Abstract:
OBJECTIVES:Vestibular reflexes have traditionally formed the cornerstone of vestibular evaluation, but perceptual tests have recently gained attention for use in research studies and potential clinical applications. However, the unknown reliability of perceptual thresholds limits their current importance. This is addressed here by establishing the test-retest reliability of vestibular perceptual testing. DESIGN:Perceptual detection thresholds to earth-vertical, yaw-axis rotations were collected in 15 young healthy people. Participants were tested at two time intervals (baseline, 5 to 14 days later) using an adaptive psychophysical procedure. RESULTS:Thresholds to 1 Hz rotations ranged from 0.69 to 2.99°/s (mean: 1.49°/s; SD: 0.63). They demonstrated an excellent intraclass correlation (0.92; 95% confidence interval: 0.77 to 0.97) with a minimum detectable difference of 0.45°/s. CONCLUSIONS:The excellent test-retest reliability of perceptual vestibular testing supports its use as a research tool and motivates further exploration for its use as a novel clinical technique.
journal_name
Ear Hearjournal_title
Ear and hearingauthors
Lee TL,Shayman CS,Oh Y,Peterka RJ,Hullar TEdoi
10.1097/AUD.0000000000000859subject
Has Abstractpub_date
2020-11-01 00:00:00pages
1772-1774issue
6eissn
0196-0202issn
1538-4667pii
00003446-202011000-00032journal_volume
41pub_type
杂志文章相关文献
EAR AND HEARING文献大全abstract:OBJECTIVE:The primary purpose of this study was to determine the distortion product otoacoustic emission (DPOAE) and noise response characteristics in a large sample of older adults. Another purpose was to evaluate how specific absolute DPOAE levels or DPOAE/Noise ratios differentiated hearing status in these individua...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.AUD.0000051847.66944.2B
更新日期:2003-02-01 00:00:00
abstract::The present study was designed to investigate the effects of reference microphone location on probe tube microphone measures of hearing aid response. The reference microphone of a clinical probe tube microphone system was located either at a position on the cheek (position A) or in close proximity to the microphone of...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199010000-00001
更新日期:1990-10-01 00:00:00
abstract:OBJECTIVES:Patients suffering from vestibular disorders (VD) often present with impairments in cognitive domains such as visuospatial ability, memory, executive function, attention, and processing speed. These symptoms can be attributed to extensive vestibular projections throughout the cerebral cortex and subcortex on...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000748
更新日期:2020-01-01 00:00:00
abstract:OBJECTIVE:In hearing aid research, it is commonplace to combine data across subjects whose hearing aids were provided in different service delivery models. There is reason to question whether these types of patients are always similar enough to justify this practice. To explore this matter, this investigation evaluated...
journal_title:Ear and hearing
pub_type: 杂志文章,多中心研究
doi:10.1097/01.aud.0000188188.01311.0b
更新日期:2005-12-01 00:00:00
abstract:OBJECTIVE:The main objective of this study was to assess the correlation of auditory event related potential (ERP) measures with behavioral assessment data to identify if ERPs including mismatch negativity (MMN) can be used to categorize cochlear implant patients into good and poor performers. DESIGN:We investigated a...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200412000-00008
更新日期:2004-12-01 00:00:00
abstract::One hundred eighty-four deaf children were presented auditory, visual (speechreading), and combined stimuli. Some subjects showed an enhancement of their processing abilities in the combined mode, some demonstrated no improvement, and others yielded reduced scores. A method of data analysis is proposed which could con...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198005000-00003
更新日期:1980-05-01 00:00:00
abstract:OBJECTIVES:Multiple auditory steady state responses (ASSRs) will likely be included in the diagnostic test battery for estimating infant auditory thresholds in the near future; however, the effects of single- versus multiple-stimulus presentation in infants has never been investigated. In adults, there are no interacti...
journal_title:Ear and hearing
pub_type: 临床试验,杂志文章
doi:10.1097/AUD.0b013e3181ff352c
更新日期:2011-05-01 00:00:00
abstract:OBJECTIVE:The aim of the present study was to examine audiovisual speech integration in cochlear-implanted children and in normally hearing children exposed to degraded auditory stimuli. Previous studies have shown that speech perception in cochlear-implanted users is biased toward the visual modality when audition and...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e3182670993
更新日期:2013-01-01 00:00:00
abstract:OBJECTIVE:A new speech processing concept and its implementation cochlear implant neural net, simulation and stimulation (CINSTIM), for cochlear implant systems is currently under investigation. The main objectives of this new strategy are to improve speech perception within the early rehabilitation period for prelingu...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199602000-00009
更新日期:1996-02-01 00:00:00
abstract:OBJECTIVE:The main objective was to investigate whether the broadening and narrowing of formant bandwidths had a significant effect on the identification of vowels often confused by Nucleus cochlear implant recipients using the Spectral Peak (SPEAK) speech coding strategy. Specifically, identification performance for s...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199712000-00006
更新日期:1997-12-01 00:00:00
abstract:OBJECTIVES:New tinnitus therapies are being developed and marketed that target the patient's tinnitus frequency. This frequency is estimated clinically by pitch matching, which has the patient identify the pure tone that is closest to the perceived tinnitus frequency. Though widely used, pitch matching is heavily criti...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000081
更新日期:2014-11-01 00:00:00
abstract:OBJECTIVES:The active middle ear implant Vibrant Soundbridge® was originally designed to treat mild-to-severe sensorineural hearing losses. The floating mass transducer (FMT) is crimped onto the long incus process. The procedure is termed incus vibroplasty to distinguish from other attachment sites or stimulus modi for...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000078
更新日期:2015-01-01 00:00:00
abstract:OBJECTIVES:Although it has been well established that the prevalence of and severity of hearing loss increase with age, the contribution of familial factors to age-related hearing loss cannot be quantified. This is largely because hearing loss in older people has both genetic and environmental contributions. As environ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31817349d6
更新日期:2008-08-01 00:00:00
abstract:OBJECTIVE:Inability to understand speech in noise has been cited repeatedly as the principal complaint of hearing aid users. While data exist documenting the benefit provided by hearing aids with directional microphones when listening to speech in noise, little work has been done to develop a standard clinical protocol...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.aud.0000121236.56217.8f
更新日期:2004-04-01 00:00:00
abstract::Peripheral auditory sensitivity is documented over a 5-year period on 4 cases with otodental dysplasia. Age of onset is noted for the proband and indicates that onset of this progressive hearing loss occurs as early as the first decade. Findings suggest that the hearing loss plateaus by the fourth decade, resulting in...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198103000-00007
更新日期:1981-03-01 00:00:00
abstract::Three experiments evaluated steady state and transient auditory evoked potentials (EPs) to tones that were sinusoidally modulated in frequency and to tones that alternated between two frequencies with a linear ramp. The steady state responses to sinusoidal FM were small and difficult to record at both the first and se...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198906000-00003
更新日期:1989-06-01 00:00:00
abstract::In contrast to the transient (N1-P2) and steady-state (<20 Hz) cortical responses, neither the transient (auditory brain stem response) nor the steady-state (80 Hz) brain stem responses show the binaural masking level difference (BMLD). This study determined behavioral and 40-Hz auditory steady-state response (ASSR) B...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e3181b61cc8
更新日期:2009-12-01 00:00:00
abstract:INTRODUCTION:Cochlear implantation (CI) in subjects with unilateral profound sensorineural hearing loss was investigated. The authors of the present study demonstrated the binaural auditory outcomes in a 12- and 36-month prospective cohort outcome study. The present study aimed to do a long-term (LT) evaluation of the ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000359
更新日期:2017-01-01 00:00:00
abstract:OBJECTIVE:Evaluating the effect of anxiety and depression on clinical measures of general health, tinnitus-specific quality of life, and coping abilities. DESIGN:Two hundred sixty-five chronic, subjective tinnitus sufferers were divided into four psychological symptom groups according to cut-off scores on anxiety and ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e3181888f83
更新日期:2008-12-01 00:00:00
abstract::No outcome measure has universal validity and applicability. When designing, promulgating or selecting a particular instrument, audiologists should take care to consider and specify the detailed purposes to which the measure will be directed, and the particular populations to which it will be applied. Scales that have...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200008001-00013
更新日期:2000-08-01 00:00:00
abstract::The use of auditory brain stem response (ABR) represents a new dimension in auditory and neurological pediatric assessment. Because the ABR may be altered by stimulus and procedural variables, the lack of an established standard has reduced its clinical efficiency. This paper describes a suggested ABR protocol for inf...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198209000-00006
更新日期:1982-09-01 00:00:00
abstract::Some initial experiences are described in which ear canal probe tube microphone measurements are used to determine hearing aid settings for children. Decisions are based upon ideas developed by Seewald and Ross (in Amplification for the Hearing Impaired, New York: Grune & Stratton, 1988: 213-267) and Seewald, Ross, an...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198910000-00002
更新日期:1989-10-01 00:00:00
abstract:OBJECTIVES:The first objective was to examine factors that could be predictive of postoperative unilateral (cochlear implant alone) speech recognition ability in a group of subjects with greater degrees of preoperative acoustic hearing than has been previously examined. Second, the study aimed to identify factors predi...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000233
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVES:Jervell and Lange-Nielsen syndrome (JLNS) is a rare cause of autosomal recessive inherited deafness. JLNS patients are candidates for cochlear implantation, and represent a group that needs special attention and precautions. The aim of this article is to draw some guidelines for dealing with these patients, ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/aud.0b013e3181645393
更新日期:2008-04-01 00:00:00
abstract::This study is a follow-up of an 1980-1982 study that examined the occurrence of risk factors and the patterns of identification and habilitation in a group of hearing-impaired infants from an urban setting. Current findings covering the period 1983-1988, indicate that only one out of three hearing-impaired infants can...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199006000-00006
更新日期:1990-06-01 00:00:00
abstract:OBJECTIVE:Despite the many studies on the associated risk of cardiovascular and cerebrovascular events in patients with hypercholesterolemia (HCh), an association between HCh and the development of idiopathic sudden sensorineural hearing loss (ISSNHL) has been examined in only a few case-control studies. We tested the ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e3182a76637
更新日期:2014-03-01 00:00:00
abstract::The primary purpose of this study was to determine list equivalency of Harris' revision of the CID Everyday Sentence Lists under three signal-to-noise ratios: O dB, --3 dB, and --6 dB. On the basis of list means, nonsignificant groupings of lists were found at each noise level; however, lists were not equivalent at an...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198309000-00006
更新日期:1983-09-01 00:00:00
abstract:OBJECTIVE:The performance of four insert earplugs was evaluated by determining the Noise Reduction Rating (NRR) and the Subject-Fit Noise Reduction Rating [NRR(SF)]. The NRR and NRR(SF) were calculated from real-ear attenuation at threshold (REAT) data collected using the experimenter-fit protocol described in the now-...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200006000-00005
更新日期:2000-06-01 00:00:00
abstract:OBJECTIVE:The present study was aimed to examine the relationship between psychophysical performance in temporal and spectral resolution and Mandarin tone recognition in noise by cochlear-implant (CI) listeners. DESIGN:Seventeen Nucleus-24 implant users, 10 postlingually deafened and 7 prelingually deafened, participa...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e318031512c
更新日期:2007-04-01 00:00:00
abstract:OBJECTIVES:The impact of social distancing on communication and psychosocial variables among individuals with hearing impairment during COVID-19 pandemic. It was our concern that patients who already found themselves socially isolated (Wie et al. 2010) as a result of their hearing loss would be perhaps more susceptible...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000991
更新日期:2020-12-22 00:00:00