Development and evaluation of a new gray-scale test pattern to adjust gradients of thoracic CT imaging.

Abstract:

:The purpose of the present study was to evaluate the usefulness of a new gray-scale test pattern (NGTP) that was developed to easily adjust the gradients of thoracic CT imaging and enable visual consistency. The Society of Motion Picture and Television Engineers (SMPTE) pattern and the NGTP were used for comparison. The luminance character of two test patterns was evaluated by a luminance meter with three different window widths and levels (for default, mediastinum and lung). We also investigated whether SMPTE or NGTP is more suitable for adjusting the gradient of thoracic CT imaging. We found that it was easier to adjust the gradient of thoracic CT imaging with NGTP than with SMPTE, because the digital range of NGTP is 12 bits (the value of 4,096 HU, from -1,024 to 3,071 HU), and adjustable in any window width. We were able to adjust the gradients of hard-copy and soft-copy thoracic CT imaging within several hours using NGTP. We propose that NGTP is the most suitable tool for adjusting the gradients of thoracic CT imaging. NGTP can cope with any medical diagnostic display system connected with CT or MRI equipment in a network because it is in DICOM format.

journal_name

Eur Radiol

journal_title

European radiology

authors

Yamaguchi M,Fujita H,Uemura M,Asai Y,Wakae H,Ishifuro M

doi

10.1007/s00330-004-2315-3

subject

Has Abstract

pub_date

2004-12-01 00:00:00

pages

2357-61

issue

12

eissn

0938-7994

issn

1432-1084

journal_volume

14

pub_type

杂志文章
  • Patient dose reference levels in surgery: a multicenter study.

    abstract:OBJECTIVE:To assess diagnostic reference levels (DRLs) in surgery for the most frequent procedures as required by the European Directive 2013/59/Euratom. METHODS:A survey was conducted in six centers. Eight orthopedic, urology and gastrointestinal surgical procedures were analyzed. Kerma area product (KAP) and fluoros...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-018-5600-2

    authors: Greffier J,Etard C,Mares O,Pereira F,Defez D,Duverger C,Branchereau P,Beregi JP,Coulomb R,Larbi A

    更新日期:2019-02-01 00:00:00

  • Retrospective measurement of different size parameters of non-radiated rectal cancer on MR images and pathology slides and their comparison.

    abstract::There are no non-invasive methods to assess the real tumor size in rectal cancer prior to surgery, especially following radio/chemotherapy. Magnetic resonance imaging is gaining increasing acceptance as the primary modality at many centers for evaluation of pelvic malignancies including rectal cancers. The aim of this...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-1898-4

    authors: Torkzad M,Lindholm J,Martling A,Blomqvist L

    更新日期:2003-10-01 00:00:00

  • Whole-tumour diffusion kurtosis MR imaging histogram analysis of rectal adenocarcinoma: Correlation with clinical pathologic prognostic factors.

    abstract:OBJECTIVE:To investigate potential relationships between diffusion kurtosis imaging (DKI)-derived parameters using whole-tumour volume histogram analysis and clinicopathological prognostic factors in patients with rectal adenocarcinoma. MATERIAL AND METHODS:79 consecutive patients who underwent MRI examination with re...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5094-3

    authors: Cui Y,Yang X,Du X,Zhuo Z,Xin L,Cheng X

    更新日期:2018-04-01 00:00:00

  • Protocol modifications for CT perfusion (CTp) examinations of abdomen-pelvic tumors: impact on radiation dose and data processing time.

    abstract:PURPOSE:To evaluate the effect of CT perfusion (CTp) protocol modifications on quantitative perfusion parameters, radiation dose and data processing time. MATERIALS & METHODS:CTp datasets of 30 patients (21M:9F) with rectal (n = 24) or retroperitoneal (n = 6) tumours were studied. Standard CTp protocol included 50 sec...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-2048-4

    authors: Kambadakone AR,Sharma A,Catalano OA,Hahn PF,Sahani DV

    更新日期:2011-06-01 00:00:00

  • Abdominal and pelvic computed tomography (CT) interpretation: discrepancy rates among experienced radiologists.

    abstract:OBJECTIVE:To assess the discrepancy rate for the interpretation of abdominal and pelvic computed tomography (CT) examinations among experienced radiologists. METHODS:Ninety abdominal and pelvic CT examinations reported by three experienced radiologists who specialize in abdominal imaging were randomly selected from th...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1763-1

    authors: Abujudeh HH,Boland GW,Kaewlai R,Rabiner P,Halpern EF,Gazelle GS,Thrall JH

    更新日期:2010-08-01 00:00:00

  • Follow-up of breast lesions detected by MRI not biopsied due to absent enhancement of contrast medium.

    abstract::Our objective was to follow-up patients in whom scheduled MR-guided vacuum biopsies for suspicious lesions were aborted due to absent enhancement of contrast medium. Thirty-seven of 291 scheduled MR-guided vacuum biopsies were aborted. Six cases were lost to follow-up. Two could be unequivocally identified and were ne...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1713-7

    authors: Hefler L,Casselman J,Amaya B,Heinig A,Alberich T,Koelbl H,Heywang-Köbrunner SH

    更新日期:2003-02-01 00:00:00

  • Comparison of hybrid 68Ga-PSMA-PET/CT and 99mTc-DPD-SPECT/CT for the detection of bone metastases in prostate cancer patients: Additional value of morphologic information from low dose CT.

    abstract:PURPOSE:This study compared 68Gallium-prostate-specific-membrane-antigen based Positron-emission-tomography (68Ga-PSMA-PET) and 99metastabletechnetium-3,3-diphospho-1,2-propanedicarbonacid (99mTc-DPD-SPECT) in performing skeletal staging in prostate cancer (PC) patients and evaluated the additional value of the informa...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4994-6

    authors: Janssen JC,Meißner S,Woythal N,Prasad V,Brenner W,Diederichs G,Hamm B,Makowski MR

    更新日期:2018-02-01 00:00:00

  • The performance of 3D ABUS versus HHUS in the visualisation and BI-RADS characterisation of breast lesions in a large cohort of 1,886 women.

    abstract:OBJECTIVES:This study aimed to evaluate automated breast ultrasound (ABUS) compared to hand-held traditional ultrasound (HHUS) in the visualisation and BIRADS characterisation of breast lesions. MATERIALS AND METHODS:From January 2016 to January 2017, 1,886 women with breast density category C or D (aged 48.6±10.8 yea...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-017-5011-9

    authors: Vourtsis A,Kachulis A

    更新日期:2018-02-01 00:00:00

  • Polyp measurement based on CT colonography and colonoscopy: variability and systematic differences.

    abstract:OBJECTIVE:To assess the variability and systematic differences in polyp measurements on optical colonoscopy and CT colonography. MATERIALS:Gastroenterologists measured 51 polyps by visual estimation, forceps comparison and linear probe. CT colonography observers randomly assessed polyp size two-dimensionally (abdomina...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1683-0

    authors: de Vries AH,Bipat S,Dekker E,Liedenbaum MH,Florie J,Fockens P,van der Kraan R,Mathus-Vliegen EM,Reitsma JB,Truyen R,Vos FM,Zwinderman AH,Stoker J

    更新日期:2010-06-01 00:00:00

  • Computed tomography-guided lung biopsy: a randomized controlled trial of low-dose versus standard-dose protocol.

    abstract:OBJECTIVES:To assess the relative diagnostic utility of low- and standard-dose computed tomography (CT)-guided lung biopsy. METHODS:In this single-center, single-blind, prospective, randomized controlled trial, patients were enrolled between November 2016 and June 2017. Enrolled study participants were randomly select...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06464-6

    authors: Fu YF,Li GC,Xu QS,Shi YB,Wang C,Wang T

    更新日期:2020-03-01 00:00:00

  • Computed tomography of acute pulmonary embolism: state-of-the-art.

    abstract::Multidetector computed tomography (CT) plays an important role in the detection, risk stratification and prognosis evaluation of acute pulmonary embolism. This review will discuss the technical improvements for imaging peripheral pulmonary arteries, the methods of assessing pulmonary embolism severity based on CT find...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-015-3679-2

    authors: Zhang LJ,Lu GM,Meinel FG,McQuiston AD,Ravenel JG,Schoepf UJ

    更新日期:2015-09-01 00:00:00

  • Pancreatic MRI for the surveillance of cystic neoplasms: comparison of a short with a comprehensive imaging protocol.

    abstract:OBJECTIVES:The study aims were to evaluate: (1) whether a short-protocol (SP) MRI for the surveillance of pancreatic cystic neoplasms (PCN) provides equivalent clinical information as a comprehensive-protocol (CP), and (2) the cost reduction from substituting CP with SP for patient surveillance. METHODS:This retrospec...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4377-4

    authors: Pozzi-Mucelli RM,Rinta-Kiikka I,Wünsche K,Laukkarinen J,Labori KJ,Ånonsen K,Verbeke C,Del Chiaro M,Kartalis N

    更新日期:2017-01-01 00:00:00

  • Non-traumatic thoracic emergencies: imaging and treatment of thoracic fluid collections (including pneumothorax).

    abstract::Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-002-1512-1

    authors: Ellis JR,Gleeson FV

    更新日期:2002-08-01 00:00:00

  • A novel approach to digital breast tomosynthesis for simultaneous acquisition of 2D and 3D images.

    abstract:OBJECTIVE:The complexity of anatomical structure within the breast represents the ultimate limit to signal detection on a mammogram. To increase lesion conspicuity Digital Breast Tomosynthesis (DBT) has been recently proposed and several manufacturers are currently performing clinical trials. In this study we investiga...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-2041-y

    authors: Vecchio S,Albanese A,Vignoli P,Taibi A

    更新日期:2011-06-01 00:00:00

  • Dynamic contrast-enhanced magnetic resonance imaging with Gd-EOB-DTPA for the evaluation of liver fibrosis in chronic hepatitis patients.

    abstract:OBJECTIVES:To develop a non-invasive MRI method for evaluation of liver fibrosis, with histological analysis as the reference standard. METHODS:The study protocol was approved by the Institutional Review Board for Human Studies of our hospital, and written informed consent was obtained from all subjects. Seventy-nine ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2249-5

    authors: Chen BB,Hsu CY,Yu CW,Wei SY,Kao JH,Lee HS,Shih TT

    更新日期:2012-01-01 00:00:00

  • Macroscopic heterogeneity of liver fat: an MR-based study in type-2 diabetic patients.

    abstract:OBJECTIVE:To assess the heterogeneity of liver fat deposition with MR of the liver in type-2 diabetic (T2D) patients. METHODS:We enrolled 121 consecutive T2D patients. The reference standard was 3.0-T (1)H-MR spectroscopy. Hepatic steatosis was defined as liver fat content (LFC) ≥5.56 %. A triple-echo gradient-echo se...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2468-4

    authors: Capitan V,Petit JM,Aho S,Lefevre PH,Favelier S,Loffroy R,Hillon P,Krausé D,Cercueil JP,Guiu B

    更新日期:2012-10-01 00:00:00

  • Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with ¹⁵O-H₂O PET.

    abstract:OBJECTIVES:This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against (15)O-H₂O positron-emission tomography (PET) and assesses the CFRs of coronary artery d...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-014-3164-3

    authors: Kikuchi Y,Oyama-Manabe N,Naya M,Manabe O,Tomiyama Y,Sasaki T,Katoh C,Kudo K,Tamaki N,Shirato H

    更新日期:2014-07-01 00:00:00

  • Congenital absence of the internal carotid artery and the basilar artery with persistent trigeminal artery associated with coarctation of the aorta.

    abstract::We report a case of congenital absence of the cervical and petrous part of the left internal carotid artery, the middle and proximal part of the basilar artery, and the V4 segment of the left vertebral artery associated with a left persistent trigeminal artery and a coarctation of the aorta. The left cerebral vessels ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000500

    authors: Jaeger HJ,Mehring UM,Gissler HM,Mathias KD

    更新日期:2000-01-01 00:00:00

  • Quantitative analysis of dynamic airway changes after methacholine and salbutamol inhalation on xenon-enhanced chest CT.

    abstract:OBJECTIVES:To investigate the dynamic changes in airways in response to methacholine and salbutamol inhalation and to correlate the xenon ventilation index on xenon-enhanced chest CTs in asthmatics. METHODS:Thirty-one non-smokers (6 normal, 25 asthmatics) underwent xenon-enhanced chest CT and pulmonary function tests....

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2516-0

    authors: Park SJ,Lee CH,Goo JM,Kim JH,Park EA,Jung JW,Park HW,Cho SH

    更新日期:2012-11-01 00:00:00

  • Comparison of semi-automated and manual methods to measure the volume of liver tumours on MDCT images.

    abstract:OBJECTIVE:To retrospectively compare semi-automated and manual volume measurements of malignant liver tumours and inter- and intra-observer variability using commercially available software. METHODS:This study was performed on 60 consecutive patients with untreated liver metastases (30) and HCCs (30), i.e. 92 lesions ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-2013-2

    authors: Dubus L,Gayet M,Zappa M,Abaleo L,De Cooman A,Orieux G,Vilgrain V

    更新日期:2011-05-01 00:00:00

  • 3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography.

    abstract::This study aimed to evaluate the influence of a new navigator technique (3D MAG) on navigator efficiency, total acquisition time, image quality and diagnostic accuracy. Fifty-six patients with suspected coronary artery disease underwent free breathing navigator gated coronary MRA (Intera, Philips Medical Systems, 1.5 ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-2731-z

    authors: Hackenbroch M,Nehrke K,Gieseke J,Meyer C,Tiemann K,Litt H,Dewald O,Naehle CP,Schild H,Sommer T

    更新日期:2005-08-01 00:00:00

  • Automatically computed rating scales from MRI for patients with cognitive disorders.

    abstract:OBJECTIVES:The aims of this study were to examine whether visual MRI rating scales used in diagnostics of cognitive disorders can be estimated computationally and to compare the visual rating scales with their computed counterparts in differential diagnostics. METHODS:A set of volumetry and voxel-based morphometry ima...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06067-1

    authors: Koikkalainen JR,Rhodius-Meester HFM,Frederiksen KS,Bruun M,Hasselbalch SG,Baroni M,Mecocci P,Vanninen R,Remes A,Soininen H,van Gils M,van der Flier WM,Scheltens P,Barkhof F,Erkinjuntti T,Lötjönen JMP,Alzheimer’s Disease N

    更新日期:2019-09-01 00:00:00

  • A hand-held ultrasound machine vs. conventional ultrasound machine in the bedside assessment of post-liver transplant patients.

    abstract::The purpose was to assess the diagnostic accuracy of a hand-held Doppler ultrasound (US) machine for the bedside detection of liver and vascular abnormalities after liver transplantation in the intensive care unit. The IRB approved this study, and written informed consent was obtained from all patients or the patient'...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00330-009-1417-3

    authors: Trinquart L,Bruno O,Angeli ML,Belghiti J,Chatellier G,Vilgrain V

    更新日期:2009-10-01 00:00:00

  • Hepatic ADC map as an adjunct to conventional abdominal MRI to evaluate hepatic fibrotic and clinical cirrhotic severity in biliary atresia patients.

    abstract:OBJECTIVES:Hepatic apparent diffusion coefficient (ADC) values and ADC-related indices were correlated with the Mayo risk score for primary biliary cirrhosis (MRSPBC) and METAVIR scores of liver specimens to determine the clinical and pathological significance of diffusion-weighted magnetic resonance imaging (DWMRI). ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3716-1

    authors: Peng SS,Jeng YM,Hsu WM,Yang JC,Ho MC

    更新日期:2015-10-01 00:00:00

  • A patient with swelling of the eyelid: ancient schwannoma of the supraorbital nerve (2010:6b).

    abstract::We present a case of swelling of the eyelid and supraorbital anesthesia caused by an intraorbital tumor. The differential diagnosis based on imaging consisted of aneurysmal bone cyst, schwannoma, neurofibroma, dermoid cyst, and cavernous hemangioma. The surgical and pathological diagnosis was an ancient schwannoma of ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1659-0

    authors: de Jong L,Demaerel P,Sciot R,Van Calenbergh F

    更新日期:2010-09-01 00:00:00

  • 3D Dixon water-fat LGE imaging with image navigator and compressed sensing in cardiac MRI.

    abstract:OBJECTIVES:To evaluate an image-navigated isotropic high-resolution 3D late gadolinium enhancement (LGE) prototype sequence with compressed sensing and Dixon water-fat separation in a clinical routine setting. MATERIAL AND METHODS:Forty consecutive patients scheduled for cardiac MRI were enrolled prospectively and exa...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07517-x

    authors: Zeilinger MG,Wiesmüller M,Forman C,Schmidt M,Munoz C,Piccini D,Kunze KP,Neji R,Botnar RM,Prieto C,Uder M,May M,Wuest W

    更新日期:2020-12-02 00:00:00

  • Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: technical background, basic image quality parameters, and review of the literature.

    abstract::The two most frequently performed diagnostic X-ray examinations are those of the extremities and of the chest. Thus, dose reduction in the field of conventional skeletal and chest radiography is an important issue and there is a need to reduce man-made ionizing radiation. The large-area flat-panel detector based on am...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2243-2

    authors: Völk M,Hamer OW,Feuerbach S,Strotzer M

    更新日期:2004-05-01 00:00:00

  • The changed preliminary report: a repeatedly missed paediatric tibial tumour.

    abstract::This report describes a malpractice case involving a delayed diagnosis of a malignant bone tumour in the proximal tibia in a 10-year-old child. This was caused by a combination of factors. The final report on the first examination failed to reach the patient files, and two subsequent X-ray exams failed to diagnose the...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300051021

    authors: Finnbogason T,Ringertz HG

    更新日期:2000-01-01 00:00:00

  • Impact of model-based iterative reconstruction on low-contrast lesion detection and image quality in abdominal CT: a 12-reader-based comparative phantom study with filtered back projection at different tube voltages.

    abstract:OBJECTIVES:To evaluate the impact of model-based iterative reconstruction (MBIR) on image quality and low-contrast lesion detection compared with filtered back projection (FBP) in abdominal computed tomography (CT) of simulated medium and large patients at different tube voltages. METHODS:A phantom with 45 hypoattenua...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4825-9

    authors: Euler A,Stieltjes B,Szucs-Farkas Z,Eichenberger R,Reisinger C,Hirschmann A,Zaehringer C,Kircher A,Streif M,Bucher S,Buergler D,D'Errico L,Kopp S,Wilhelm M,Schindera ST

    更新日期:2017-12-01 00:00:00

  • Perfusion CT in patients with advanced bronchial carcinomas: a novel chance for characterization and treatment monitoring?

    abstract::Advanced bronchial carcinomas by means of perfusion and peak enhancement using dynamic contrast-enhanced multislice CT are characterized. Twenty-four patients with advanced bronchial carcinoma were examined. During breathhold, after injection of a contrast-medium (CM), 25 scans were performed (1 scan/s) at a fixed tab...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2288-2

    authors: Kiessling F,Boese J,Corvinus C,Ederle JR,Zuna I,Schoenberg SO,Brix G,Schmähl A,Tuengerthal S,Herth F,Kauczor HU,Essig M

    更新日期:2004-07-01 00:00:00