Changes in the Compressive Nonlinearity of the Cochlea During Early Aging: Estimates From Distortion OAE Input/Output Functions.

Abstract:

OBJECTIVES:The level-dependent growth of distortion product otoacoustic emissions (DPOAEs) provides an indirect metric of cochlear compressive nonlinearity. Recent evidence suggests that aging reduces nonlinear distortion emissions more than those associated with linear reflection. Therefore, in this study, we generate input/output (I/O) functions from the isolated distortion component of the DPOAE to probe the effects of early aging on the compressive nonlinearity of the cochlea. DESIGN:Thirty adults whose ages ranged from 18 to 64 years participated in this study, forming a continuum of young to middle-age subjects. When necessary for analyses, subjects were divided into a young-adult group with a mean age of 21 years, and a middle-aged group with a mean age of 52 years. All young-adult subjects and 11 of the middle-aged subjects had normal hearing; 4 middle-aged ears had slight audiometric threshold elevation at mid-to-high frequencies. DPOAEs (2f1 - f2) were recorded using primary tones swept upward in frequency from 0.5 to 8 kHz, and varied from 25 to 80 dB sound pressure level. The nonlinear distortion component of the total DPOAE was separated and used to create I/O functions at one-half octave intervals from 1.3 to 7.4 kHz. Four features of OAE compression were extracted from a fit to these functions: compression threshold, range of compression, compression slope, and low-level growth. These values were compared between age groups and correlational analyses were conducted between OAE compression threshold and age with audiometric threshold controlled. RESULTS:Older ears had reduced DPOAE amplitude compared with young-adult ears. The OAE compression threshold was elevated at test frequencies above 2 kHz in the middle-aged subjects by 19 dB (35 versus 54 dB SPL), thereby reducing the compression range. In addition, middle-aged ears showed steeper amplitude growth beyond the compression threshold. Audiometric threshold was initially found to be a confound in establishing the relationship between compression and age; however, statistical analyses allowed us to control its variance. Correlations performed while controlling for age differences in high-frequency audiometric thresholds showed significant relationships between the DPOAE I/O compression threshold and age: Older subjects tended to have elevated compression thresholds compared with younger subjects and an extended range of monotonic growth. CONCLUSIONS:Cochlear manifestations of nonlinearity, such as the DPOAE, weaken during early aging, and DPOAE I/O functions become linearized. Commensurate changes in high-frequency audiometric thresholds are not sufficient to fully explain these changes. The results suggest that age-related changes in compressive nonlinearity could produce a reduced dynamic range of hearing, and contribute to perceptual difficulties in older listeners.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Ortmann AJ,Abdala C

doi

10.1097/AUD.0000000000000319

subject

Has Abstract

pub_date

2016-09-01 00:00:00

pages

603-14

issue

5

eissn

0196-0202

issn

1538-4667

journal_volume

37

pub_type

杂志文章
  • Search for Electrophysiological Indices of Hidden Hearing Loss in Humans: Click Auditory Brainstem Response Across Sound Levels and in Background Noise.

    abstract:OBJECTIVES:Recent studies in animals indicate that even moderate levels of exposure to noise can damage synaptic ribbons between the inner hair cells and auditory nerve fibers without affecting audiometric thresholds, giving rise to the use of the term "hidden hearing loss" (HHL). Despite evidence across several animal...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000905

    authors: Suresh CH,Krishnan A

    更新日期:2020-07-13 00:00:00

  • The influence of RECD transducer when deriving real-ear sound pressure level.

    abstract:OBJECTIVE:The main aim of the present study was to compare the derived and directly measured real-ear hearing instrument performance for a range of commonly used hearing instruments. A secondary aim was to compare the real-ear to coupler difference (RECD) measured using the ER-3A insert earphone and a selection of hear...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000224123.22568.82

    authors: Munro KJ,Millward KE

    更新日期:2006-08-01 00:00:00

  • Mechanisms of Localization and Speech Perception with Colocated and Spatially Separated Noise and Speech Maskers Under Single-Sided Deafness with a Cochlear Implant.

    abstract:OBJECTIVES:This study tested listeners with a cochlear implant (CI) in one ear and acoustic hearing in the other ear, to assess their ability to localize sound and to understand speech in collocated or spatially separated noise or speech maskers. DESIGN:Eight CI listeners with contralateral acoustic hearing ranging fr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000708

    authors: Dirks C,Nelson PB,Sladen DP,Oxenham AJ

    更新日期:2019-11-01 00:00:00

  • Objective calibration of bone conductors using otoacoustic emissions.

    abstract:OBJECTIVE:To demonstrate a technique for objectively calibrating bone conductors on an individual basis using distortion product otoacoustic emissions (DPOAEs). DESIGN:Individual calibrations were obtained using DPOAEs recorded from a single ear of 21 normally hearing adults. Validity and robustness of the technique w...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199910000-00001

    authors: Purcell D,Kunov H,Cleghorn W

    更新日期:1999-10-01 00:00:00

  • Identification, assessment, and management of children with unilateral sensorineural hearing loss.

    abstract::Because some unilaterally hearing-impaired children appear to experience difficulty in communication and educational progress, it seems only appropriate to reassess the identification and management strategies that are used with these children. Accordingly, this paper presents some general information on identificatio...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198602000-00008

    authors: Bess FH,Klee T,Culbertson JL

    更新日期:1986-02-01 00:00:00

  • Audiologic findings in Pierre Robin sequence.

    abstract::The hearing status of 20 individuals with Pierre Robin Sequence (micrognathia, cleft palate, and glossoptosis leading to respiratory distress and feeding difficulty) was examined and compared to a sample exhibiting only isolated cleft palate. The results indicate that there is no difference in the prevalence or degree...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198906000-00013

    authors: Gould HJ

    更新日期:1989-06-01 00:00:00

  • Americans hear as well or better today compared with 40 years ago: hearing threshold levels in the unscreened adult population of the United States, 1959-1962 and 1999-2004.

    abstract:OBJECTIVES:(1) To present hearing threshold data from a recent nationally representative survey in the United States (National Health and Nutrition Examination Survey, 1999-2004) in a distributional format that might be appropriate to replace Annex B in international (ISO-1999) and national (ANSI S3.44) standards and (...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181e9770e

    authors: Hoffman HJ,Dobie RA,Ko CW,Themann CL,Murphy WJ

    更新日期:2010-12-01 00:00:00

  • Wideband reflectance measures of the ipsilateral acoustic stapedius reflex threshold.

    abstract:OBJECTIVE:The purpose of this study was to develop a method for acoustically measuring the ipsilateral acoustic stapedius reflex threshold by using wideband shifts in energy reflectance and admittance. DESIGN:A group of 27 young adult subjects with normal hearing participated in the study. Contralateral reflex thresho...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000145110.60657.73

    authors: Feeney MP,Keefe DH,Sanford CA

    更新日期:2004-10-01 00:00:00

  • Maturation of Mechanical Impedance of the Skin-Covered Skull: Implications for Soft Band Bone-Anchored Hearing Systems Fitted in Infants and Young Children.

    abstract:OBJECTIVES:Little is known about the maturational changes in the mechanical properties of the skull and how they might contribute to infant-adult differences in bone conduction hearing sensitivity. The objective of this study was to investigate the mechanical impedance of the skin-covered skull for different skull posi...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000272

    authors: Mackey AR,Hodgetts WE,Scott D,Small SA

    更新日期:2016-07-01 00:00:00

  • Pre- and Postoperative Binaural Unmasking for Bimodal Cochlear Implant Listeners.

    abstract:OBJECTIVES:Cochlear implants (CIs) are increasingly recommended to individuals with residual bilateral acoustic hearing. Although new hearing-preserving electrode designs and surgical approaches show great promise, CI recipients are still at risk to lose acoustic hearing in the implanted ear, which could prevent the ab...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000420

    authors: Sheffield BM,Schuchman G,Bernstein JGW

    更新日期:2017-09-01 00:00:00

  • Different Associations between Auditory Function and Cognition Depending on Type of Auditory Function and Type of Cognition.

    abstract:OBJECTIVES:Previous studies strongly suggest that declines in auditory threshold can lead to impaired cognition. The aim of this study was to expand that picture by investigating how the relationships between age, auditory function, and cognitive function vary with the types of auditory and cognitive function considere...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000700

    authors: Danielsson H,Humes LE,Rönnberg J

    更新日期:2019-09-01 00:00:00

  • The mismatch negativity: a powerful tool for cognitive neuroscience.

    abstract::This article reviews research on the relatively recently discovered event-related potential component, the mismatch negativity (MMN), which is of great potential interest for understanding central auditory function and various forms of its pathology. This change-specific response can serve as an accurate objective mea...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:

    authors: Näätänen R

    更新日期:1995-02-01 00:00:00

  • Coupler output level differences resulting from repeated transducer placement.

    abstract::Coupler output levels were obtained for six repeated placements of a TDH-49 earphone in a P/N 51 cushion on a NBS 9A coupler and a B-71 and B-72 bone vibrator on a mechanical coupler from 250 to 4000 Hz using experienced (N = 9) and untrained subjects (N = 9) who were later trained. The largest minus the smallest coup...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198608000-00009

    authors: Frank T,Chaffinch JO,Svitko CS

    更新日期:1986-08-01 00:00:00

  • Evaluation of a localization training program for hearing impaired listeners.

    abstract:OBJECTIVE:To evaluate the effectiveness of a home-based and a laboratory-based localization training program. DESIGN:This study examined the effectiveness of a localization training program on improving the localization ability of 15 participants with a mild-to-moderately severe hearing loss. These participants had wo...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0000000000000067

    authors: Kuk F,Keenan DM,Lau C,Crose B,Schumacher J

    更新日期:2014-11-01 00:00:00

  • Reliability of Vestibular Perceptual Threshold Testing About the Yaw Axis.

    abstract:OBJECTIVES:Vestibular reflexes have traditionally formed the cornerstone of vestibular evaluation, but perceptual tests have recently gained attention for use in research studies and potential clinical applications. However, the unknown reliability of perceptual thresholds limits their current importance. This is addre...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000859

    authors: Lee TL,Shayman CS,Oh Y,Peterka RJ,Hullar TE

    更新日期:2020-11-01 00:00:00

  • Relevance of Artifact Removal and Number of Stimuli for Video Head Impulse Test Examination.

    abstract:OBJECTIVE:To evaluate the effect of artifacts on the impulse and response recordings with the video head impulse test (VHIT) and determine how many stimuli are necessary for obtaining acceptably efficient measurements. METHODS:One hundred fifty patients were examined using VHIT and their registries searched for artifa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000849

    authors: Trinidad-Ruiz G,Rey-Martinez J,Matiño-Soler E,Batuecas-Caletrio A,Martin-Sanz E,Perez-Fernandez N

    更新日期:2020-09-01 00:00:00

  • The contribution of family history to hearing loss in an older population.

    abstract:OBJECTIVES:Although it has been well established that the prevalence of and severity of hearing loss increase with age, the contribution of familial factors to age-related hearing loss cannot be quantified. This is largely because hearing loss in older people has both genetic and environmental contributions. As environ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31817349d6

    authors: McMahon CM,Kifley A,Rochtchina E,Newall P,Mitchell P

    更新日期:2008-08-01 00:00:00

  • Sound-direction identification with bilateral cochlear implants.

    abstract:OBJECTIVE:The purpose of this study was to compare the accuracy of sound-direction identification in the horizontal plane by bilateral cochlear implant users when localization was measured with pink noise and with speech stimuli. DESIGN:Eight adults who were bilateral users of Nucleus 24 Contour devices participated i...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000249910.80803.b9

    authors: Neuman AC,Haravon A,Sislian N,Waltzman SB

    更新日期:2007-02-01 00:00:00

  • On the Etiology of Listening Difficulties in Noise Despite Clinically Normal Audiograms.

    abstract::Many people with difficulties following conversations in noisy settings have "clinically normal" audiograms, that is, tone thresholds better than 20 dB HL from 0.1 to 8 kHz. This review summarizes the possible causes of such difficulties, and examines established as well as promising new psychoacoustic and electrophys...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0000000000000388

    authors: Pienkowski M

    更新日期:2017-03-01 00:00:00

  • Evaluation of a tinnitus masking program: a follow-up study of 598 patients.

    abstract::A follow-up study of two groups of tinnitus patients was conducted in an attempt to evaluate the tinnitus masking program. Results are discussed separately for a group of patients seen during the first three years of the program (1976 through 1978) and during the last year (1979). These results suggest an improvement ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198003000-00004

    authors: Schleuning AJ,Johnson RM,Vernon JA

    更新日期:1980-03-01 00:00:00

  • Systemic Aminoglycosides-Induced Vestibulotoxicity in Humans.

    abstract:OBJECTIVES:This systematic review aimed to investigate the prevalence and characteristics of vestibular adverse effects of aminoglycoside (AG) therapy in humans and to analyze objective vestibular tests for the detection of AG-induced vestibulotoxicity. DESIGN:PubMed, Cochrane Database, Web of Science, and reference l...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0000000000000458

    authors: Van Hecke R,Van Rompaey V,Wuyts FL,Leyssens L,Maes L

    更新日期:2017-11-01 00:00:00

  • The impact of measurement goals on the design specification for outcome measures.

    abstract::No outcome measure has universal validity and applicability. When designing, promulgating or selecting a particular instrument, audiologists should take care to consider and specify the detailed purposes to which the measure will be directed, and the particular populations to which it will be applied. Scales that have...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200008001-00013

    authors: Gatehouse S

    更新日期:2000-08-01 00:00:00

  • Evaluation of Speed and Accuracy of Next-Generation Auditory Steady State Response and Auditory Brainstem Response Audiometry in Children With Normal Hearing and Hearing Loss.

    abstract:OBJECTIVES:The first objective of this study was to compare the predicted audiometric thresholds obtained by auditory steady state response (ASSR) and auditory brainstem response (ABR) in infants and toddlers when both techniques use optimal stimuli and detection algorithms. This information will aid in determining the...

    journal_title:Ear and hearing

    pub_type: 杂志文章,多中心研究

    doi:10.1097/AUD.0000000000000580

    authors: Sininger YS,Hunter LL,Hayes D,Roush PA,Uhler KM

    更新日期:2018-11-01 00:00:00

  • Current state of knowledge: outcomes research in children with mild to severe hearing impairment--approaches and methodological considerations.

    abstract::This paper will provide a backdrop to the others in this section on outcomes of children with mild to moderate sensorineural hearing loss. Our objective here is to provide an overview of the research approaches used to study the outcomes of these children to provide guidance for future studies of children with mild to...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0b013e318157f093

    authors: Tomblin B,Hebbeler K

    更新日期:2007-12-01 00:00:00

  • Noise levels of electronic arcade games: a potential hearing hazard to children.

    abstract::A measurement of noise exposure levels of players of electronic games was made in two small arcades using a noise dosimeter. Two different measurements were made, at normal operating levels and maximum possible levels. The results showed that excessive exposure levels were possible on arcade games and that these level...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198307000-00005

    authors: Plakke BL

    更新日期:1983-07-01 00:00:00

  • Evaluation of streamlined programming procedures for the Nucleus cochlear implant with the Contour electrode array.

    abstract:OBJECTIVE:The objective of this study was to evaluate streamlined programming procedures for the Nucleus cochlear implant system with the Contour electrode array. DESIGN:Phase 1 involved an examination of the clinical MAPs for the first 103 recipients implanted with the Contour electrode array in the Melbourne Cochlea...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000188201.86799.01

    authors: Plant K,Law MA,Whitford L,Knight M,Tari S,Leigh J,Pedley K,Nel E

    更新日期:2005-12-01 00:00:00

  • Changes in transient-evoked otoacoustic emissions in the first month of life.

    abstract:OBJECTIVE:Current Joint Committee on Infant Hearing guidelines recommend the use of transient-evoked otoacoustic emissions (TEOAEs) as a screening tool to identify hearing loss for newborns cared for in the well-baby nursery. Newborns who do not pass the TEOAE screen before leaving the hospital are typically rescreened...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31819c4000

    authors: Prieve BA,Hancur-Bucci CA,Preston JL

    更新日期:2009-06-01 00:00:00

  • Effects of interaural pitch matching and auditory image centering on binaural sensitivity in cochlear implant users.

    abstract:OBJECTIVES:In bilateral cochlear implant users, electrodes mapped to the same frequency range in each ear may stimulate different places in each cochlea due to an insertion depth difference of electrode arrays. This interaural place of stimulation mismatch can lead to problems with auditory image fusion and sensitivity...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000135

    authors: Kan A,Litovsky RY,Goupell MJ

    更新日期:2015-05-01 00:00:00

  • Audiologic manifestations of patients with post-treatment Lyme disease syndrome.

    abstract:OBJECTIVE:The purpose of this study was to characterize auditory function in patients diagnosed with post-treatment Lyme disease syndrome (PTLDS). DESIGN:Eighteen patients with PTLDS were evaluated and compared to a normal population. Evaluations consisted of pure tone and speech thresholds, word recognition (WRS), ac...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000100205.25774.5F

    authors: Shotland LI,Mastrioanni MA,Choo DL,Szymko-Bennett YM,Dally LG,Pikus AT,Sledjeski K,Marques A

    更新日期:2003-12-01 00:00:00

  • Behavioral Pure-Tone Threshold Shifts Caused by Tympanic Membrane Electrodes.

    abstract:OBJECTIVE:To determine whether tympanic membrane (TM) electrodes induce behavioral pure-tone threshold shifts. DESIGN:Pure-tone thresholds (250 to 8000 Hz) were measured twice in test (n = 18) and control (n = 10) groups. TM electrodes were placed between first and second threshold measurements in the test group, wher...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000275

    authors: Smith SB,Lichtenhan J,Cone B

    更新日期:2016-07-01 00:00:00