Abstract:
PURPOSE:To compare the short-term toxicity and dosimetry of tandem and ring (TR), and tandem and ovoid (TO) applicators in treatment of gynecologic malignancy. MATERIAL AND METHODS:Following pelvic external beam radiation therapy (EBRT), a total of 52 computed tomography-based plans from 13 patients with cervical cancer (FIGO IB2-IIIB) were evaluated for HDR brachytherapy. Prescription was 7 Gy to the ICRU point A for four weekly fractions. Gastrointestinal and genitourinary toxicities were evaluated. Clinical target volume (CTV) and organs at risk were delineated on CT scans. Bladder, rectum, and sigmoid mean doses and D2cc were calculated. Treatment time and irradiated tissue volume were compared. Percent of CTV receiving 100% (CTV100%) of the prescribed dose as well as the percent of the prescription dose covering 90% of the CTV (D90) were evaluated. RESULTS:Gastrointestinal and genitourinary toxicities were not different between TO and TR applicators. No significant differences in the dose to the right and left point A, or the left point B were observed. TO delivered a higher dose to right point B. Organs at risk doses were similar between the two applicators, except mean rectal dose was lower for TO applicator. Overall, TO treats a larger tissue volume than TR. Mean treatment time was shorter for TR. Tumor coverage (D90 and CTV100%) was equivalent between TO and TR applicators. CONCLUSION:Although TO treats a larger tissue volume than TR, short-term toxicities and tumor coverage are similar. Long-term clinical outcomes will be elucidated with longer follow up period.
journal_name
J Contemp Brachytherapyjournal_title
Journal of contemporary brachytherapyauthors
Ma JK,Mourad WF,Allbright R,Packianathan S,Harrell LM,Chinchar E,Nguyen A,Vijayakumar Sdoi
10.5114/jcb.2015.51853subject
Has Abstractpub_date
2015-06-01 00:00:00pages
218-23issue
3eissn
1689-832Xissn
2081-2841pii
25186journal_volume
7pub_type
杂志文章abstract:Purpose:The aim of this study was to propose an index for evaluating dosimetric impact of inter-observer target delineation variability in brachytherapy. Material and methods:The coverage with dosimetric concordance index (CDCI) is expressed as CDCIcommon and CDCIpair. The CDCIcommon is the mean coverage of target vol...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2020.94309
更新日期:2020-04-01 00:00:00
abstract::Paediatric malignancies are relatively rare, with an annual frequency of 13-14 in 100 000 children up to 15 years, and account for less than 1% of all cancer in developed countries. Paediatric tumours are generally managed with a multi-modality treatment programme that includes surgery, chemotherapy, and external beam...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章,评审
doi:10.5114/jcb.2010.14407
更新日期:2010-06-01 00:00:00
abstract:PURPOSE:The incidence of non-melanoma skin cancer (NMSC) has been increasing over the past 30 years. There are different treatment options and surgical excision is the most frequent treatment due to its low rates of recurrence. Radiotherapy is an effective alternative of surgery, and brachytherapy (BT) might be a bette...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章,评审
doi:10.5114/jcb.2016.64112
更新日期:2016-12-01 00:00:00
abstract:PURPOSE:To explore patterns of time to failure in men receiving high doses of permanent seed brachytherapy with or without external beam radiation therapy as a function of risk status. MATERIAL AND METHODS:Two thousand two hundred and thirty four patients were treated with prostate brachytherapy with median follow up ...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2013.39210
更新日期:2013-12-01 00:00:00
abstract:PURPOSE:Groupe Européen de Curiethérapie (GEC) and European Society for Radiotherapy & Oncology (ESTRO) has proposed a rectal dose constraint of the most exposed 2-cc volume (D2cc of ≤ 75 Gy EQD2α/β = 3) during external-beam plus high-dose-rate brachytherapy (HDR-BT) in localized prostate cancer patients. This study ai...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2016.61738
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:To report the treatment effect of interstitial brachytherapy for abdominal wall metastases of ovarian cancer. MATERIAL AND METHODS:The patient is a 44-year-old female with a diagnosis of stage IA ovarian cancer. After surgery and two cycles of chemotherapy with paclitaxel and carboplatin, the patient noticed d...
journal_title:Journal of contemporary brachytherapy
pub_type:
doi:10.5114/jcb.2015.48574
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:In the study we present the initial results of palliative treatment using combined methods of HDR-BT and stent insertion in patients with advanced esophagus cancer. MATERIAL AND METHODS:Fifty patients were treated in the Great Poland Cancer Center using HDR-BT between June 2001 and December 2005 and they were ...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:
更新日期:2009-03-01 00:00:00
abstract:Purpose:To present a small series of cases, in which single-fraction image-guided high-dose-rate (HDR) brachytherapy was provided as palliative treatment for inoperable head and neck cancer cases. Material and methods:We used this technique to treat 3 patients with symptomatic head and neck cancer (tongue cancer, ging...
journal_title:Journal of contemporary brachytherapy
pub_type:
doi:10.5114/jcb.2020.96870
更新日期:2020-06-01 00:00:00
abstract:PURPOSE:Intracavitary brachytherapy necessitates the insertion of a tandem applicator through the cervical os into the uterine cavity. Blind insertion of the tandem may result in suboptimal tandem placement. This decreases the control of the tumor locally and may result in uterine perforation. Although routine real tim...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2014.55115
更新日期:2015-10-01 00:00:00
abstract:Purpose:There is limited data to support the use of hypofractionated external beam radiation (HypoF) in combination with high-dose-rate brachytherapy (HDR). We report our quality of life (QOL) outcomes when treating intermediate and high-risk prostate cancer patients with external beam radiation (EBRT) plus HDR. Mater...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2018.76980
更新日期:2018-06-01 00:00:00
abstract:Purpose:A feasibility study of 3D volume-based interstitial brachytherapy using thermoplastic polyether ether ketone (PEEK) catheters in advanced cervical cancer MR-based brachytherapy, when MR-compatible applicators are not available. Material and methods:Five cervical cancer patients received EBRT dose of 50 Gy in 2...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2019.86975
更新日期:2019-08-01 00:00:00
abstract:PURPOSE:Low energy sources are routinely used in prostate brachytherapy. (125)I is one of the most commonly used sources. Low energy (131)Cs source was introduced recently as a brachytherapy source. The aim of this study is to compare dose distributions of (125)I, (103)Pd, and (131)Cs sources in interstitial brachyther...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2016.57708
更新日期:2016-02-01 00:00:00
abstract:PURPOSE:Adjuvant brachytherapy (AB) with immediate (IR) and staged reconstruction (SR) are distinct treatment modalities available for patients with recurrent soft tissue sarcoma (STS). Although SR may offer local control and toxicity benefit, it requires additional upfront procedures, and there is no evidence that it ...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2017.65641
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:While there are several reports of prostate multisector dosimetry data obtained from CT or MRI scans performed at intervals ranging from 14-70 days after prostate brachytherapy (PB), there are no reports on multisector dosimetry performed in the immediate post-implant period. This study was undertaken to determ...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2014.42023
更新日期:2014-03-01 00:00:00
abstract:PURPOSE:Dose coverage is crucial for successful treatment in mono-brachytherapy. Since few and very high dose fractions are used, there is an important balance between dwell positioning outside the clinical target volume (CTV) and possible damage on adjacent normal tissue. The purpose of this study was to evaluate the ...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2014.45586
更新日期:2014-10-01 00:00:00
abstract::Cervical cancer (CC) is a neoplasm with great potential for prevention, but it is still an important public health problem in most developing countries. No significant difference is found in the literature between intracavitary high-dose-rate (HDR) and low-dose-rate (LDR) brachytherapy, when considering overall, disea...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章,评审
doi:10.5114/jcb.2018.81027
更新日期:2018-12-01 00:00:00
abstract::In order to improve oncologic outcomes in radiotherapy treatments of patients with unresectable pelvic sidewall recurrences of uterine cervical cancer, we combined high-dose-rate interstitial brachytherapy (HDR-ISBT) with newly tested hypoxic radiosensitizer Kochi oxydol-radiation therapy for unresectable carcinomas (...
journal_title:Journal of contemporary brachytherapy
pub_type:
doi:10.5114/jcb.2020.101695
更新日期:2020-12-01 00:00:00
abstract:PURPOSE:Three different techniques of low-dose-rate seed implantation for prostate cancer have been used since its use started in our hospital. The purpose of this study was to compare the results of the three different techniques. MATERIAL AND METHODS:The data of 305 prostate cancer patients who underwent low-dose-ra...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2015.48603
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:Three-dimensional (3D) printing technology allows physicians to rapidly create customized devices for patients. We report our initial clinical experience using this technology to create custom applicators for vaginal brachytherapy. MATERIAL AND METHODS:Three brachytherapy patients with unique clinical needs we...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2016.60679
更新日期:2016-06-01 00:00:00
abstract:Purpose:This research aims to evaluate the effectiveness and safety of a robot-assisted 3D personalized template in 125I seed brachytherapy of thoracoabdominal tumors. Material and methods:Forty-three patients with different tumors were involved in this research between 2013 and 2015. They were all eligible to 125I se...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2018.77957
更新日期:2018-08-01 00:00:00
abstract:Purpose:To quantify the reduction of relative displacement between the implanted intracavitary applicator and the patient bony anatomy, due to the use of a hover transport system during the patient transports between the imaging table and the treatment table. Material and methods:The displacement of the applicator ins...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2018.73755
更新日期:2018-02-01 00:00:00
abstract:PURPOSE:To evaluate the treatment outcomes with high-dose-rate (HDR) interstitial brachytherapy (HDR-BRT) in head and neck cancers (HNC). MATERIAL AND METHODS:Fifty-eight patients with HNC as per American Joint Committee on Cancer (AJCC) TNM staging criteria were analyzed retrospectively between 2008 and 2015. Forty-t...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2017.67147
更新日期:2017-04-01 00:00:00
abstract:PURPOSE:Standard treatment plan libraries are often used to ensure a quick turn-around time for vaginal cylinder treatments. Recently there is increasing interest in transitioning from conventional 2D radiograph based brachytherapy to 3D image based brachytherapy, which has resulted in a substantial increase in treatme...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2012.29365
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To outline the evolution of computerized brachytherapy treatment planning in the United States through a review of technological developments and clinical practice refinements. MATERIAL AND METHODS:A literature review was performed and interviews were conducted with six participants in the development of compu...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章,评审
doi:10.5114/jcb.2014.43131
更新日期:2014-06-01 00:00:00
abstract:Purpose:The aim of this study was to compare short-term oncologic outcomes and toxicity of focal or partial low-dose-rate brachytherapy (focal/partial LDR-BT) with whole gland low-dose-rate brachytherapy (whole LDR-BT) in localized prostate cancer patients. Material and methods:Medical records of eligible patients who...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2020.100374
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:To report the treatment effect of image-guided high-dose-rate (HDR) interstitial brachytherapy for refractory recurrence of papillary thyroid cancer (PTC). CASE REPORT:This 66-year-old female presented with recurrence 5 years after thyroidectomy for PTC. Despite external irradiation and radioactive (131)I, the...
journal_title:Journal of contemporary brachytherapy
pub_type:
doi:10.5114/jcb.2016.59127
更新日期:2016-04-01 00:00:00
abstract:Purpose:Permanent seed implant cesium-131 (131Cs) brachytherapy provides highly localized radiation for patients with recurrent head and neck cancer (HNC), who may be ineligible for external beam radiation therapy due to a high-risk of toxicity. As carotid blowout is a concern in the setting of re-irradiation, a dose t...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2019.86298
更新日期:2019-06-01 00:00:00
abstract::The aim of this study is to report the use of ruthenium brachytherapy as an adjunctive treatment in the management of an intraocular extension of the conjunctival squamous cell carcinoma (SCC). In 2013, a 73-year-old man presented with a tumor blocking the angle and infiltrating corneal endothelium. The patient was tr...
journal_title:Journal of contemporary brachytherapy
pub_type:
doi:10.5114/jcb.2018.75603
更新日期:2018-04-01 00:00:00
abstract:Purpose:To evaluate dose-volume relationships of target volume and critical structures in computed tomography (CT) image-based brachytherapy for head and neck cancer. Material and methods:Thirty-seven patients with mobile tongue, floor of mouth, and base of tongue cancer treated with brachytherapy (post-operative alon...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2017.72581
更新日期:2017-12-01 00:00:00
abstract:PURPOSE:Intracavitary brachytherapy (ICB) is a widely used technique in the treatment of cervical cancer. In our Institute, we use different reconstructive methods in the conventional planning procedure. The main aim of this study was to compare these methods using critical organ doses obtained in various treatment pla...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2010.19498
更新日期:2010-12-01 00:00:00