Abstract:
OBJECTIVES:Although it has been shown previously that changes in temporal coding produce changes in pitch in all cochlear regions, research has suggested that temporal coding might be best encoded in relatively apical locations. The authors hypothesized that although temporal coding may provide useable information at any cochlear location, low rates of stimulation might provide better sound quality in apical regions that are more likely to encode temporal information in the normal ear. In the present study, sound qualities of single electrode pulse trains were scaled to provide insight into the combined effects of cochlear location and stimulation rate on sound quality. DESIGN:Ten long-term users of MED-EL cochlear implants with 31-mm electrode arrays (Standard or FLEX) were asked to scale the sound quality of single electrode pulse trains in terms of how "Clean," "Noisy," "High," and "Annoying" they sounded. Pulse trains were presented on most electrodes between 1 and 12 representing the entire range of the long electrode array at stimulation rates of 100, 150, 200, 400, or 1500 pulses per second. RESULTS:Although high rates of stimulation are scaled as having a Clean sound quality across the entire array, only the most apical electrodes (typically 1 through 3) were considered Clean at low rates. Low rates on electrodes 6 through 12 were not rated as Clean, whereas the low-rate quality of electrodes 4 and 5 were typically in between. Scaling of Noisy responses provided an approximately inverse pattern as Clean responses. High responses show the trade-off between rate and place of stimulation on pitch. Because High responses did not correlate with Clean responses, subjects were not rating sound quality based on pitch. CONCLUSIONS:If explicit temporal coding is to be provided in a cochlear implant, it is likely to sound better when provided apically. In addition, the finding that low rates sound clean only at apical places of stimulation is consistent with previous findings that a change in rate of stimulation corresponds to an equivalent change in perceived pitch at apical locations. Collectively, the data strongly suggest that temporal coding with a cochlear implant is optimally provided by electrodes placed well into the second cochlear turn.
journal_name
Ear Hearjournal_title
Ear and hearingauthors
Landsberger DM,Vermeire K,Claes A,Van Rompaey V,Van de Heyning Pdoi
10.1097/AUD.0000000000000250subject
Has Abstractpub_date
2016-05-01 00:00:00pages
e149-59issue
3eissn
0196-0202issn
1538-4667journal_volume
37pub_type
杂志文章相关文献
EAR AND HEARING文献大全abstract:OBJECTIVE:Research was conducted to assess multichannel saliency with the Ineraid cochlear prosthesis. The goal was to determine whether tonotopically ordered stimulation benefits speech reception. DESIGN:In a single high-performing subject, changes in speech reception were studied during two dramatic alterations to t...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199510000-00002
更新日期:1995-10-01 00:00:00
abstract:OBJECTIVE:The purpose of the study was to compare real-ear to coupler difference (RECD) values in the right and left ear of adults using three earmold configurations. DESIGN:The RECD was obtained from both ears of 18 normal hearing adults by subtracting the HA2 2-cc coupler response from the real-ear response using an...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200506000-00005
更新日期:2005-06-01 00:00:00
abstract:OBJECTIVE:To examine differences among various test protocols on the fail rate at hospital discharge for infants in the well-baby nursery (WBN) and neonatal intensive care unit (NICU) who received hearing screening through a universal newborn hearing screening demonstration project. DESIGN:The outcomes of several scre...
journal_title:Ear and hearing
pub_type: 杂志文章,多中心研究
doi:10.1097/00003446-200004000-00007
更新日期:2000-04-01 00:00:00
abstract::Botulism poisoning results in a presynaptic failure of neuromuscular transmission, and may be expected to impair Eustachian tube and stapedius reflex function. The audiologic findings in five normal-hearing patients with type A botulism poisoning are presented. Results were varied. Two patients demonstrated type B or ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199108000-00007
更新日期:1991-08-01 00:00:00
abstract::This paper describes the first phase in the development of the Connected Speech Test (CST). This test of intelligibility of everyday speech has been developed primarily for use as a criterion measure in investigations of hearing aid benefit. The test consists of 48 passages of conversationally produced connected speec...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198710001-00010
更新日期:1987-10-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the pr...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000562
更新日期:2018-11-01 00:00:00
abstract:OBJECTIVES:Interference between a target and simultaneous maskers occurs both at the cochlear level through energetic masking and more centrally through informational masking (IM). Hence, quantifying the amount of IM requires a strict control of the energetic component. Presenting target and maskers on different sides ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000116
更新日期:2015-05-01 00:00:00
abstract:OBJECTIVE:To investigate the applicability of the self-report inventory, Satisfaction with Amplification in Daily Life (SADL), at 2 wk postfitting. DESIGN:The SADL was completed by two groups of hearing aid users, one fitted 2 wk before completion, the other at least 1 yr before. All SADLs were completed as a paper an...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200108000-00008
更新日期:2001-08-01 00:00:00
abstract:OBJECTIVES:Temporal envelope and periodicity components (TEPC) in the speech signal have potentials to offer important cues for speech recognition especially in tonal languages. The aims of this study are: (i) to investigate the degree of contributions of TEPC to lexical tone identification in Cantonese; and (ii) to in...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31803153ac
更新日期:2007-04-01 00:00:00
abstract:OBJECTIVE:This paper reports some preliminary findings from patients, implanted at the University of Iowa, using the Advanced Bionics Clarion cochlear implant (version 1.0). We compared the performance of patients using both simultaneous analog and nonsimultaneous pulsatile processing strategies. The performance of Cla...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199612000-00008
更新日期:1996-12-01 00:00:00
abstract:OBJECTIVE:This study completed an evidence-based practice systematic review of the nonacoustic benefits for adult patients receiving bone-anchored hearing aid(s) (BAHAs) relative to other forms of amplification (i.e., none, bone-conduction hearing aids [BCHAs], or air-conduction hearing aids [ACHAs]). DESIGN:Systemati...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/01.aud.0000240635.70277.3f
更新日期:2006-12-01 00:00:00
abstract:OBJECTIVES:Although directional microphones on a hearing aid provide a signal-to-noise ratio benefit in a noisy background, the amount of benefit is dependent on how close the signal of interest is to the front of the user. It is assumed that when the signal of interest is off-axis, users can reorient themselves to the...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000053
更新日期:2014-09-01 00:00:00
abstract:OBJECTIVES:A postlingually implanted adult typically develops hearing with an intact auditory system, followed by periods of deafness (or near deafness) and adaptation to the implant. For an early implanted child whose brain is highly plastic, the auditory system matures with consistent input from a cochlear implant. I...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000463
更新日期:2018-01-01 00:00:00
abstract::Auditory brain stem response waveforms, derived from normal ears, were analyzed with a computer-based digital filtering program as a means of systematically evaluating the effects of phase-shift distortion. Off-line analysis involved the stimulated responses of a Butterworth-type filter at five high-pass and four low-...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198612000-00006
更新日期:1986-12-01 00:00:00
abstract:OBJECTIVES:Conventional assessments of outcomes in deaf children with cochlear implants (CIs) have focused primarily on endpoint or product measures of speech and language. Little attention has been devoted to understanding the basic underlying core neurocognitive factors involved in the development and processing of s...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e3181ffd58e
更新日期:2011-02-01 00:00:00
abstract:OBJECTIVES:There are no nationally representative hearing loss (HL) prevalence data available for Canadian youth using direct measurements. The present study objectives were to estimate national prevalence of HL using audiometric pure-tone thresholds (0.5 to 8 kHz) and or distortion product otoacoustic emissions (DPOAE...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000345
更新日期:2017-01-01 00:00:00
abstract::The ability of aural acoustic immittance measures and validated pneumatic otoscopy to identify middle ear effusion (MEE) was determined for a group of children with chronic or recurrent otitis media. The measures were made immediately prior to surgery for placement of tympanostomy tubes, with the validating diagnosis ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199408000-00005
更新日期:1994-08-01 00:00:00
abstract:OBJECTIVE:It is widely recognized by hearing aid users and audiologists that a period of auditory acclimatization and adjustment is needed for new users to become accustomed to their devices. The aim of the present study was to test the idea that auditory acclimatization and adjustment to hearing aids involves a proces...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000366
更新日期:2017-03-01 00:00:00
abstract:OBJECTIVES:The impact of social distancing on communication and psychosocial variables among individuals with hearing impairment during COVID-19 pandemic. It was our concern that patients who already found themselves socially isolated (Wie et al. 2010) as a result of their hearing loss would be perhaps more susceptible...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000991
更新日期:2020-12-22 00:00:00
abstract::Coupler output levels were obtained for six repeated placements of a TDH-49 earphone in a P/N 51 cushion on a NBS 9A coupler and a B-71 and B-72 bone vibrator on a mechanical coupler from 250 to 4000 Hz using experienced (N = 9) and untrained subjects (N = 9) who were later trained. The largest minus the smallest coup...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198608000-00009
更新日期:1986-08-01 00:00:00
abstract:OBJECTIVES:The objectives of this research were to develop and evaluate a self-report questionnaire (the Emotional Communication in Hearing Questionnaire or EMO-CHeQ) designed to assess experiences of hearing and handicap when listening to signals that contain vocal emotion information. DESIGN:Study 1 involved interne...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000611
更新日期:2019-03-01 00:00:00
abstract:OBJECTIVES:To assess the association between hearing impairment and health-related quality of life (HRQOL) in an older population, using the self-administered 36-item Short-Form Health Survey (SF-36). DESIGN:Participants of the Blue Mountains Hearing Study (BMHS, N = 2956) attended a comprehensive interview and hearin...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31803126b6
更新日期:2007-04-01 00:00:00
abstract:OBJECTIVES:To evaluate the influence of auditory cues on postural sway in normal-hearing (NH) individuals, hearing-impaired individuals with vestibular impairment (HIVL), or hearing-impaired (HI) individuals without vestibular impairment. DESIGN:Thirty-two participants received a hearing and a vestibular evaluation (v...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000720
更新日期:2019-11-01 00:00:00
abstract:OBJECTIVES:The ability of human listeners to identify consonants (presented as nonsense syllables) on the basis of primarily temporal information was compared with the predictions of a simple model based on the amplitude modulation spectra of the stimuli calculated for six octave-spaced carrier frequencies (250 to 8000...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31817e73ef
更新日期:2008-10-01 00:00:00
abstract::This study reviews audiologic findings on cases of hearing-impaired elderly adults who were matched on the basis of peripheral hearing loss and who were divided into cochlear and retrocochlear groups on the basis of auditory brain stem response (ABR) test results. ABR test results were compared to other audiologic tes...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199102000-00008
更新日期:1991-02-01 00:00:00
abstract:OBJECTIVE:To determine the maximum stimulus levels at which a measured auditory steady-state response (ASSR) can be assumed to be a reliable measure of auditory thresholds. DESIGN:ASSR thresholds were measured at octave frequencies from 500 to 4000 Hz in 10 subjects with profound hearing loss. These subjects provided ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.aud.0000130801.96611.6b
更新日期:2004-06-01 00:00:00
abstract:OBJECTIVE:Establishing methods for topical administration of drugs to the inner ear have great clinical relevance and potential even in a relatively short perspective. To evaluate the efficacy of sodium hyaluronate (HYA) as a vehicle for drugs that could be used for treatment of inner ear disorders. METHODS:The cochle...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31818ff98e
更新日期:2009-02-01 00:00:00
abstract:OBJECTIVES:New tinnitus therapies are being developed and marketed that target the patient's tinnitus frequency. This frequency is estimated clinically by pitch matching, which has the patient identify the pure tone that is closest to the perceived tinnitus frequency. Though widely used, pitch matching is heavily criti...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000081
更新日期:2014-11-01 00:00:00
abstract:OBJECTIVES:Preliminary evidence suggests that children with hearing loss experience elevated levels of chronic fatigue compared with children with normal hearing. Chronic fatigue is associated with decreased academic performance in many clinical populations. Children with cochlear implants as a group exhibit deficits i...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000242
更新日期:2016-03-01 00:00:00
abstract::The relationship between otitis media with effusion (OME) at preschool age and performance on five tests of auditory perception was studied in 89 school-age children who had OME histories well documented from participation in serial screening for OME at 2-4 yr of age. The tests used at 7.5-8 yr of age were: speech-in-...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199406000-00003
更新日期:1994-06-01 00:00:00