Giant cell tumors of the tendon sheath may present radiologically as intrinsic osseous lesions.

Abstract:

:The purpose of this study was to explain radiographic features of giant cell tumors of the tendon sheath (GCTTS), in particular, osseous extension, by correlating imaging findings with histology in order to increase the accuracy of radiological diagnosis. In a series of 200 consecutive osseous (pseudo) tumors of the hand, on radiography, six patients presented with an intrinsic osseous lesion caused by a histologically confirmed neighboring GCTTS. Available radiographs, computed tomography (CT), and contrast-enhanced magnetic resonance (MR) images were correlated with histology. Radiography showed osseous lesions consisting of well-defined cortical defects in four (one of whom also demonstrated cortical scalloping) and a slightly expansile, well-defined osteolytic lesion in two patients. MR obtained in four patients showed the extraosseous tumor invading/eroding bone and causing cortical scalloping (three and one patients, respectively). Extension depicted on MR was confirmed on the two available resection specimens. All lesions were polylobular (cauliflower or mushroom like) and neighboring tendon sheaths. Dense collagen and hemosiderin-loaded macrophages explained the high CT attenuation and the low MR signal intensity on T2-weighted images that was observed in all four MR and in all two CT scans. The high density of proliferative capillaries explained the marked enhancement observed in all four patients with gadolinium (Gd)-chelate-enhanced MR imaging. GCTTS is a soft tissue (pseudo) tumor that may invade bone and as a consequence mimick an intrinsic osseous lesion on radiographs. In such cases, specific MR and CT features that can be explained by histological findings can be used to suggest the correct diagnosis.

journal_name

Eur Radiol

journal_title

European radiology

authors

De Schepper AM,Hogendoorn PC,Bloem JL

doi

10.1007/s00330-006-0320-4

subject

Has Abstract

pub_date

2007-02-01 00:00:00

pages

499-502

issue

2

eissn

0938-7994

issn

1432-1084

journal_volume

17

pub_type

杂志文章
  • Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions.

    abstract::The objective of this study was to compare screen-film mammography (SFM) to full-field digital mammography (FFDM) regarding image quality as well as detectability and characterization of lesions using equivalent images of the same patient acquired with both systems. Two mammography units were used, one with a screen-f...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1269-y

    authors: Obenauer S,Luftner-Nagel S,von Heyden D,Munzel U,Baum F,Grabbe E

    更新日期:2002-07-01 00:00:00

  • Contrast-enhanced computed tomographic colonography in the follow-up of colorectal cancer patients: a feasibility study.

    abstract::The aim of our study was to assess whether contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up program of colorectal cancer patients. Thirty-five patients, surgically treated for colorectal cancer, underwent a follow-up program that in...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1696-4

    authors: Laghi A,Iannaccone R,Bria E,Carbone I,Trasatti L,Piacentini F,Lauro S,Vecchione A,Passariello R

    更新日期:2003-04-01 00:00:00

  • Chemical exchange saturation transfer MR imaging of Parkinson's disease at 3 Tesla.

    abstract:OBJECTIVES:To demonstrate the feasibility of using chemical exchange saturation transfer (CEST) imaging to detect Parkinson's disease (PD) in patients at 3 Tesla. METHODS:Twenty-seven PD patients (17 men and 10 women; age range, 54-77 years) and 22 age-matched normal controls (13 men and 9 women; age range, 55-73 year...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3241-7

    authors: Li C,Peng S,Wang R,Chen H,Su W,Zhao X,Zhou J,Chen M

    更新日期:2014-10-01 00:00:00

  • Citations in scientific articles: possibly biased reflections on the field of diagnostic imaging.

    abstract::This Editorial Comment refers to the article "Citation Bias in Imaging Research: Are studies with higher diagnostic accuracy estimates cited more often?" by Frank RA, Sharifabadi AD, Salameh JP et al, Eur Radiol. 2018 Nov 15. https://doi.org/10.1007/s00330-018-5801-8 [1]. ...

    journal_title:European radiology

    pub_type: 评论,社论

    doi:10.1007/s00330-018-5974-1

    authors: Sundermann B

    更新日期:2019-04-01 00:00:00

  • Classification of hypervascularized lesions in CE MR imaging of the breast.

    abstract::The purpose of this paper is to define and evaluate a classification category for contrast-enhanced (CE) MR imaging of the breast based on the BI-RADS mammographic categories of the American College of Radiology. Using five evaluation criteria for MR findings (initial signal increase, post-initial signal behavior, sha...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1213-1

    authors: Baum F,Fischer U,Vosshenrich R,Grabbe E

    更新日期:2002-05-01 00:00:00

  • Usefulness of colour Doppler flow imaging in the management of lacrimal gland lesions.

    abstract:OBJECTIVE:To assess the role of colour Doppler flow imaging (CDFI) in the diagnosis and management of lacrimal fossa lesions. METHODS:Institutional ethical committee approval was obtained. Fifty-one patients with 62 lacrimal fossa lesions were retrospectively included from 2003-2015. All patients underwent conventiona...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4438-8

    authors: Lecler A,Boucenna M,Lafitte F,Koskas P,Nau E,Jacomet PV,Galatoire O,Morax S,Putterman M,Mann F,Héran F,Sadik JC,Picard H,Bergès O

    更新日期:2017-02-01 00:00:00

  • Multislice spiral CT angiography in peripheral arterial occlusive disease: a valuable tool in detecting significant arterial lumen narrowing?

    abstract::The aim of this study was to evaluate the potential of multislice CT angiography (CTA) in detecting hemodynamically significant (> or =70%) lesions of lower extremity inflow and runoff arteries. Fifty patients (42 men, 8 women; mean age 68 years) with peripheral arterial occlusive disease underwent multislice spiral C...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2289-1

    authors: Portugaller HR,Schoellnast H,Hausegger KA,Tiesenhausen K,Amann W,Berghold A

    更新日期:2004-09-01 00:00:00

  • Arteritis following intra-arterial chemotherapy for liver tumors.

    abstract::Primary and metastatic tumors of the liver can be treated successfully with transcatheter chemoembolization (TACE) during selective arterial catheterism. Arteritis is a possible referred side effect which can lead to tortuosity of the arteries, stenosis and occlusion of vessels. In our hospitals 117 consecutive patien...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050159

    authors: Belli L,Magistretti G,Puricelli GP,Damiani G,Colombo E,Cornalba GP

    更新日期:1997-01-01 00:00:00

  • Dual-energy computed tomography in acute ischemic stroke: state-of-the-art.

    abstract::Dual-energy computed tomography (DECT) allows distinguishing between tissues with similar X-ray attenuation but different atomic numbers. Recent studies demonstrated that this technique has several areas of application in patients with ischemic stroke and a potential impact on patient management. After endovascular st...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-020-07543-9

    authors: Mangesius S,Janjic T,Steiger R,Haider L,Rehwald R,Knoflach M,Widmann G,Gizewski E,Grams A

    更新日期:2020-12-14 00:00:00

  • Advances in ultrasound.

    abstract::Significant advances have been recently introduced into various fields of technology, taking advantage of the use of new piezoelectric materials and the large diffusion of broadband transducers. Various types of modulation may be applied to the pulse characteristics, using single pulse, multipulse or multiline techniq...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-001-1185-1

    authors: Claudon M,Tranquart F,Evans DH,Lefèvre F,Correas M

    更新日期:2002-01-01 00:00:00

  • A pregnant lady with intermittent vaginal bleeding (2007: 3b). Placenta percreta.

    abstract::Placenta percreta is a potentially life-threatening complication of pregnancy, which is increasing in incidence. Ante-natal diagnosis with ultrasound and magnetic resonance imaging aids the obstetric team in planning further management. We present a case of placenta percreta with imaging and a brief review of the lite...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0498-5

    authors: Koo BC,Sala E,Hackett GA,Shaw AS

    更新日期:2007-06-01 00:00:00

  • European society of urogenital radiology (ESUR) guidelines: MR imaging of pelvic endometriosis.

    abstract::Endometriosis is a common gynaecological condition of unknown aetiology that primarily affects women of reproductive age. The accepted first-line imaging modality is pelvic ultrasound. However, magnetic resonance imaging (MRI) is increasingly performed as an additional investigation in complex cases and for surgical p...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4673-z

    authors: Bazot M,Bharwani N,Huchon C,Kinkel K,Cunha TM,Guerra A,Manganaro L,Buñesch L,Kido A,Togashi K,Thomassin-Naggara I,Rockall AG

    更新日期:2017-07-01 00:00:00

  • Hemodynamic effects of decompressive craniotomy in MCA infarction: evaluation with perfusion CT.

    abstract::Decompressive craniotomy in hemispheric infarction has been reported to reduce mortality and improve outcome. Identifying tissue at risk and monitoring the benefit of craniotomy is hardly practical and has not been reported thus far. Perfusion CT was applied before and immediately after decompressive craniotomy in a p...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1656-z

    authors: Bendszus M,Müllges W,Goldbrunner R,Weigand A,Solymosi L

    更新日期:2003-08-01 00:00:00

  • Small peripheral lung carcinomas with five-year post-surgical follow-up: assessment by semi-automated volumetric measurement of tumour size, CT value and growth rate on TSCT.

    abstract:OBJECTIVES:To retrospectively assess the utility of semi-automated measurements by stratification of CT values of tumour size, CT value and doubling time (DT) using thin-section computed tomography (CT) images. The post-surgical outcomes of favourable and problematic tumours (more advanced p stage than IA, post-surgica...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-011-2241-0

    authors: Sone S,Hanaoka T,Ogata H,Takayama F,Watanabe T,Haniuda M,Kaneko K,Kondo R,Yoshida K,Honda T

    更新日期:2012-01-01 00:00:00

  • Automated CT volumetry of pulmonary metastases: the effect of a reduced growth threshold and target lesion number on the reliability of therapy response assessment using RECIST criteria.

    abstract::The purpose of this study was to evaluate the reproducibility of CT-volumetric tumour response assessment of pulmonary metastasis using variable volume change thresholds (VCT) and target lesions with response evaluation criteria in solid tumours (RECIST). Fifty consecutive patients with pulmonary metastases undergoing...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0642-x

    authors: Marten K,Auer F,Schmidt S,Rummeny EJ,Engelke C

    更新日期:2007-10-01 00:00:00

  • Neurilemoma of the renal capsule: MR imaging and pathologic correlation.

    abstract::We report a case of neurilemoma arising from the renal capsule. Renal neurilemoma is an especially rare tumor, with only 15 cases previously reported. We attempted to correlate MR findings with microscopic components of the tumor. On T2-weighted images the solid part of the tumor was heterogeneous hyperintense. The MR...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000767

    authors: Tsurusaki M,Mimura F,Yasui N,Minayoshi K,Sugimura K

    更新日期:2001-01-01 00:00:00

  • European Society of Gastrointestinal and Abdominal Radiology (ESGAR): consensus statement on CT colonography.

    abstract::Rapid clinical dissemination of CT colonography (CTC) is occurring in parallel with continued research into technique optimisation and diagnostic performance. A need exists therefore for current guidance as to basic prerequisites for effective clinical implementation. A questionnaire detailing CTC technique, analysis,...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0407-y

    authors: Taylor SA,Laghi A,Lefere P,Halligan S,Stoker J

    更新日期:2007-02-01 00:00:00

  • Magnetic resonance imaging of extrahepatic bile duct disruption.

    abstract::Blunt injury of the extrahepatic bile duct is rare and hence a large series of scientific study of its MRI is difficult to perform. We present the MRI and MR cholangiography of a case of blunt extrahepatic bile duct injury proven at surgery. The diagnosis could be established based on MRI findings of an abrupt taperin...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1296-8

    authors: Wong YC,Wang LJ,Chen RJ,Chen CJ

    更新日期:2002-10-01 00:00:00

  • Asbestos Surveillance Program Aachen (ASPA): initial results from baseline screening for lung cancer in asbestos-exposed high-risk individuals using low-dose multidetector-row CT.

    abstract::The purpose of this study was to assess the prevalence of lung cancer in a high-risk asbestos-exposed cohort using low-dose MDCT. Of a population of 5,389 former power-plant workers, 316 were characterized as individuals at highest risk for lung cancer according to a lung-cancer risk model including age, asbestos expo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0426-8

    authors: Das M,Mühlenbruch G,Mahnken AH,Hering KG,Sirbu H,Zschiesche W,Knoll L,Felten MK,Kraus T,Günther RW,Wildberger JE

    更新日期:2007-05-01 00:00:00

  • Comparison of three multichannel transmit/receive radiofrequency coil configurations for anatomic and functional cardiac MRI at 7.0T: implications for clinical imaging.

    abstract:OBJECTIVES:To implement, examine, and compare three multichannel transmit/receive coil configurations for cardiovascular MR (CMR) at 7T. METHODS:Three radiofrequency transmit-receive (TX/RX) coils with 4-, 8-, and 16-coil elements were used. Ten healthy volunteers (seven males, age 28 ± 4 years) underwent CMR at 7T. F...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2487-1

    authors: Winter L,Kellman P,Renz W,Gräßl A,Hezel F,Thalhammer C,von Knobelsdorff-Brenkenhoff F,Tkachenko V,Schulz-Menger J,Niendorf T

    更新日期:2012-10-01 00:00:00

  • The efficiency of acoustic radiation force impulse imaging for the staging of liver fibrosis: a meta-analysis.

    abstract:OBJECTIVES:Acoustic radiation force impulse (ARFI) imaging is an ultrasound-based elastography method that is integrated into a conventional ultrasound machine. A meta-analysis based on original and abstract publications was performed to evaluate the overall performance of ARFI for the diagnosis of liver fibrosis. MET...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析,评审

    doi:10.1007/s00330-013-2927-6

    authors: Nierhoff J,Chávez Ortiz AA,Herrmann E,Zeuzem S,Friedrich-Rust M

    更新日期:2013-11-01 00:00:00

  • A rational approach to dose reduction in CT: individualized scan protocols.

    abstract::The aim of this study was to demonstrate that dose reduction and constant image quality can be achieved by adjusting X-ray dose to patient size. To establish the relation between patient size, image quality and dose we scanned 19 patients with reduced dose. Image noise was measured. Four radiologists scored image qual...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300101039

    authors: Wilting JE,Zwartkruis A,van Leeuwen MS,Timmer J,Kamphuis AG,Feldberg M

    更新日期:2001-01-01 00:00:00

  • Combining anatomy and function: the path to true image fusion.

    abstract::Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localiza...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300101007

    authors: Townsend DW,Cherry SR

    更新日期:2001-01-01 00:00:00

  • Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT.

    abstract:OBJECTIVES:Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calci...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4675-x

    authors: Yunaga H,Ohta Y,Kaetsu Y,Kitao S,Watanabe T,Furuse Y,Yamamoto K,Ogawa T

    更新日期:2017-07-01 00:00:00

  • CT measurement of coronary calcium mass: impact on global cardiac risk assessment.

    abstract::Coronary calcium mass percentiles can be derived from electron beam CT as well as from multidetector-row CT of all manufacturers. Coronary calcium mass may serve as a more individualized substitute for age for cardiac risk stratification. The aim was to investigate the potential impact of CT coronary calcium mass quan...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2528-5

    authors: Becker CR,Majeed A,Crispin A,Knez A,Schoepf UJ,Boekstegers P,Steinbeck G,Reiser MF

    更新日期:2005-01-01 00:00:00

  • Effect of inspiration on airway dimensions measured in maximal inspiration CT images of subjects without airflow limitation.

    abstract:OBJECTIVES:To study the effect of inspiration on airway dimensions measured in voluntary inspiration breath-hold examinations. METHODS:961 subjects with normal spirometry were selected from the Danish Lung Cancer Screening Trial. Subjects were examined annually for five years with low-dose CT. Automated software was u...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1007/s00330-014-3261-3

    authors: Petersen J,Wille MM,Rakêt LL,Feragen A,Pedersen JH,Nielsen M,Dirksen A,de Bruijne M

    更新日期:2014-09-01 00:00:00

  • Spiral CT pneumocolon: applications, status and limitations.

    abstract::CT pneumocolon is a promising new technique in the diagnosis and management of colon pathology. CT pneumocolon can detect (sensitivity >95%) and stage (accuracy 79%) colorectal cancer and is very accurate in the differentiation of malignant from benign colonic pathologies. It has excellent detection rates for polyps >...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300100890

    authors: Harvey CJ,Renfrew I,Taylor S,Gillams AR,Lees WR

    更新日期:2001-01-01 00:00:00

  • Future prospects for SonoVue and CPS.

    abstract::Though long considered unlikely because of the resonance pattern of agents such as SonoVue, high frequency applications for small parts and intracavitary applications now seem very promising. Excellent non-linear signals can be obtained at 7 MHz and higher using recently developed CPS software, and preliminary results...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s10406-004-0084-3

    authors: Cosgrove D

    更新日期:2004-10-01 00:00:00

  • A "one-stop-shop" 4D CTA protocol using 320-row CT for advanced imaging in acute ischemic stroke: a technical note.

    abstract::This technical note describes a novel CT scan protocol that includes a non-enhanced CT, dynamic CTA, and perfusion of the whole brain and CTA of the carotid arteries using a 320-row area detector CT scanner, with a unique contrast injection and acceptable radiation exposure dose in patients presenting with acute ische...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06041-x

    authors: Ognard J,Dissaux B,Haioun K,Nonent M,Gentric JC,Ben Salem D

    更新日期:2019-09-01 00:00:00

  • Effectiveness of a three-dimensional dual gradient echo two-point Dixon technique for the characterization of adrenal lesions at 3 Tesla.

    abstract:OBJECTIVE:To compare the sensitivity, specificity, and diagnostic accuracy of fat-only datasets reconstructed using a two-point Dixon technique, with corresponding opposed-phase (OP) and in-phase (IP) datasets for characterization of adrenal lesions at 3 Tesla (T). METHODS:Fifty-nine patients (21 male, 38 female) with...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2244-x

    authors: Marin D,Dale BM,Bashir MR,Ziemlewicz TJ,Ringe KI,Boll DT,Merkle EM

    更新日期:2012-01-01 00:00:00