Monothermal Caloric Screening to Improve Healthcare Value.

Abstract:

OBJECTIVES:To evaluate whether monothermal caloric screening can reduce the number of caloric irrigations required in the vestibular testing battery while maintaining diagnostic accuracy. DESIGN:Prospective controlled cohort study. Three hundred and ninety patients referred for vestibular testing at this tertiary referral health system over a 1-year period were evaluated; 24 patients met exclusion or failure criteria and 366 patients were included in the study. Population was 35.6% male; average age was 50.4 years old. Each patient underwent caloric testing using either warm or cool water irrigation initially and this data was used for monothermal screening data. All patients then completed bithermal binaural caloric testing to obtain the "gold standard" bithermal data for comparison. The sensitivity and specificity of monothermal cool or monothermal warm caloric tests were calculated using a receiver operating characteristic curve analysis. RESULTS:Using a monothermal interear difference threshold of 25%, warm monothermal screening had sensitivity of 98.0%, specificity of 91.3%, false negative rate of 2%, and false positive rate of 8.7%. Cool monothermal screening also had excellent sensitivity (92.3%) and specificity (95.3)%, with a false negative rate of 7.7%, and a false positive rate of 4.7%. The diagnosis associated with the single false negative warm monothermal caloric test was compensated vestibular paresis. In the study population, 71.9% had a negative monothermal screen; if the monothermal data were accepted, 2 fewer irrigations would have been performed resulting in an average saving of $264 (typical Medicare reimbursement for 2 irrigations) billed per patient screened as well as shortening the average testing battery by about 15 min. CONCLUSIONS:Warm monothermal caloric screening can reduce time and cost of vestibular testing while nearly matching the diagnostic accuracy of bithermal testing.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Thatcher AL,Beckerman ML,Telian SA,King WM

doi

10.1097/AUD.0000000000000262

subject

Has Abstract

pub_date

2016-05-01 00:00:00

pages

e188-93

issue

3

eissn

0196-0202

issn

1538-4667

journal_volume

37

pub_type

杂志文章
  • Qualities of Single Electrode Stimulation as a Function of Rate and Place of Stimulation with a Cochlear Implant.

    abstract:OBJECTIVES:Although it has been shown previously that changes in temporal coding produce changes in pitch in all cochlear regions, research has suggested that temporal coding might be best encoded in relatively apical locations. The authors hypothesized that although temporal coding may provide useable information at a...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000250

    authors: Landsberger DM,Vermeire K,Claes A,Van Rompaey V,Van de Heyning P

    更新日期:2016-05-01 00:00:00

  • Melodic contour identification by cochlear implant listeners.

    abstract:OBJECTIVE:While the cochlear implant provides many deaf patients with good speech understanding in quiet, music perception and appreciation with the cochlear implant remains a major challenge for most cochlear implant users. The present study investigated whether a closed-set melodic contour identification (MCI) task c...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000261689.35445.20

    authors: Galvin JJ 3rd,Fu QJ,Nogaki G

    更新日期:2007-06-01 00:00:00

  • Highly variable population-based prevalence rates of unilateral hearing loss after the application of common case definitions.

    abstract:OBJECTIVES:This study shows how population-based estimates of the prevalence of unilateral hearing loss (UHL) in children aged 6 to 19 yrs can differ considerably with various applications of commonly accepted case definitions. It also examines demographic variables and risk factors related to UHL. DESIGN:The Third Na...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181bb69db

    authors: Ross DS,Visser SN,Holstrum WJ,Qin T,Kenneson A

    更新日期:2010-02-01 00:00:00

  • The effect of differential listening experience on the development of expressive and receptive language in children with bilateral cochlear implants.

    abstract:OBJECTIVES:Growing evidence suggests that children who are deaf and use cochlear implants (CIs) can communicate effectively using spoken language. Research has reported that age of implantation and length of experience with the CI play an important role in a predicting a child's linguistic development. In recent years,...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000023

    authors: Hess C,Zettler-Greeley C,Godar SP,Ellis-Weismer S,Litovsky RY

    更新日期:2014-07-01 00:00:00

  • The mismatch negativity: a powerful tool for cognitive neuroscience.

    abstract::This article reviews research on the relatively recently discovered event-related potential component, the mismatch negativity (MMN), which is of great potential interest for understanding central auditory function and various forms of its pathology. This change-specific response can serve as an accurate objective mea...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:

    authors: Näätänen R

    更新日期:1995-02-01 00:00:00

  • Comparison of the Motor Performance and Vestibular Function in Infants with a Congenital Cytomegalovirus Infection or a Connexin 26 Mutation: A Preliminary Study.

    abstract:OBJECTIVES:Hearing-impaired children are at risk for vestibular damage and delayed motor development. Two major causes of congenital hearing loss are cytomegalovirus (CMV) infection and connexin (Cx) 26 mutations. Comparison of the motor performance and vestibular function between these specific groups is still underex...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000364

    authors: Maes L,De Kegel A,Van Waelvelde H,De Leenheer E,Van Hoecke H,Goderis J,Dhooge I

    更新日期:2017-01-01 00:00:00

  • Initial independent results with the Clarion cochlear implant.

    abstract:OBJECTIVE:This paper reports some preliminary findings from patients, implanted at the University of Iowa, using the Advanced Bionics Clarion cochlear implant (version 1.0). We compared the performance of patients using both simultaneous analog and nonsimultaneous pulsatile processing strategies. The performance of Cla...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199612000-00008

    authors: Tyler RS,Gantz BJ,Woodworth GG,Parkinson AJ,Lowder MW,Schum LK

    更新日期:1996-12-01 00:00:00

  • Degradation of labial information modifies audiovisual speech perception in cochlear-implanted children.

    abstract:OBJECTIVE:The aim of the present study was to examine audiovisual speech integration in cochlear-implanted children and in normally hearing children exposed to degraded auditory stimuli. Previous studies have shown that speech perception in cochlear-implanted users is biased toward the visual modality when audition and...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3182670993

    authors: Huyse A,Berthommier F,Leybaert J

    更新日期:2013-01-01 00:00:00

  • SSW test performance-intensity functions for hearing-impaired adults.

    abstract::The present study investigated the effects of intensity on hearing-impaired adults' performance on the Staggered Spondaic Word (SSW) test. Fifteen adults having mild-to-moderate cochlear hearing losses were administered the 40-item SSW test which was subdivided into four groups of ten items each, and presented at diff...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198411000-00004

    authors: Flynn PA,Danhauer JL,Gerber SE,Goller MC,Arnst DJ

    更新日期:1984-11-01 00:00:00

  • Speech recognition ability of children with unilateral sensorineural hearing loss as a function of amplification, speech stimuli and listening condition.

    abstract::The purpose of this investigation was to examine three types of audiological recommendations [unaided, CROS (contralateral routing of signals) and personal FM system] and their impact upon speech recognition ability of children with unilateral sensorineural hearing loss. Each of these recommendations was tested under ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199008000-00003

    authors: Kenworthy OT,Klee T,Tharpe AM

    更新日期:1990-08-01 00:00:00

  • The effect of voice cuing on releasing speech from informational masking disappears in older adults.

    abstract:OBJECTIVE:To investigate whether older adults can use voice information to unmask speech. DESIGN:Under a voice-priming condition, before a target-speech sentence was presented with a noise or speech masker, one or two voice-priming sentences were recited with the same voice reciting the target sentence. Eighteen young...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181db6dc2

    authors: Huang Y,Xu L,Wu X,Li L

    更新日期:2010-08-01 00:00:00

  • Evaluation of four Spanish word-recognition-ability lists.

    abstract::Tests of word recognition ability (formerly Speech Discrimination) should be suitable for the linguistic background of the person being tested. Few efforts have been made to develop a standardized test in the Spanish language. Current literature reports on six studies that have several drawbacks. The purpose of the pr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198912000-00012

    authors: Weisleder P,Hodgson WR

    更新日期:1989-12-01 00:00:00

  • Design and function: a physical and electrical description of the 3M House cochlear implant system.

    abstract::A patient-wearable, single-electrode cochlear implant was first used by a patient in 1972 at the House Ear Institute. Since early 1982, a redesigned version of this system has been in clinical use. This new system, called the 3M House cochlear implant system, consists of an implanted receiver and a patient-worn signal...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:

    authors: Fretz RJ,Fravel RP

    更新日期:1985-05-01 00:00:00

  • Predictive properties of the video head impulse test: measures of caloric symmetry and self-report dizziness handicap.

    abstract:OBJECTIVES:The purpose of this investigation was to determine whether a predictable relationship existed between self-reported dizziness handicap and video Head Impulse Test (vHIT) results in a large sample of patients reporting to a dizziness clinic. Secondary objectives included describing the characteristics of the ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000047

    authors: McCaslin DL,Jacobson GP,Bennett ML,Gruenwald JM,Green AP

    更新日期:2014-09-01 00:00:00

  • Evoked potentials: computer-automated threshold-tracking procedure using an objective detection criterion.

    abstract::A computer-automated, threshold-tracking procedure was developed for measuring evoked response thresholds on-line. The procedure utilizes an objective detection criterion (correlation) to evaluate whether a response is absent or present. Sound intensity is adjusted according to a modified PEST (parameter estimation by...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:

    authors: Salvi RJ,Ahroon W,Saunders SS,Arnold SA

    更新日期:1987-06-01 00:00:00

  • Head Movements Allow Listeners Bilaterally Implanted With Cochlear Implants to Resolve Front-Back Confusions.

    abstract:OBJECTIVES:We report on the ability of patients fit with bilateral cochlear implants (CIs) to distinguish the front-back location of sound sources both with and without head movements. At issue was (i) whether CI patients are more prone to front-back confusions than normal hearing listeners for wideband, high-frequency...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000581

    authors: Pastore MT,Natale SJ,Yost WA,Dorman MF

    更新日期:2018-11-01 00:00:00

  • Effect of electrode impedance on spread of excitation and pitch perception using electrically coupled "dual-electrode" stimulation.

    abstract:OBJECTIVES:In newer-generation Cochlear Ltd. cochlear implants, two adjacent electrodes can be electrically coupled to produce a single contact or "dual electrode" (DE). The goal of the present study was to evaluate whether relatively large impedance differences (>3.0 kOhms) between coupled electrodes affect the excita...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000098

    authors: Hughes ML,Baudhuin JL,Goehring JL

    更新日期:2015-03-01 00:00:00

  • Strategies for infant auditory brain stem response assessment.

    abstract::The use of auditory brain stem response (ABR) represents a new dimension in auditory and neurological pediatric assessment. Because the ABR may be altered by stimulus and procedural variables, the lack of an established standard has reduced its clinical efficiency. This paper describes a suggested ABR protocol for inf...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198209000-00006

    authors: Jacobson JT,Morehouse CR,Johnson MJ

    更新日期:1982-09-01 00:00:00

  • Visual Acuity and Cognition in Older Adults With and Without Hearing Loss: Evidence For Late-Life Sensory Compensation?

    abstract:OBJECTIVES:Relationships between cognitive and sensory functioning become stronger with advancing age, and the debate on underlying mechanisms continues. Interestingly, the potential mechanism of compensation by the unaffected sensory modality has so far been investigated in younger age groups with congenital sensory i...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000531

    authors: Wettstein M,Wahl HW,Heyl V

    更新日期:2018-07-01 00:00:00

  • Identifying dead regions in the cochlea: psychophysical tuning curves and tone detection in threshold-equalizing noise.

    abstract:OBJECTIVE:Recent studies indicate that high-frequency amplification may provide little benefit for listeners with moderate-to-severe high-frequency hearing loss, and may even reduce speech recognition. Moore and colleagues have proposed a direct link between this lack of benefit and the presence of regions of nonfuncti...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000058148.27540.D9

    authors: Summers V,Molis MR,Müsch H,Walden BE,Surr RK,Cord MT

    更新日期:2003-04-01 00:00:00

  • List equivalency of the CID everyday sentences (Harris revision) under three signal-to-noise ratios.

    abstract::The primary purpose of this study was to determine list equivalency of Harris' revision of the CID Everyday Sentence Lists under three signal-to-noise ratios: O dB, --3 dB, and --6 dB. On the basis of list means, nonsignificant groupings of lists were found at each noise level; however, lists were not equivalent at an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198309000-00006

    authors: Rippy JV,Dancer JE,Pittenger JB

    更新日期:1983-09-01 00:00:00

  • Signal to noise constraints on maximum length sequence auditory brain stem responses.

    abstract::In conventional auditory brain stem response (ABR) testing, the stimulus rate must be low enough that the responses do not overlap. By using stimulus patterns derived from the pseudorandom binary series known as maximum length sequences (MLSs), it is possible to stimulate at mean rates of hundreds of clicks per second...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199212000-00004

    authors: Marsh RR

    更新日期:1992-12-01 00:00:00

  • Converting insertion gain to and from headphone coupler responses.

    abstract:OBJECTIVE:The paper aims to show how insertion gain responses can be translated into equivalent headphone responses, and vice versa. DESIGN:The relationship between the response types is theoretically derived by allowing for real ear to coupler differences and for real ear unaided responses. RESULTS:The necessary cor...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199708000-00009

    authors: Dillon H

    更新日期:1997-08-01 00:00:00

  • Mechanisms of Localization and Speech Perception with Colocated and Spatially Separated Noise and Speech Maskers Under Single-Sided Deafness with a Cochlear Implant.

    abstract:OBJECTIVES:This study tested listeners with a cochlear implant (CI) in one ear and acoustic hearing in the other ear, to assess their ability to localize sound and to understand speech in collocated or spatially separated noise or speech maskers. DESIGN:Eight CI listeners with contralateral acoustic hearing ranging fr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000708

    authors: Dirks C,Nelson PB,Sladen DP,Oxenham AJ

    更新日期:2019-11-01 00:00:00

  • Preimplant measures of preverbal communicative behavior as predictors of cochlear implant outcomes in children.

    abstract:OBJECTIVE:Comparison of preverbal communication behavior in young children before receiving cochlear implants with outcomes 3 yr after implantation on speech identification and speech production tasks, to assess whether outcomes can be predicted from characteristics inherent to the child before implantation. DESIGN:Vi...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200002000-00005

    authors: Tait M,Lutman ME,Robinson K

    更新日期:2000-02-01 00:00:00

  • Music perception of cochlear implant users compared with that of hearing aid users.

    abstract:OBJECTIVES:To investigate the music perception skills of adult cochlear implant (CI) users in comparison with hearing aid (HA) users who have similar levels of hearing impairment. It was hypothesized that the HA users would perform better than the CI recipients on tests involving pitch, instrument, and melody perceptio...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31816a0d0b

    authors: Looi V,McDermott H,McKay C,Hickson L

    更新日期:2008-06-01 00:00:00

  • Temporal Fine Structure Processing, Pitch, and Speech Perception in Adult Cochlear Implant Recipients.

    abstract:OBJECTIVES:The aim of the study was to investigate the link between temporal fine structure (TFS) processing, pitch, and speech perception performance in adult cochlear implant (CI) recipients, including bimodal listeners who may benefit better low-frequency (LF) temporal coding in the contralateral ear. DESIGN:The st...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000525

    authors: Dincer D'Alessandro H,Ballantyne D,Boyle PJ,De Seta E,DeVincentiis M,Mancini P

    更新日期:2018-07-01 00:00:00

  • Effects of stimulus level on the speech perception abilities of children using cochlear implants or digital hearing aids.

    abstract:OBJECTIVE:The present investigation was designed to provide information to facilitate the decision of whether a child should continue using digital signal processing (DSP) hearing aids with wide dynamic range compression (WDRC) or be recommended for a cochlear implant, based on the unaided pure-tone average (PTA at 500...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000234635.48564.ce

    authors: Davidson LS

    更新日期:2006-10-01 00:00:00

  • Factors affecting sensitivity of distortion-product otoacoustic emissions to ototoxic hearing loss.

    abstract:OBJECTIVES:(1) To determine the ototoxicity detection rate (sensitivity) for distortion-product otoacoustic emissions (DPOAEs) testing in adults who received ototoxic medications and experienced pure-tone threshold changes during the course of treatment; (2) to determine the extent to which DPOAE sensitivity to ototoxi...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e318181ad99

    authors: Reavis KM,Phillips DS,Fausti SA,Gordon JS,Helt WJ,Wilmington D,Bratt GW,Konrad-Martin D

    更新日期:2008-12-01 00:00:00

  • Use of test-retest measures to evaluate performance stability in adults with cochlear implants.

    abstract:OBJECTIVE:This study was designed to evaluate performance stability with test-retest measures of electrical thresholds, electrical maximum acceptable loudness levels, sound-field thresholds, and audition-only speech tests. The hypothesis was that the standard error of measurement differs from one individual to another ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199504000-00006

    authors: Skinner MW,Holden LK,Demorest ME,Holden TA

    更新日期:1995-04-01 00:00:00