A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in nucleus 24 cochlear implant users.

Abstract:

OBJECTIVE:The primary goal of this study was to examine changes that may occur in electrode impedance, electrically evoked compound action potential (EAP) threshold and slope of the EAP growth function, and behavioral measures of threshold T-level) and maximum comfort (C-level) over time in both adult and child cochlear implant users. Secondary goals were to determine whether changes in these measures are consistent between children and adults, and to determine whether behavioral measures (MAP T- and C-levels) and electrophysiologic measures (EAP thresholds) exhibit the same trends over time. DESIGN:Thirty-five children and 33 adults implanted with the Nucleus CI24M between November 1996 and August 1999 participated in this study. Subjects were included in this study if 1) they had used their implant for at least 1 yr after device connection, and 2) they had participated in the necessary data collection at a minimum number of the time intervals assessed in this study. EAP threshold, slope of the EAP growth function, and common ground electrode impedance measures were collected intraoperatively, at initial stimulation, and at several subsequent visits up to 2 yr post initial stimulation. MAP T- an d C-levels weremeasured at initial stimulation and at the same time intervals as described above. RESULTS:Changes in electrode impedance, EAP thresholds, and slope of the EAP growth function from measures made intraoperatively, at initial stimulation, and at 1 to 2 mo post initial stimulation were similar in both children and adults. Beyond the 1- to 2-mo visit, children exhibited significant increases in electrode impedance, EAP thresholds, slope, and MAP T-levels, whereas these samemeasures in adults remained relatively stable. EAP thresholds in children stabilized by the 3- to 8-mo visit, and electrode impedance stabilized by the 6- to 8-mo visit, while slope of the EAP growth function, MAP T-levels,and MAP C-levels werestable by 1 yr post initial stimulation. C-levels in adults increased up to 1 yr post initial stimulation; however, the amount of increase was much smaller than that seen in children. In both children and adults, longitudinal trends in EAP thresholds mirrored T-level more closely than C-level. CONCLUSIONS:The results of this study suggest that peripheral changes occur in many children that do not generally occur in adults within the first year of cochlear implant use. One implication of these results is that if EAP thresholds are to be used to assist in programming the speech processor for children, it is best to make those measures at the same time interval as device programming rather than using measures made intraoperatively or at the initial programming session to set MAP levels at later visits.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Hughes ML,Vander Werff KR,Brown CJ,Abbas PJ,Kelsay DM,Teagle HF,Lowder MW

doi

10.1097/00003446-200112000-00004

subject

Has Abstract

pub_date

2001-12-01 00:00:00

pages

471-86

issue

6

eissn

0196-0202

issn

1538-4667

journal_volume

22

pub_type

杂志文章
  • Cost-Effective Hearing Conservation: Regulatory and Research Priorities.

    abstract::Hearing conservation programs (HCPs) mandated by the US Occupational Safety and Health Administration (OSHA) cost about $350/worker/year. Are they cost-effective? A cross-sectional model of the US adult population with and without HCPs incorporates (1) the American Medical Association's method for estimating binaural ...

    journal_title:Ear and hearing

    pub_type: 社论

    doi:10.1097/AUD.0000000000000523

    authors: Dobie RA

    更新日期:2018-07-01 00:00:00

  • A Bayesian perspective on tinnitus pitch matching.

    abstract:OBJECTIVES:New tinnitus therapies are being developed and marketed that target the patient's tinnitus frequency. This frequency is estimated clinically by pitch matching, which has the patient identify the pure tone that is closest to the perceived tinnitus frequency. Though widely used, pitch matching is heavily criti...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000081

    authors: McMillan GP,Thielman EJ,Wypych K,Henry JA

    更新日期:2014-11-01 00:00:00

  • Factors Predicting Postoperative Unilateral and Bilateral Speech Recognition in Adult Cochlear Implant Recipients with Acoustic Hearing.

    abstract:OBJECTIVES:The first objective was to examine factors that could be predictive of postoperative unilateral (cochlear implant alone) speech recognition ability in a group of subjects with greater degrees of preoperative acoustic hearing than has been previously examined. Second, the study aimed to identify factors predi...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000233

    authors: Plant K,McDermott H,van Hoesel R,Dawson P,Cowan R

    更新日期:2016-03-01 00:00:00

  • Application of the kurtosis statistic to the evaluation of the risk of hearing loss in workers exposed to high-level complex noise.

    abstract:OBJECTIVE:Develop dose-response relations for two groups of industrial workers exposed to Gaussian or non-Gaussian (complex) types of continuous noises and to investigate what role, if any, the kurtosis statistic can play in the evaluation of industrial noise-induced hearing loss (NIHL). DESIGN:Audiometric and noise e...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181d94e68

    authors: Zhao YM,Qiu W,Zeng L,Chen SS,Cheng XR,Davis RI,Hamernik RP

    更新日期:2010-08-01 00:00:00

  • Identification of neonatal hearing impairment: auditory brain stem responses in the perinatal period.

    abstract:OBJECTIVES:1) To describe the auditory brain stem response (ABR) measurement system and optimized methods used for study of newborn hearing screening. 2) To determine how recording and infant factors related to the screening, using well-defined, specific ABR outcome measures. DESIGN:Seven thousand one hundred seventy-...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200010000-00006

    authors: Sininger YS,Cone-Wesson B,Folsom RC,Gorga MP,Vohr BR,Widen JE,Ekelid M,Norton SJ

    更新日期:2000-10-01 00:00:00

  • Distortion-product and click-evoked otoacoustic emissions of preterm and full-term infants.

    abstract::Full-term and preterm infants were evaluated with click-evoked and distortion-product otoacoustic emissions (CEOEs and DPOEs). The CEOEs and DPOEs recorded from each individual ear were analyzed by calculating the root-mean-square levels within half-octave bands. The fail criterion of the OE tests was that the half-oc...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199308000-00005

    authors: Smurzynski J,Jung MD,Lafreniere D,Kim DO,Kamath MV,Rowe JC,Holman MC,Leonard G

    更新日期:1993-08-01 00:00:00

  • Evaluation of Long-Term Cochlear Implant Use in Subjects With Acquired Unilateral Profound Hearing Loss: Focus on Binaural Auditory Outcomes.

    abstract:INTRODUCTION:Cochlear implantation (CI) in subjects with unilateral profound sensorineural hearing loss was investigated. The authors of the present study demonstrated the binaural auditory outcomes in a 12- and 36-month prospective cohort outcome study. The present study aimed to do a long-term (LT) evaluation of the ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000359

    authors: Mertens G,De Bodt M,Van de Heyning P

    更新日期:2017-01-01 00:00:00

  • Sound-direction identification with bilateral cochlear implants.

    abstract:OBJECTIVE:The purpose of this study was to compare the accuracy of sound-direction identification in the horizontal plane by bilateral cochlear implant users when localization was measured with pink noise and with speech stimuli. DESIGN:Eight adults who were bilateral users of Nucleus 24 Contour devices participated i...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000249910.80803.b9

    authors: Neuman AC,Haravon A,Sislian N,Waltzman SB

    更新日期:2007-02-01 00:00:00

  • Use of Direct-Connect for Remote Speech-Perception Testing in Cochlear Implants.

    abstract:OBJECTIVES:Previous research has demonstrated the feasibility of programming cochlear implants (CIs) via telepractice. To effectively use telepractice in a comprehensive manner, all components of a clinical CI visit should be validated using remote technology. Speech-perception testing is important for monitoring outco...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000693

    authors: Sevier JD,Choi S,Hughes ML

    更新日期:2019-09-01 00:00:00

  • Systematic Review on Late Cochlear Implantation in Early-Deafened Adults and Adolescents: Predictors of Performance.

    abstract:OBJECTIVES:Early-deafened, late-implanted adolescents and adults constitute a unique group of cochlear implant (CI) users, showing a large variability in outcomes. The current systematic review aimed to determine which preimplantation factors are relevant in predicting postoperative outcomes in this patient group. DES...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000889

    authors: Debruyne JA,Janssen AM,Brokx JPL

    更新日期:2020-11-01 00:00:00

  • The Cost of Ménière's Disease: A Novel Multisource Approach.

    abstract:OBJECTIVES:To estimate the annual cost of Ménière's disease and the cost per person in the UK population and to investigate the direct and indirect costs of the condition. DESIGN:The authors utilized a multidata approach to provide the first estimate of the cost of Ménière's. Data from the UK Biobank (a study of 500,0...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000264

    authors: Tyrrell J,Whinney DJ,Taylor T

    更新日期:2016-05-01 00:00:00

  • The efficiency of the single- versus multiple-stimulus auditory steady state responses in infants.

    abstract:OBJECTIVES:Multiple auditory steady state responses (ASSRs) will likely be included in the diagnostic test battery for estimating infant auditory thresholds in the near future; however, the effects of single- versus multiple-stimulus presentation in infants has never been investigated. In adults, there are no interacti...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e3181ff352c

    authors: Hatton J,Stapells DR

    更新日期:2011-05-01 00:00:00

  • Interleaved Processors Improve Cochlear Implant Patients' Spectral Resolution.

    abstract:OBJECTIVE:Cochlear implant patients have difficulty in noisy environments, in part, because of channel interaction. Interleaving the signal by sending every other channel to the opposite ear has the potential to reduce channel interaction by increasing the space between channels in each ear. Interleaving still potentia...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000249

    authors: Aronoff JM,Stelmach J,Padilla M,Landsberger DM

    更新日期:2016-03-01 00:00:00

  • Factors affecting sensitivity of distortion-product otoacoustic emissions to ototoxic hearing loss.

    abstract:OBJECTIVES:(1) To determine the ototoxicity detection rate (sensitivity) for distortion-product otoacoustic emissions (DPOAEs) testing in adults who received ototoxic medications and experienced pure-tone threshold changes during the course of treatment; (2) to determine the extent to which DPOAE sensitivity to ototoxi...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e318181ad99

    authors: Reavis KM,Phillips DS,Fausti SA,Gordon JS,Helt WJ,Wilmington D,Bratt GW,Konrad-Martin D

    更新日期:2008-12-01 00:00:00

  • The Emotional Communication in Hearing Questionnaire (EMO-CHeQ): Development and Evaluation.

    abstract:OBJECTIVES:The objectives of this research were to develop and evaluate a self-report questionnaire (the Emotional Communication in Hearing Questionnaire or EMO-CHeQ) designed to assess experiences of hearing and handicap when listening to signals that contain vocal emotion information. DESIGN:Study 1 involved interne...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000611

    authors: Singh G,Liskovoi L,Launer S,Russo F

    更新日期:2019-03-01 00:00:00

  • Qualities of Single Electrode Stimulation as a Function of Rate and Place of Stimulation with a Cochlear Implant.

    abstract:OBJECTIVES:Although it has been shown previously that changes in temporal coding produce changes in pitch in all cochlear regions, research has suggested that temporal coding might be best encoded in relatively apical locations. The authors hypothesized that although temporal coding may provide useable information at a...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000250

    authors: Landsberger DM,Vermeire K,Claes A,Van Rompaey V,Van de Heyning P

    更新日期:2016-05-01 00:00:00

  • Auditory steady state cortical responses indicate deviant phonemic-rate processing in adults with dyslexia.

    abstract:OBJECTIVES:Speech intelligibility is strongly influenced by the ability to process temporal modulations. It is hypothesized that in dyslexia, deficient processing of rapidly changing auditory information underlies a deficient development of phonological representations, causing reading and spelling problems. Low-freque...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31822c26b9

    authors: Poelmans H,Luts H,Vandermosten M,Boets B,Ghesquière P,Wouters J

    更新日期:2012-01-01 00:00:00

  • Listening Effort: How the Cognitive Consequences of Acoustic Challenge Are Reflected in Brain and Behavior.

    abstract::Everyday conversation frequently includes challenges to the clarity of the acoustic speech signal, including hearing impairment, background noise, and foreign accents. Although an obvious problem is the increased risk of making word identification errors, extracting meaning from a degraded acoustic signal is also cogn...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0000000000000494

    authors: Peelle JE

    更新日期:2018-03-01 00:00:00

  • Top-Down Processes in Simulated Electric-Acoustic Hearing: The Effect of Linguistic Context on Bimodal Benefit for Temporally Interrupted Speech.

    abstract:OBJECTIVES:Previous studies have documented the benefits of bimodal hearing as compared with a cochlear implant alone, but most have focused on the importance of bottom-up, low-frequency cues. The purpose of the present study was to evaluate the role of top-down processing in bimodal hearing by measuring the effect of ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000298

    authors: Oh SH,Donaldson GS,Kong YY

    更新日期:2016-09-01 00:00:00

  • Conversational Interaction Is the Brain in Action: Implications for the Evaluation of Hearing and Hearing Interventions.

    abstract::Humans have evolved the unique capacity to efficiently communicate using the spoken word. Hearing plays a key role as a receiver in this process and dysfunction leads to difficulties in listening and communication. It is widely accepted that effective communication is not adequately captured with current behavioral sp...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000939

    authors: Carlile S,Keidser G

    更新日期:2020-11-01 00:00:00

  • Longitudinal changes in word recognition by patients who use the Ineraid cochlear implant.

    abstract::The time course for reacquisition of spondee word recognition was examined for 27 patients who use the Ineraid cochlear implant. At 1 month postfitting, test scores ranged from 0 to 84% correct. The median score was 10% correct. At 22 to 28 months postfitting, the scores ranged from 0 to 100% correct. The median score...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199012000-00008

    authors: Dorman MF,Dankowski K,McCandless G,Parkin JL,Smith L

    更新日期:1990-12-01 00:00:00

  • Parents' preferences for services for children with hearing loss: a conjoint analysis study.

    abstract:OBJECTIVE:Early identification of permanent childhood hearing loss through universal newborn hearing screening is rapidly becoming a standard of care. However, it is well recognized that hearing screening must be embedded within a comprehensive system of rehabilitation and parent support services. This study was undert...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e318157676d

    authors: Fitzpatrick E,Coyle DE,Durieux-Smith A,Graham ID,Angus DE,Gaboury I

    更新日期:2007-12-01 00:00:00

  • Design and function: a physical and electrical description of the 3M House cochlear implant system.

    abstract::A patient-wearable, single-electrode cochlear implant was first used by a patient in 1972 at the House Ear Institute. Since early 1982, a redesigned version of this system has been in clinical use. This new system, called the 3M House cochlear implant system, consists of an implanted receiver and a patient-worn signal...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:

    authors: Fretz RJ,Fravel RP

    更新日期:1985-05-01 00:00:00

  • Pitfalls in neurotologic diagnosis.

    abstract::Several cases illustrating potential pitfalls in neurotologic diagnosis from the viewpoint of the otologist are presented. The role of auditory brain stem response testing is specifically emphasized in cases with discordant audiologic and radiographic findings. Included are one case of a "false negative" ABR in a pati...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198804000-00007

    authors: Telian SA,Kileny PR

    更新日期:1988-04-01 00:00:00

  • Use of probe tube microphone measurements in hearing aid selection for children: some initial clinical experiences.

    abstract::Some initial experiences are described in which ear canal probe tube microphone measurements are used to determine hearing aid settings for children. Decisions are based upon ideas developed by Seewald and Ross (in Amplification for the Hearing Impaired, New York: Grune & Stratton, 1988: 213-267) and Seewald, Ross, an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198910000-00002

    authors: Hawkins DB,Morrison TM,Halligan PL,Cooper WA

    更新日期:1989-10-01 00:00:00

  • Middle ear application of a sodium hyaluronate gel loaded with neomycin in a Guinea pig model.

    abstract:OBJECTIVE:Establishing methods for topical administration of drugs to the inner ear have great clinical relevance and potential even in a relatively short perspective. To evaluate the efficacy of sodium hyaluronate (HYA) as a vehicle for drugs that could be used for treatment of inner ear disorders. METHODS:The cochle...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31818ff98e

    authors: Saber A,Laurell G,Bramer T,Edsman K,Engmér C,Ulfendahl M

    更新日期:2009-02-01 00:00:00

  • Highly variable population-based prevalence rates of unilateral hearing loss after the application of common case definitions.

    abstract:OBJECTIVES:This study shows how population-based estimates of the prevalence of unilateral hearing loss (UHL) in children aged 6 to 19 yrs can differ considerably with various applications of commonly accepted case definitions. It also examines demographic variables and risk factors related to UHL. DESIGN:The Third Na...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181bb69db

    authors: Ross DS,Visser SN,Holstrum WJ,Qin T,Kenneson A

    更新日期:2010-02-01 00:00:00

  • Mechanisms of Localization and Speech Perception with Colocated and Spatially Separated Noise and Speech Maskers Under Single-Sided Deafness with a Cochlear Implant.

    abstract:OBJECTIVES:This study tested listeners with a cochlear implant (CI) in one ear and acoustic hearing in the other ear, to assess their ability to localize sound and to understand speech in collocated or spatially separated noise or speech maskers. DESIGN:Eight CI listeners with contralateral acoustic hearing ranging fr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000708

    authors: Dirks C,Nelson PB,Sladen DP,Oxenham AJ

    更新日期:2019-11-01 00:00:00

  • Initial independent results with the Clarion cochlear implant.

    abstract:OBJECTIVE:This paper reports some preliminary findings from patients, implanted at the University of Iowa, using the Advanced Bionics Clarion cochlear implant (version 1.0). We compared the performance of patients using both simultaneous analog and nonsimultaneous pulsatile processing strategies. The performance of Cla...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199612000-00008

    authors: Tyler RS,Gantz BJ,Woodworth GG,Parkinson AJ,Lowder MW,Schum LK

    更新日期:1996-12-01 00:00:00

  • Effect of peak clipping on speech recognition threshold.

    abstract::Speech recognition thresholds (SRTs) were measured for a closed set of spondees that had been processed by peak clipping and compression. Both hearing-impaired and normal-hearing subject groups showed progressively higher SRTs with increasing levels of peak clipping, with significant threshold shifts occurring for cli...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199412000-00005

    authors: Crain TR,Van Tasell DJ

    更新日期:1994-12-01 00:00:00