Abstract:
OBJECTIVE:This study compares the musical perception of 17 adult recipients of the Nucleus cochlear implant using two different formant extraction processing strategies (F0F1F2 and MPEAK). DESIGN:Over a 12 mo period, participants were alternately switched between two strategies every 3 mo. Performance was evaluated using three measures of rhythmic and sequential pitch perception. RESULTS:Three individuals performed significantly better with the MPEAK strategy on one particular rhythm task, 11 participants performed better with the MPEAK strategy on another rhythm task, and no significant differences were found between the two strategies on a sequential pitch pattern task. CONCLUSIONS:Neither strategy seems clearly superior for perception of either sequential pitch or rhythmic patterns.
journal_name
Ear Hearjournal_title
Ear and hearingauthors
Gfeller K,Woodworth G,Robin DA,Witt S,Knutson JFdoi
10.1097/00003446-199706000-00008subject
Has Abstractpub_date
1997-06-01 00:00:00pages
252-60issue
3eissn
0196-0202issn
1538-4667journal_volume
18pub_type
杂志文章相关文献
EAR AND HEARING文献大全abstract:OBJECTIVES:Previous studies have documented the benefits of bimodal hearing as compared with a cochlear implant alone, but most have focused on the importance of bottom-up, low-frequency cues. The purpose of the present study was to evaluate the role of top-down processing in bimodal hearing by measuring the effect of ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000298
更新日期:2016-09-01 00:00:00
abstract:OBJECTIVES:To compare the sound-source localization, discrimination, and tracking performance of bilateral cochlear implant users with omnidirectional (OMNI) and pinna-imitating (PI) microphone directionality modes. DESIGN:Twelve experienced bilateral cochlear implant users participated in the study. Their audio proce...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000912
更新日期:2020-07-16 00:00:00
abstract:OBJECTIVE:Despite the many studies on the associated risk of cardiovascular and cerebrovascular events in patients with hypercholesterolemia (HCh), an association between HCh and the development of idiopathic sudden sensorineural hearing loss (ISSNHL) has been examined in only a few case-control studies. We tested the ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e3182a76637
更新日期:2014-03-01 00:00:00
abstract::Full-term and preterm infants were evaluated with click-evoked and distortion-product otoacoustic emissions (CEOEs and DPOEs). The CEOEs and DPOEs recorded from each individual ear were analyzed by calculating the root-mean-square levels within half-octave bands. The fail criterion of the OE tests was that the half-oc...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199308000-00005
更新日期:1993-08-01 00:00:00
abstract::Paired comparison perception and preference judgments of hearing aid processed music were examined under conditions of extended and reduced high and low-frequency ranges. The performance of 20 subjects with mild to moderate hearing impairment was compared with an equal number of normal hearing controls. Subjects with ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198201000-00004
更新日期:1982-01-01 00:00:00
abstract::Speech recognition thresholds (SRTs) were measured for a closed set of spondees that had been processed by peak clipping and compression. Both hearing-impaired and normal-hearing subject groups showed progressively higher SRTs with increasing levels of peak clipping, with significant threshold shifts occurring for cli...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199412000-00005
更新日期:1994-12-01 00:00:00
abstract::This study reviews audiologic findings on cases of hearing-impaired elderly adults who were matched on the basis of peripheral hearing loss and who were divided into cochlear and retrocochlear groups on the basis of auditory brain stem response (ABR) test results. ABR test results were compared to other audiologic tes...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199102000-00008
更新日期:1991-02-01 00:00:00
abstract::No outcome measure has universal validity and applicability. When designing, promulgating or selecting a particular instrument, audiologists should take care to consider and specify the detailed purposes to which the measure will be directed, and the particular populations to which it will be applied. Scales that have...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200008001-00013
更新日期:2000-08-01 00:00:00
abstract:OBJECTIVES:Habituation to tinnitus cannot occur with total masking, an argument made by proponents of "tinnitus retraining therapy." We also compared the effectiveness of retraining therapy with mixing-point masking, total masking, and with counseling alone. DESIGN:Forty-eight tinnitus patients were randomly assigned ...
journal_title:Ear and hearing
pub_type: 杂志文章,随机对照试验
doi:10.1097/AUD.0b013e31824f2a6e
更新日期:2012-09-01 00:00:00
abstract:OBJECTIVES:This systematic review aimed to investigate the prevalence and characteristics of vestibular adverse effects of aminoglycoside (AG) therapy in humans and to analyze objective vestibular tests for the detection of AG-induced vestibulotoxicity. DESIGN:PubMed, Cochrane Database, Web of Science, and reference l...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/AUD.0000000000000458
更新日期:2017-11-01 00:00:00
abstract:OBJECTIVES:In a cross-sectional study of human immunodeficiency virus (HIV)-infected adults, the authors showed lower distortion product otoacoustic emissions (DPOAEs) in HIV+ individuals compared with controls as well as findings consistent with a central auditory processing deficit in HIV+ adults on antiretroviral th...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000276
更新日期:2016-07-01 00:00:00
abstract:OBJECTIVE:Establishing methods for topical administration of drugs to the inner ear have great clinical relevance and potential even in a relatively short perspective. To evaluate the efficacy of sodium hyaluronate (HYA) as a vehicle for drugs that could be used for treatment of inner ear disorders. METHODS:The cochle...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31818ff98e
更新日期:2009-02-01 00:00:00
abstract:OBJECTIVE:This study completed an evidence-based practice systematic review of the nonacoustic benefits for adult patients receiving bone-anchored hearing aid(s) (BAHAs) relative to other forms of amplification (i.e., none, bone-conduction hearing aids [BCHAs], or air-conduction hearing aids [ACHAs]). DESIGN:Systemati...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/01.aud.0000240635.70277.3f
更新日期:2006-12-01 00:00:00
abstract:OBJECTIVES:In this four-site clinical trial, we evaluated whether tinnitus masking (TM) and tinnitus retraining therapy (TRT) decreased tinnitus severity more than the two control groups: an attention-control group that received tinnitus educational counseling (and hearing aids if needed; TED), and a 6-month-wait-list ...
journal_title:Ear and hearing
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1097/AUD.0000000000000330
更新日期:2016-11-01 00:00:00
abstract::This article reviews the temporal aspects of human hearing as measured using the auditory evoked potentials. Interaural timing cues are essential to the detection and localization of sound sources. The temporal envelope of a sound--how it changes in amplitude over time--is crucially important for speech perception. Ti...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/AUD.0b013e31827ada02
更新日期:2013-07-01 00:00:00
abstract:OBJECTIVES:Recent animal studies suggest that noise-induced synaptopathy may underlie a phenomenon that has been labeled hidden hearing loss (HHL). Noise exposure preferentially damages low spontaneous-rate auditory nerve fibers, which are involved in the processing of moderate- to high-level sounds and are more resist...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000543
更新日期:2018-09-01 00:00:00
abstract::A computer-automated, threshold-tracking procedure was developed for measuring evoked response thresholds on-line. The procedure utilizes an objective detection criterion (correlation) to evaluate whether a response is absent or present. Sound intensity is adjusted according to a modified PEST (parameter estimation by...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:
更新日期:1987-06-01 00:00:00
abstract::Three experiments evaluated steady state and transient auditory evoked potentials (EPs) to tones that were sinusoidally modulated in frequency and to tones that alternated between two frequencies with a linear ramp. The steady state responses to sinusoidal FM were small and difficult to record at both the first and se...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198906000-00003
更新日期:1989-06-01 00:00:00
abstract:OBJECTIVE:Current Joint Committee on Infant Hearing guidelines recommend the use of transient-evoked otoacoustic emissions (TEOAEs) as a screening tool to identify hearing loss for newborns cared for in the well-baby nursery. Newborns who do not pass the TEOAE screen before leaving the hospital are typically rescreened...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31819c4000
更新日期:2009-06-01 00:00:00
abstract::The purpose of this report is to describe the speech production of children participating in the Food and Drug Administration's approved clinical trials for the Nucleus multichannel cochlear implant. A significant increase in the ability to imitate nonsegmental aspects of speech was noted after using the implant; howe...
journal_title:Ear and hearing
pub_type: 临床试验,杂志文章
doi:10.1097/00003446-199108001-00007
更新日期:1991-08-01 00:00:00
abstract::A patient-wearable, single-electrode cochlear implant was first used by a patient in 1972 at the House Ear Institute. Since early 1982, a redesigned version of this system has been in clinical use. This new system, called the 3M House cochlear implant system, consists of an implanted receiver and a patient-worn signal...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:
更新日期:1985-05-01 00:00:00
abstract:OBJECTIVES:The impact of social distancing on communication and psychosocial variables among individuals with hearing impairment during COVID-19 pandemic. It was our concern that patients who already found themselves socially isolated (Wie et al. 2010) as a result of their hearing loss would be perhaps more susceptible...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000991
更新日期:2020-12-22 00:00:00
abstract:OBJECTIVES:Interference between a target and simultaneous maskers occurs both at the cochlear level through energetic masking and more centrally through informational masking (IM). Hence, quantifying the amount of IM requires a strict control of the energetic component. Presenting target and maskers on different sides ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000116
更新日期:2015-05-01 00:00:00
abstract:OBJECTIVES:To assess discrimination of lexical stress pattern in infants with cochlear implant (CI) compared with infants with normal hearing (NH). While criteria for cochlear implantation have expanded to infants as young as 6 months, little is known regarding infants' processing of suprasegmental-prosodic cues which ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000243
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVE:Comparison of preverbal communication behavior in young children before receiving cochlear implants with outcomes 3 yr after implantation on speech identification and speech production tasks, to assess whether outcomes can be predicted from characteristics inherent to the child before implantation. DESIGN:Vi...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200002000-00005
更新日期:2000-02-01 00:00:00
abstract:OBJECTIVES:The objectives of this study were to examine the quantity of adult words, adult-child conversational turns, and electronic media in the auditory environments of toddlers who are hard of hearing (HH) and to examine whether these factors contributed to variability in children's communication outcomes. DESIGN:...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e3182a76768
更新日期:2014-03-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to evaluate streamlined programming procedures for the Nucleus cochlear implant system with the Contour electrode array. DESIGN:Phase 1 involved an examination of the clinical MAPs for the first 103 recipients implanted with the Contour electrode array in the Melbourne Cochlea...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.aud.0000188201.86799.01
更新日期:2005-12-01 00:00:00
abstract::In recent years there has been an increased acceptance of the cochlear implant as an appropriate sensory aid for selected hearing-impaired individuals with profound losses. With the Food and Drug Administration's release of the 3M/House single channel cochlear implant on November 29, 1984 and the Nucleus 22-channel co...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198604000-00003
更新日期:1986-04-01 00:00:00
abstract:OBJECTIVE:Research was conducted to assess multichannel saliency with the Ineraid cochlear prosthesis. The goal was to determine whether tonotopically ordered stimulation benefits speech reception. DESIGN:In a single high-performing subject, changes in speech reception were studied during two dramatic alterations to t...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199510000-00002
更新日期:1995-10-01 00:00:00
abstract:OBJECTIVES:Temporal envelope and periodicity components (TEPC) in the speech signal have potentials to offer important cues for speech recognition especially in tonal languages. The aims of this study are: (i) to investigate the degree of contributions of TEPC to lexical tone identification in Cantonese; and (ii) to in...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31803153ac
更新日期:2007-04-01 00:00:00