Abstract:
PURPOSE:Intracavitary brachytherapy (ICB) is a widely used technique in the treatment of cervical cancer. In our Institute, we use different reconstructive methods in the conventional planning procedure. The main aim of this study was to compare these methods using critical organ doses obtained in various treatment plans. There is a small difference in the recommendations in selecting bladder dose point between ICRU (International Commission on Radiation Units & Measurements) -38 and ABS (American Brachytherapy Society). The second objective of the study was to find the difference in bladder dose using both recommendations. MATERIAL AND METHODS:We have selected two methods: variable angle method (M1) and orthogonal method (M2). Two orthogonal sets of radiographs were taken into consideration using conventional simulator. All four radiographs were used in M1 and only two radiographs were used in M2. Bladder and rectum doses were calculated using ICRU-38 recommendations. For maximum bladder dose reference point as per the ABS recommendation, 4 to 5 reference points were marked on Foley's balloon. RESULTS:64% of plans were showing more bladder dose and 50% of plans presented more rectum dose in M1 compared to M2. Many of the plans reviled maximum bladder dose point, other than ICRU-38 bladder point in both methods. Variation was exceeded in 5% of considerable number of plans. CONCLUSIONS:We observed a difference in critical organ dose between two studied methods. There is an advantage of using variable angle reconstruction method in identifying the catheters. It is useful to follow ABS recommendation to find maximum bladder dose.
journal_name
J Contemp Brachytherapyjournal_title
Journal of contemporary brachytherapyauthors
Sresty NM,Ramanjappa T,Rao CR,Raju AK,Muralidhar KRdoi
10.5114/jcb.2010.19498subject
Has Abstractpub_date
2010-12-01 00:00:00pages
171-175issue
4eissn
1689-832Xissn
2081-2841pii
16096journal_volume
2pub_type
杂志文章abstract:Purpose:To compare post-implant dosimetrics between intraoperatively built custom-linked (IBCL) seeds and loose seeds (LS) at 24 hours and 1 month by sector analysis, and to evaluate the effect of IBCL seeds with regard to change in dosimetric parameters, in patients with prostate cancer treated with brachytherapy. Ma...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2020.98110
更新日期:2020-08-01 00:00:00
abstract::A 33-year-old premenopausal multiparous woman with the history of septate uterus was referred to the hospital with menorrhagia and inter-menstrual bleeding occurring for the last 6 months. Work-up revealed a stage IIB cervical cancer. The patient underwent curative chemo/radiotherapy. The patient's septate uterus pres...
journal_title:Journal of contemporary brachytherapy
pub_type:
doi:10.5114/jcb.2017.70996
更新日期:2017-10-01 00:00:00
abstract:Purpose:Artificial intelligence (AI) plays a central role in building decision supporting systems (DSS), and its application in healthcare is rapidly increasing. The aim of this study was to define the role of AI in healthcare, with main focus on radiation oncology (RO) and interventional radiotherapy (IRT, brachythera...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章,评审
doi:10.5114/jcb.2020.100384
更新日期:2020-10-01 00:00:00
abstract:Purpose:To report the results of INTERACTS (INTErventional Radiotherapy ACtive Teaching School) consensus conference on sarcoma interventional radiotherapy (brachytherapy). Material and methods:An international board of multidisciplinary experts was invited to a consensus conference on the state-of-the-art of sarcoma ...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章,评审
doi:10.5114/jcb.2020.98120
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:Intracavitary brachytherapy necessitates the insertion of a tandem applicator through the cervical os into the uterine cavity. Blind insertion of the tandem may result in suboptimal tandem placement. This decreases the control of the tumor locally and may result in uterine perforation. Although routine real tim...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2014.55115
更新日期:2015-10-01 00:00:00
abstract:Purpose:To compare the cervical cancer treatment outcome and toxicities between two different institutions. Material and methods:We analysed the clinical outcome of cervical cancer patients treated at two different centres from January 2015 to December 2016. Centre A treated 72 patients by external beam radiotherapy (...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2019.88582
更新日期:2019-10-01 00:00:00
abstract:PURPOSE:During intracavitary brachytherapy (ICBT) for cervical cancer, the choice of applicator system remains rather arbitrary. However, as the applicator geometry may play an important role in dose distribution, thereby improving the therapeutic ratio, this study was conducted to compare the Manchester-style and Flet...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2012.32555
更新日期:2012-12-01 00:00:00
abstract:PURPOSE:Three-dimensional (3D) printing technology allows physicians to rapidly create customized devices for patients. We report our initial clinical experience using this technology to create custom applicators for vaginal brachytherapy. MATERIAL AND METHODS:Three brachytherapy patients with unique clinical needs we...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2016.60679
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:Groupe Européen de Curiethérapie (GEC) and European Society for Radiotherapy & Oncology (ESTRO) has proposed a rectal dose constraint of the most exposed 2-cc volume (D2cc of ≤ 75 Gy EQD2α/β = 3) during external-beam plus high-dose-rate brachytherapy (HDR-BT) in localized prostate cancer patients. This study ai...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2016.61738
更新日期:2016-08-01 00:00:00
abstract:Purpose:To quantify the reduction of relative displacement between the implanted intracavitary applicator and the patient bony anatomy, due to the use of a hover transport system during the patient transports between the imaging table and the treatment table. Material and methods:The displacement of the applicator ins...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2018.73755
更新日期:2018-02-01 00:00:00
abstract:PURPOSE:The standard primary treatment for soft tissue sarcoma (STS) is a wide surgical resection, preceded or followed by radiotherapy. Purpose of this retrospective study was to assess the efficacy of perioperative brachytherapy (BRT) plus postoperative external beam radiation therapy (EBRT) in patients with intermed...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2017.68215
更新日期:2017-06-01 00:00:00
abstract:Purpose:Skin cancers are the most common human malignancy with increasing incidence. Currently, surgery is standard of care treatment for non-melanoma skin cancers. However, brachytherapy is a growing modality in the management of skin cancers. Therefore, we aimed to assess the outcome of patients with non-melanoma ski...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2018.75596
更新日期:2018-04-01 00:00:00
abstract:Purpose:Cervical cancer is the most common gynecological cancer in India. Uniform protocol-based treatment is important for achieving optimal outcomes. We undertook a survey to investigate patterns of care with special regard to patterns of care in cervical cancer brachytherapy in India. Material and methods:A 17-ques...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2019.90448
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:To report the treatment effect of image-guided high-dose-rate (HDR) interstitial brachytherapy for refractory recurrence of papillary thyroid cancer (PTC). CASE REPORT:This 66-year-old female presented with recurrence 5 years after thyroidectomy for PTC. Despite external irradiation and radioactive (131)I, the...
journal_title:Journal of contemporary brachytherapy
pub_type:
doi:10.5114/jcb.2016.59127
更新日期:2016-04-01 00:00:00
abstract:PURPOSE:The aim of this study was to report the clinical results of uterine cervical cancer patients treated by primary radiation therapy including brachytherapy, and investigate the role of interstitial brachytherapy (ISBT). MATERIAL AND METHODS:All consecutive uterine cervical cancer patients who were treated by pri...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2016.62938
更新日期:2016-10-01 00:00:00
abstract:Purpose:To investigate the differences in prostate-specific antigen (PSA) bounce (PB) after high-dose-rate (HDR-BT) or low-dose-rate (LDR-BT) brachytherapy alone in prostate cancer patients. Materials and methods:Ninety-four patients with localized prostate cancer (T1-T2cN0), age ranged 50-81 years, were treated with ...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2018.73786
更新日期:2018-02-01 00:00:00
abstract:PURPOSE:A report of preliminary results and toxicity profiles using image-guided brachytherapy (IGBT) combined with whole pelvic intensity-modulated radiation therapy (WP-IMRT) for locally advanced cervical cancer. MATERIAL AND METHODS:Fifteen patients with locally advanced cervical cancer were enrolled into the study...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2013.34338
更新日期:2013-03-01 00:00:00
abstract:PURPOSE:To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. MATERIAL AND METHODS:We randomly selected...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2014.47816
更新日期:2015-01-01 00:00:00
abstract:PURPOSE:This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostate brachytherapy, biopsy and other interventional procedures. Furthermore, an evaluation ...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2011.26472
更新日期:2011-12-01 00:00:00
abstract:PURPOSE:To report on preliminary results of a prospective study on MRI-assisted cervix cancer brachytherapy pre-planning. MATERIAL AND METHODS:In six locally advanced cervix cancer patients, five days before the first brachytherapy fraction, tandem & ring applicator was inserted under para-cervical anaesthesia, MRI pe...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:
更新日期:2009-10-01 00:00:00
abstract:Purpose:Inadequate procedural training is of increasing concern in resident training, especially in prostate brachytherapy (PB). Transperineal rectal spacer placement (TRSP) requires many of the same proficiencies as PB. This work describes the assessment of teaching techniques focusing on developing critical competenc...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2019.90984
更新日期:2019-12-01 00:00:00
abstract:Purpose:Soft tissue sarcoma (STS) is rare but aggressive neoplasm. Interstitial brachytherapy (ISBT) alone or combined with external beam radiotherapy (EBRT) as post-operative treatment improves loco-regional (LRC) and distant control. Material and methods:Out of twenty-nine non-metastatic STS (lower limb 64%) patient...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2018.78994
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:To compare the short-term toxicity and dosimetry of tandem and ring (TR), and tandem and ovoid (TO) applicators in treatment of gynecologic malignancy. MATERIAL AND METHODS:Following pelvic external beam radiation therapy (EBRT), a total of 52 computed tomography-based plans from 13 patients with cervical canc...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2015.51853
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:To compare prostate contours on conventional stepping transverse image acquisitions with those on twister-based sagittal image acquisitions. MATERIAL AND METHODS:Twenty prostate cancer patients who were planned to have permanent interstitial prostate brachytherapy were prospectively accrued. A transrectal ultr...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2017.69807
更新日期:2017-08-01 00:00:00
abstract:PURPOSE:To study the safety and efficacy of high-dose-rate interstitial brachytherapy (HDRIBT) in patients with liver metastases (LM). MATERIAL AND METHODS:Between 2009 and 2011, 10 patients with 12 metastatic lesions in the liver were enrolled in this prospective trial. All patients had either refused surgery or foun...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2013.36175
更新日期:2013-06-01 00:00:00
abstract:Purpose:We present a case report of treatment using interstitial and surface high-dose-rate (HDR) brachytherapy for cutaneous squamous cell carcinoma (SCC) involving the interspace of the third and fourth digits. The patient refused two-ray amputation and the lesion was not amenable for external beam radiation therapy ...
journal_title:Journal of contemporary brachytherapy
pub_type:
doi:10.5114/jcb.2020.92408
更新日期:2020-02-01 00:00:00
abstract::High-dose-rate endorectal brachytherapy (HDREBT) is an image guided brachytherapy treatment for patients with rectal cancer. It is based on tumor imaging with magnetic resonance in particular, which is used to choose eligible patients and improve tumor visualization. Treatment planning is performed using 3D CT simulat...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章,评审
doi:10.5114/jcb.2015.51402
更新日期:2015-04-01 00:00:00
abstract:PURPOSE:The aim of this work was to determine dose distributions for high-energy brachytherapy sources at spatial locations not included in the radial dose function gL(r) and 2D anisotropy function F(r,θ) table entries for radial distance r and polar angle θ. The objectives of this study are as follows: 1) to evaluate ...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2010.13715
更新日期:2010-03-01 00:00:00
abstract:Purpose:The aim of this study was to compare short-term oncologic outcomes and toxicity of focal or partial low-dose-rate brachytherapy (focal/partial LDR-BT) with whole gland low-dose-rate brachytherapy (whole LDR-BT) in localized prostate cancer patients. Material and methods:Medical records of eligible patients who...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2020.100374
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:While there are several reports of prostate multisector dosimetry data obtained from CT or MRI scans performed at intervals ranging from 14-70 days after prostate brachytherapy (PB), there are no reports on multisector dosimetry performed in the immediate post-implant period. This study was undertaken to determ...
journal_title:Journal of contemporary brachytherapy
pub_type: 杂志文章
doi:10.5114/jcb.2014.42023
更新日期:2014-03-01 00:00:00