An investigation of the applicability of the inventory, satisfaction with amplification in daily life, at 2 weeks post hearing aid fitting.

Abstract:

OBJECTIVE:To investigate the applicability of the self-report inventory, Satisfaction with Amplification in Daily Life (SADL), at 2 wk postfitting. DESIGN:The SADL was completed by two groups of hearing aid users, one fitted 2 wk before completion, the other at least 1 yr before. All SADLs were completed as a paper and pencil exercise, without involvement of an audiologist or other clinic staff. All the aid users were Government funded, all were fitted with the same model hearing aid, all were over the age of 60 yr, and all were fitted and counselled by the same two audiologists. Comparisons were made of the two groups' scores on each subscale and Global score, as well as on scores for each individual question. RESULTS:All scores for subscales, Global score, and individual questions were higher at 2 wk postfitting than at 1 yr. Significant differences were found for subscales Positive Effect (p < 0.05), Service and Cost (p < 0.025), Negative Features (p < 0.001), as well as for the Global score (p < 0.001). The only subscale not resulting in a significant difference was Personal Image (p > 0.10). It was noted that Negative Features, such as background interference, acoustic feedback, and problems with telephone use, apparently take longer to be observed than Positive Effects such as improved communication and good sound quality. By contrast with some other reported studies, these results all display a reduction in self-reported outcome, rather than stability, or even improvement, over time. Among other possibilities, this finding may suggest the SADL measures something different to that measured by other inventories. CONCLUSIONS:The results of this investigation suggest that, if the aim is to predict long-term satisfaction with aid fitting, 2 wk postfitting is too early for meaningful application of the SADL as an outcome measure. It is possible that an earlier stability in SADL scores might be obtained by inclusion of additional questions aimed at earlier detection of negative features. Such inclusions may detract from one of the SADL's advantages, namely its brevity. It also is suggested that the long-term value of self-report methods will depend on development of rigorous and scientifically acceptable administration procedures, including appropriate times for application.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

McLeod B,Upfold L,Broadbent C

doi

10.1097/00003446-200108000-00008

subject

Has Abstract

pub_date

2001-08-01 00:00:00

pages

342-7

issue

4

eissn

0196-0202

issn

1538-4667

journal_volume

22

pub_type

杂志文章
  • Effects of interaural pitch matching and auditory image centering on binaural sensitivity in cochlear implant users.

    abstract:OBJECTIVES:In bilateral cochlear implant users, electrodes mapped to the same frequency range in each ear may stimulate different places in each cochlea due to an insertion depth difference of electrode arrays. This interaural place of stimulation mismatch can lead to problems with auditory image fusion and sensitivity...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000135

    authors: Kan A,Litovsky RY,Goupell MJ

    更新日期:2015-05-01 00:00:00

  • Parents' preferences for services for children with hearing loss: a conjoint analysis study.

    abstract:OBJECTIVE:Early identification of permanent childhood hearing loss through universal newborn hearing screening is rapidly becoming a standard of care. However, it is well recognized that hearing screening must be embedded within a comprehensive system of rehabilitation and parent support services. This study was undert...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e318157676d

    authors: Fitzpatrick E,Coyle DE,Durieux-Smith A,Graham ID,Angus DE,Gaboury I

    更新日期:2007-12-01 00:00:00

  • Qualities of Single Electrode Stimulation as a Function of Rate and Place of Stimulation with a Cochlear Implant.

    abstract:OBJECTIVES:Although it has been shown previously that changes in temporal coding produce changes in pitch in all cochlear regions, research has suggested that temporal coding might be best encoded in relatively apical locations. The authors hypothesized that although temporal coding may provide useable information at a...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000250

    authors: Landsberger DM,Vermeire K,Claes A,Van Rompaey V,Van de Heyning P

    更新日期:2016-05-01 00:00:00

  • Air-Conducted Vestibular Evoked Myogenic Potential Testing in Children, Adolescents, and Young Adults: Thresholds, Frequency Tuning, and Effects of Sound Exposure.

    abstract:OBJECTIVES:Pediatric vestibular evaluations incorporate cervical and ocular vestibular evoked myogenic potential (c- and oVEMP, respectively) testing; however, in children, c- and oVEMP thresholds have been minimally investigated and frequency tuning is unknown. Children are also at risk for unsafe sound exposure secon...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000607

    authors: Rodriguez AI,Thomas MLA,Janky KL

    更新日期:2019-01-01 00:00:00

  • Auditory Distraction and Acclimatization to Hearing Aids.

    abstract:OBJECTIVE:It is widely recognized by hearing aid users and audiologists that a period of auditory acclimatization and adjustment is needed for new users to become accustomed to their devices. The aim of the present study was to test the idea that auditory acclimatization and adjustment to hearing aids involves a proces...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000366

    authors: Dawes P,Munro KJ

    更新日期:2017-03-01 00:00:00

  • Children's recognition of spectrally degraded cartoon voices.

    abstract:OBJECTIVES:Although the spectrally degraded input provided by cochlear implants (CIs) is sufficient for speech perception in quiet, it poses problems for talker identification. The present study examined the ability of normally hearing (NH) children and child CI users to recognize cartoon voices while listening to spec...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3182a468d0

    authors: van Heugten M,Volkova A,Trehub SE,Schellenberg EG

    更新日期:2014-01-01 00:00:00

  • Evaluation of a tinnitus masking program: a follow-up study of 598 patients.

    abstract::A follow-up study of two groups of tinnitus patients was conducted in an attempt to evaluate the tinnitus masking program. Results are discussed separately for a group of patients seen during the first three years of the program (1976 through 1978) and during the last year (1979). These results suggest an improvement ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198003000-00004

    authors: Schleuning AJ,Johnson RM,Vernon JA

    更新日期:1980-03-01 00:00:00

  • A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in nucleus 24 cochlear implant users.

    abstract:OBJECTIVE:The primary goal of this study was to examine changes that may occur in electrode impedance, electrically evoked compound action potential (EAP) threshold and slope of the EAP growth function, and behavioral measures of threshold T-level) and maximum comfort (C-level) over time in both adult and child cochlea...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200112000-00004

    authors: Hughes ML,Vander Werff KR,Brown CJ,Abbas PJ,Kelsay DM,Teagle HF,Lowder MW

    更新日期:2001-12-01 00:00:00

  • Speech perception using maps based on neural response telemetry measures.

    abstract:OBJECTIVE:To determine how speech perception is affected for Nucleus cochlear implant users when their speech processor is programmed using neural response telemetry (NRT) measures rather than traditional behavioral estimates of threshold and maximum comfort level. DESIGN:Electrically evoked compound action potential ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200202001-00009

    authors: Seyle K,Brown CJ

    更新日期:2002-02-01 00:00:00

  • Identifying dead regions in the cochlea: psychophysical tuning curves and tone detection in threshold-equalizing noise.

    abstract:OBJECTIVE:Recent studies indicate that high-frequency amplification may provide little benefit for listeners with moderate-to-severe high-frequency hearing loss, and may even reduce speech recognition. Moore and colleagues have proposed a direct link between this lack of benefit and the presence of regions of nonfuncti...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000058148.27540.D9

    authors: Summers V,Molis MR,Müsch H,Walden BE,Surr RK,Cord MT

    更新日期:2003-04-01 00:00:00

  • Family Environment in Children With Hearing Aids and Cochlear Implants: Associations With Spoken Language, Psychosocial Functioning, and Cognitive Development.

    abstract:OBJECTIVES:To examine differences in family environment and associations between family environment and key speech, language, and cognitive outcomes in samples of children with normal hearing and deaf and hard-of-hearing (DHH) children who use hearing aids and cochlear implants. DESIGN:Thirty families of children with...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000811

    authors: Holt RF,Beer J,Kronenberger WG,Pisoni DB,Lalonde K,Mulinaro L

    更新日期:2020-07-01 00:00:00

  • Maturation of the contralaterally recorded auditory brain stem response.

    abstract::Ipsilaterally and contralaterally recorded auditory brain stem responses to 80 dB nHL clicks were recorded from 37 infants, aged 2 weeks to 20 mo and from six adults, all with normal auditory function. With increasing age, contralateral waves A, B, C, and D and ipsilateral waves III and V decreased in latency, with th...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199106000-00002

    authors: Stapells DR,Mosseri M

    更新日期:1991-06-01 00:00:00

  • Development of the Connected Speech Test (CST).

    abstract::This paper describes the first phase in the development of the Connected Speech Test (CST). This test of intelligibility of everyday speech has been developed primarily for use as a criterion measure in investigations of hearing aid benefit. The test consists of 48 passages of conversationally produced connected speec...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198710001-00010

    authors: Cox RM,Alexander GC,Gilmore C

    更新日期:1987-10-01 00:00:00

  • The use of averaged electrode voltages to assess the function of nucleus internal cochlear implant devices in children.

    abstract::Averaged electrode voltages (AEVs) provide an objective measure of the output of the Nucleus multichannel cochlear implant device. AEVs are the peak-to-peak voltages of each electrode in the internal array and are recorded from electrodes placed on the scalp. This article summarizes average voltage data for 25 childre...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199404000-00007

    authors: Mahoney MJ,Proctor LA

    更新日期:1994-04-01 00:00:00

  • Peripheral Auditory Involvement in Childhood Listening Difficulty.

    abstract:OBJECTIVES:This study tested the hypothesis that undetected peripheral hearing impairment occurs in children with idiopathic listening difficulties (LiDs), as reported by caregivers using the Evaluation of Children"s Listening and Processing Skills (ECLiPS) validated questionnaire, compared with children with typically...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000899

    authors: Hunter LL,Blankenship CM,Lin L,Sloat NT,Perdew A,Stewart H,Moore DR

    更新日期:2020-06-25 00:00:00

  • Effect of electrode impedance on spread of excitation and pitch perception using electrically coupled "dual-electrode" stimulation.

    abstract:OBJECTIVES:In newer-generation Cochlear Ltd. cochlear implants, two adjacent electrodes can be electrically coupled to produce a single contact or "dual electrode" (DE). The goal of the present study was to evaluate whether relatively large impedance differences (>3.0 kOhms) between coupled electrodes affect the excita...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000098

    authors: Hughes ML,Baudhuin JL,Goehring JL

    更新日期:2015-03-01 00:00:00

  • A systematic review of the nonacoustic benefits of bone-anchored hearing AIDS.

    abstract:OBJECTIVE:This study completed an evidence-based practice systematic review of the nonacoustic benefits for adult patients receiving bone-anchored hearing aid(s) (BAHAs) relative to other forms of amplification (i.e., none, bone-conduction hearing aids [BCHAs], or air-conduction hearing aids [ACHAs]). DESIGN:Systemati...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/01.aud.0000240635.70277.3f

    authors: Johnson CE,Danhauer JL,Reith AC,Latiolais LN

    更新日期:2006-12-01 00:00:00

  • Hormonal influence on auditory function.

    abstract::This study examined whether female subjects who had balanced hormonal profiles and who were experiencing the characteristic fluctuation in estrogen and progesterone levels exhibited changes in auditory function unlike subjects who were using a low-dose combined estrogen and progesterone steroid. Threshold data at 500,...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198007000-00008

    authors: Cox JR

    更新日期:1980-07-01 00:00:00

  • Noise History and Auditory Function in Young Adults With and Without Type 1 Diabetes Mellitus.

    abstract:OBJECTIVES:The purpose of this study was to examine the relationship between noise exposure history, type 1 diabetes mellitus (DM), and suprathreshold measures of auditory function. DESIGN:A cross-sectional study was conducted; 20 normal-hearing participants without type 1 DM were matched on age and sex to 20 normal-h...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000457

    authors: Spankovich C,Le Prell CG,Lobarinas E,Hood LJ

    更新日期:2017-11-01 00:00:00

  • Comparison of real-ear to coupler difference values in the right and left ear of adults using three earmold configurations.

    abstract:OBJECTIVE:The purpose of the study was to compare real-ear to coupler difference (RECD) values in the right and left ear of adults using three earmold configurations. DESIGN:The RECD was obtained from both ears of 18 normal hearing adults by subtracting the HA2 2-cc coupler response from the real-ear response using an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200506000-00005

    authors: Munro KJ,Buttfield LM

    更新日期:2005-06-01 00:00:00

  • Head Movements Allow Listeners Bilaterally Implanted With Cochlear Implants to Resolve Front-Back Confusions.

    abstract:OBJECTIVES:We report on the ability of patients fit with bilateral cochlear implants (CIs) to distinguish the front-back location of sound sources both with and without head movements. At issue was (i) whether CI patients are more prone to front-back confusions than normal hearing listeners for wideband, high-frequency...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000581

    authors: Pastore MT,Natale SJ,Yost WA,Dorman MF

    更新日期:2018-11-01 00:00:00

  • Use of the Connected Speech Test (CST) with hearing-impaired listeners.

    abstract::Two studies were performed in which hearing-impaired subjects responded to the Connected Speech Test (CST). In experiment 1, 40 subjects, divided into four groups according to extent and configuration of hearing loss, responded to the CST version 1 (CSTv1). This version of the test consisted of 57 passages of connecte...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198808000-00005

    authors: Cox RM,Alexander GC,Gilmore C,Pusakulich KM

    更新日期:1988-08-01 00:00:00

  • Audiologic manifestations of patients with post-treatment Lyme disease syndrome.

    abstract:OBJECTIVE:The purpose of this study was to characterize auditory function in patients diagnosed with post-treatment Lyme disease syndrome (PTLDS). DESIGN:Eighteen patients with PTLDS were evaluated and compared to a normal population. Evaluations consisted of pure tone and speech thresholds, word recognition (WRS), ac...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000100205.25774.5F

    authors: Shotland LI,Mastrioanni MA,Choo DL,Szymko-Bennett YM,Dally LG,Pikus AT,Sledjeski K,Marques A

    更新日期:2003-12-01 00:00:00

  • Different Associations between Auditory Function and Cognition Depending on Type of Auditory Function and Type of Cognition.

    abstract:OBJECTIVES:Previous studies strongly suggest that declines in auditory threshold can lead to impaired cognition. The aim of this study was to expand that picture by investigating how the relationships between age, auditory function, and cognitive function vary with the types of auditory and cognitive function considere...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000700

    authors: Danielsson H,Humes LE,Rönnberg J

    更新日期:2019-09-01 00:00:00

  • Use of test-retest measures to evaluate performance stability in adults with cochlear implants.

    abstract:OBJECTIVE:This study was designed to evaluate performance stability with test-retest measures of electrical thresholds, electrical maximum acceptable loudness levels, sound-field thresholds, and audition-only speech tests. The hypothesis was that the standard error of measurement differs from one individual to another ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199504000-00006

    authors: Skinner MW,Holden LK,Demorest ME,Holden TA

    更新日期:1995-04-01 00:00:00

  • Frequency-specific temporal envelope and periodicity components for lexical tone identification in Cantonese.

    abstract:OBJECTIVES:Temporal envelope and periodicity components (TEPC) in the speech signal have potentials to offer important cues for speech recognition especially in tonal languages. The aims of this study are: (i) to investigate the degree of contributions of TEPC to lexical tone identification in Cantonese; and (ii) to in...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31803153ac

    authors: Yuen KC,Yuan M,Lee T,Soli S,Tong MC,van Hasselt CA

    更新日期:2007-04-01 00:00:00

  • Bilateral and unilateral cochlear implant users compared on speech perception in noise.

    abstract:OBJECTIVE:Compare speech performance in noise with matched bilateral cochlear implant (CICI) and unilateral cochlear implant (CI only) users. DESIGN:Thirty CICI and 30 CI-only subjects were tested on a battery of speech perception tests in noise that use an eight-loudspeaker array. RESULTS:On average, CICI subject's ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181c12383

    authors: Dunn CC,Noble W,Tyler RS,Kordus M,Gantz BJ,Ji H

    更新日期:2010-04-01 00:00:00

  • Longitudinal Development of Distortion Product Otoacoustic Emissions in Infants With Normal Hearing.

    abstract:OBJECTIVES:The purpose of this study was to describe normal characteristics of distortion product otoacoustic emission (DPOAE) signal and noise level in a group of newborns and infants with normal hearing followed longitudinally from birth to 15 months of age. DESIGN:This is a prospective, longitudinal study of 231 in...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000542

    authors: Hunter LL,Blankenship CM,Keefe DH,Feeney MP,Brown DK,McCune A,Fitzpatrick DF,Lin L

    更新日期:2018-09-01 00:00:00

  • The Relation Between Child Versus Parent Report of Chronic Fatigue and Language/Literacy Skills in School-Age Children with Cochlear Implants.

    abstract:OBJECTIVES:Preliminary evidence suggests that children with hearing loss experience elevated levels of chronic fatigue compared with children with normal hearing. Chronic fatigue is associated with decreased academic performance in many clinical populations. Children with cochlear implants as a group exhibit deficits i...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000242

    authors: Werfel KL,Hendricks AE

    更新日期:2016-03-01 00:00:00

  • Measures of digit span and verbal rehearsal speed in deaf children after more than 10 years of cochlear implantation.

    abstract:OBJECTIVES:Conventional assessments of outcomes in deaf children with cochlear implants (CIs) have focused primarily on endpoint or product measures of speech and language. Little attention has been devoted to understanding the basic underlying core neurocognitive factors involved in the development and processing of s...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181ffd58e

    authors: Pisoni DB,Kronenberger WG,Roman AS,Geers AE

    更新日期:2011-02-01 00:00:00