Volume of high-risk intratumoral subregions at multi-parametric MR imaging predicts overall survival and complements molecular analysis of glioblastoma.

Abstract:

OBJECTIVE:To develop and validate a volume-based, quantitative imaging marker by integrating multi-parametric MR images for predicting glioblastoma survival, and to investigate its relationship and synergy with molecular characteristics. METHODS:We retrospectively analysed 108 patients with primary glioblastoma. The discovery cohort consisted of 62 patients from the cancer genome atlas (TCGA). Another 46 patients comprising 30 from TCGA and 16 internally were used for independent validation. Based on integrated analyses of T1-weighted contrast-enhanced (T1-c) and diffusion-weighted MR images, we identified an intratumoral subregion with both high T1-c and low ADC, and accordingly defined a high-risk volume (HRV). We evaluated its prognostic value and biological significance with genomic data. RESULTS:On both discovery and validation cohorts, HRV predicted overall survival (OS) (concordance index: 0.642 and 0.653, P < 0.001 and P = 0.038, respectively). HRV stratified patients within the proneural molecular subtype (log-rank P = 0.040, hazard ratio = 2.787). We observed different OS among patients depending on their MGMT methylation status and HRV (log-rank P = 0.011). Patients with unmethylated MGMT and high HRV had significantly shorter survival (median survival: 9.3 vs. 18.4 months, log-rank P = 0.002). CONCLUSION:Volume of the high-risk intratumoral subregion identified on multi-parametric MRI predicts glioblastoma survival, and may provide complementary value to genomic information. KEY POINTS:• High-risk volume (HRV) defined on multi-parametric MRI predicted GBM survival. • The proneural molecular subtype tended to harbour smaller HRV than other subtypes. • Patients with unmethylated MGMT and high HRV had significantly shorter survival. • HRV complements genomic information in predicting GBM survival.

journal_name

Eur Radiol

journal_title

European radiology

authors

Cui Y,Ren S,Tha KK,Wu J,Shirato H,Li R

doi

10.1007/s00330-017-4751-x

subject

Has Abstract

pub_date

2017-09-01 00:00:00

pages

3583-3592

issue

9

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-017-4751-x

journal_volume

27

pub_type

杂志文章
  • Pitfalls and problems to be solved in the diagnostic CT/MRI Liver Imaging Reporting and Data System (LI-RADS).

    abstract::The 2017 Core of the computed tomography (CT)/magnetic resonance imaging (MRI) Liver Imaging Reporting and Data System (LI-RADS) provides clear definitions and concise explanations of the CT/MRI diagnostic algorithm. Nevertheless, there remain some practical and controversial issues that radiologists should be aware o...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-018-5641-6

    authors: Kim YY,Choi JY,Sirlin CB,An C,Kim MJ

    更新日期:2019-03-01 00:00:00

  • MRI of the rectum: non-neoplastic disease.

    abstract::The rectum has become the most successful area of the gastrointestinal tract to be studied with MRI. Its anatomical location, fixed in the pelvic fat, and its lack of peristalsis, make it an ideal organ to be scanned with MRI. In addition, MRI allows a direct sagittal and coronal display, of key importance to colorect...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050328

    authors: Paley MR,Ros PR

    更新日期:1998-01-01 00:00:00

  • Comparison of a new whole-body continuous-table-movement protocol versus a standard whole-body MR protocol for the assessment of multiple myeloma.

    abstract:OBJECTIVES:To evaluate a whole body (WB) continuous-table-movement (CTM) MR protocol for the assessment of multiple myeloma (MM) in comparison to a step-by-step WB protocol. METHODS:Eighteen patients with MM were examined at 1.5T using a WB CTM protocol (axial T2-w fs BLADE, T1-w GRE sequence) and a step-by-step WB pr...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1865-9

    authors: Weckbach S,Michaely HJ,Stemmer A,Schoenberg SO,Dinter DJ

    更新日期:2010-12-01 00:00:00

  • Breast MRI: EUSOBI recommendations for women's information.

    abstract:UNLABELLED:This paper summarizes information about breast MRI to be provided to women and referring physicians. After listing contraindications, procedure details are described, stressing the need for correct scheduling and not moving during the examination. The structured report including BI-RADS® categories and furth...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-015-3807-z

    authors: Mann RM,Balleyguier C,Baltzer PA,Bick U,Colin C,Cornford E,Evans A,Fallenberg E,Forrai G,Fuchsjäger MH,Gilbert FJ,Helbich TH,Heywang-Köbrunner SH,Camps-Herrero J,Kuhl CK,Martincich L,Pediconi F,Panizza P,Pina LJ,Pij

    更新日期:2015-12-01 00:00:00

  • Detection of left atrial thrombus in patients with mitral stenosis and atrial fibrillation: retrospective comparison of two-phase computed tomography, transoesophageal echocardiography and surgical findings.

    abstract:OBJECTIVE:This retrospective study aims to assess the accuracy of two-phase computed tomography (CT) and transoesophageal echocardiography (TEE) for the detection of left atrial (LA) thrombus in patients with mitral stenosis (MS) and atrial fibrillation (AF), by using intraoperative findings as the reference standard. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2944-5

    authors: Choi BH,Ko SM,Hwang HK,Song MG,Shin JK,Kang WS,Kim TY

    更新日期:2013-11-01 00:00:00

  • Meningeal hemangiopericytoma in childhood.

    abstract::Meningeal hemangiopericytoma (MHP) is extremely rare in childhood. Mean age at diagnosis is between 38 and 43 years. We present an 8-year-old boy with MHP of the middle cranial fossa. Imaging findings were indistinguishable from an aggressive bone tumor such as Ewing's sarcoma. Imaging findings are presented and discu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003309900222

    authors: Huisman TA,Brandner S,Niggli F,Kacl G,Willi UV,Martin E

    更新日期:2000-01-01 00:00:00

  • Value of bone suppression software in chest radiographs for improving image quality and reducing radiation dose.

    abstract:OBJECTIVES:To compare image quality and radiation dose between dual-energy subtraction (DES)-based bone suppression images (D-BSIs) and software-based bone suppression images (S-BSIs). METHODS:Chest radiographs (CXRs) of forty adult patients were obtained with the two X-ray devices, one with DES and one with bone supp...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07596-w

    authors: Hong GS,Do KH,Son AY,Jo KW,Kim KP,Yun J,Lee CW

    更新日期:2021-01-13 00:00:00

  • CT-guided radiofrequency ablation of spinal osteoid osteomas with concomitant perineural and epidural irrigation for neuroprotection.

    abstract::Here we report our experience of a neuroprotective adaptation of the technique of CT-guided radiofrequency (RF) ablation of spinal osteoid osteomas. Over 9 years seven patients underwent eight CT-guided RF treatments for osteoid osteoma. CT-guided RF ablation was performed with general anaesthesia. The lesion was heat...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1404-8

    authors: Klass D,Marshall T,Toms A

    更新日期:2009-09-01 00:00:00

  • 2D and 3D T2-weighted MR sequences for the assessment of neurovascular bundle changes after nerve-sparing radical retropubic prostatectomy with erectile function correlation.

    abstract::The aim of this study was to assess the capability of a 3D isotropic MRI T2-weighted sequence (3D T2 ISO) in the depiction of changes of neurovascular bundles (NVBs) after bilateral nerve-sparing radical retropubic prostatectomy (RRP). Furthermore, our aim was also to introduce a new MRI classification score of the NV...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-008-1102-y

    authors: Panebianco V,Sciarra A,Osimani M,Lisi D,Ciccariello M,Salciccia S,Gentile V,Di Silverio F,Passariello R

    更新日期:2009-01-01 00:00:00

  • Diagnosis of pulmonary embolism with spiral CT as a second procedure following scintigraphy.

    abstract::Our objective was to evaluate, in a routine clinical setting, the role of spiral CT as a second procedure in patients with clinically suspected pulmonary embolism (PE) and abnormal perfusion scan. We prospectively studied the role of spiral CT in 279 patients suspected of PE. All patients started their diagnostic algo...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-002-1709-3

    authors: van Strijen MJ,de Monyé W,Kieft GJ,Pattynama PM,Huisman MV,Smith SJ,Bloem JL

    更新日期:2003-07-01 00:00:00

  • Sub-milliSievert (sub-mSv) CT colonography: a prospective comparison of image quality and polyp conspicuity at reduced-dose versus standard-dose imaging.

    abstract:OBJECTIVE:To prospectively compare reduced-dose (RD) CT colonography (CTC) with standard-dose (SD) imaging using several reconstruction algorithms. METHODS:Following SD supine CTC, 40 patients (mean age, 57.3 years; 17 M/23 F; mean BMI, 27.2) underwent an additional RD supine examination (targeted dose reduction, 70-9...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3603-9

    authors: Lubner MG,Pooler BD,Kitchin DR,Tang J,Li K,Kim DH,Munoz del Rio A,Chen GH,Pickhardt PJ

    更新日期:2015-07-01 00:00:00

  • Development and evaluation of a new gray-scale test pattern to adjust gradients of thoracic CT imaging.

    abstract::The purpose of the present study was to evaluate the usefulness of a new gray-scale test pattern (NGTP) that was developed to easily adjust the gradients of thoracic CT imaging and enable visual consistency. The Society of Motion Picture and Television Engineers (SMPTE) pattern and the NGTP were used for comparison. T...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2315-3

    authors: Yamaguchi M,Fujita H,Uemura M,Asai Y,Wakae H,Ishifuro M

    更新日期:2004-12-01 00:00:00

  • Assessment of an advanced virtual monoenergetic reconstruction technique in cerebral and cervical angiography with third-generation dual-source CT: Feasibility of using low-concentration contrast medium.

    abstract:OBJECTIVES:To investigate the feasibility of low-concentration contrast media (LC-CM) in cerebral and cervical dual-energy CT angiography (DE-CTA) using an advanced monoenergetic (Mono+) reconstruction technique. METHODS:Sixty-five consecutive patients prospectively selected to undergo cerebral and cervical DE-CTA wer...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-018-5407-1

    authors: Zhao L,Li F,Zhang Z,Zhang Z,Jiang Y,Wang X,Gu J,Li D

    更新日期:2018-10-01 00:00:00

  • Giant cell tumors of the tendon sheath may present radiologically as intrinsic osseous lesions.

    abstract::The purpose of this study was to explain radiographic features of giant cell tumors of the tendon sheath (GCTTS), in particular, osseous extension, by correlating imaging findings with histology in order to increase the accuracy of radiological diagnosis. In a series of 200 consecutive osseous (pseudo) tumors of the h...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0320-4

    authors: De Schepper AM,Hogendoorn PC,Bloem JL

    更新日期:2007-02-01 00:00:00

  • Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study.

    abstract::The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5....

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0668-0

    authors: Florie J,van Gelder RE,Schutter MP,van Randen A,Venema HW,de Jager S,van der Hulst VP,Prent A,Bipat S,Bossuyt PM,Baak LC,Stoker J

    更新日期:2007-12-01 00:00:00

  • Upright, weight-bearing, dynamic-kinetic MRI of the spine: initial results.

    abstract::The potential relative beneficial aspects of upright, weight-bearing (pMRI), dynamic-kinetic (kMRI) spinal imaging over that of recumbent MRI (rMRI) include the revelation of occult spinal disease dependent on true axial loading, the unmasking of kinetic-dependent spinal disease and the ability to scan the patient in ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-2666-4

    authors: Jinkins JR,Dworkin JS,Damadian RV

    更新日期:2005-09-01 00:00:00

  • Radio-frequency thermal ablation of liver metastases with a cooled-tip electrode needle: results of a pilot clinical trial.

    abstract::The aim of this study was to evaluate feasibility, safety, and effectiveness of radio-frequency (RF) thermal ablation, performed by using a cooled-tip electrode needle, in the treatment of liver metastases. Twenty-nine patients (20 males and 9 females; age range 43-77 years) with one to four hepatic metastases 1.1-4.8...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s003300050536

    authors: Lencioni R,Goletti O,Armillotta N,Paolicchi A,Moretti M,Cioni D,Donati F,Cicorelli A,Ricci S,Carrai M,Conte PF,Cavina E,Bartolozzi C

    更新日期:1998-01-01 00:00:00

  • Diffuse metastatic infiltration of a carcinoma into skeletal muscle.

    abstract::Skeletal muscle is one of the most unusual sites of metastasis from any malignancy. We report a patient with rapidly progressive contractures due to metastatic infiltration of a carcinoma of unknown origin into the skeletal muscle. This 61-year-old man presented with a 1-month history of rapidly evolving, painful rest...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050657

    authors: Hundt W,Braunschweig R,Reiser M

    更新日期:1999-01-01 00:00:00

  • Quantitative MR perfusion parameters related to survival time in high-grade gliomas.

    abstract:OBJECTIVES:To evaluate the quantitative parameters obtained from dynamic MR T2*-weighted images as predictors of survival taking into consideration the biasing effects of other survival-related covariates. METHODS:Thirty-nine patients (60 ± 14 years; survival 267 ± 191 days) with high-grade gliomas (8 grade III, 31 gr...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2967-y

    authors: Sanz-Requena R,Revert-Ventura A,Martí-Bonmatí L,Alberich-Bayarri A,García-Martí G

    更新日期:2013-12-01 00:00:00

  • Initial clinical experience with oral manganese (CMC-001) for liver MR imaging.

    abstract::Recently, a new oral liver-specific manganese-based MR agent (CMC-001) has been introduced. This contrast medium is delivered to the liver in high concentrations in the portal vein and very low doses in the hepatic artery, as only small amounts of manganese enter the general circulation. It is taken up by the hepatocy...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0336-9

    authors: Thomsen HS,Barentsz JO,Burcharth F,Chabanova E,Dekker HM,Moesgaard F,Moller JM,Leth-Espensen P,Logager V,Takahashi S

    更新日期:2007-01-01 00:00:00

  • Bilateral tuberculous otomastoiditis in an immmunocompetent 5-year-old child: CT and MRI findings (2009: 3b).

    abstract::Bilateral tuberculous mastoiditis (TOM) in an immunocompetent child is a very uncommon form of tuberculous infection presentation. This report shows the CT and MR imaging of bilateral tuberculous otomastoiditis consisting of aggressive signs of middle ear and mastoid involvement with bony destruction and periauricular...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1130-7

    authors: Munoz A,Ruiz-Contreras J,Jimenez A,Maté I,Calvo M,Villafruela M,del-Pozo G

    更新日期:2009-06-01 00:00:00

  • MR-guided breast biopsy and hook wire marking using a low-field (0.23 T) scanner with optical instrument tracking.

    abstract::The purpose of this study was to evaluate the technical feasibility of MR-guided percutaneous breast biopsy (LCNB) and breast hook wire marking in a low-field (0.23 T) MRI system with optical instrument tracking. MR-guided core biopsy and/or hook wire marking was performed on 13 lesions observable at MR imaging only. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0377-0

    authors: Sequeiros RB,Reinikainen H,Sequeiros AM,Vaara T,Ojala R,Pääkkö E,Tervonen O

    更新日期:2007-03-01 00:00:00

  • Automatic opportunistic osteoporosis screening using low-dose chest computed tomography scans obtained for lung cancer screening.

    abstract:OBJECTIVE:Osteoporosis is a prevalent and treatable condition, but it remains underdiagnosed. In this study, a deep learning-based system was developed to automatically measure bone mineral density (BMD) for opportunistic osteoporosis screening using low-dose chest computed tomography (LDCT) scans obtained for lung can...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06679-y

    authors: Pan Y,Shi D,Wang H,Chen T,Cui D,Cheng X,Lu Y

    更新日期:2020-07-01 00:00:00

  • Applicability and accuracy of pretest probability calculations implemented in the NICE clinical guideline for decision making about imaging in patients with chest pain of recent onset.

    abstract:OBJECTIVES:To analyse the implementation, applicability and accuracy of the pretest probability calculation provided by NICE clinical guideline 95 for decision making about imaging in patients with chest pain of recent onset. METHODS:The definitions for pretest probability calculation in the original Duke clinical sco...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5322-5

    authors: Roehle R,Wieske V,Schuetz GM,Gueret P,Andreini D,Meijboom WB,Pontone G,Garcia M,Alkadhi H,Honoris L,Hausleiter J,Bettencourt N,Zimmermann E,Leschka S,Gerber B,Rochitte C,Schoepf UJ,Shabestari AA,Nørgaard B,Sato A,

    更新日期:2018-09-01 00:00:00

  • Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose).

    abstract::In a controlled patient study we investigated the potential of attenuation-based on-line modulation of the tube current to reduce milliampere values (mAs) in CT examinations of children without loss of image quality. mAs can be reduced for non-circular patient cross sections without an increase in noise if tube curren...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1255-4

    authors: Greess H,Nömayr A,Wolf H,Baum U,Lell M,Böwing B,Kalender W,Bautz WA

    更新日期:2002-06-01 00:00:00

  • Workflow-centred evaluation of an automatic lesion tracking software for chemotherapy monitoring by CT.

    abstract:OBJECTIVES:In chemotherapy monitoring, an estimation of the change in tumour size is an important criterion for the assessment of treatment success. This requires a comparison between corresponding lesions in the baseline and follow-up computed tomography (CT) examinations. We evaluate the clinical benefits of an autom...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2545-8

    authors: Moltz JH,D'Anastasi M,Kiessling A,Pinto dos Santos D,Schülke C,Peitgen HO

    更新日期:2012-12-01 00:00:00

  • Magnetisation transfer MR imaging of the kidney: evaluation at 3.0 T in association with renal function.

    abstract:OBJECTIVE:To evaluate the feasibility of using magnetisation transfer (MT) MRI of the kidney at 3.0 T to assess renal function. METHODS:Forty-four patients who underwent abdominal MRI on a 3.0-T system including gradient-echo (GRE) sequences with and without MT pulse were included. In each patient, MT ratio (MTR) of t...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2841-y

    authors: Ito K,Hayashida M,Izumitani S,Fujimine T,Onishi T,Genba K

    更新日期:2013-08-01 00:00:00

  • Magnification survey and spot view mammography with a new microfocus X-ray unit: detail resolution and radiation exposure.

    abstract::The aim of our study was to evaluate a mammography unit capable of magnification of up to fourfold at an equivalent or lower dose than with current systems. A prototype mammography tube with an electron-beam-focusing technology resulting in a focal spot size of 40-120 micro m was combined with a highly intensifying sc...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050399

    authors: Funke M,Breiter N,Hermann K,Oestmann J,Grabbe E

    更新日期:1998-01-01 00:00:00

  • Is the iliolumbar ligament a reliable identifier of the L5 vertebra in lumbosacral transitional anomalies?

    abstract:OBJECTIVE:Sufficiently sized studies to determine the value of the iliolumbar ligament (ILL) as an identifier of the L5 vertebra in cases of a lumbosacral transitional vertebra (LSTV) are lacking. METHODS:Seventy-one of 770 patients with LSTV (case group) and 62 of 611 subjects without LSTV with confirmed L5 level wer...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3277-8

    authors: Farshad-Amacker NA,Lurie B,Herzog RJ,Farshad M

    更新日期:2014-10-01 00:00:00

  • Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT.

    abstract:OBJECTIVES:To compare image quality and radiation dose of abdominal split-filter dual-energy CT (SF-DECT) combined with monoenergetic imaging to single-energy CT (SECT) with automatic tube voltage selection (ATVS). METHODS:Two-hundred single-source abdominal CT scans were performed as SECT with ATVS (n = 100) and SF-D...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5338-x

    authors: Euler A,Obmann MM,Szucs-Farkas Z,Mileto A,Zaehringer C,Falkowski AL,Winkel DJ,Marin D,Stieltjes B,Krauss B,Schindera ST

    更新日期:2018-08-01 00:00:00