Acoustic reflex thresholds: variability and distribution effects.

Abstract:

:Acoustic reflex thresholds (ARTs) at 500, 1000, and 2000 Hz from 1833 ears were subjected to multiple linear regression analyses using a stepwise inclusion model to determine the effects of hearing losses in the 500- to 4000-Hz range for each of the activators. Although statistically significant regression equations were developed, these accounted for only 1 to 47% of the variance of ART levels. In light of the wide variance of ARTs unexplainable directly from audiometric data, it was deemed more appropriate to consider the range of ARTs from the standpoint of the sampling distribution of ARTs as a function of hearing level. Deciles were calculated in the 10th through 90th percentile ranges. These data corroborate and expand upon previously reported material on the distributions of ARTs among ears with normal hearing and cochlear impairment.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Gelfand SA,Piper N

doi

10.1097/00003446-198407000-00007

subject

Has Abstract

pub_date

1984-07-01 00:00:00

pages

228-34

issue

4

eissn

0196-0202

issn

1538-4667

journal_volume

5

pub_type

杂志文章
  • Repeatability of high-frequency bone conduction thresholds.

    abstract::The purpose of this study was to determine the repeatability of high-frequency, bone conduction thresholds and to increase the data base concerning high-frequency, bone conduction threshold levels. Bone conduction thresholds were obtained on 30 subjects having normal, low, and mid frequency (0.25 to 8 kHz) hearing thr...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/00003446-198712000-00010

    authors: Frank T,Ragland AE

    更新日期:1987-12-01 00:00:00

  • Reinforced active middle ear implant fixation in incus vibroplasty.

    abstract:OBJECTIVES:The active middle ear implant Vibrant Soundbridge® was originally designed to treat mild-to-severe sensorineural hearing losses. The floating mass transducer (FMT) is crimped onto the long incus process. The procedure is termed incus vibroplasty to distinguish from other attachment sites or stimulus modi for...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000078

    authors: Mlynski R,Dalhoff E,Heyd A,Wildenstein D,Hagen R,Gummer AW,Schraven SP

    更新日期:2015-01-01 00:00:00

  • Auditory steady state cortical responses indicate deviant phonemic-rate processing in adults with dyslexia.

    abstract:OBJECTIVES:Speech intelligibility is strongly influenced by the ability to process temporal modulations. It is hypothesized that in dyslexia, deficient processing of rapidly changing auditory information underlies a deficient development of phonological representations, causing reading and spelling problems. Low-freque...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31822c26b9

    authors: Poelmans H,Luts H,Vandermosten M,Boets B,Ghesquière P,Wouters J

    更新日期:2012-01-01 00:00:00

  • A new concept for Cochlear implant speech processing.

    abstract:OBJECTIVE:A new speech processing concept and its implementation cochlear implant neural net, simulation and stimulation (CINSTIM), for cochlear implant systems is currently under investigation. The main objectives of this new strategy are to improve speech perception within the early rehabilitation period for prelingu...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199602000-00009

    authors: Leisenberg M,Dees DC

    更新日期:1996-02-01 00:00:00

  • Pinna-Imitating Microphone Directionality Improves Sound Localization and Discrimination in Bilateral Cochlear Implant Users.

    abstract:OBJECTIVES:To compare the sound-source localization, discrimination, and tracking performance of bilateral cochlear implant users with omnidirectional (OMNI) and pinna-imitating (PI) microphone directionality modes. DESIGN:Twelve experienced bilateral cochlear implant users participated in the study. Their audio proce...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000912

    authors: Fischer T,Schmid C,Kompis M,Mantokoudis G,Caversaccio M,Wimmer W

    更新日期:2020-07-16 00:00:00

  • Hearing handicap ratings among different profiles of adult cochlear implant users.

    abstract:OBJECTIVE:The aim was to compare outcomes in the domain of self-reported hearing handicap across groups of patients fit with one versus two cochlear implants (CI, CI + CI), or with an implant and a hearing aid (HA) in the nonimplanted ear (CI + HA). DESIGN:The design was retrospective, and a preliminary step was to fa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31815d6da8

    authors: Noble W,Tyler R,Dunn C,Bhullar N

    更新日期:2008-01-01 00:00:00

  • Middle ear application of a sodium hyaluronate gel loaded with neomycin in a Guinea pig model.

    abstract:OBJECTIVE:Establishing methods for topical administration of drugs to the inner ear have great clinical relevance and potential even in a relatively short perspective. To evaluate the efficacy of sodium hyaluronate (HYA) as a vehicle for drugs that could be used for treatment of inner ear disorders. METHODS:The cochle...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31818ff98e

    authors: Saber A,Laurell G,Bramer T,Edsman K,Engmér C,Ulfendahl M

    更新日期:2009-02-01 00:00:00

  • Melodic contour identification by cochlear implant listeners.

    abstract:OBJECTIVE:While the cochlear implant provides many deaf patients with good speech understanding in quiet, music perception and appreciation with the cochlear implant remains a major challenge for most cochlear implant users. The present study investigated whether a closed-set melodic contour identification (MCI) task c...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000261689.35445.20

    authors: Galvin JJ 3rd,Fu QJ,Nogaki G

    更新日期:2007-06-01 00:00:00

  • A systematic review of the nonacoustic benefits of bone-anchored hearing AIDS.

    abstract:OBJECTIVE:This study completed an evidence-based practice systematic review of the nonacoustic benefits for adult patients receiving bone-anchored hearing aid(s) (BAHAs) relative to other forms of amplification (i.e., none, bone-conduction hearing aids [BCHAs], or air-conduction hearing aids [ACHAs]). DESIGN:Systemati...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/01.aud.0000240635.70277.3f

    authors: Johnson CE,Danhauer JL,Reith AC,Latiolais LN

    更新日期:2006-12-01 00:00:00

  • Human Frequency Following Responses to Vocoded Speech: Amplitude Modulation Versus Amplitude Plus Frequency Modulation.

    abstract:OBJECTIVES:The most commonly employed speech processing strategies in cochlear implants (CIs) only extract and encode amplitude modulation (AM) in a limited number of frequency channels. proposed a novel speech processing strategy that encodes both frequency modulation (FM) and AM to improve CI performance. Using behav...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000756

    authors: Suresh CH,Krishnan A,Luo X

    更新日期:2020-03-01 00:00:00

  • Isolating informational masking in both pure and complex tone sequences.

    abstract:OBJECTIVES:Interference between a target and simultaneous maskers occurs both at the cochlear level through energetic masking and more centrally through informational masking (IM). Hence, quantifying the amount of IM requires a strict control of the energetic component. Presenting target and maskers on different sides ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000116

    authors: Calcus A,Agus T,Kolinsky R,Colin C,Deltenre P

    更新日期:2015-05-01 00:00:00

  • Acoustic radiation produced by B-71, B-72, and KH 70 bone vibrators.

    abstract::The amount of acoustic radiation produced by two samples of a Radioear B-71, B-72, and Pracitronic KH 70 bone vibrator was determined for 30 normal-hearing subjects at 4000 Hz. The mean amount of acoustic radiation was very similar for both samples of each vibrator type but significantly (p less than 0.05) different b...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198610000-00010

    authors: Frank T,Crandell CC

    更新日期:1986-10-01 00:00:00

  • Strategies for infant auditory brain stem response assessment.

    abstract::The use of auditory brain stem response (ABR) represents a new dimension in auditory and neurological pediatric assessment. Because the ABR may be altered by stimulus and procedural variables, the lack of an established standard has reduced its clinical efficiency. This paper describes a suggested ABR protocol for inf...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198209000-00006

    authors: Jacobson JT,Morehouse CR,Johnson MJ

    更新日期:1982-09-01 00:00:00

  • The effect of gabapentin on gap detection and forward masking in young and old gerbils.

    abstract:OBJECTIVES:Auditory temporal processing frequently appears more affected in old subjects than would be predicted by the degree of peripheral hearing loss, pointing to an age-dependent central processing deficit. In parallel, an age-dependent decline of inhibitory function has been demonstrated in the auditory pathway, ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e318222289f

    authors: Gleich O,Strutz J

    更新日期:2011-11-01 00:00:00

  • Peripheral Auditory Involvement in Childhood Listening Difficulty.

    abstract:OBJECTIVES:This study tested the hypothesis that undetected peripheral hearing impairment occurs in children with idiopathic listening difficulties (LiDs), as reported by caregivers using the Evaluation of Children"s Listening and Processing Skills (ECLiPS) validated questionnaire, compared with children with typically...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000899

    authors: Hunter LL,Blankenship CM,Lin L,Sloat NT,Perdew A,Stewart H,Moore DR

    更新日期:2020-06-25 00:00:00

  • Evaluation of streamlined programming procedures for the Nucleus cochlear implant with the Contour electrode array.

    abstract:OBJECTIVE:The objective of this study was to evaluate streamlined programming procedures for the Nucleus cochlear implant system with the Contour electrode array. DESIGN:Phase 1 involved an examination of the clinical MAPs for the first 103 recipients implanted with the Contour electrode array in the Melbourne Cochlea...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000188201.86799.01

    authors: Plant K,Law MA,Whitford L,Knight M,Tari S,Leigh J,Pedley K,Nel E

    更新日期:2005-12-01 00:00:00

  • Objective calibration of bone conductors using otoacoustic emissions.

    abstract:OBJECTIVE:To demonstrate a technique for objectively calibrating bone conductors on an individual basis using distortion product otoacoustic emissions (DPOAEs). DESIGN:Individual calibrations were obtained using DPOAEs recorded from a single ear of 21 normally hearing adults. Validity and robustness of the technique w...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199910000-00001

    authors: Purcell D,Kunov H,Cleghorn W

    更新日期:1999-10-01 00:00:00

  • Effects of Phantom Electrode Stimulation on Vocal Production in Cochlear Implant Users.

    abstract:OBJECTIVES:Cochlear implant (CI) users suffer from a range of speech impairments, such as stuttering and vocal control of pitch and intensity. Though little research has focused on the role of auditory feedback in the speech of CI users, these speech impairments could be due in part to limited access to low-frequency c...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000690

    authors: Caldwell MT,Jiradejvong P,Limb CJ

    更新日期:2019-09-01 00:00:00

  • Cost-Effective Hearing Conservation: Regulatory and Research Priorities.

    abstract::Hearing conservation programs (HCPs) mandated by the US Occupational Safety and Health Administration (OSHA) cost about $350/worker/year. Are they cost-effective? A cross-sectional model of the US adult population with and without HCPs incorporates (1) the American Medical Association's method for estimating binaural ...

    journal_title:Ear and hearing

    pub_type: 社论

    doi:10.1097/AUD.0000000000000523

    authors: Dobie RA

    更新日期:2018-07-01 00:00:00

  • Evoked potentials: computer-automated threshold-tracking procedure using an objective detection criterion.

    abstract::A computer-automated, threshold-tracking procedure was developed for measuring evoked response thresholds on-line. The procedure utilizes an objective detection criterion (correlation) to evaluate whether a response is absent or present. Sound intensity is adjusted according to a modified PEST (parameter estimation by...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:

    authors: Salvi RJ,Ahroon W,Saunders SS,Arnold SA

    更新日期:1987-06-01 00:00:00

  • Jervell and Lange-Nielsen syndrome in Norwegian children: aspects around cochlear implantation, hearing, and balance.

    abstract:OBJECTIVES:Jervell and Lange-Nielsen syndrome (JLNS) is a rare cause of autosomal recessive inherited deafness. JLNS patients are candidates for cochlear implantation, and represent a group that needs special attention and precautions. The aim of this article is to draw some guidelines for dealing with these patients, ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/aud.0b013e3181645393

    authors: Siem G,Früh A,Leren TP,Heimdal K,Teig E,Harris S

    更新日期:2008-04-01 00:00:00

  • Event-related potentials in pediatric cochlear implant patients.

    abstract:OBJECTIVE:The main objective of this study was to assess the correlation of auditory event related potential (ERP) measures with behavioral assessment data to identify if ERPs including mismatch negativity (MMN) can be used to categorize cochlear implant patients into good and poor performers. DESIGN:We investigated a...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200412000-00008

    authors: Singh S,Liasis A,Rajput K,Towell A,Luxon L

    更新日期:2004-12-01 00:00:00

  • Judgments of hearing aid processed music.

    abstract::Paired comparison perception and preference judgments of hearing aid processed music were examined under conditions of extended and reduced high and low-frequency ranges. The performance of 20 subjects with mild to moderate hearing impairment was compared with an equal number of normal hearing controls. Subjects with ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198201000-00004

    authors: Franks JR

    更新日期:1982-01-01 00:00:00

  • Evaluation of a tinnitus masking program: a follow-up study of 598 patients.

    abstract::A follow-up study of two groups of tinnitus patients was conducted in an attempt to evaluate the tinnitus masking program. Results are discussed separately for a group of patients seen during the first three years of the program (1976 through 1978) and during the last year (1979). These results suggest an improvement ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198003000-00004

    authors: Schleuning AJ,Johnson RM,Vernon JA

    更新日期:1980-03-01 00:00:00

  • Effects of presentation level on phoneme and sentence recognition in quiet by cochlear implant listeners.

    abstract:OBJECTIVE:The objectives of this study were to characterize the effects of presentation level on speech recognition in quiet by cochlear implant users with the Nucleus 22 SPEAK and Clarion v1.2 CIS speech-processing strategies, and to relate speech recognition at low presentation levels to stimulus audibility as measur...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000090340.09847.39

    authors: Donaldson GS,Allen SL

    更新日期:2003-10-01 00:00:00

  • List equivalency of the CID everyday sentences (Harris revision) under three signal-to-noise ratios.

    abstract::The primary purpose of this study was to determine list equivalency of Harris' revision of the CID Everyday Sentence Lists under three signal-to-noise ratios: O dB, --3 dB, and --6 dB. On the basis of list means, nonsignificant groupings of lists were found at each noise level; however, lists were not equivalent at an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198309000-00006

    authors: Rippy JV,Dancer JE,Pittenger JB

    更新日期:1983-09-01 00:00:00

  • Psychophysical performance and Mandarin tone recognition in noise by cochlear implant users.

    abstract:OBJECTIVE:The present study was aimed to examine the relationship between psychophysical performance in temporal and spectral resolution and Mandarin tone recognition in noise by cochlear-implant (CI) listeners. DESIGN:Seventeen Nucleus-24 implant users, 10 postlingually deafened and 7 prelingually deafened, participa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e318031512c

    authors: Wei C,Cao K,Jin X,Chen X,Zeng FG

    更新日期:2007-04-01 00:00:00

  • Perceptual benefit and functional outcomes for children using sequential bilateral cochlear implants.

    abstract:OBJECTIVE:To evaluate the additional perceptual benefit provided to children through the use of two cochlear implants in comparison to one after 6 to 13 mo experience with sequential bilateral implants. DESIGN:A second cochlear implant was received by 11 children. The principal selection criteria were being age 4 to 1...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31806dc194

    authors: Galvin KL,Mok M,Dowell RC

    更新日期:2007-08-01 00:00:00

  • Noise History and Auditory Function in Young Adults With and Without Type 1 Diabetes Mellitus.

    abstract:OBJECTIVES:The purpose of this study was to examine the relationship between noise exposure history, type 1 diabetes mellitus (DM), and suprathreshold measures of auditory function. DESIGN:A cross-sectional study was conducted; 20 normal-hearing participants without type 1 DM were matched on age and sex to 20 normal-h...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000457

    authors: Spankovich C,Le Prell CG,Lobarinas E,Hood LJ

    更新日期:2017-11-01 00:00:00

  • The Benefits of Increased Sensation Level and Bandwidth for Spatial Release From Masking.

    abstract:OBJECTIVE:Spatial release from masking (SRM) can increase speech intelligibility in complex listening environments. The goal of the present study was to document how speech-in-speech stimuli could be best processed to encourage optimum SRM for listeners who represent a range of ages and amounts of hearing loss. We exam...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000352

    authors: Jakien KM,Kampel SD,Gordon SY,Gallun FJ

    更新日期:2017-01-01 00:00:00