Abstract:
OBJECTIVES:Auditory temporal processing frequently appears more affected in old subjects than would be predicted by the degree of peripheral hearing loss, pointing to an age-dependent central processing deficit. In parallel, an age-dependent decline of inhibitory function has been demonstrated in the auditory pathway, suggesting a causal relationship between temporal processing and inhibition. Gabapentin has been specifically synthesized as a potential gamma-amino-butyric-acid (GABA) mimetic with the capability to cross the blood-brain barrier. Gabapentin treatment ameliorated tinnitus in a rat model and improved tinnitus annoyance in humans with acoustic trauma. Consequently, the present study evaluated the effect of gabapentin on auditory temporal processing in the gerbil model. DESIGN:Psychometric functions were collected for different test paradigms. (A) "Gap detection": The detection of a gap in the middle of a 800 msec broadband noise pulse was determined either at 15 or at 30 dB SL. (B) "Forward masking": The detection of a 20 msec probe stimulus following 2.5 msec after a 400 msec 40 dB SPL masker was determined with masker and probe frequency at 2.85 kHz. The effect of gabapentin was evaluated by collecting gap detection and forward masking functions before, during, and after treating gerbils with gabapentin doses of 115 or 350 mg/kg/day administered via drinking water. Data under different experimental conditions were collected for groups of 3 to 5 young (<2 years) and 6 to 10 old (>2 years) gerbils. Two-way analyses of variance for the factors age groups and treatment groups with subsequent pairwise comparisons for significant effects were used for the statistical evaluation of the data. RESULTS:For gap detection, mean thresholds were significantly increased in the group of old as compared with the young gerbils at 30 dB SL (young 2.0 msec; old 3.2 msec) and at 15 dB SL (young 2.9 msec; old 9.1 msec). Gabapentin had no significant effect on gap detection, and there was no significant interaction between age group and gabapentin treatment. Mean thresholds in the forward masking paradigm were significantly elevated in old (45.5 dB SPL) as compared with young (35.0 dB SPL) gerbils. Overall, gabapentin had no significant effect on masked thresholds; however, there was a significant interaction between treatment and age. Subsequent pairwise comparisons revealed no significant effect on masked thresholds in old gerbils but showed significantly elevated thresholds of young gerbils during 350 mg/kg gabapentin (38.3 dB SPL) compared with thresholds obtained in young gerbils before (32.3 dB SPL) and after (33.5 dB SPL) treatment. CONCLUSIONS:Gabapentin did not exert a therapeutic effect on impaired gap detection and forward masking in old gerbils. The lack of an effect of gabapentin on impaired auditory temporal processing in old gerbils and the finding of elevated masked thresholds in young gerbils can be reconciled with reports of only moderate GABAergic effects compared with other drugs (e.g., comparing elevation of GABA levels in the brain by gabapentin and vigabatrin) and effects due to binding of gabapentin to alpha-2-delta units of voltage-gated calcium channels.
journal_name
Ear Hearjournal_title
Ear and hearingauthors
Gleich O,Strutz Jdoi
10.1097/AUD.0b013e318222289fsubject
Has Abstractpub_date
2011-11-01 00:00:00pages
741-9issue
6eissn
0196-0202issn
1538-4667journal_volume
32pub_type
杂志文章相关文献
EAR AND HEARING文献大全abstract::A computer-automated, threshold-tracking procedure was developed for measuring evoked response thresholds on-line. The procedure utilizes an objective detection criterion (correlation) to evaluate whether a response is absent or present. Sound intensity is adjusted according to a modified PEST (parameter estimation by...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:
更新日期:1987-06-01 00:00:00
abstract::A patient-wearable, single-electrode cochlear implant was first used by a patient in 1972 at the House Ear Institute. Since early 1982, a redesigned version of this system has been in clinical use. This new system, called the 3M House cochlear implant system, consists of an implanted receiver and a patient-worn signal...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:
更新日期:1985-05-01 00:00:00
abstract:OBJECTIVES:The purpose of this investigation was to determine whether the use of visual feedback of tonic electromyographic (EMG) activity, or the use of amplitude normalization techniques would reduce significantly the variability in cervical vestibular evoked myogenic potential (cVEMP) P13-N23 interaural amplitude as...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31827ad792
更新日期:2013-07-01 00:00:00
abstract:OBJECTIVE:The aim was to compare outcomes in the domain of self-reported hearing handicap across groups of patients fit with one versus two cochlear implants (CI, CI + CI), or with an implant and a hearing aid (HA) in the nonimplanted ear (CI + HA). DESIGN:The design was retrospective, and a preliminary step was to fa...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31815d6da8
更新日期:2008-01-01 00:00:00
abstract::The present study investigated the effects of intensity on hearing-impaired adults' performance on the Staggered Spondaic Word (SSW) test. Fifteen adults having mild-to-moderate cochlear hearing losses were administered the 40-item SSW test which was subdivided into four groups of ten items each, and presented at diff...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198411000-00004
更新日期:1984-11-01 00:00:00
abstract:OBJECTIVES:Cochlear reflectance (CR) is the cochlear contribution to ear-canal reflectance. CR is a type of otoacoustic emission (OAE) that is calculated as a transfer function between forward pressure and reflected pressure. The purpose of this study was to compare wideband CR to distortion-product (DP) OAEs in two wa...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000677
更新日期:2019-07-01 00:00:00
abstract::Several cases illustrating potential pitfalls in neurotologic diagnosis from the viewpoint of the otologist are presented. The role of auditory brain stem response testing is specifically emphasized in cases with discordant audiologic and radiographic findings. Included are one case of a "false negative" ABR in a pati...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198804000-00007
更新日期:1988-04-01 00:00:00
abstract:OBJECTIVE:To evaluate the additional perceptual benefit provided to children through the use of two cochlear implants in comparison to one after 6 to 13 mo experience with sequential bilateral implants. DESIGN:A second cochlear implant was received by 11 children. The principal selection criteria were being age 4 to 1...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31806dc194
更新日期:2007-08-01 00:00:00
abstract::Averaged electrode voltages (AEVs) provide an objective measure of the output of the Nucleus multichannel cochlear implant device. AEVs are the peak-to-peak voltages of each electrode in the internal array and are recorded from electrodes placed on the scalp. This article summarizes average voltage data for 25 childre...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199404000-00007
更新日期:1994-04-01 00:00:00
abstract:OBJECTIVE:The paper aims to show how insertion gain responses can be translated into equivalent headphone responses, and vice versa. DESIGN:The relationship between the response types is theoretically derived by allowing for real ear to coupler differences and for real ear unaided responses. RESULTS:The necessary cor...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199708000-00009
更新日期:1997-08-01 00:00:00
abstract:OBJECTIVES:This systematic review aimed to investigate the prevalence and characteristics of vestibular adverse effects of aminoglycoside (AG) therapy in humans and to analyze objective vestibular tests for the detection of AG-induced vestibulotoxicity. DESIGN:PubMed, Cochrane Database, Web of Science, and reference l...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/AUD.0000000000000458
更新日期:2017-11-01 00:00:00
abstract::The failure to include only relevant observations in the assessment of laterality has resulted in a proliferation of post hoc attempts to "correct" laterality measures influenced by "overall performance level." The inclusion of information from trials in which both ears were either correct or in error contaminates the...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198405000-00010
更新日期:1984-05-01 00:00:00
abstract::Auditory brain stem response waveforms, derived from normal ears, were analyzed with a computer-based digital filtering program as a means of systematically evaluating the effects of phase-shift distortion. Off-line analysis involved the stimulated responses of a Butterworth-type filter at five high-pass and four low-...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198612000-00006
更新日期:1986-12-01 00:00:00
abstract:OBJECTIVE:Cochlear implant patients have difficulty in noisy environments, in part, because of channel interaction. Interleaving the signal by sending every other channel to the opposite ear has the potential to reduce channel interaction by increasing the space between channels in each ear. Interleaving still potentia...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000249
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVES:Clinicians sometimes treat patients with relatively long-duration geotropic direction-changing positional nystagmus (DCPN), without latency. Recently, the concept of a "light cupula" in the lateral canal that reveals persistent geotropic DCPN has been introduced. In the present study, we investigated the imm...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000232
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to describe normal characteristics of distortion product otoacoustic emission (DPOAE) signal and noise level in a group of newborns and infants with normal hearing followed longitudinally from birth to 15 months of age. DESIGN:This is a prospective, longitudinal study of 231 in...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000542
更新日期:2018-09-01 00:00:00
abstract::Some initial experiences are described in which ear canal probe tube microphone measurements are used to determine hearing aid settings for children. Decisions are based upon ideas developed by Seewald and Ross (in Amplification for the Hearing Impaired, New York: Grune & Stratton, 1988: 213-267) and Seewald, Ross, an...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198910000-00002
更新日期:1989-10-01 00:00:00
abstract::The amount of acoustic radiation produced by two samples of a Radioear B-71, B-72, and Pracitronic KH 70 bone vibrator was determined for 30 normal-hearing subjects at 4000 Hz. The mean amount of acoustic radiation was very similar for both samples of each vibrator type but significantly (p less than 0.05) different b...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198610000-00010
更新日期:1986-10-01 00:00:00
abstract::This study is a follow-up of an 1980-1982 study that examined the occurrence of risk factors and the patterns of identification and habilitation in a group of hearing-impaired infants from an urban setting. Current findings covering the period 1983-1988, indicate that only one out of three hearing-impaired infants can...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199006000-00006
更新日期:1990-06-01 00:00:00
abstract:OBJECTIVES:Multiple auditory steady state responses (ASSRs) will likely be included in the diagnostic test battery for estimating infant auditory thresholds in the near future; however, the effects of single- versus multiple-stimulus presentation in infants has never been investigated. In adults, there are no interacti...
journal_title:Ear and hearing
pub_type: 临床试验,杂志文章
doi:10.1097/AUD.0b013e3181ff352c
更新日期:2011-05-01 00:00:00
abstract:OBJECTIVES:To compare the sound-source localization, discrimination, and tracking performance of bilateral cochlear implant users with omnidirectional (OMNI) and pinna-imitating (PI) microphone directionality modes. DESIGN:Twelve experienced bilateral cochlear implant users participated in the study. Their audio proce...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000912
更新日期:2020-07-16 00:00:00
abstract:OBJECTIVE:The main aim of the present study was to compare the derived and directly measured real-ear hearing instrument performance for a range of commonly used hearing instruments. A secondary aim was to compare the real-ear to coupler difference (RECD) measured using the ER-3A insert earphone and a selection of hear...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.aud.0000224123.22568.82
更新日期:2006-08-01 00:00:00
abstract:OBJECTIVES:(1) To determine the ototoxicity detection rate (sensitivity) for distortion-product otoacoustic emissions (DPOAEs) testing in adults who received ototoxic medications and experienced pure-tone threshold changes during the course of treatment; (2) to determine the extent to which DPOAE sensitivity to ototoxi...
journal_title:Ear and hearing
pub_type: 临床试验,杂志文章
doi:10.1097/AUD.0b013e318181ad99
更新日期:2008-12-01 00:00:00
abstract::Paired comparison perception and preference judgments of hearing aid processed music were examined under conditions of extended and reduced high and low-frequency ranges. The performance of 20 subjects with mild to moderate hearing impairment was compared with an equal number of normal hearing controls. Subjects with ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198201000-00004
更新日期:1982-01-01 00:00:00
abstract:OBJECTIVES:The most commonly employed speech processing strategies in cochlear implants (CIs) only extract and encode amplitude modulation (AM) in a limited number of frequency channels. proposed a novel speech processing strategy that encodes both frequency modulation (FM) and AM to improve CI performance. Using behav...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000756
更新日期:2020-03-01 00:00:00
abstract:OBJECTIVES:Cochlear implants (CIs) are increasingly recommended to individuals with residual bilateral acoustic hearing. Although new hearing-preserving electrode designs and surgical approaches show great promise, CI recipients are still at risk to lose acoustic hearing in the implanted ear, which could prevent the ab...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000420
更新日期:2017-09-01 00:00:00
abstract::Humans have evolved the unique capacity to efficiently communicate using the spoken word. Hearing plays a key role as a receiver in this process and dysfunction leads to difficulties in listening and communication. It is widely accepted that effective communication is not adequately captured with current behavioral sp...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000939
更新日期:2020-11-01 00:00:00
abstract:OBJECTIVES:Diet may affect susceptibility of the inner ear to noise and age-related effects that lead to tinnitus and hearing loss. This study used complementary single nutrient and dietary pattern analysis based on statistical grouping of usual dietary intake in a cross-sectional analysis of tinnitus and hearing diffi...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000765
更新日期:2020-03-01 00:00:00
abstract::In recent years there has been an increased acceptance of the cochlear implant as an appropriate sensory aid for selected hearing-impaired individuals with profound losses. With the Food and Drug Administration's release of the 3M/House single channel cochlear implant on November 29, 1984 and the Nucleus 22-channel co...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198604000-00003
更新日期:1986-04-01 00:00:00
abstract:OBJECTIVES:To evaluate the influence of auditory cues on postural sway in normal-hearing (NH) individuals, hearing-impaired individuals with vestibular impairment (HIVL), or hearing-impaired (HI) individuals without vestibular impairment. DESIGN:Thirty-two participants received a hearing and a vestibular evaluation (v...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000720
更新日期:2019-11-01 00:00:00