Radio-frequency thermal ablation of liver metastases with a cooled-tip electrode needle: results of a pilot clinical trial.

Abstract:

:The aim of this study was to evaluate feasibility, safety, and effectiveness of radio-frequency (RF) thermal ablation, performed by using a cooled-tip electrode needle, in the treatment of liver metastases. Twenty-nine patients (20 males and 9 females; age range 43-77 years) with one to four hepatic metastases 1.1-4.8 cm in diameter (mean 2.9 +/- 0.8 cm) from previously resected intra-abdominal primary malignancies were treated. All patients were excluded from surgery and had partial or no response to chemotherapy. Radio-frequency ablation was performed by using a 100-W generator and 17-gauge, dual-lumen, cooled-tip electrode needles with a 2- to 3-cm exposed tip. Exposure time was 12 min for each needle insertion. Findings at spiral CT were used to assess the therapeutic response. A total of 127 insertions were performed (mean 2.4 +/- 1.7 insertions/lesion) during 84 treatment sessions (mean 1.6 +/- 0.7 sessions/lesion) in absence of major complications. Complete tumor response (i. e., unenhancing area of thermal necrosis larger than the treated tumor) was seen in 41 (77 %) of 53 lesions, including 33 (87 %) of 38 lesions 3 cm or less in diameter. After a mean follow-up period of 6.5 +/- 2.1 months (range 3-9 months), recurrence of the treated lesion was seen in 5 (12 %) of the 41 cases. New metastatic lesions appeared in 7 patients. Two patients died after 6 and 8 months, respectively. Of the 27 patients still in follow-up, 14 are currently free of disease. Radio-frequency thermal ablation with a cooled-tip electrode needle is a safe and effective local treatment for hepatic metastases 3 cm or less in greatest dimension.

journal_name

Eur Radiol

journal_title

European radiology

authors

Lencioni R,Goletti O,Armillotta N,Paolicchi A,Moretti M,Cioni D,Donati F,Cicorelli A,Ricci S,Carrai M,Conte PF,Cavina E,Bartolozzi C

doi

10.1007/s003300050536

subject

Has Abstract

pub_date

1998-01-01 00:00:00

pages

1205-11

issue

7

eissn

0938-7994

issn

1432-1084

journal_volume

8

pub_type

临床试验,杂志文章
  • Correlation between quantitative assessment of contrast enhancement in contrast-enhanced spectral mammography (CESM) and histopathology-preliminary results.

    abstract:OBJECTIVES:Contrast-enhanced spectral mammography (CESM) is a novel method for breast cancer detection. The aim of this study is to check if there is a possibility of quantitative assessment of contrast enhancement in CESM and if there is any correlation between quantitative assessment of contrast enhancement in CESM a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06232-6

    authors: Rudnicki W,Heinze S,Niemiec J,Kojs Z,Sas-Korczynska B,Hendrick E,Luczynska E

    更新日期:2019-11-01 00:00:00

  • Intravoxel incoherent motion (IVIM) 3 T MRI for orbital lesion characterization.

    abstract:OBJECTIVES:To determine the diagnostic accuracy of MRI intravoxel incoherent motion (IVIM) when characterizing orbital lesions, which is challenging due to a wide range of locations and histologic types. METHODS:This IRB-approved prospective single-center study enrolled participants presenting with an orbital lesion u...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07103-1

    authors: Lecler A,Duron L,Zmuda M,Zuber K,Bergès O,Putterman M,Savatovsky J,Fournier L

    更新日期:2021-01-01 00:00:00

  • Ultrasound of the chest in children (mediastinum excluded).

    abstract::Ultrasound (US) of the paediatric chest has become an established imaging tool that may supplement plain film findings helping to reduce or tailor other ionizing (sectional) imaging in a variety of paediatric conditions such as sequestration or pneumonia. US has been shown to offer valuable imaging alternatives, both ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-007-0754-3

    authors: Riccabona M

    更新日期:2008-02-01 00:00:00

  • Differences in perfusion parameters between upper and lower lumbar vertebral segments with dynamic contrast-enhanced MRI (DCE MRI).

    abstract::To investigate the influence of age, sex and spinal level on perfusion parameters of normal lumbar bone marrow with dynamic contrast-enhanced MRI (DCE MRI). Sixty-seven subjects referred for evaluation of low back pain or sciatica underwent DCE MRI of the lumbar spine. After subtraction of dynamic images, a region of ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-0943-8

    authors: Savvopoulou V,Maris TG,Vlahos L,Moulopoulos LA

    更新日期:2008-09-01 00:00:00

  • The performance of 3D ABUS versus HHUS in the visualisation and BI-RADS characterisation of breast lesions in a large cohort of 1,886 women.

    abstract:OBJECTIVES:This study aimed to evaluate automated breast ultrasound (ABUS) compared to hand-held traditional ultrasound (HHUS) in the visualisation and BIRADS characterisation of breast lesions. MATERIALS AND METHODS:From January 2016 to January 2017, 1,886 women with breast density category C or D (aged 48.6±10.8 yea...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-017-5011-9

    authors: Vourtsis A,Kachulis A

    更新日期:2018-02-01 00:00:00

  • A hand-held ultrasound machine vs. conventional ultrasound machine in the bedside assessment of post-liver transplant patients.

    abstract::The purpose was to assess the diagnostic accuracy of a hand-held Doppler ultrasound (US) machine for the bedside detection of liver and vascular abnormalities after liver transplantation in the intensive care unit. The IRB approved this study, and written informed consent was obtained from all patients or the patient'...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00330-009-1417-3

    authors: Trinquart L,Bruno O,Angeli ML,Belghiti J,Chatellier G,Vilgrain V

    更新日期:2009-10-01 00:00:00

  • A pregnant lady with intermittent vaginal bleeding (2007: 3b). Placenta percreta.

    abstract::Placenta percreta is a potentially life-threatening complication of pregnancy, which is increasing in incidence. Ante-natal diagnosis with ultrasound and magnetic resonance imaging aids the obstetric team in planning further management. We present a case of placenta percreta with imaging and a brief review of the lite...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0498-5

    authors: Koo BC,Sala E,Hackett GA,Shaw AS

    更新日期:2007-06-01 00:00:00

  • High-pitch low-voltage CT coronary artery calcium scoring with tin filtration: accuracy and radiation dose reduction.

    abstract:OBJECTIVES:To investigate diagnostic accuracy and radiation dose of high-pitch CT coronary artery calcium scoring (CACS) with tin filtration (Sn100kVp) versus standard 120kVp high-pitch acquisition. METHODS:78 patients (58% male, 61.5±9.1 years) were prospectively enrolled. Subjects underwent clinical 120kVp high-pitc...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5249-2

    authors: Apfaltrer G,Albrecht MH,Schoepf UJ,Duguay TM,De Cecco CN,Nance JW,De Santis D,Apfaltrer P,Eid MH,Eason CD,Thompson ZM,Bauer MJ,Varga-Szemes A,Jacobs BE,Sorantin E,Tesche C

    更新日期:2018-07-01 00:00:00

  • Contrast-enhanced time-resolved 4D MRA of congenital heart and vessel anomalies: image quality and diagnostic value compared with 3D MRA.

    abstract:OBJECTIVES:To evaluate time-resolved interleaved stochastic trajectories (TWIST) contrast-enhanced 4D magnetic resonance angiography (MRA) and compare it with 3D FLASH MRA in patients with congenital heart and vessel anomalies. METHODS:Twenty-six patients with congenital heart and vessel anomalies underwent contrast-e...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2845-7

    authors: Vogt FM,Theysohn JM,Michna D,Hunold P,Neudorf U,Kinner S,Barkhausen J,Quick HH

    更新日期:2013-09-01 00:00:00

  • COVID-19 pneumonia: CT findings of 122 patients and differentiation from influenza pneumonia.

    abstract:OBJECTIVES:To investigate the clinical and chest CT characteristics of COVID-19 pneumonia and explore the radiological differences between COVID-19 and influenza. MATERIALS AND METHODS:A total of 122 patients (61 men and 61 women, 48 ± 15 years) confirmed with COVID-19 and 48 patients (23 men and 25 women, 47 ± 19 yea...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06928-0

    authors: Liu M,Zeng W,Wen Y,Zheng Y,Lv F,Xiao K

    更新日期:2020-10-01 00:00:00

  • Comparison of videofluoroscopy and impedance planimetry for the evaluation of oesophageal stenosis: a retrospective study.

    abstract:OBJECTIVES:To compare videofluoroscopy that included a tablet test with impedance planimetry (EndoFLIP®) for the evaluation of oesophageal stenosis in patients with dysphagia. METHODS:In 56 patients, videofluoroscopic examinations following the transit of a 14-mm tablet were retrospectively reviewed and correlated wit...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4516-y

    authors: Scharitzer M,Lenglinger J,Schima W,Weber M,Ringhofer C,Pokieser P

    更新日期:2017-04-01 00:00:00

  • Quantification of diffusion tensor imaging in normal white matter maturation of early childhood using an automated processing pipeline.

    abstract:OBJECTIVES:The degree and status of white matter myelination can be sensitively monitored using diffusion tensor imaging (DTI). This study looks at the measurement of fractional anistropy (FA) and mean diffusivity (MD) using an automated ROI with an existing DTI atlas. METHODS:Anatomical MRI and structural DTI were pe...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2396-3

    authors: Loh KB,Ramli N,Tan LK,Roziah M,Rahmat K,Ariffin H

    更新日期:2012-07-01 00:00:00

  • High resolution MRI of the breast at 3 T: which BI-RADS® descriptors are most strongly associated with the diagnosis of breast cancer?

    abstract:OBJECTIVE:To identify which breast lesion descriptors in the ACR BI-RADS® MRI lexicon are most strongly associated with the diagnosis of breast cancer when performing breast MR imaging at 3 T. METHODS:150 patients underwent breast MR imaging at 3 T. Lesion size, morphology and enhancement kinetics were assessed accord...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2256-6

    authors: Pinker-Domenig K,Bogner W,Gruber S,Bickel H,Duffy S,Schernthaner M,Dubsky P,Pluschnig U,Rudas M,Trattnig S,Helbich TH

    更新日期:2012-02-01 00:00:00

  • Pancreatic adenocarcinoma.

    abstract::Adenocarcinoma is the most common malignant pancreatic tumor, affecting the head of the pancreas in 60-70% of cases. By the time of diagnosis, at least 80% of tumors are unresectable. Helical computed tomography (CT) is very effective in detecting and staging adenocarcinoma, with a sensitivity of up to 90% for detecti...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-006-0435-7

    authors: Schima W,Ba-Ssalamah A,Kölblinger C,Kulinna-Cosentini C,Puespoek A,Götzinger P

    更新日期:2007-03-01 00:00:00

  • Sonographic diagnosis of colitis in children.

    abstract::To assist the radiologist in differentiating the colitis in children, this review proposes a systematic US approach to the disease, presents the US aspect of the normal colon and describes three distinctive US patterns reflecting the intramural extension of the histopathological changes. Each pattern corresponds to on...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2358-5

    authors: Baud C,Saguintaah M,Veyrac C,Couture A,Ferran JL,Barnéon G,Veyrac M

    更新日期:2004-11-01 00:00:00

  • Imaging of cavitary necrosis in complicated childhood pneumonia.

    abstract::The aim of this study was to illustrate the chest radiographs (CR) and CT imaging features and sequential findings of cavitary necrosis in complicated childhood pneumonia. Among 30 children admitted in the Pediatric Intensive Care Unit for persistent or progressive pneumonia, respiratory distress or sepsis despite ade...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300101008

    authors: Hodina M,Hanquinet S,Cotting J,Schnyder P,Gudinchet F

    更新日期:2002-02-01 00:00:00

  • White matter integrity associated with clinical symptoms in tinnitus patients: A tract-based spatial statistics study.

    abstract:OBJECTIVE:To assess the relationship between white matter (WM) integrity and clinical variables in tinnitus patients using diffusion tensor imaging (DTI). METHODS:Sixty-seven tinnitus patients and 39 healthy controls were enrolled in this study. The tinnitus duration, laterality, pitch and characteristics, and two psy...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4034-3

    authors: Ryu CW,Park MS,Byun JY,Jahng GH,Park S

    更新日期:2016-07-01 00:00:00

  • Cardiac CT: coronary arteries and beyond.

    abstract::Multi-detector-row computed tomography (MDCT) has emerged as a rapidly developing method for non-invasive imaging of the heart. An understanding of ECG synchronization, contrast material administration, patient preparation and image post-processing is needed to optimize image quality. The basic technical principles an...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-006-0433-9

    authors: Mahnken AH,Mühlenbruch G,Günther RW,Wildberger JE

    更新日期:2007-04-01 00:00:00

  • Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications.

    abstract::Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2236-1

    authors: Reimer P,Schneider G,Schima W

    更新日期:2004-04-01 00:00:00

  • Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience.

    abstract:OBJECTIVE:To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. METHODS:One hundred and sixty patients were randomly divided into two sc...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4349-8

    authors: Lv P,Liu J,Chai Y,Yan X,Gao J,Dong J

    更新日期:2017-01-01 00:00:00

  • The diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult patients: A systematic review and diagnostic meta-analysis.

    abstract:OBJECTIVE:To evaluate the diagnostic performance of reduced-dose CT for suspected appendicitis. METHODS:A systematic search of the MEDLINE and EMBASE databases was carried out through to 10 January 2017. Studies evaluating the diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析,评审

    doi:10.1007/s00330-017-5231-z

    authors: Yoon HM,Suh CH,Cho YA,Kim JR,Lee JS,Jung AY,Kim JH,Lee JY,Kim SY

    更新日期:2018-06-01 00:00:00

  • The uptake transporter OATP8 expression decreases during multistep hepatocarcinogenesis: correlation with gadoxetic acid enhanced MR imaging.

    abstract:OBJECTIVES:To clarify the changes in organic anion-transporting polypeptide 8 (OATP8) expression and enhancement ratio on gadoxetic acid-enhanced MR imaging in hepatocellular nodules during multistep hepatocarcinogenesis. METHODS:In imaging analysis, we focused on 71 surgically resected hepatocellular carcinomas (well...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2165-8

    authors: Kitao A,Matsui O,Yoneda N,Kozaka K,Shinmura R,Koda W,Kobayashi S,Gabata T,Zen Y,Yamashita T,Kaneko S,Nakanuma Y

    更新日期:2011-10-01 00:00:00

  • 3D MR angiography with ramp-shaped flip-angle distribution.

    abstract::This study addressed the use of 3D MR angiography with flip angles (FAs) linearly varying across the excitation volume in order to diminish spin saturation. The shape of the ramp profile was varied to optimize the method for different regions and pathological alterations. Radio frequency pulses with ramp-shaped excita...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF00182478

    authors: Martos J,Nägele T,Klose U,Petersen D,Voigt K

    更新日期:1996-01-01 00:00:00

  • Integrated diagnostic imaging of primary thoracic rhabdomyosarcoma.

    abstract::We report a rare case of primary thoracic rhabdomyosarcoma in a girl who was referred with acute chest pain, hacking cough, and wheezing. A chest X-ray revealed a complete opacity of the right hemithorax. Ultrasound revealed a right-sided pleural effusion and a solid mass above the liver dome, suggesting a neoplastic ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000507

    authors: Almberger M,Iannicelli E,Matrunola M,Schiavetti A,Capocaccia P

    更新日期:2001-01-01 00:00:00

  • Percutaneous thrombectomy: a review.

    abstract::Percutaneous thrombectomy (PT) is an established technique for the removal of acute thrombus in occluded arteries, veins and vascular grafts. Percutaneous thrombectomy can be used as an adjunctive treatment to other methods of thrombus removal such as thrombolysis or as sole therapy. The two main methods are percutane...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300101014

    authors: Morgan R,Belli AM

    更新日期:2002-01-01 00:00:00

  • Contrast media: interactions with other drugs and clinical tests.

    abstract::Many patients with multiple medical problems who are receiving a variety of drugs are investigated with imaging techniques which require intravascular contrast media. The Contrast Media Safety Committee of the European Society of Urogenital Radiology therefore decided to review the literature and to draw up simple gui...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2600-1

    authors: Morcos SK,Thomsen HS,Exley CM,Members of Contrast Media Safety Committee of European Society of Urogenital Radiology (ESUR).

    更新日期:2005-07-01 00:00:00

  • A novel approach to digital breast tomosynthesis for simultaneous acquisition of 2D and 3D images.

    abstract:OBJECTIVE:The complexity of anatomical structure within the breast represents the ultimate limit to signal detection on a mammogram. To increase lesion conspicuity Digital Breast Tomosynthesis (DBT) has been recently proposed and several manufacturers are currently performing clinical trials. In this study we investiga...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-2041-y

    authors: Vecchio S,Albanese A,Vignoli P,Taibi A

    更新日期:2011-06-01 00:00:00

  • Accelerated myelination associated with venous congestion.

    abstract::Magnetic resonance imaging is currently the gold standard in the assessment of brain myelination. The normal pattern of brain myelination conforms to a fixed chronological sequence. Focal accelerated myelination is a usual pathological state and previously has only been associated with Sturge-Weber syndrome. The purpo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-0044-x

    authors: Porto L,Kieslich M,Yan B,Zanella FE,Lanfermann H

    更新日期:2006-04-01 00:00:00

  • Preoperative T staging of gastric carcinoma obtained by MDCT vessel probe reconstructions and correlations with histological findings.

    abstract::This study aims to evaluate the diagnostic accuracy of 16-row multidetector CT (MDCT) and vessel probe reconstructions in the T staging of gastric carcinoma. Fifty-three patients (39 men, 14 women, mean age 57.5) with an endoscopic diagnosis of gastric adenocarcinoma underwent CT examination. A hypotonic drug was admi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1482-7

    authors: Moschetta M,Stabile Ianora AA,Anglani A,Marzullo A,Scardapane A,Angelelli G

    更新日期:2010-01-01 00:00:00

  • Erdheim-Chester disease: a case report and literature overview.

    abstract::Erdheim-Chester (EC) disease belongs to the group of lipoid granulomatosis. Symmetric sclerosis of the meta- and diaphysis of long tubular bones are pathognomonic radiologic changes. Additionally, other skeletal segments can be affected. Extraskeletal manifestations can occur in almost all organs; lungs, pericardium, ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050647

    authors: Kenn W,Stäbler A,Zachoval R,Zietz C,Raum W,Wittenberg G

    更新日期:1999-01-01 00:00:00