Pitfalls in neurotologic diagnosis.

Abstract:

:Several cases illustrating potential pitfalls in neurotologic diagnosis from the viewpoint of the otologist are presented. The role of auditory brain stem response testing is specifically emphasized in cases with discordant audiologic and radiographic findings. Included are one case of a "false negative" ABR in a patient with an intracanalicular acoustic neuroma, a case of a "false positive" CT scan in a patient with Meniere's disease, and a case of a patient with normal hearing in whom an acoustic neuroma was discovered serendipitously.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Telian SA,Kileny PR

doi

10.1097/00003446-198804000-00007

subject

Has Abstract

pub_date

1988-04-01 00:00:00

pages

86-91

issue

2

eissn

0196-0202

issn

1538-4667

journal_volume

9

pub_type

杂志文章
  • Multisite Randomized Controlled Trial to Compare Two Methods of Tinnitus Intervention to Two Control Conditions.

    abstract:OBJECTIVES:In this four-site clinical trial, we evaluated whether tinnitus masking (TM) and tinnitus retraining therapy (TRT) decreased tinnitus severity more than the two control groups: an attention-control group that received tinnitus educational counseling (and hearing aids if needed; TED), and a 6-month-wait-list ...

    journal_title:Ear and hearing

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1097/AUD.0000000000000330

    authors: Henry JA,Stewart BJ,Griest S,Kaelin C,Zaugg TL,Carlson K

    更新日期:2016-11-01 00:00:00

  • Head Movements Allow Listeners Bilaterally Implanted With Cochlear Implants to Resolve Front-Back Confusions.

    abstract:OBJECTIVES:We report on the ability of patients fit with bilateral cochlear implants (CIs) to distinguish the front-back location of sound sources both with and without head movements. At issue was (i) whether CI patients are more prone to front-back confusions than normal hearing listeners for wideband, high-frequency...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000581

    authors: Pastore MT,Natale SJ,Yost WA,Dorman MF

    更新日期:2018-11-01 00:00:00

  • Speech-in-speech listening on the LiSN-S test by older adults with good audiograms depends on cognition and hearing acuity at high frequencies.

    abstract:OBJECTIVES:The main objective was to investigate age-related differences on the listening in spatialized noise-sentences (LiSN-S) test in adults with normal audiometric thresholds in most of the speech range. A second objective was to examine the contributions of auditory, cognitive, and linguistic abilities to LiSN-S ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000096

    authors: Besser J,Festen JM,Goverts ST,Kramer SE,Pichora-Fuller MK

    更新日期:2015-01-01 00:00:00

  • Speech Detection in Noise for Young Bilaterally Implanted Children: Is There Evidence of Binaural Benefit Over the Shadowed Ear Alone?

    abstract:OBJECTIVES:To measure binaural benefit over the shadowed ear alone for young bilateral cochlear implant (CI) users. It was hypothesized that children who received bilateral CIs at a young age (<4 years), and had significant bilateral experience, would demonstrate lower detection thresholds for speech sounds in backgrou...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000442

    authors: Galvin KL,Dowell RC,van Hoesel RJ,Mok M

    更新日期:2017-11-01 00:00:00

  • Effects of the number of channels and speech-to-noise ratio on rate of connected discourse tracking through a simulated cochlear implant speech processor.

    abstract:OBJECTIVE:To investigate the effects of number of channels and speech-to-noise ratio on connected discourse tracking (CDT) through simulations of cochlear implant speech processing. Previous studies have used citation-form vowel and consonant materials or simple sentences. CDT rates were expected to be less likely to b...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200110000-00007

    authors: Faulkner A,Rosen S,Wilkinson L

    更新日期:2001-10-01 00:00:00

  • Real ear attenuation at threshold for three audiometric headphone devices: implications for maximum permissible ambient noise level standards.

    abstract::Attenuation measurements were made using the ANSI S12.6-1984 protocol on a standard Telephonics headset with TDH-50P earphones and Model 51 cushions, Amplivox Audiocups headphone enclosures, and Peltor AudioMate headphone enclosures. Each of the enclosures housed Telephonics TDH-50P earphones with Model 51 cushions. T...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199202000-00004

    authors: Franks JR,Engel DP 3rd,Themann CL

    更新日期:1992-02-01 00:00:00

  • Use of test-retest measures to evaluate performance stability in adults with cochlear implants.

    abstract:OBJECTIVE:This study was designed to evaluate performance stability with test-retest measures of electrical thresholds, electrical maximum acceptable loudness levels, sound-field thresholds, and audition-only speech tests. The hypothesis was that the standard error of measurement differs from one individual to another ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199504000-00006

    authors: Skinner MW,Holden LK,Demorest ME,Holden TA

    更新日期:1995-04-01 00:00:00

  • Hearing impairment and health-related quality of life: the Blue Mountains Hearing Study.

    abstract:OBJECTIVES:To assess the association between hearing impairment and health-related quality of life (HRQOL) in an older population, using the self-administered 36-item Short-Form Health Survey (SF-36). DESIGN:Participants of the Blue Mountains Hearing Study (BMHS, N = 2956) attended a comprehensive interview and hearin...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31803126b6

    authors: Chia EM,Wang JJ,Rochtchina E,Cumming RR,Newall P,Mitchell P

    更新日期:2007-04-01 00:00:00

  • Melodic contour identification by cochlear implant listeners.

    abstract:OBJECTIVE:While the cochlear implant provides many deaf patients with good speech understanding in quiet, music perception and appreciation with the cochlear implant remains a major challenge for most cochlear implant users. The present study investigated whether a closed-set melodic contour identification (MCI) task c...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000261689.35445.20

    authors: Galvin JJ 3rd,Fu QJ,Nogaki G

    更新日期:2007-06-01 00:00:00

  • Auditory N1 component to gaps in continuous narrowband noises.

    abstract:OBJECTIVES:To determine whether (1) the auditory N1 component can be elicited to gaps in continuous narrowband noises, (2) psychophysical and electrophysiological gap thresholds (PGTs and EGTs) are similar to one another, and (3) EGTs are the same for all narrowband noise center frequencies. DESIGN:PGTs and EGTs were ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181b1354f

    authors: Atcherson SR,Gould HJ,Mendel MI,Ethington CA

    更新日期:2009-12-01 00:00:00

  • Hearing in time: evoked potential studies of temporal processing.

    abstract::This article reviews the temporal aspects of human hearing as measured using the auditory evoked potentials. Interaural timing cues are essential to the detection and localization of sound sources. The temporal envelope of a sound--how it changes in amplitude over time--is crucially important for speech perception. Ti...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0b013e31827ada02

    authors: Picton T

    更新日期:2013-07-01 00:00:00

  • Effects of presentation level on phoneme and sentence recognition in quiet by cochlear implant listeners.

    abstract:OBJECTIVE:The objectives of this study were to characterize the effects of presentation level on speech recognition in quiet by cochlear implant users with the Nucleus 22 SPEAK and Clarion v1.2 CIS speech-processing strategies, and to relate speech recognition at low presentation levels to stimulus audibility as measur...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000090340.09847.39

    authors: Donaldson GS,Allen SL

    更新日期:2003-10-01 00:00:00

  • Air-Conducted Vestibular Evoked Myogenic Potential Testing in Children, Adolescents, and Young Adults: Thresholds, Frequency Tuning, and Effects of Sound Exposure.

    abstract:OBJECTIVES:Pediatric vestibular evaluations incorporate cervical and ocular vestibular evoked myogenic potential (c- and oVEMP, respectively) testing; however, in children, c- and oVEMP thresholds have been minimally investigated and frequency tuning is unknown. Children are also at risk for unsafe sound exposure secon...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000607

    authors: Rodriguez AI,Thomas MLA,Janky KL

    更新日期:2019-01-01 00:00:00

  • Transfer functions and correction factors used in hearing aid evaluation and research.

    abstract::In hearing aid research and application it is often necessary to transform the sound pressure level or acoustic gain measured at one physical point (e.g., 2 cc coupler) to an equivalent value at another physical point (e.g., tympanic membrane). Results of currently available studies on various transformations are summ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198902000-00010

    authors: Bentler RA,Pavlovic CV

    更新日期:1989-02-01 00:00:00

  • The effects of reversing the polarity of frequency-limited single-cycle stimuli on the human auditory brain stem response.

    abstract::This study was conducted to investigate morphologic differences in the ABR as a result of reversing the stimulus polarity of frequency-limited single-cycle stimuli in normal-hearing subjects. The results clearly demonstrate that large latency differences occur between condensation and rarefaction stimuli for low-frequ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199506000-00008

    authors: Orlando MS,Folsom RC

    更新日期:1995-06-01 00:00:00

  • Status of school children's hearing aids relative to monitoring practices.

    abstract::Data concerning hearing aid monitoring practices and hearing aid malfunction were collected for three groups of mainstreamed hearing-impaired children: 248 children receiving services from itinerant teachers of the hearing impaired, 43 who participated in a study involving extensive psychoeducational evaluation, and 1...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/00003446-198808000-00007

    authors: Elfenbein JL,Bentler RA,Davis JM,Niebuhr DP

    更新日期:1988-08-01 00:00:00

  • Isolating informational masking in both pure and complex tone sequences.

    abstract:OBJECTIVES:Interference between a target and simultaneous maskers occurs both at the cochlear level through energetic masking and more centrally through informational masking (IM). Hence, quantifying the amount of IM requires a strict control of the energetic component. Presenting target and maskers on different sides ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000116

    authors: Calcus A,Agus T,Kolinsky R,Colin C,Deltenre P

    更新日期:2015-05-01 00:00:00

  • Speech perception using maps based on neural response telemetry measures.

    abstract:OBJECTIVE:To determine how speech perception is affected for Nucleus cochlear implant users when their speech processor is programmed using neural response telemetry (NRT) measures rather than traditional behavioral estimates of threshold and maximum comfort level. DESIGN:Electrically evoked compound action potential ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200202001-00009

    authors: Seyle K,Brown CJ

    更新日期:2002-02-01 00:00:00

  • Results from a European clinical investigation of the Nucleus multichannel auditory brainstem implant.

    abstract:OBJECTIVE:This study was designed to investigate the perceptual benefits and potential risks of implanting the Nucleus(R) multichannel auditory brainstem implant. DESIGN:Between September 1992 and October 1997 a total of 27 subjects received a Nucleus 20- or 21-channel Auditory Brainstem Implant (ABI). All subjects in...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/00003446-200206000-00002

    authors: Nevison B,Laszig R,Sollmann WP,Lenarz T,Sterkers O,Ramsden R,Fraysse B,Manrique M,Rask-Andersen H,Garcia-Ibanez E,Colletti V,von Wallenberg E

    更新日期:2002-06-01 00:00:00

  • Frequency-specific temporal envelope and periodicity components for lexical tone identification in Cantonese.

    abstract:OBJECTIVES:Temporal envelope and periodicity components (TEPC) in the speech signal have potentials to offer important cues for speech recognition especially in tonal languages. The aims of this study are: (i) to investigate the degree of contributions of TEPC to lexical tone identification in Cantonese; and (ii) to in...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31803153ac

    authors: Yuen KC,Yuan M,Lee T,Soli S,Tong MC,van Hasselt CA

    更新日期:2007-04-01 00:00:00

  • Does the 40-Hz auditory steady-state response show the binaural masking level difference?

    abstract::In contrast to the transient (N1-P2) and steady-state (<20 Hz) cortical responses, neither the transient (auditory brain stem response) nor the steady-state (80 Hz) brain stem responses show the binaural masking level difference (BMLD). This study determined behavioral and 40-Hz auditory steady-state response (ASSR) B...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181b61cc8

    authors: Ishida IM,Stapells DR

    更新日期:2009-12-01 00:00:00

  • Measurement of individual loudness functions by trisection of loudness ranges.

    abstract:OBJECTIVES:Loudness-balance measurements with monaurally impaired subjects have shown that the shape of the loudness versus sound-pressure curve among hearing-impaired persons varies significantly. But the effectiveness of adjusting the compression characteristics of wide-dynamic-range compression hearing aids-the comp...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e318177d9c6

    authors: Villchur E,Killion MC

    更新日期:2008-10-01 00:00:00

  • Repeatability of high-frequency bone conduction thresholds.

    abstract::The purpose of this study was to determine the repeatability of high-frequency, bone conduction thresholds and to increase the data base concerning high-frequency, bone conduction threshold levels. Bone conduction thresholds were obtained on 30 subjects having normal, low, and mid frequency (0.25 to 8 kHz) hearing thr...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/00003446-198712000-00010

    authors: Frank T,Ragland AE

    更新日期:1987-12-01 00:00:00

  • Children's recognition of spectrally degraded cartoon voices.

    abstract:OBJECTIVES:Although the spectrally degraded input provided by cochlear implants (CIs) is sufficient for speech perception in quiet, it poses problems for talker identification. The present study examined the ability of normally hearing (NH) children and child CI users to recognize cartoon voices while listening to spec...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3182a468d0

    authors: van Heugten M,Volkova A,Trehub SE,Schellenberg EG

    更新日期:2014-01-01 00:00:00

  • List equivalency of the CID everyday sentences (Harris revision) under three signal-to-noise ratios.

    abstract::The primary purpose of this study was to determine list equivalency of Harris' revision of the CID Everyday Sentence Lists under three signal-to-noise ratios: O dB, --3 dB, and --6 dB. On the basis of list means, nonsignificant groupings of lists were found at each noise level; however, lists were not equivalent at an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198309000-00006

    authors: Rippy JV,Dancer JE,Pittenger JB

    更新日期:1983-09-01 00:00:00

  • Converting insertion gain to and from headphone coupler responses.

    abstract:OBJECTIVE:The paper aims to show how insertion gain responses can be translated into equivalent headphone responses, and vice versa. DESIGN:The relationship between the response types is theoretically derived by allowing for real ear to coupler differences and for real ear unaided responses. RESULTS:The necessary cor...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199708000-00009

    authors: Dillon H

    更新日期:1997-08-01 00:00:00

  • Identification, assessment, and management of children with unilateral sensorineural hearing loss.

    abstract::Because some unilaterally hearing-impaired children appear to experience difficulty in communication and educational progress, it seems only appropriate to reassess the identification and management strategies that are used with these children. Accordingly, this paper presents some general information on identificatio...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198602000-00008

    authors: Bess FH,Klee T,Culbertson JL

    更新日期:1986-02-01 00:00:00

  • The influence of clicks versus short tone bursts on the vestibular evoked myogenic potentials.

    abstract:OBJECTIVE:Vestibular evoked myogenic potential (VEMP) has become a diagnostic tool to evaluate the integrity of sacculo-collic reflex. To obtain a more consistent VEMP response in normal-hearing subjects, we examine whether clicks or short tone bursts are more effective in eliciting VEMP responses. DESIGN:Prospective ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000069225.80220.CB

    authors: Cheng PW,Huang TW,Young YH

    更新日期:2003-06-01 00:00:00

  • The effect of hearing aid microphone mode on performance in an auditory orienting task.

    abstract:OBJECTIVES:Although directional microphones on a hearing aid provide a signal-to-noise ratio benefit in a noisy background, the amount of benefit is dependent on how close the signal of interest is to the front of the user. It is assumed that when the signal of interest is off-axis, users can reorient themselves to the...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000053

    authors: Brimijoin WO,Whitmer WM,McShefferty D,Akeroyd MA

    更新日期:2014-09-01 00:00:00

  • Exchange rates for intermittent and fluctuating occupational noise: a systematic review of studies of human permanent threshold shift.

    abstract:OBJECTIVE:The aim of this study was to review the literature regarding human noise-induced permanent threshold shift and to determine whether the observed data agreed with the predictions of two different exchange rates (ERs). DESIGN:An initial list of possibly relevant studies included those cited by authors who endo...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0b013e3182a143ec

    authors: Dobie RA,Clark WW

    更新日期:2014-01-01 00:00:00