Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate.

Abstract:

PURPOSE:This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostate brachytherapy, biopsy and other interventional procedures. Furthermore, an evaluation of currently established water-bath based quality assurance (QA) procedures is presented. MATERIAL AND METHODS:Image acquisitions of an ultrasound QA setup were carried out at 5 MHz and 7 MHz. The U/S probe was covered by EA 4015 Silicone Standoff kit, or UA0059 Endocavity balloon filled either with water or one of the following: 40 ml of Endosgel(®), Instillagel(®), Ultraschall gel or Space OAR™ gel. The differences between images were recorded. Consequently, the dosimetric impact of the observed image distortion was investigated, using a tissue equivalent ultrasound prostate phantom - Model number 053 (CIRS Inc., Norfolk, VA, USA). RESULTS:By using the EA 4015 Silicone Standoff kit in normal water with sound speed of 1525 m/s, a 3 mm needle shift was observed. The expansion of objects appeared in radial direction. The shift deforms also the PTV (prostate in our case) and other organs at risk (OARs) in the same way leading to overestimation of volume and underestimation of the dose. On the other hand, Instillagel(®) and Space OAR™ "shrinks" objects in an ultrasound image for 0.65 mm and 0.40 mm, respectively. CONCLUSIONS:The use of EA 4015 Silicone Standoff kit for image acquisition, leads to erroneous contouring of PTV and OARs and reconstruction and placement of catheters, which results to incorrect dose calculation during prostate brachytherapy. Moreover, the reliability of QA procedures lies mostly in the right temperature of the water used for accurate simulation of real conditions of transrectal ultrasound imaging.

authors

Diamantopoulos S,Milickovic N,Butt S,Katsilieri Z,Kefala V,Zogal P,Sakas G,Baltas D

doi

10.5114/jcb.2011.26472

subject

Has Abstract

pub_date

2011-12-01 00:00:00

pages

209-19

issue

4

eissn

1689-832X

issn

2081-2841

pii

17926

journal_volume

3

pub_type

杂志文章
  • Short-term clinical outcome and dosimetric comparison of tandem and ring versus tandem and ovoids intracavitary applicators.

    abstract:PURPOSE:To compare the short-term toxicity and dosimetry of tandem and ring (TR), and tandem and ovoid (TO) applicators in treatment of gynecologic malignancy. MATERIAL AND METHODS:Following pelvic external beam radiation therapy (EBRT), a total of 52 computed tomography-based plans from 13 patients with cervical canc...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2015.51853

    authors: Ma JK,Mourad WF,Allbright R,Packianathan S,Harrell LM,Chinchar E,Nguyen A,Vijayakumar S

    更新日期:2015-06-01 00:00:00

  • The role of interstitial brachytherapy in the management of primary radiation therapy for uterine cervical cancer.

    abstract:PURPOSE:The aim of this study was to report the clinical results of uterine cervical cancer patients treated by primary radiation therapy including brachytherapy, and investigate the role of interstitial brachytherapy (ISBT). MATERIAL AND METHODS:All consecutive uterine cervical cancer patients who were treated by pri...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2016.62938

    authors: Murakami N,Kobayashi K,Kato T,Nakamura S,Wakita A,Okamoto H,Shima S,Tsuchida K,Kashihara T,Harada K,Takahashi K,Umezawa R,Inaba K,Ito Y,Igaki H,Itami J

    更新日期:2016-10-01 00:00:00

  • Dose-volume analysis of target volume and critical structures in computed tomography image-based multicatheter high-dose-rate interstitial brachytherapy for head and neck cancer.

    abstract:Purpose:To evaluate dose-volume relationships of target volume and critical structures in computed tomography (CT) image-based brachytherapy for head and neck cancer. Material and methods:Thirty-seven patients with mobile tongue, floor of mouth, and base of tongue cancer treated with brachytherapy (post-operative alon...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.72581

    authors: Akiyama H,Major T,Polgár C,Takácsi-Nagy Z

    更新日期:2017-12-01 00:00:00

  • Image-guided high-dose-rate interstitial brachytherapy - a valuable salvage treatment approach for loco-regional recurrence of papillary thyroid cancer.

    abstract:PURPOSE:To report the treatment effect of image-guided high-dose-rate (HDR) interstitial brachytherapy for refractory recurrence of papillary thyroid cancer (PTC). CASE REPORT:This 66-year-old female presented with recurrence 5 years after thyroidectomy for PTC. Despite external irradiation and radioactive (131)I, the...

    journal_title:Journal of contemporary brachytherapy

    pub_type:

    doi:10.5114/jcb.2016.59127

    authors: Wu N,Zhao H,Han D,Cheng G,Zhao Z,Ge Y

    更新日期:2016-04-01 00:00:00

  • Dosimetric comparison of Acuros™ BV with AAPM TG43 dose calculation formalism in breast interstitial high-dose-rate brachytherapy with the use of metal catheters.

    abstract:PURPOSE:Radiotherapy for breast cancer includes different techniques and methods. The purpose of this study is to compare dosimetric calculations using TG-43 dose formalism and Varian Acuros™ BV (GBBS) dose calculation algorithm for interstitial implant of breast using metal catheters in high-dose-rate (HDR) brachyther...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2015.54052

    authors: Sinnatamby M,Nagarajan V,Reddy K S,Karunanidhi G,Singhavajala V

    更新日期:2015-08-01 00:00:00

  • Carotid dosimetry after re-irradiation with 131Cs permanent implant brachytherapy in recurrent, resected head and neck cancer.

    abstract:Purpose:Permanent seed implant cesium-131 (131Cs) brachytherapy provides highly localized radiation for patients with recurrent head and neck cancer (HNC), who may be ineligible for external beam radiation therapy due to a high-risk of toxicity. As carotid blowout is a concern in the setting of re-irradiation, a dose t...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.86298

    authors: Walsh A,Hubley E,Doyle L,Cognetti D,Curry J,Bar-Ad V,Luginbuhl A

    更新日期:2019-06-01 00:00:00

  • Treatment planning study of the 3D dosimetric differences between Co-60 and Ir-192 sources in high dose rate (HDR) brachytherapy for cervix cancer.

    abstract:PURPOSE:To evaluate whether Co-60 is equivalent to Ir-192 for HDR cervical brachytherapy, through 3D-DVH dose comparisons in standard and optimised plans. Previous studies have only considered 2D dosimetry, point dose comparisons or identical loading. Typical treatment times and economics are considered. MATERIAL AND ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2012.27952

    authors: Palmer A,Hayman O,Muscat S

    更新日期:2012-03-01 00:00:00

  • MRI assisted cervix cancer brachytherapy pre-planning, based on insertion of the applicator in para-cervical anaesthesia: preliminary results of a prospective study.

    abstract:PURPOSE:To report on preliminary results of a prospective study on MRI-assisted cervix cancer brachytherapy pre-planning. MATERIAL AND METHODS:In six locally advanced cervix cancer patients, five days before the first brachytherapy fraction, tandem & ring applicator was inserted under para-cervical anaesthesia, MRI pe...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:

    authors: Petric P,Hudej R,Music M

    更新日期:2009-10-01 00:00:00

  • Time to failure after definitive therapy for prostate cancer: implications for importance of aggressive local treatment.

    abstract:PURPOSE:To explore patterns of time to failure in men receiving high doses of permanent seed brachytherapy with or without external beam radiation therapy as a function of risk status. MATERIAL AND METHODS:Two thousand two hundred and thirty four patients were treated with prostate brachytherapy with median follow up ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2013.39210

    authors: Taira AV,Merrick GS,Butler WM,Galbreath RW,Fiano R,Wallner KE,Adamovich E

    更新日期:2013-12-01 00:00:00

  • The impact of inter-fraction changes for perineal template-based interstitial gynecologic brachytherapy implants.

    abstract:Purpose:Perineal template-based interstitial gynecologic brachytherapy (ISBT) treatments are evaluated to determine whether adaptive inter-fraction re-planning is beneficial and necessary to meet the treatment aims of the American Brachytherapy Society (ABS) consensus guidelines for interstitial brachytherapy. Adherenc...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.84420

    authors: Belliveau JG,Thind K,Banerjee R,Quirk S,Doll C,Phan T,Meyer T,Roumeliotis M

    更新日期:2019-04-01 00:00:00

  • Inter-institutional comparison of treatment practice for cervical cancer with special emphasis on brachytherapy.

    abstract:Purpose:To compare the cervical cancer treatment outcome and toxicities between two different institutions. Material and methods:We analysed the clinical outcome of cervical cancer patients treated at two different centres from January 2015 to December 2016. Centre A treated 72 patients by external beam radiotherapy (...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.88582

    authors: Ravindran E,Kumar M,Gururajachar JM,Thangaraj R

    更新日期:2019-10-01 00:00:00

  • Multisector dosimetry in the immediate post-implant period: significant under dosage of the prostate base.

    abstract:PURPOSE:While there are several reports of prostate multisector dosimetry data obtained from CT or MRI scans performed at intervals ranging from 14-70 days after prostate brachytherapy (PB), there are no reports on multisector dosimetry performed in the immediate post-implant period. This study was undertaken to determ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2014.42023

    authors: Kirschner AN,Sathiaseelan V,Zhang Y,David J,Kalapurakal JA

    更新日期:2014-03-01 00:00:00

  • Image-guided high-dose-rate intracavitary brachytherapy technique for nasal keloid - a case report.

    abstract::The aim of this study is to report an uncommon case of nasal keloid treated with adaptive image-guided high-dose-rate (HDR) intracavitary brachytherapy. A 34-year-old female presented with nasal keloid after facial trauma was treated with scar resection and HDR intracavitary brachytherapy with a customized eccentric a...

    journal_title:Journal of contemporary brachytherapy

    pub_type:

    doi:10.5114/jcb.2018.76838

    authors: Huang C,He M,Zhao H,Cheng PG

    更新日期:2018-06-01 00:00:00

  • Comparison of post-implant dosimetrics between intraoperatively built custom-linked seeds and loose seeds by sector analysis at 24 hours and 1 month for localized prostate cancer.

    abstract:Purpose:To compare post-implant dosimetrics between intraoperatively built custom-linked (IBCL) seeds and loose seeds (LS) at 24 hours and 1 month by sector analysis, and to evaluate the effect of IBCL seeds with regard to change in dosimetric parameters, in patients with prostate cancer treated with brachytherapy. Ma...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2020.98110

    authors: Okazaki E,Kuratsukuri K,Nishikawa T,Tanaka T,Sakagami M,Shibuya K

    更新日期:2020-08-01 00:00:00

  • Routine use of ultrasound guided tandem placement in intracavitary brachytherapy for the treatment of cervical cancer - a South Indian institutional experience.

    abstract:PURPOSE:Intracavitary brachytherapy necessitates the insertion of a tandem applicator through the cervical os into the uterine cavity. Blind insertion of the tandem may result in suboptimal tandem placement. This decreases the control of the tumor locally and may result in uterine perforation. Although routine real tim...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2014.55115

    authors: Rao PB,Ghosh S

    更新日期:2015-10-01 00:00:00

  • High-dose-rate interstitial brachytherapy in head and neck cancer: do we need a look back into a forgotten art - a single institute experience.

    abstract:PURPOSE:To evaluate the treatment outcomes with high-dose-rate (HDR) interstitial brachytherapy (HDR-BRT) in head and neck cancers (HNC). MATERIAL AND METHODS:Fifty-eight patients with HNC as per American Joint Committee on Cancer (AJCC) TNM staging criteria were analyzed retrospectively between 2008 and 2015. Forty-t...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.67147

    authors: Bhalavat R,Chandra M,Pareek V,Nellore L,George K,Nandakumar P,Bauskar P

    更新日期:2017-04-01 00:00:00

  • High-dose-rate brachytherapy in treatment of non-melanoma skin cancer of head and neck region: preliminary results of a prospective single institution study.

    abstract:Purpose:Skin cancers are the most common human malignancy with increasing incidence. Currently, surgery is standard of care treatment for non-melanoma skin cancers. However, brachytherapy is a growing modality in the management of skin cancers. Therefore, we aimed to assess the outcome of patients with non-melanoma ski...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2018.75596

    authors: Kalaghchi B,Esmati E,Ghalehtaki R,Gomar M,Jaberi R,Gholami S,Babaloui S,Nabavi M,Sotoudeh S,Khanjani N,Kazemian A,Amouzegar-Hashemi F,Aghili M,Lashkari M

    更新日期:2018-04-01 00:00:00

  • A novel method for vaginal cylinder treatment planning: a seamless transition to 3D brachytherapy.

    abstract:PURPOSE:Standard treatment plan libraries are often used to ensure a quick turn-around time for vaginal cylinder treatments. Recently there is increasing interest in transitioning from conventional 2D radiograph based brachytherapy to 3D image based brachytherapy, which has resulted in a substantial increase in treatme...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2012.29365

    authors: Malhotra HK,Wu V,Wang Z,Patil S

    更新日期:2012-06-01 00:00:00

  • High-dose-rate interstitial brachytherapy for liver metastases: first study from India.

    abstract:PURPOSE:To study the safety and efficacy of high-dose-rate interstitial brachytherapy (HDRIBT) in patients with liver metastases (LM). MATERIAL AND METHODS:Between 2009 and 2011, 10 patients with 12 metastatic lesions in the liver were enrolled in this prospective trial. All patients had either refused surgery or foun...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2013.36175

    authors: Sharma DN,Thulkar S,Sharma S,Gandhi AK,Haresh KP,Gupta S,Rath GK,Julka PK

    更新日期:2013-06-01 00:00:00

  • Clinical applications of custom-made vaginal cylinders constructed using three-dimensional printing technology.

    abstract:PURPOSE:Three-dimensional (3D) printing technology allows physicians to rapidly create customized devices for patients. We report our initial clinical experience using this technology to create custom applicators for vaginal brachytherapy. MATERIAL AND METHODS:Three brachytherapy patients with unique clinical needs we...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2016.60679

    authors: Sethi R,Cunha A,Mellis K,Siauw T,Diederich C,Pouliot J,Hsu IC

    更新日期:2016-06-01 00:00:00

  • EGSnrc Monte Carlo-aided dosimetric studies of the new BEBIG (60)Co HDR brachytherapy source.

    abstract:PURPOSE:The purpose of this study is to obtain the dosimetric parameters of the new BEBIG (60)Co brachytherapy source following by TG-43U1 recommendation with appropriate electron cutoff energy (0.521 MeV). MATERIAL AND METHODS:The new BEBIG (60)Co brachytherapy source is used to calculate the TG-43U1 parameters. EGSn...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2013.37419

    authors: Anwarul IM,Akramuzzaman MM,Zakaria GA

    更新日期:2013-09-01 00:00:00

  • Effectiveness and safety of a robot-assisted 3D personalized template in 125I seed brachytherapy of thoracoabdominal tumors.

    abstract:Purpose:This research aims to evaluate the effectiveness and safety of a robot-assisted 3D personalized template in 125I seed brachytherapy of thoracoabdominal tumors. Material and methods:Forty-three patients with different tumors were involved in this research between 2013 and 2015. They were all eligible to 125I se...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2018.77957

    authors: Ma X,Yang PZ,Jiang PS,Huo PB,Cao Q,Chai PS,Wang PH

    更新日期:2018-08-01 00:00:00

  • Current state of interventional radiotherapy (brachytherapy) education in Italy: results of the INTERACTS survey.

    abstract:Purpose:Increased complexity of interventional radiotherapy (brachytherapy - BT) treatment planning and quality control procedures has led to the need of a specific training. However, the details of the features of BT learning objectives and their distribution in the training paths of the Italian Radiation Oncology Sch...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2019.83137

    authors: Tagliaferri L,Kovács G,Aristei C,De Sanctis V,Barbera F,Morganti AG,Casà C,Pieters BR,Russi E,Livi L,Corvò R,Giovagnoni A,Ricardi U,Valentini V,Magrini SM,Directors of the Italian Radiation Oncology Schools.

    更新日期:2019-02-01 00:00:00

  • A comparative study of two reconstructive methods and different recommendations in intracavitary brachytherapy.

    abstract:PURPOSE:Intracavitary brachytherapy (ICB) is a widely used technique in the treatment of cervical cancer. In our Institute, we use different reconstructive methods in the conventional planning procedure. The main aim of this study was to compare these methods using critical organ doses obtained in various treatment pla...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2010.19498

    authors: Sresty NM,Ramanjappa T,Rao CR,Raju AK,Muralidhar KR

    更新日期:2010-12-01 00:00:00

  • Combined interstitial and surface high-dose-rate brachytherapy treatment of squamous cell carcinoma of the hand.

    abstract:Purpose:We present a case report of treatment using interstitial and surface high-dose-rate (HDR) brachytherapy for cutaneous squamous cell carcinoma (SCC) involving the interspace of the third and fourth digits. The patient refused two-ray amputation and the lesion was not amenable for external beam radiation therapy ...

    journal_title:Journal of contemporary brachytherapy

    pub_type:

    doi:10.5114/jcb.2020.92408

    authors: Kim DW,Buzurovic IM,Mahal BV,Hwang W,Oladeru OT,O'Farrell DA,Harris TC,Margalit DN,Lam M,Devlin PM

    更新日期:2020-02-01 00:00:00

  • Pain relief procedures before high-dose-rate brachytherapy for non-surgical treatment of cervix cancer.

    abstract::Cervical cancer (CC) is a neoplasm with great potential for prevention, but it is still an important public health problem in most developing countries. No significant difference is found in the literature between intracavitary high-dose-rate (HDR) and low-dose-rate (LDR) brachytherapy, when considering overall, disea...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2018.81027

    authors: Pellizzon ACA

    更新日期:2018-12-01 00:00:00

  • Single-fraction image-guided high-dose-rate brachytherapy for head and neck cancer: three cases of palliative brachytherapy.

    abstract:Purpose:To present a small series of cases, in which single-fraction image-guided high-dose-rate (HDR) brachytherapy was provided as palliative treatment for inoperable head and neck cancer cases. Material and methods:We used this technique to treat 3 patients with symptomatic head and neck cancer (tongue cancer, ging...

    journal_title:Journal of contemporary brachytherapy

    pub_type:

    doi:10.5114/jcb.2020.96870

    authors: Ota Y,Masui K,Suzuki G,Yamazaki H,Yamada K

    更新日期:2020-06-01 00:00:00

  • Single versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning.

    abstract:PURPOSE:To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. MATERIAL AND METHODS:We randomly selected...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2014.47816

    authors: Bahadur YA,Constantinescu C,Hassouna AH,Eltaher MM,Ghassal NM,Awad NA

    更新日期:2015-01-01 00:00:00

  • Dosimetry verification of 3D-printed individual template based on CT-MRI fusion for radioactive 125I seed implantation in recurrent high-grade gliomas.

    abstract:Purpose:To verify the accuracy and efficacy of three-dimensional printing individual template (3D-PIT) with computed tomography-magnetic resonance imaging (CT-MRI) fusion for radioactive iodine-125 (125I) seed implantation in high-grade brain gliomas. Material and methods:Between June 2017 and June 2018, 16 patients w...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.85729

    authors: Liu S,Wang H,Wang C,Zhang H,Li W,Dong Q,Hu X

    更新日期:2019-06-01 00:00:00

  • Does supplemental external beam radiation therapy impact urinary, bowel, and erectile function following permanent prostate brachytherapy?: results of two prospective randomized trials.

    abstract:Purpose:To evaluate the impact of supplemental external beam radiation therapy (EBRT) prior to permanent prostate brachytherapy on long term urinary, bowel, and erectile function. Material and methods:Patient administered urinary, bowel, and erectile quality of life (QoL) instrument were obtained prior to treatment an...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.70763

    authors: Merrick GS,Tennant A,Wallner KE,Galbreath R,Butler WM,Fiano R,Adamovich E

    更新日期:2017-10-01 00:00:00