Quantification evaluation of 99mTc-MDP concentration in the lumbar spine with SPECT/CT: compare with bone mineral density.

Abstract:

BACKGROUND:Despite recent technological advances allowing for quantitative single-photon emission computed tomography (SPECT), quantitative SPECT has not been widely used in the clinical practice of osteoporosis. The aim of this study is to evaluate the feasibility of quantitative bone SPECT/CT for measuring lumbar standard uptake value (SUV) in patients with different bone-mineral density (BMD), and investigate the correlation between SUV measured with 99mTc-methylene diphosphonate (MDP) SPECT/CT and BMD assessment by dual-energy X-ray absorptiometry (DXA). METHODS:A retrospective analysis of 62 cases 99mTc-MDP whole-body bone imaging and local lumbar SPECT/CT tomography were performed. According to the results of dual-energy X-ray bone density examination, they were divided into normal group, osteopenic group, and osteoporosis group. The raw SPECT data were reconstructed using flash3D which includes attenuation correction, scatter compensation, and collimator resolution recovery, SPECT images from this algorithm were calibrated for SUV analysis. Comparing difference of lumbar SUV in different BMD subjects, and investigating the correlation between lumbar SUV and BMD. Data were analyzed by one-way ANOVA and Pearson regression analysis using SPSS 17.0 software. RESULTS:The maximum SUV (SUVmax) and mean SUV (SUVmean) of L1-L4 vertebral in 62 subjects were 7.39 ± 1.84 and 4.90 ± 1.27, respectively. The average BMD was 0.85 ± 0.15 (g/cm2), and the average CT value was 145.88 ± 53.99 (HU). The SUVmax, SUVmean, BMD, and CT values of the lumbar spine were statistically significantly different among the three groups (F = 24.089, 30.501, 94.847, 30.241, all p < 0.001), and the osteopenic group was significantly lower than the normal group (all p < 0.001), the osteoporosis group was significantly lower than the normal group and the osteopenic group (all p < 0.001). Lumbar SUVmax, SUVmean, and BMD were significantly negatively correlated with age (r = - 0.328 to - 0.442, all p < 0.05), and positively correlated with body weight and CT value (r = 0.299-0.737, all p < 0.05), but no significant correlation with height (r = 0.006-0.175, all p > 0.05). Lumbar SUVmax and SUVmean increased significantly with the increase of BMD (r = 0.638, 0.632, p < 0.001). CONCLUSION:The SUV of lumbar spine in 99mTc-MDP bone SPECT/CT was significantly different among subjects with different BMD, and the SUV was positively correlated with BMD. These findings justify that quantitative bone SPECT/CT is an applicable tool for clinical quantification of bone metabolism in osteoporosis patients.

journal_name

Ann Nucl Med

authors

Huang K,Feng Y,Liu D,Liang W,Li L

doi

10.1007/s12149-019-01425-x

subject

Has Abstract

pub_date

2020-02-01 00:00:00

pages

136-143

issue

2

eissn

0914-7187

issn

1864-6433

pii

10.1007/s12149-019-01425-x

journal_volume

34

pub_type

杂志文章
  • Diagnosis of maxillofacial tumor with L-3-[18f]-fluoro-alpha-methyltyrosine (FMT) PET: a comparative study with FDG-PET.

    abstract:OBJECTIVES:To compare L-3-[18F]-fluoro-a-methyltyrosine (FMT)-positron emission tomography (PET) and 2-[18F]-fluoro-2-deoxy-D-glucose (FDG)-PET in the differential diagnosis of maxillofacial tumors. METHODS:This study included 36 patients (16 males, 20 females; 31-90 years old) with untreated malignant tumors (34 squa...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03033991

    authors: Miyakubo M,Oriuchi N,Tsushima Y,Higuchi T,Koyama K,Arai K,Paudyal B,Iida Y,Hanaoka H,Ishikita T,Nakasone Y,Negishi A,Mogi K,Endo K

    更新日期:2007-02-01 00:00:00

  • Novel algorithm for quantitative assessment of left ventricular dyssynchrony with ECG-gated myocardial perfusion SPECT: useful technique for management of cardiac resynchronization therapy.

    abstract:OBJECTIVES:Cardiac resynchronization therapy (CRT) is the established treatment for patients with chronic and severe heart failure, and it has been reported that the presence of left ventricular (LV) dyssynchrony is one of the most important factors which predict positive response of this therapy. In the present study,...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/s12149-011-0525-8

    authors: Kiso K,Imoto A,Nishimura Y,Kanzaki H,Noda T,Kamakura S,Ishida Y

    更新日期:2011-12-01 00:00:00

  • New semiquantitative assessment of 123I-FP-CIT by an anatomical standardization method.

    abstract:UNLABELLED:We evaluated a new semiquantitative procedure to more easily and objectively estimate the striatal uptake of 123I-FP-CIT in patients with Parkinsonian syndrome (PS) and essential tremor (ET), using an anatomical standardization method, the Neurostat. METHODS:Eleven patients with PS and 8 with ET were examin...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02987257

    authors: Takada S,Yoshimura M,Shindo H,Saito K,Koizumi K,Utsumi H,Abe K

    更新日期:2006-08-01 00:00:00

  • High detection sensitivity and reliable morphological correlation of PET with a silicon photomultiplier for primary tongue squamous cell carcinoma.

    abstract:OBJECTIVE:A positron emission tomography (PET) scanner using a silicon photomultiplier (SiPM PET) in place of a photomultiplier tube significantly improves the spatial and time resolution. It may also improve the evaluation of smaller lesions compared to conventional (non-SiPM) PET scanners. We compared the maximum sta...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01489-0

    authors: Kojima I,Takanami K,Ogawa T,Sakamoto M,Nagai H,Miyashita H,Iikubo M

    更新日期:2020-09-01 00:00:00

  • An animal PET scanner using flat-panel position-sensitive PMTs.

    abstract:OBJECTIVE:To design, build, and evaluate an animal PET scanner, which can be used with non-human primates under conscious condition, incorporating flat-panel position-sensitive photomultiplier tubes (PS-PMTs). METHODS:The system contains 30 detector modules, each having two PS-PMTs and 16×18 lutetium–yttrium oxyortho-...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-013-0772-y

    authors: Okamoto T,Ote K,Sakai K,Noda A,Shimizu K,Masuda K,Ohmura T,Watanabe M

    更新日期:2014-01-01 00:00:00

  • Myocardial accumulation of a dopamine D2 receptor-binding radioligand, 2'-iodospiperone.

    abstract::125I-2'-iodospiperone (2'-ISP), which has a high and selective affinity for dopamine D2 receptors, produced a high myocardial accumulation of radioactivity in the early phase after intravenous injection into mice. A human scintigraphic study also showed that the myocardium was clearly visualized soon after intravenous...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164959

    authors: Saji H,Yonekura Y,Tanahashi K,Iida Y,Iwasaki Y,Magata Y,Konishi J,Yokoyama A

    更新日期:1993-08-01 00:00:00

  • Uptake and washout of I-123-MIBG in neuronal and non-neuronal sites in rat hearts: relationship to renal clearance.

    abstract::We investigated the uptake and washout of I-123-metaiodobenzylguanidine (MIBG) in neuronal (both intra- and extravesicular) and non-neuronal sites in the heart and its relationship to renal clearance. Acute renal failure was induced in rats by ligating the renal vessels, and the findings were compared with those of sh...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03165394

    authors: Arbab AS,Koizumi K,Araki T

    更新日期:1996-05-01 00:00:00

  • Evaluation of the bubble point test of a 0.22-μm membrane filter used for the sterilizing filtration of PET radiopharmaceuticals.

    abstract:OBJECTIVE:We developed a bubble point test kit and investigated the bubble point test of a 0.22-μm membrane filter used for the sterilizing filtration of [(18)F]FDG, [(11)C]MET and [(11)C]PIB. The bubble point test of the Millex-GS vented filter was often difficult due to air leakage from the vented portion of this fil...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-014-0830-0

    authors: Hayashi K,Douhara K,Kashino G

    更新日期:2014-07-01 00:00:00

  • Evaluation of a direct 4D reconstruction method using generalised linear least squares for estimating nonlinear micro-parametric maps.

    abstract:OBJECTIVE:Estimation of nonlinear micro-parameters is a computationally demanding and fairly challenging process, since it involves the use of rather slow iterative nonlinear fitting algorithms and it often results in very noisy voxel-wise parametric maps. Direct reconstruction algorithms can provide parametric maps wi...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-014-0881-2

    authors: Angelis GI,Matthews JC,Kotasidis FA,Markiewicz PJ,Lionheart WR,Reader AJ

    更新日期:2014-11-01 00:00:00

  • Comparison of radioactive iodide uptake in the rat thyroid between oral and intravenous bolus administration.

    abstract:OBJECTIVE:Radioiodide is commonly used to diagnose and treat hyperthyroidism and thyroid carcinoma. However, we could not find any experimental data that strictly compared the biodistribution and thyroid uptake of radioactive iodide between the oral and intravenous (iv) routes with time. This prompted us to compare (12...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-014-0909-7

    authors: Kurosawa H,Sakurai K,Hasegawa H,Uchida K,Kasahara H,Minamizawa T,Nakajo M,Nakajo M

    更新日期:2014-12-01 00:00:00

  • Assessment of hepatic functional regeneration after hepatectomy using (99m)Tc-GSA SPECT/CT fused imaging.

    abstract:BACKGROUND:The liver itself regenerates after hepatectomy but little is known about how much hepatic function recovers during the regeneration. The liver uptake value (LUV), calculated from Tc-99m-labeled galactosyl-human-serum-albumin ((99m)Tc-GSA) SPECT/CT fused images, is reliable and useful for evaluating hepatic f...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-014-0872-3

    authors: Yoshida M,Shiraishi S,Sakamoto F,Beppu T,Utsunomiya D,Okabe H,Tomiguchi S,Baba H,Yamashita Y

    更新日期:2014-10-01 00:00:00

  • Potential utility of bone scan in cranial bone flap osteomyelitis.

    abstract:OBJECTIVE:Currently, the diagnosis of bone flap osteomyelitis (BFO) remains a challenge for medical imaging. The present study aimed to identify predictive scintigraphic patterns of BFO. METHODS:This retrospective study reviewed planar bone scan of patients with suspected BFO between 2010, and 2016. A total of 15 pati...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-019-01351-y

    authors: Bani Sadr A,Gregoire B,Tordo J,Guyotat J,Boibieux A,Janier M

    更新日期:2019-06-01 00:00:00

  • A large degenerated subserous leiomyoma of the uterus: uncommon scintigraphic and ultrasonographic findings.

    abstract::Bone imaging is commonly used as a sensitive indicator of metastatic bone diseases or other bone pathology. Furthermore, it is now generally known that technetium-99m (99mTc) phosphonates tend to concentrate in various tissues other than bones. Ultrasonography is also widely used for the evaluation of pelvic masses. U...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164568

    authors: Inoue H,Aizawa N,Mizuno T,Akashi T,Shimizu T,Fukushima Y,Suzuki Y

    更新日期:1989-03-01 00:00:00

  • Characteristics and trends of research on positron emission tomography: a bibliometric analysis, 2002-2012.

    abstract:OBJECTIVE:We performed a bibliometric analysis of scientific publications focused on positron emission tomography (PET) over a 10-year period. METHODS:The MEDLINE and ISI Web of Knowledge databases were searched for English language original articles focused on PET in SCI/SCIE-indexed journals in 2002, 2007, and 2012....

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-014-0836-7

    authors: Baek S,Yoon DY,Min KJ,Lim KJ,Seo YL,Yun EJ

    更新日期:2014-06-01 00:00:00

  • Causes of false negatives in technetium-99 m methoxyisobutylisonitrile scintigraphy for hyperparathyroidism: influence of size and cysts in parathyroid lesions.

    abstract:OBJECTIVE:The aim of this study was to elucidate the causes of false-negative cases of technetium-99 m methoxyisobutylisonitrile scintigraphy (MIBI) for hyperparathyroidism. METHODS:Consecutive MIBI examinations performed in 154 patients between April 2011 and March 2017 were retrospectively reviewed. Sensitivities of...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01520-4

    authors: Ishii S,Sugawara S,Yaginuma Y,Kobiyama H,Hiruta M,Watanabe H,Yamakuni R,Hakozaki M,Fujimaki H,Ito H

    更新日期:2020-12-01 00:00:00

  • Double-phase (131)I whole body scan and (131)I SPECT-CT images in patients with differentiated thyroid cancer: their effectiveness for accurate identification.

    abstract:OBJECTIVE:This study aims to determine whether a (131)I double-phase whole body scan (WBS) and SPECT-CT images have added value over a single-phase WBS image in identifying benign and malignant lesions in patients with well-differentiated thyroid cancer (DTC) at their first radioactive iodine (RAI) treatment. METHODS:...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-011-0513-z

    authors: Wakabayashi H,Nakajima K,Fukuoka M,Inaki A,Nakamura A,Kayano D,Kinuya S

    更新日期:2011-11-01 00:00:00

  • An anthropomorphic pelvis phantom for optimization of the diagnosis of lymph node metastases in the pelvis.

    abstract:OBJECTIVE:An anthropomorphic pelvis phantom was made by the modification of a National Electrical Manufacturers Association (NEMA) phantom, currently the most popular one, and its clinical usefulness was evaluated. METHODS:The NEMA plus bone phantom was made by placing the pelvic bone model in the NEMA phantom. The NE...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-009-0229-5

    authors: Inoue K,Sato T,Kitamura H,Hirayama A,Kurosawa H,Tanaka T,Fukushi M,Moriyama N,Fujii H

    更新日期:2009-05-01 00:00:00

  • Esophageal transit study using a sliding sum image: application to patients with probable and definite systemic sclerosis.

    abstract:PURPOSE:Esophageal complication is common in systemic sclerosis (SSc), but scintigraphic transit patterns based on each subtype have not been understood well. The aim of this study was to develop a new algorithm for integrating a dynamic esophageal transit study and to apply the method to patients with SSc. METHODS:A ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-011-0465-3

    authors: Nakajima K,Hasegawa M,Inaki A,Wakabayashi H,Hosoya T,Takehara K,Kinuya S

    更新日期:2011-06-01 00:00:00

  • Assessment of liver function in chronic liver diseases and regional function of irradiated liver by means of 99mTc-galactosyl-human serum albumin liver scintigraphy and quantitative spectral analysis.

    abstract::Scintigraphy with 99mTc-diethylenetriamine pentaacetic acid galactosyl human serum albumin (99mTc-GSA) was performed on 102 patients, then the hepatic extraction fraction (HEF), the rate constant for liver uptake of the tracer from the blood (K1) and the hepatic blood flow index (HBFI) were determined by spectral anal...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02988293

    authors: Fukui A,Murase K,Tsuda T,Fujii T,Ikezoe J

    更新日期:2000-12-01 00:00:00

  • Bone scintigraphic and CT evaluation of chondrosarcoma of the rib: correlation with histological grade in 6 cases.

    abstract:OBJECTIVE:The objective of this study is to assess the value of CT and bone scintigraphic findings for grading of rib chondrosarcoma. METHODS:Included in this study were six cases of histologically proven chondrosarcoma of the rib, in which bone scintigraphy and/or CT was performed. Correlation of histologic grade (I-...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02984588

    authors: Ehara S,Nakayama T,Nishida J,Shiraishi H,Yoshioka H,Aoki J

    更新日期:2004-10-01 00:00:00

  • A trial for the quantification of regional myocardial blood flow with continuous infusion of Tc-99m MIBI and dynamic SPECT.

    abstract:UNLABELLED:We propose a new method to quantify regional myocardial blood flow (rMBF) by continuous infusion of Tc-99m MIBI and dynamic SPECT. METHODS:Five patients with old myocardial infarction were studied. During continuous infusion of MIBI (approximately 740 MBq) with a syringe pump in 10 min, dynamic SPECT scan w...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF03165431

    authors: Tsuchida T,Yonekura Y,Takahashi N,Nakano A,Lee JD,Sadato N,Yamamoto K,Waki A,Sugimoto K,Hayashi N,Ishii Y

    更新日期:1999-02-01 00:00:00

  • An assessment of bone-seeking radionuclides for palliation of metastatic bone pain in a vertebral model.

    abstract:OBJECTIVE:Bone-seeking radiopharmaceuticals have the main role in the treatment of painful bone metastases. The aim of this study was to dosimetrically compare radiopharmaceuticals in use for bone pain palliation therapy and bone scan. METHODS:The MCNPX code was used to simulate the radiation transport in a vertebral ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-019-01329-w

    authors: Sadremomtaz A,Masoumi M

    更新日期:2019-04-01 00:00:00

  • Comparison of FDG-PET, MRI and CT for post radiofrequency ablation evaluation of hepatic tumors.

    abstract:PURPOSE:Treatment effect of radiofrequency ablation (RFA) is traditionally accomplished with MRI and/or CT. The aim of the study was to assess the role of FDG-PET in post RFA hepatic tumor evaluation, in comparison with MRI and CT. MATERIALS AND METHODS:28 patients (33 hepatic RFA lesions) who had post RFA FDG-PET wit...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-012-0656-6

    authors: Chen W,Zhuang H,Cheng G,Torigian DA,Alavi A

    更新日期:2013-01-01 00:00:00

  • Unintentional human skeletal imaging with 99mTc-methylene diphosphonate 45 months beyond expiration.

    abstract::Eight patients were inadvertently administered, and imaged with, 99mTc-labeled MDP which was 45 months expired. Two cases are presented. All patients were subsequently imaged with normal MDP. The images obtained with expired MDP were clinically acceptable. No differences in scan abnormalities were observed compared wi...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164879

    authors: Riveros EG

    更新日期:1999-10-01 00:00:00

  • Tl-201 uptake and retention in a Warthin's tumor.

    abstract::We report scan findings of Tl-201 in a case of histologically proved Warthin's tumor. Dual isotopes acquisition was performed in a case of left parotid Warthin's tumor. Both early and delayed Tc-99m-pertechnetate (Tc-99m) images showed increased uptake at the tumor. Tl-201 scan also showed an increase of uptake on the...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164741

    authors: Arbab AS,Koizumi K,Arai T,Toyama K,Araki T

    更新日期:1996-08-01 00:00:00

  • Inferior mesenteric varix demonstrated by 99mTc-red blood cell gastrointestinal bleeding study.

    abstract::Reported here is a case of an inferior mesenteric varix demonstrated by 99mTc-red blood cell (RBC) scintigraphy performed for gastrointestinal bleeding in a 47-year-old man. It was shaped like a question mark ranging from the left upper abdomen to the pelvis. This is the first report of scintigraphic recognition of an...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164828

    authors: Yoshikai T,Yokomizo Y,Iwashita I,Okada Y,Koga H,Kudo S

    更新日期:1997-05-01 00:00:00

  • Assessment of human effective absorbed dose of 67 Ga-ECC based on biodistribution rat data.

    abstract:OBJECTIVE:In a diagnostic context, determination of absorbed dose is required before the introduction of a new radiopharmaceutical to the market to obtain marketing authorization from the relevant agencies. In this work, the absorbed dose of [67 Ga]-ethylenecysteamine cysteine [(67 Ga)ECC] to human organs was determine...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-014-0917-7

    authors: Shanehsazzadeh S,Yousefnia H,Lahooti A,Zolghadri S,Jalilian AR,Afarideh H

    更新日期:2015-02-01 00:00:00

  • Characteristics of single- and dual-photopeak energy window acquisitions with thallium-201 IQ-SPECT/CT system.

    abstract:OBJECTIVES:Although dual-energy (DE) acquisition with conventional 201Tl myocardial perfusion SPECT has several advantages such as improved attenuation of the inferior wall and increased acquisition counts, the characteristics of IQ-SPECT have not been fully evaluated. We evaluate the difference of characteristics betw...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-017-1177-0

    authors: Shibutani T,Onoguchi M,Yoneyama H,Konishi T,Matsuo S,Nakajima K,Kinuya S

    更新日期:2017-08-01 00:00:00

  • The prognostic role of end-of-treatment FDG-PET/CT in diffuse large B cell lymphoma: a pilot study application of neural networks to predict time-to-event.

    abstract:PURPOSE:To evaluate the prognostic role of end-of-treatment (EoT) FDG-PET/CT parameters in diffuse large B cell lymphoma (DLBCL), and then to explore a pilot application of Neural Networks (NN) in predicting time-to-relapse. METHODS:For conventional survival analysis, parameters as Deauville score (DS) and quantitativ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01542-y

    authors: Annunziata S,Pelliccioni A,Hohaus S,Maiolo E,Cuccaro A,Giordano A

    更新日期:2021-01-01 00:00:00

  • Detection of local recurrence of prostate cancer after radical prostatectomy: Is there a role for early ¹⁸F-FCH PET/CT?

    abstract:AIM:To investigate the diagnostic performance of early acquisition compared to late imaging for the detection of local recurrence of prostate cancer by means of ¹⁸F-FCH PET/CT. MATERIALS AND METHODS:99 patients with radical prostatectomy (mean PSA 3.9 ± 5.03) were subjected to early dynamic PET/CT acquisition of the p...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-015-1015-1

    authors: Di Biagio D,Chiaravalloti A,Tavolozza M,Abbatiello P,Schillaci O

    更新日期:2015-12-01 00:00:00