinese-...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000938

    authors: Xu L,Xi X,Patton A,Wang X,Qi B,Johnson L

    更新日期:2020-08-19 00:00:00

  • Listening effort and perceived clarity for normal-hearing children with the use of digital noise reduction.

    abstract:OBJECTIVES:The goal of this study was to evaluate how digital noise reduction (DNR) impacts listening effort and judgment of sound clarity in children with normal hearing. It was hypothesized that when two DNR algorithms differing in signal-to-noise ratio (SNR) output are compared, the algorithm that provides the great...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000440715.85844.b8

    authors: Gustafson S,McCreery R,Hoover B,Kopun JG,Stelmachowicz P

    更新日期:2014-03-01 00:00:00

  • Phase stability of auditory steady state responses in newborn infants.

    abstract:OBJECTIVES:This study examined the phases of auditory steady state responses (ASSRs) evoked by exponentially amplitude-modulated (AM) tones in 44 newborn infants (within 3 days of birth) and in 15 older infants (within 3 to 15 wks of birth). Our hypothesis was that the phases of the ASSRs would show orderly changes wit...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e318212085e

    authors: Choi JM,Purcell DW,John MS

    更新日期:2011-09-01 00:00:00

  • Discriminating and responsiveness abilities of two hearing handicap scales.

    abstract::Several scales exist for screening handicap and assessing rehabilitation in elderly individuals with hearing loss. There are few comparative studies, however, to suggest which scales perform best. Using receiver-operating curves and responsiveness indices, we examined the relative discriminating ability and sensitivit...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199006000-00002

    authors: Mulrow CD,Tuley MR,Aguilar C

    更新日期:1990-06-01 00:00:00

  • Use of probe tube microphone measurements in hearing aid selection for children: some initial clinical experiences.

    abstract::Some initial experiences are described in which ear canal probe tube microphone measurements are used to determine hearing aid settings for children. Decisions are based upon ideas developed by Seewald and Ross (in Amplification for the Hearing Impaired, New York: Grune & Stratton, 1988: 213-267) and Seewald, Ross, an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198910000-00002

    authors: Hawkins DB,Morrison TM,Halligan PL,Cooper WA

    更新日期:1989-10-01 00:00:00

  • Relationship between two dichotic listening tests and the Token test for children.

    abstract::The relationship between two dichotic listening tasks was studied. The two dichotic tests used were the Staggered Spondaic Word (SSW) test and the directed Dichotic Consonant-Vowel (CV) test. These measures were administered to 104 children between the ages of 6.0 and 8.0 yrs. The subjects were divided into two groups...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198311000-00003

    authors: Harris VL,Keith RW,Novak KK

    更新日期:1983-11-01 00:00:00

  • Neurophysiological Differences in Emotional Processing by Cochlear Implant Users, Extending Beyond the Realm of Speech.

    abstract:OBJECTIVE:Cochlear implants (CIs) restore a sense of hearing in deaf individuals. However, they do not transmit the acoustic signal with sufficient fidelity, leading to difficulties in recognizing emotions in voice and in music. The study aimed to explore the neurophysiological bases of these limitations. DESIGN:Twent...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000701

    authors: Deroche MLD,Felezeu M,Paquette S,Zeitouni A,Lehmann A

    更新日期:2019-09-01 00:00:00

  • Speech Detection in Noise for Young Bilaterally Implanted Children: Is There Evidence of Binaural Benefit Over the Shadowed Ear Alone?

    abstract:OBJECTIVES:To measure binaural benefit over the shadowed ear alone for young bilateral cochlear implant (CI) users. It was hypothesized that children who received bilateral CIs at a young age (<4 years), and had significant bilateral experience, would demonstrate lower detection thresholds for speech sounds in backgrou...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000442

    authors: Galvin KL,Dowell RC,van Hoesel RJ,Mok M

    更新日期:2017-11-01 00:00:00

  • The effects of reversing the polarity of frequency-limited single-cycle stimuli on the human auditory brain stem response.

    abstract::This study was conducted to investigate morphologic differences in the ABR as a result of reversing the stimulus polarity of frequency-limited single-cycle stimuli in normal-hearing subjects. The results clearly demonstrate that large latency differences occur between condensation and rarefaction stimuli for low-frequ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199506000-00008

    authors: Orlando MS,Folsom RC

    更新日期:1995-06-01 00:00:00

  • Repeatability of high-frequency bone conduction thresholds.

    abstract::The purpose of this study was to determine the repeatability of high-frequency, bone conduction thresholds and to increase the data base concerning high-frequency, bone conduction threshold levels. Bone conduction thresholds were obtained on 30 subjects having normal, low, and mid frequency (0.25 to 8 kHz) hearing thr...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/00003446-198712000-00010

    authors: Frank T,Ragland AE

    更新日期:1987-12-01 00:00:00

  • Audiologic manifestations of patients with post-treatment Lyme disease syndrome.

    abstract:OBJECTIVE:The purpose of this study was to characterize auditory function in patients diagnosed with post-treatment Lyme disease syndrome (PTLDS). DESIGN:Eighteen patients with PTLDS were evaluated and compared to a normal population. Evaluations consisted of pure tone and speech thresholds, word recognition (WRS), ac...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000100205.25774.5F

    authors: Shotland LI,Mastrioanni MA,Choo DL,Szymko-Bennett YM,Dally LG,Pikus AT,Sledjeski K,Marques A

    更新日期:2003-12-01 00:00:00

  • Relative effects of low-frequency amplification on syllable recognition and speech quality.

    abstract::A moderate-bandwidth master hearing aid was used to study the relationships among low-frequency response, syllable recognition scores, and perceived speech quality. As measured on KEMAR, this hearing aid provided true high-frequency emphasis in all conditions, with three degrees of relative low-frequency de-emphasis. ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198604000-00001

    authors: Punch JL,Beck LB

    更新日期:1986-04-01 00:00:00

  • Use of Direct-Connect for Remote Speech-Perception Testing in Cochlear Implants.

    abstract:OBJECTIVES:Previous research has demonstrated the feasibility of programming cochlear implants (CIs) via telepractice. To effectively use telepractice in a comprehensive manner, all components of a clinical CI visit should be validated using remote technology. Speech-perception testing is important for monitoring outco...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000693

    authors: Sevier JD,Choi S,Hughes ML

    更新日期:2019-09-01 00:00:00

  • Hearing aid patients in private practice and public health (Veterans Affairs) clinics: are they different?

    abstract:OBJECTIVE:In hearing aid research, it is commonplace to combine data across subjects whose hearing aids were provided in different service delivery models. There is reason to question whether these types of patients are always similar enough to justify this practice. To explore this matter, this investigation evaluated...

    journal_title:Ear and hearing

    pub_type: 杂志文章,多中心研究

    doi:10.1097/01.aud.0000188188.01311.0b

    authors: Cox RM,Alexander GC,Gray GA

    更新日期:2005-12-01 00:00:00

  • Perception of rhythmic and sequential pitch patterns by normally hearing adults and adult cochlear implant users.

    abstract:OBJECTIVE:This study compares the musical perception of 17 adult recipients of the Nucleus cochlear implant using two different formant extraction processing strategies (F0F1F2 and MPEAK). DESIGN:Over a 12 mo period, participants were alternately switched between two strategies every 3 mo. Performance was evaluated us...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199706000-00008

    authors: Gfeller K,Woodworth G,Robin DA,Witt S,Knutson JF

    更新日期:1997-06-01 00:00:00

  • A Bayesian perspective on tinnitus pitch matching.

    abstract:OBJECTIVES:New tinnitus therapies are being developed and marketed that target the patient's tinnitus frequency. This frequency is estimated clinically by pitch matching, which has the patient identify the pure tone that is closest to the perceived tinnitus frequency. Though widely used, pitch matching is heavily criti...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000081

    authors: McMillan GP,Thielman EJ,Wypych K,Henry JA

    更新日期:2014-11-01 00:00:00

  • Callsign Acquisition Test (CAT): speech intelligibility in noise.

    abstract:OBJECTIVE:The study was designed to assess the effects of noise on the intelligibility of speech elements used in the Callsign Acquisition Test (CAT), developed by the U.S. Army Research Laboratory. The CAT consists of 126 test items, or callsigns, each of which is made up of a two-syllable word selected from the 18-it...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000202289.32228.f6

    authors: Rao MD,Letowski T

    更新日期:2006-04-01 00:00:00

  • Description and primary results from an audiometric study of male twins.

    abstract:OBJECTIVE:The purpose of this study is to present descriptive results from an audiometric examination of a male twin sample, compare the values with normative databases, and explore whether there are age differences in genetic and environmental contributions to variation in hearing. DESIGN:Audiometric and questionnair...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199704000-00003

    authors: Karlsson KK,Harris JR,Svartengren M

    更新日期:1997-04-01 00:00:00

  • Hearing in time: evoked potential studies of temporal processing.

    abstract::This article reviews the temporal aspects of human hearing as measured using the auditory evoked potentials. Interaural timing cues are essential to the detection and localization of sound sources. The temporal envelope of a sound--how it changes in amplitude over time--is crucially important for speech perception. Ti...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0b013e31827ada02

    authors: Picton T

    更新日期:2013-07-01 00:00:00

  • The risks of amplified music for disc-jockeys working in nightclubs.

    abstract:OBJECTIVES:Here, we evaluate the risks of amplified music for disc-jockeys (DJs) working in nightclubs. DESIGN:Sound level measurements were performed within the DJ mixing booths. A questionnaire was used to obtain exposure to noise and length of time in the profession. Audiograms and tinnitus pitch matching was also ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31819769fc

    authors: Potier M,Hoquet C,Lloyd R,Nicolas-Puel C,Uziel A,Puel JL

    更新日期:2009-04-01 00:00:00

  • Otodental dysplasia: a five year study.

    abstract::Peripheral auditory sensitivity is documented over a 5-year period on 4 cases with otodental dysplasia. Age of onset is noted for the proband and indicates that onset of this progressive hearing loss occurs as early as the first decade. Findings suggest that the hearing loss plateaus by the fourth decade, resulting in...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198103000-00007

    authors: Cook RA,Cox JR,Jorgenson RJ

    更新日期:1981-03-01 00:00:00

  • Hearing handicap ratings among different profiles of adult cochlear implant users.

    abstract:OBJECTIVE:The aim was to compare outcomes in the domain of self-reported hearing handicap across groups of patients fit with one versus two cochlear implants (CI, CI + CI), or with an implant and a hearing aid (HA) in the nonimplanted ear (CI + HA). DESIGN:The design was retrospective, and a preliminary step was to fa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31815d6da8

    authors: Noble W,Tyler R,Dunn C,Bhullar N

    更新日期:2008-01-01 00:00:00

  • Consonant recognition and confusion patterns among elderly hearing-impaired subjects.

    abstract::This study investigated whether unique consonant recognition and confusion patterns are associated with hearing loss among elderly listeners. Subjects were all greater than 65 years, and had normal hearing, or gradually or sharply sloping sensorineural hearing losses. Recognition of 19 consonants, paired with each of ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198710000-00003

    authors: Gordon-Salant S

    更新日期:1987-10-01 00:00:00

  • Does the 40-Hz auditory steady-state response show the binaural masking level difference?

    abstract::In contrast to the transient (N1-P2) and steady-state (<20 Hz) cortical responses, neither the transient (auditory brain stem response) nor the steady-state (80 Hz) brain stem responses show the binaural masking level difference (BMLD). This study determined behavioral and 40-Hz auditory steady-state response (ASSR) B...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181b61cc8

    authors: Ishida IM,Stapells DR

    更新日期:2009-12-01 00:00:00

  • Event-related potentials in pediatric cochlear implant patients.

    abstract:OBJECTIVE:The main objective of this study was to assess the correlation of auditory event related potential (ERP) measures with behavioral assessment data to identify if ERPs including mismatch negativity (MMN) can be used to categorize cochlear implant patients into good and poor performers. DESIGN:We investigated a...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200412000-00008

    authors: Singh S,Liasis A,Rajput K,Towell A,Luxon L

    更新日期:2004-12-01 00:00:00

  • Evaluation of Speed and Accuracy of Next-Generation Auditory Steady State Response and Auditory Brainstem Response Audiometry in Children With Normal Hearing and Hearing Loss.

    abstract:OBJECTIVES:The first objective of this study was to compare the predicted audiometric thresholds obtained by auditory steady state response (ASSR) and auditory brainstem response (ABR) in infants and toddlers when both techniques use optimal stimuli and detection algorithms. This information will aid in determining the...

    journal_title:Ear and hearing

    pub_type: 杂志文章,多中心研究

    doi:10.1097/AUD.0000000000000580

    authors: Sininger YS,Hunter LL,Hayes D,Roush PA,Uhler KM

    更新日期:2018-11-01 00:00:00

  • Reinforced active middle ear implant fixation in incus vibroplasty.

    abstract:OBJECTIVES:The active middle ear implant Vibrant Soundbridge® was originally designed to treat mild-to-severe sensorineural hearing losses. The floating mass transducer (FMT) is crimped onto the long incus process. The procedure is termed incus vibroplasty to distinguish from other attachment sites or stimulus modi for...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000078

    authors: Mlynski R,Dalhoff E,Heyd A,Wildenstein D,Hagen R,Gummer AW,Schraven SP

    更新日期:2015-01-01 00:00:00

  • Initial independent results with the Clarion cochlear implant.

    abstract:OBJECTIVE:This paper reports some preliminary findings from patients, implanted at the University of Iowa, using the Advanced Bionics Clarion cochlear implant (version 1.0). We compared the performance of patients using both simultaneous analog and nonsimultaneous pulsatile processing strategies. The performance of Cla...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199612000-00008

    authors: Tyler RS,Gantz BJ,Woodworth GG,Parkinson AJ,Lowder MW,Schum LK

    更新日期:1996-12-01 00:00:00

  • Americans hear as well or better today compared with 40 years ago: hearing threshold levels in the unscreened adult population of the United States, 1959-1962 and 1999-2004.

    abstract:OBJECTIVES:(1) To present hearing threshold data from a recent nationally representative survey in the United States (National Health and Nutrition Examination Survey, 1999-2004) in a distributional format that might be appropriate to replace Annex B in international (ISO-1999) and national (ANSI S3.44) standards and (...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181e9770e

    authors: Hoffman HJ,Dobie RA,Ko CW,Themann CL,Murphy WJ

    更新日期:2010-12-01 00:00:00

  • Converting insertion gain to and from headphone coupler responses.

    abstract:OBJECTIVE:The paper aims to show how insertion gain responses can be translated into equivalent headphone responses, and vice versa. DESIGN:The relationship between the response types is theoretically derived by allowing for real ear to coupler differences and for real ear unaided responses. RESULTS:The necessary cor...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199708000-00009

    authors: Dillon H

    更新日期:1997-08-01 00:00:00