High-dose-rate interstitial brachytherapy in head and neck cancer: do we need a look back into a forgotten art - a single institute experience.

Abstract:

PURPOSE:To evaluate the treatment outcomes with high-dose-rate (HDR) interstitial brachytherapy (HDR-BRT) in head and neck cancers (HNC). MATERIAL AND METHODS:Fifty-eight patients with HNC as per American Joint Committee on Cancer (AJCC) TNM staging criteria were analyzed retrospectively between 2008 and 2015. Forty-two patients received external beam radiotherapy (EBRT) with HDR-BRT and 16 patients received BRT alone. The survival was calculated with respect to median biological equivalent doses (BED) and median 2 Gy equivalent dose (EQD2), keeping α/β = 10 for tumor. Loco-regional control and disease free survival was assessed. RESULTS:The median follow-up period was 25 months (2-84 months). The disease-free survival (DFS) probability at year 1 was 82.7%, and 68% at year 7. The overall survival probability was 91.3% at year 1 and 85.8% at year 7. The local control rate was 70%. The rate of recurrence was 30%. Distant metastasis rate was 17.2%. The median BED and EQD2, respectively, were 86.78 Gy and 71.6 Gy. The DFS was 74.1% and 75.9% in patients receiving a dose more than median BED and EQD2, respectively, and was 64.8% and 61.5% for less than the median dose. CONCLUSIONS:The overall outcome was good with implementation of HDR-BRT used alone or as boost, and shows DFS as better when the dose received is more than the median BED and median EQD2. The role of HDR-BRT in HNC is a proven, effective, and safe treatment method with excellent long term outcome as seen in this study, which reflects the need for reviving the forgotten art and science of interstitial brachytherapy in HNC.

authors

Bhalavat R,Chandra M,Pareek V,Nellore L,George K,Nandakumar P,Bauskar P

doi

10.5114/jcb.2017.67147

subject

Has Abstract

pub_date

2017-04-01 00:00:00

pages

124-131

issue

2

eissn

1689-832X

issn

2081-2841

pii

29813

journal_volume

9

pub_type

杂志文章
  • Feasibility and early toxicity of focal or partial brachytherapy in prostate cancer patients.

    abstract:Purpose:The aim of this study was to compare short-term oncologic outcomes and toxicity of focal or partial low-dose-rate brachytherapy (focal/partial LDR-BT) with whole gland low-dose-rate brachytherapy (whole LDR-BT) in localized prostate cancer patients. Material and methods:Medical records of eligible patients who...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2020.100374

    authors: Kim TH,Kim JN,Yu YD,Lee SR,Hong YK,Shin HS,Park DS

    更新日期:2020-10-01 00:00:00

  • A case report of ultrasound-guided interstitial brachytherapy for abdominal wall metastases of ovarian cancer.

    abstract:PURPOSE:To report the treatment effect of interstitial brachytherapy for abdominal wall metastases of ovarian cancer. MATERIAL AND METHODS:The patient is a 44-year-old female with a diagnosis of stage IA ovarian cancer. After surgery and two cycles of chemotherapy with paclitaxel and carboplatin, the patient noticed d...

    journal_title:Journal of contemporary brachytherapy

    pub_type:

    doi:10.5114/jcb.2015.48574

    authors: Shi D,Wu N,Zhao H,He M,Han D,Cheng G

    更新日期:2015-02-01 00:00:00

  • INTERACTS (INTErventional Radiotherapy ACtive Teaching School) consensus conference on sarcoma interventional radiotherapy (brachytherapy) endorsed by AIRO (Italian Association of Radiotherapy and Clinical Oncology).

    abstract:Purpose:To report the results of INTERACTS (INTErventional Radiotherapy ACtive Teaching School) consensus conference on sarcoma interventional radiotherapy (brachytherapy). Material and methods:An international board of multidisciplinary experts was invited to a consensus conference on the state-of-the-art of sarcoma ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2020.98120

    authors: Tagliaferri L,Vavassori A,Lancellotta V,Sanctis V,Vidali C,Casà C,Aristei C,Genovesi D,Jereczek-Fossa BA,Morganti AG,Kovács G,Guinot JL,Rembielak A,Greto D,Gambacorta MA,Valentini V,Donato V,Corvò R,Magrini SM,Livi

    更新日期:2020-08-01 00:00:00

  • Single versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning.

    abstract:PURPOSE:To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. MATERIAL AND METHODS:We randomly selected...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2014.47816

    authors: Bahadur YA,Constantinescu C,Hassouna AH,Eltaher MM,Ghassal NM,Awad NA

    更新日期:2015-01-01 00:00:00

  • The role of interstitial brachytherapy in the management of primary radiation therapy for uterine cervical cancer.

    abstract:PURPOSE:The aim of this study was to report the clinical results of uterine cervical cancer patients treated by primary radiation therapy including brachytherapy, and investigate the role of interstitial brachytherapy (ISBT). MATERIAL AND METHODS:All consecutive uterine cervical cancer patients who were treated by pri...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2016.62938

    authors: Murakami N,Kobayashi K,Kato T,Nakamura S,Wakita A,Okamoto H,Shima S,Tsuchida K,Kashihara T,Harada K,Takahashi K,Umezawa R,Inaba K,Ito Y,Igaki H,Itami J

    更新日期:2016-10-01 00:00:00

  • Artificial intelligence (AI) and interventional radiotherapy (brachytherapy): state of art and future perspectives.

    abstract:Purpose:Artificial intelligence (AI) plays a central role in building decision supporting systems (DSS), and its application in healthcare is rapidly increasing. The aim of this study was to define the role of AI in healthcare, with main focus on radiation oncology (RO) and interventional radiotherapy (IRT, brachythera...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2020.100384

    authors: Fionda B,Boldrini L,D'Aviero A,Lancellotta V,Gambacorta MA,Kovács G,Patarnello S,Valentini V,Tagliaferri L

    更新日期:2020-10-01 00:00:00

  • Inter-institutional comparison of treatment practice for cervical cancer with special emphasis on brachytherapy.

    abstract:Purpose:To compare the cervical cancer treatment outcome and toxicities between two different institutions. Material and methods:We analysed the clinical outcome of cervical cancer patients treated at two different centres from January 2015 to December 2016. Centre A treated 72 patients by external beam radiotherapy (...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.88582

    authors: Ravindran E,Kumar M,Gururajachar JM,Thangaraj R

    更新日期:2019-10-01 00:00:00

  • Comparison of three different techniques of low-dose-rate seed implantation for prostate cancer.

    abstract:PURPOSE:Three different techniques of low-dose-rate seed implantation for prostate cancer have been used since its use started in our hospital. The purpose of this study was to compare the results of the three different techniques. MATERIAL AND METHODS:The data of 305 prostate cancer patients who underwent low-dose-ra...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2015.48603

    authors: Ishiyama H,Satoh T,Sekiguchi A,Tabata K,Komori S,Tsumura H,Kawakami S,Soda I,Takenaka K,Iwamura M,Hayakawa K

    更新日期:2015-02-01 00:00:00

  • A comparison of dose distribution from Manchester-style and Fletcher-style intracavitary brachytherapy applicator systems in cervical cancer.

    abstract:PURPOSE:During intracavitary brachytherapy (ICBT) for cervical cancer, the choice of applicator system remains rather arbitrary. However, as the applicator geometry may play an important role in dose distribution, thereby improving the therapeutic ratio, this study was conducted to compare the Manchester-style and Flet...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2012.32555

    authors: Basu B,Basu S,Chakraborti B,Ghorai S,Gupta P,Ghosh S,Ghosh K,Jayanti J

    更新日期:2012-12-01 00:00:00

  • High-dose-rate brachytherapy as monotherapy for localized prostate cancer using three different doses - 14 years of single-centre experience.

    abstract:Purpose:To evaluate clinical outcomes in patients with localized prostate cancer (LPC) treated with 3D conformal high-dose-rate (HDR) brachytherapy (BT) as monotherapy. Material and methods:From March 2004 to November 2017, 277 men with LPC underwent 3D conformal HDR-BT as monotherapy, with a temporary implant. The do...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2020.101685

    authors: Soatti CP,Delishaj D,D'Amico R,Frigerio C,Fumagalli IC,Bonsignore F,Sangalli G,Declich F,Arcangeli S,Ardizzoia A,Colombo A

    更新日期:2020-12-01 00:00:00

  • Dose-volume analysis of target volume and critical structures in computed tomography image-based multicatheter high-dose-rate interstitial brachytherapy for head and neck cancer.

    abstract:Purpose:To evaluate dose-volume relationships of target volume and critical structures in computed tomography (CT) image-based brachytherapy for head and neck cancer. Material and methods:Thirty-seven patients with mobile tongue, floor of mouth, and base of tongue cancer treated with brachytherapy (post-operative alon...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.72581

    authors: Akiyama H,Major T,Polgár C,Takácsi-Nagy Z

    更新日期:2017-12-01 00:00:00

  • Comparison of post-implant dosimetrics between intraoperatively built custom-linked seeds and loose seeds by sector analysis at 24 hours and 1 month for localized prostate cancer.

    abstract:Purpose:To compare post-implant dosimetrics between intraoperatively built custom-linked (IBCL) seeds and loose seeds (LS) at 24 hours and 1 month by sector analysis, and to evaluate the effect of IBCL seeds with regard to change in dosimetric parameters, in patients with prostate cancer treated with brachytherapy. Ma...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2020.98110

    authors: Okazaki E,Kuratsukuri K,Nishikawa T,Tanaka T,Sakagami M,Shibuya K

    更新日期:2020-08-01 00:00:00

  • Staged reconstruction brachytherapy has lower overall cost in recurrent soft-tissue sarcoma.

    abstract:PURPOSE:Adjuvant brachytherapy (AB) with immediate (IR) and staged reconstruction (SR) are distinct treatment modalities available for patients with recurrent soft tissue sarcoma (STS). Although SR may offer local control and toxicity benefit, it requires additional upfront procedures, and there is no evidence that it ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.65641

    authors: Naghavi AO,Gonzalez RJ,Scott JG,Kim Y,Abuodeh YA,Strom TJ,Echevarria M,Mullinax JE,Ahmed KA,Harrison LB,Fernandez DC

    更新日期:2017-02-01 00:00:00

  • Routine use of ultrasound guided tandem placement in intracavitary brachytherapy for the treatment of cervical cancer - a South Indian institutional experience.

    abstract:PURPOSE:Intracavitary brachytherapy necessitates the insertion of a tandem applicator through the cervical os into the uterine cavity. Blind insertion of the tandem may result in suboptimal tandem placement. This decreases the control of the tumor locally and may result in uterine perforation. Although routine real tim...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2014.55115

    authors: Rao PB,Ghosh S

    更新日期:2015-10-01 00:00:00

  • The use of nomograms in LDR-HDR prostate brachytherapy.

    abstract:PURPOSE:The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and t...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2011.24817

    authors: Pujades MC,Camacho C,Perez-Calatayud J,Richart J,Gimeno J,Lliso F,Carmona V,Ballester F,Crispín V,Rodríguez S,Tormo A

    更新日期:2011-09-01 00:00:00

  • A comparison study on various low energy sources in interstitial prostate brachytherapy.

    abstract:PURPOSE:Low energy sources are routinely used in prostate brachytherapy. (125)I is one of the most commonly used sources. Low energy (131)Cs source was introduced recently as a brachytherapy source. The aim of this study is to compare dose distributions of (125)I, (103)Pd, and (131)Cs sources in interstitial brachyther...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2016.57708

    authors: Bakhshabadi M,Ghorbani M,Khosroabadi M,Knaup C,Meigooni AS

    更新日期:2016-02-01 00:00:00

  • Interstitial brachytherapy in soft tissue sarcoma: a 5 years institutional experience with Cobalt 60-based high-dose-rate brachytherapy system.

    abstract:Purpose:Soft tissue sarcoma (STS) is rare but aggressive neoplasm. Interstitial brachytherapy (ISBT) alone or combined with external beam radiotherapy (EBRT) as post-operative treatment improves loco-regional (LRC) and distant control. Material and methods:Out of twenty-nine non-metastatic STS (lower limb 64%) patient...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2018.78994

    authors: Manir KS,Basu A,Choudhury KB,Basu S,Ghosh K,Gangopadhyay S

    更新日期:2018-10-01 00:00:00

  • Non-melanoma skin cancer treated with high-dose-rate brachytherapy: a review of literature.

    abstract:PURPOSE:The incidence of non-melanoma skin cancer (NMSC) has been increasing over the past 30 years. There are different treatment options and surgical excision is the most frequent treatment due to its low rates of recurrence. Radiotherapy is an effective alternative of surgery, and brachytherapy (BT) might be a bette...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2016.64112

    authors: Delishaj D,Rembielak A,Manfredi B,Ursino S,Pasqualetti F,Laliscia C,Orlandi F,Morganti R,Fabrini MG,Paiar F

    更新日期:2016-12-01 00:00:00

  • Multisector dosimetry in the immediate post-implant period: significant under dosage of the prostate base.

    abstract:PURPOSE:While there are several reports of prostate multisector dosimetry data obtained from CT or MRI scans performed at intervals ranging from 14-70 days after prostate brachytherapy (PB), there are no reports on multisector dosimetry performed in the immediate post-implant period. This study was undertaken to determ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2014.42023

    authors: Kirschner AN,Sathiaseelan V,Zhang Y,David J,Kalapurakal JA

    更新日期:2014-03-01 00:00:00

  • High-dose-rate interstitial brachytherapy for liver metastases: first study from India.

    abstract:PURPOSE:To study the safety and efficacy of high-dose-rate interstitial brachytherapy (HDRIBT) in patients with liver metastases (LM). MATERIAL AND METHODS:Between 2009 and 2011, 10 patients with 12 metastatic lesions in the liver were enrolled in this prospective trial. All patients had either refused surgery or foun...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2013.36175

    authors: Sharma DN,Thulkar S,Sharma S,Gandhi AK,Haresh KP,Gupta S,Rath GK,Julka PK

    更新日期:2013-06-01 00:00:00

  • A novel method for vaginal cylinder treatment planning: a seamless transition to 3D brachytherapy.

    abstract:PURPOSE:Standard treatment plan libraries are often used to ensure a quick turn-around time for vaginal cylinder treatments. Recently there is increasing interest in transitioning from conventional 2D radiograph based brachytherapy to 3D image based brachytherapy, which has resulted in a substantial increase in treatme...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2012.29365

    authors: Malhotra HK,Wu V,Wang Z,Patil S

    更新日期:2012-06-01 00:00:00

  • Non-melanoma skin cancer treated with high-dose-rate brachytherapy and Valencia applicator in elderly patients: a retrospective case series.

    abstract:PURPOSE:The incidence of non-melanoma skin cancer (NMSC) has been increasing over the past 30 years. Basal cell carcinoma and squamous cell carcinoma are the two most common subtypes of NMSC. The aim of this study was to estimate tumour control, toxicity, and aesthetic events in elderly patients treated with high-dose-...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2015.55746

    authors: Delishaj D,Laliscia C,Manfredi B,Ursino S,Pasqualetti F,Lombardo E,Perrone F,Morganti R,Paiar F,Fabrini MG

    更新日期:2015-12-01 00:00:00

  • High-dose-rate brachytherapy in treatment of non-melanoma skin cancer of head and neck region: preliminary results of a prospective single institution study.

    abstract:Purpose:Skin cancers are the most common human malignancy with increasing incidence. Currently, surgery is standard of care treatment for non-melanoma skin cancers. However, brachytherapy is a growing modality in the management of skin cancers. Therefore, we aimed to assess the outcome of patients with non-melanoma ski...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2018.75596

    authors: Kalaghchi B,Esmati E,Ghalehtaki R,Gomar M,Jaberi R,Gholami S,Babaloui S,Nabavi M,Sotoudeh S,Khanjani N,Kazemian A,Amouzegar-Hashemi F,Aghili M,Lashkari M

    更新日期:2018-04-01 00:00:00

  • The impact of activating source dwell positions outside the CTV on the dose to treated normal tissue volumes in TRUS guided 3D conformal interstitial HDR brachytherapy of prostate cancer.

    abstract:PURPOSE:Dose coverage is crucial for successful treatment in mono-brachytherapy. Since few and very high dose fractions are used, there is an important balance between dwell positioning outside the clinical target volume (CTV) and possible damage on adjacent normal tissue. The purpose of this study was to evaluate the ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2014.45586

    authors: Karlsson L,Thunberg P,Johansson B,Persliden J

    更新日期:2014-10-01 00:00:00

  • Reduction of applicator displacement in MR/CT-guided cervical cancer HDR brachytherapy by the use of patient hover transport system.

    abstract:Purpose:To quantify the reduction of relative displacement between the implanted intracavitary applicator and the patient bony anatomy, due to the use of a hover transport system during the patient transports between the imaging table and the treatment table. Material and methods:The displacement of the applicator ins...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2018.73755

    authors: Andrew M,Kim Y,Ginader T,Smith BJ,Sun W,Wang D

    更新日期:2018-02-01 00:00:00

  • Pain relief procedures before high-dose-rate brachytherapy for non-surgical treatment of cervix cancer.

    abstract::Cervical cancer (CC) is a neoplasm with great potential for prevention, but it is still an important public health problem in most developing countries. No significant difference is found in the literature between intracavitary high-dose-rate (HDR) and low-dose-rate (LDR) brachytherapy, when considering overall, disea...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2018.81027

    authors: Pellizzon ACA

    更新日期:2018-12-01 00:00:00

  • Evaluation of interpolation methods for TG-43 dosimetric parameters based on comparison with Monte Carlo data for high-energy brachytherapy sources.

    abstract:PURPOSE:The aim of this work was to determine dose distributions for high-energy brachytherapy sources at spatial locations not included in the radial dose function gL(r) and 2D anisotropy function F(r,θ) table entries for radial distance r and polar angle θ. The objectives of this study are as follows: 1) to evaluate ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2010.13715

    authors: Pujades-Claumarchirant MC,Granero D,Perez-Calatayud J,Ballester F,Melhus C,Rivard M

    更新日期:2010-03-01 00:00:00

  • Does supplemental external beam radiation therapy impact urinary, bowel, and erectile function following permanent prostate brachytherapy?: results of two prospective randomized trials.

    abstract:Purpose:To evaluate the impact of supplemental external beam radiation therapy (EBRT) prior to permanent prostate brachytherapy on long term urinary, bowel, and erectile function. Material and methods:Patient administered urinary, bowel, and erectile quality of life (QoL) instrument were obtained prior to treatment an...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.70763

    authors: Merrick GS,Tennant A,Wallner KE,Galbreath R,Butler WM,Fiano R,Adamovich E

    更新日期:2017-10-01 00:00:00

  • Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate.

    abstract:PURPOSE:This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostate brachytherapy, biopsy and other interventional procedures. Furthermore, an evaluation ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2011.26472

    authors: Diamantopoulos S,Milickovic N,Butt S,Katsilieri Z,Kefala V,Zogal P,Sakas G,Baltas D

    更新日期:2011-12-01 00:00:00

  • Carotid dosimetry after re-irradiation with 131Cs permanent implant brachytherapy in recurrent, resected head and neck cancer.

    abstract:Purpose:Permanent seed implant cesium-131 (131Cs) brachytherapy provides highly localized radiation for patients with recurrent head and neck cancer (HNC), who may be ineligible for external beam radiation therapy due to a high-risk of toxicity. As carotid blowout is a concern in the setting of re-irradiation, a dose t...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.86298

    authors: Walsh A,Hubley E,Doyle L,Cognetti D,Curry J,Bar-Ad V,Luginbuhl A

    更新日期:2019-06-01 00:00:00