Abstract:
:Ipsilaterally and contralaterally recorded auditory brain stem responses to 80 dB nHL clicks were recorded from 37 infants, aged 2 weeks to 20 mo and from six adults, all with normal auditory function. With increasing age, contralateral waves A, B, C, and D and ipsilateral waves III and V decreased in latency, with the contralateral morphology more closely resembling the ipsilateral morphology as age increased, especially after the age of 9 mo. The mean latencies and their change with age for waves A and B resembled those of ipsilateral waves III and III', respectively; both waves C and D demonstrated similarities with wave V. Large waveform changes were seen with maturation in the latency region of contralateral waves C and D. In 42 of 43 subjects, wave V latency occurred after wave C and before wave D. Peak to peak amplitudes of contralateral waves A-B and D-E' increased with age, but were smaller than those of ipsilateral I'-III and V-V', respectively. The smaller contralateral responses make their use for threshold estimation problematic, especially before the age of 9 months. The contralateral response, however, may help to select wave V in ambiguous cases, and to determine response laterality.
journal_name
Ear Hearjournal_title
Ear and hearingauthors
Stapells DR,Mosseri Mdoi
10.1097/00003446-199106000-00002subject
Has Abstractpub_date
1991-06-01 00:00:00pages
167-73issue
3eissn
0196-0202issn
1538-4667journal_volume
12pub_type
杂志文章相关文献
EAR AND HEARING文献大全abstract:OBJECTIVES:Little is known about the maturational changes in the mechanical properties of the skull and how they might contribute to infant-adult differences in bone conduction hearing sensitivity. The objective of this study was to investigate the mechanical impedance of the skin-covered skull for different skull posi...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000272
更新日期:2016-07-01 00:00:00
abstract::A patient-wearable, single-electrode cochlear implant was first used by a patient in 1972 at the House Ear Institute. Since early 1982, a redesigned version of this system has been in clinical use. This new system, called the 3M House cochlear implant system, consists of an implanted receiver and a patient-worn signal...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:
更新日期:1985-05-01 00:00:00
abstract:OBJECTIVE:The purposes of this study were to (a) examine the accuracy of cochlear implant recipients who use different types of devices and signal processing strategies on pitch ranking as a function of size of interval and frequency range and (b) to examine the relations between this pitch perception measure and demog...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e3180479318
更新日期:2007-06-01 00:00:00
abstract:OBJECTIVES:Loudness-balance measurements with monaurally impaired subjects have shown that the shape of the loudness versus sound-pressure curve among hearing-impaired persons varies significantly. But the effectiveness of adjusting the compression characteristics of wide-dynamic-range compression hearing aids-the comp...
journal_title:Ear and hearing
pub_type: 临床试验,杂志文章
doi:10.1097/AUD.0b013e318177d9c6
更新日期:2008-10-01 00:00:00
abstract::This article reviews research on the relatively recently discovered event-related potential component, the mismatch negativity (MMN), which is of great potential interest for understanding central auditory function and various forms of its pathology. This change-specific response can serve as an accurate objective mea...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:
更新日期:1995-02-01 00:00:00
abstract:OBJECTIVES:New tinnitus therapies are being developed and marketed that target the patient's tinnitus frequency. This frequency is estimated clinically by pitch matching, which has the patient identify the pure tone that is closest to the perceived tinnitus frequency. Though widely used, pitch matching is heavily criti...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000081
更新日期:2014-11-01 00:00:00
abstract:OBJECTIVES:The aim of the study was to investigate the link between temporal fine structure (TFS) processing, pitch, and speech perception performance in adult cochlear implant (CI) recipients, including bimodal listeners who may benefit better low-frequency (LF) temporal coding in the contralateral ear. DESIGN:The st...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000525
更新日期:2018-07-01 00:00:00
abstract::A case is presented of a patient with lateral pontine stroke which resulted in a moderate unilateral sensorineural hearing loss. ABR, word recognition scores, acoustic reflexes, neurological evaluation, and CT scan were consistent with brain stem lesion. Recovery of hearing, including acoustic reflexes and word recogn...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:
更新日期:1989-04-01 00:00:00
abstract::In 430 individuals with adult onset hearing loss, relationships were explored between definitions of handicap based on a number of arithmetic formulas applied to audiometric data and definitions of handicap based on two self-report questionnaires (the Denver Scale of Communication Function and the Social Hearing Handi...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198503000-00005
更新日期:1985-03-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the pr...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000562
更新日期:2018-11-01 00:00:00
abstract::This paper will provide a backdrop to the others in this section on outcomes of children with mild to moderate sensorineural hearing loss. Our objective here is to provide an overview of the research approaches used to study the outcomes of these children to provide guidance for future studies of children with mild to...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/AUD.0b013e318157f093
更新日期:2007-12-01 00:00:00
abstract::This paper includes an overview of the research on late-onset auditory deprivation, an evaluation of the evidence from retrospective and prospective studies, recommendations for future research, and a consideration of the theoretical and clinical implications of the research. The studies reviewed offer convincing evid...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199617031-00002
更新日期:1996-06-01 00:00:00
abstract:OBJECTIVES:Here, we evaluate the risks of amplified music for disc-jockeys (DJs) working in nightclubs. DESIGN:Sound level measurements were performed within the DJ mixing booths. A questionnaire was used to obtain exposure to noise and length of time in the profession. Audiograms and tinnitus pitch matching was also ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31819769fc
更新日期:2009-04-01 00:00:00
abstract::To provide insight into the behavioral characteristics of people who listen excessively to loud music, the 32-item Northeastern Excessive Music Listening Survey was developed and administered to 90 subjects. Results indicate that 8 of the 90 subjects scored within a range that would suggest the presence of a maladapti...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199812000-00003
更新日期:1998-12-01 00:00:00
abstract:OBJECTIVES:To determine whether (1) the auditory N1 component can be elicited to gaps in continuous narrowband noises, (2) psychophysical and electrophysiological gap thresholds (PGTs and EGTs) are similar to one another, and (3) EGTs are the same for all narrowband noise center frequencies. DESIGN:PGTs and EGTs were ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e3181b1354f
更新日期:2009-12-01 00:00:00
abstract:OBJECTIVE:Develop dose-response relations for two groups of industrial workers exposed to Gaussian or non-Gaussian (complex) types of continuous noises and to investigate what role, if any, the kurtosis statistic can play in the evaluation of industrial noise-induced hearing loss (NIHL). DESIGN:Audiometric and noise e...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e3181d94e68
更新日期:2010-08-01 00:00:00
abstract:OBJECTIVES:Previous research has demonstrated the feasibility of programming cochlear implants (CIs) via telepractice. To effectively use telepractice in a comprehensive manner, all components of a clinical CI visit should be validated using remote technology. Speech-perception testing is important for monitoring outco...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000693
更新日期:2019-09-01 00:00:00
abstract::The relationship between two dichotic listening tasks was studied. The two dichotic tests used were the Staggered Spondaic Word (SSW) test and the directed Dichotic Consonant-Vowel (CV) test. These measures were administered to 104 children between the ages of 6.0 and 8.0 yrs. The subjects were divided into two groups...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198311000-00003
更新日期:1983-11-01 00:00:00
abstract::This paper provides an overview of changes in the perception of sound that result from cochlear damage. It starts with a brief introduction to the physiology of the cochlea, emphasizing the role of the "active mechanism" and describing how cochlear function is altered by cochlear damage. Then the effects of cochlear d...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/00003446-199604000-00007
更新日期:1996-04-01 00:00:00
abstract:OBJECTIVES:In bilateral cochlear implant users, electrodes mapped to the same frequency range in each ear may stimulate different places in each cochlea due to an insertion depth difference of electrode arrays. This interaural place of stimulation mismatch can lead to problems with auditory image fusion and sensitivity...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000135
更新日期:2015-05-01 00:00:00
abstract:OBJECTIVES:Although directional microphones on a hearing aid provide a signal-to-noise ratio benefit in a noisy background, the amount of benefit is dependent on how close the signal of interest is to the front of the user. It is assumed that when the signal of interest is off-axis, users can reorient themselves to the...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000053
更新日期:2014-09-01 00:00:00
abstract:OBJECTIVE:To evaluate the effect of artifacts on the impulse and response recordings with the video head impulse test (VHIT) and determine how many stimuli are necessary for obtaining acceptably efficient measurements. METHODS:One hundred fifty patients were examined using VHIT and their registries searched for artifa...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000849
更新日期:2020-09-01 00:00:00
abstract::The development of hand-held auditory screening devices has led to increased hearing screening by physicians. Ambient noise levels were assessed in examination rooms of 20 physician offices. Measurements provided Ln, Leq, Lmax, and octave band data for specialty types: pediatrics, internal medicine, family practice an...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199010000-00012
更新日期:1990-10-01 00:00:00
abstract:OBJECTIVES:To measure benefit in terms of speech recognition in quiet and in noise, and conservation of residual hearing in three groups of subjects implanted with the Nucleus Straight Research Array cochlear implant. This device incorporates the Nucleus Slim Straight electrode carrier designed to be easier to insert i...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.aud.0000444781.15858.f1
更新日期:2014-03-01 00:00:00
abstract:OBJECTIVES:Interference between a target and simultaneous maskers occurs both at the cochlear level through energetic masking and more centrally through informational masking (IM). Hence, quantifying the amount of IM requires a strict control of the energetic component. Presenting target and maskers on different sides ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000116
更新日期:2015-05-01 00:00:00
abstract:OBJECTIVE:To compare the performance of cochlear implant patients and normal-hearing subjects on a musical interval labeling task, and to determine whether information regarding musical interval size is available to cochlear implant patients under realistic everyday listening conditions. DESIGN:Two Nucleus cochlear im...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199710000-00002
更新日期:1997-10-01 00:00:00
abstract:OBJECTIVE:To evaluate the ability of clinical test signals to match the aided levels of real speech, across a range of hearing aid circuit types and strengths. DESIGN:Hearing aids (N = 41) were set to DSL targets for moderate, severe, and profound hearing losses. These hearing aids were tested with three test signals ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200210000-00009
更新日期:2002-10-01 00:00:00
abstract:OBJECTIVE:It is widely recognized by hearing aid users and audiologists that a period of auditory acclimatization and adjustment is needed for new users to become accustomed to their devices. The aim of the present study was to test the idea that auditory acclimatization and adjustment to hearing aids involves a proces...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000366
更新日期:2017-03-01 00:00:00
abstract:OBJECTIVES:Preliminary evidence suggests that children with hearing loss experience elevated levels of chronic fatigue compared with children with normal hearing. Chronic fatigue is associated with decreased academic performance in many clinical populations. Children with cochlear implants as a group exhibit deficits i...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000242
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVES:The level-dependent growth of distortion product otoacoustic emissions (DPOAEs) provides an indirect metric of cochlear compressive nonlinearity. Recent evidence suggests that aging reduces nonlinear distortion emissions more than those associated with linear reflection. Therefore, in this study, we generate...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000319
更新日期:2016-09-01 00:00:00