Abstract:
OBJECTIVES:To implement, examine, and compare three multichannel transmit/receive coil configurations for cardiovascular MR (CMR) at 7T. METHODS:Three radiofrequency transmit-receive (TX/RX) coils with 4-, 8-, and 16-coil elements were used. Ten healthy volunteers (seven males, age 28 ± 4 years) underwent CMR at 7T. For all three RX/TX coils, 2D CINE FLASH images of the heart were acquired. Cardiac chamber quantification, signal-to-noise ratio (SNR) analysis, parallel imaging performance assessment, and image quality scoring were performed. RESULTS:Mean total examination time was 29 ± 5 min. All images obtained with the 8- and 16-channel coils were diagnostic. No significant difference in ejection fraction (EF) (P > 0.09) or left ventricular mass (LVM) (P > 0.31) was observed between the coils. The 8- and 16-channel arrays yielded a higher mean SNR in the septum versus the 4-channel coil. The lowest geometry factors were found for the 16-channel coil (mean ± SD 2.3 ± 0.5 for R = 4). Image quality was rated significantly higher (P < 0.04) for the 16-channel coil versus the 8- and 4-channel coils. CONCLUSIONS:All three coil configurations are suitable for CMR at 7.0T under routine circumstances. A larger number of coil elements enhances image quality and parallel imaging performance but does not impact the accuracy of cardiac chamber quantification. KEY POINTS :• Cardiac chamber quantification using 7.0T magnetic resonance imaging is feasible. • Examination times for cardiac chamber quantification at 7.0T match current clinical practice. • Multichannel transceiver RF technology facilitates improved image quality and parallel imaging performance. • Increasing the number of RF channels does not influence cardiac chamber quantification.
journal_name
Eur Radioljournal_title
European radiologyauthors
Winter L,Kellman P,Renz W,Gräßl A,Hezel F,Thalhammer C,von Knobelsdorff-Brenkenhoff F,Tkachenko V,Schulz-Menger J,Niendorf Tdoi
10.1007/s00330-012-2487-1subject
Has Abstractpub_date
2012-10-01 00:00:00pages
2211-20issue
10eissn
0938-7994issn
1432-1084journal_volume
22pub_type
杂志文章abstract:PURPOSE:To assess the role of the MR radiomic signature in preoperative prediction of lymph node (LN) metastasis in patients with esophageal cancer (EC). PATIENTS AND METHODS:A total of 181 EC patients were enrolled in this study between April 2015 and September 2017. Their LN metastases were pathologically confirmed....
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5583-z
更新日期:2019-02-01 00:00:00
abstract:OBJECTIVE:To develop a classification system using imaging features to interpret breast non-mass lesions (NMLs) detected on US and to stratify their cancer risk. METHODS:This retrospective study included 715 patients with 715 breast NMLs detected on breast US from 2012 to 2016. Each patient underwent mammography at th...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07168-y
更新日期:2020-09-04 00:00:00
abstract:OBJECTIVES:To implement a novel voxel-based technique to identify statistically significant local cartilage deformation and analyze in-vivo topographic knee cartilage deformation patterns using a voxel-based thickness map approach for high-flexion postures. METHODS:Sagittal 3T 3D-T1w-FLASH-WE-sequences of 10 healthy k...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-014-3545-7
更新日期:2015-06-01 00:00:00
abstract::The aim of this preliminary study was to retrospectively evaluate the usefulness of high b-value diffusion-weighted MR imaging (DWI) in the detection of gallbladder carcinoma. Fifteen patients with gallbladder carcinoma and 14 other patients were included in this study. All patients and subjects underwent DWI, and ima...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1322-9
更新日期:2009-07-01 00:00:00
abstract::The aim of this study was to evaluate the feasibility of coaxial approach in difficult-to-cross lesions in patients with failed percutaneous transluminal renal angioplasty by conventional over-the-wire exchange technique. Twelve stenoses in 10 patients (six women and four men; age range 19 +/- 7 years) with uncontroll...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050889
更新日期:1999-01-01 00:00:00
abstract::We describe the pace of recruitment of iron-oxide-labeled macrophages to the site of different stages of infection by in vivo magnetic resonance (MR) imaging. Peritoneal macrophages were labeled with superparamagnetic iron oxide ex vivo and administered through the tail vein 6 (acute) or 48 (subacute) h after bacteria...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-008-0975-0
更新日期:2008-10-01 00:00:00
abstract::Placenta percreta is a potentially life-threatening complication of pregnancy, which is increasing in incidence. Ante-natal diagnosis with ultrasound and magnetic resonance imaging aids the obstetric team in planning further management. We present a case of placenta percreta with imaging and a brief review of the lite...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-006-0498-5
更新日期:2007-06-01 00:00:00
abstract::Modern liver imaging of cancer patients requires an imaging modality that is not only highly sensitive in detecting lesions but also provides reliable characterisation of lesions and thus allows differentiation of metastases from frequently found benign lesions. Conventional ultrasound (US) has a relatively poor sensi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s10406-004-0088-z
更新日期:2004-10-01 00:00:00
abstract:OBJECTIVE:To investigate the value of histogram analysis of diffusion kurtosis imaging (DKI) maps in the evaluation of glioma grading. METHODS:A total of 39 glioma patients who underwent preoperative magnetic resonance imaging (MRI) were classified into low-grade (13 cases) and high-grade (26 cases) glioma groups. Par...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-5108-1
更新日期:2018-04-01 00:00:00
abstract:OBJECTIVES:To determine whether there is a difference in frequency and clinical relevance of incidental findings detected by total-body computed tomography scanning (TBCT) compared to those by the standard work-up (STWU) with selective computed tomography (CT) scanning. METHODS:Trauma patients from five trauma centres...
journal_title:European radiology
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1007/s00330-016-4598-6
更新日期:2017-06-01 00:00:00
abstract::A novel ultrasonic imaging method, wideband harmonic imaging, for nonlinear imaging of microbubble contrast agents is evaluated. In wideband harmonic mode, two pulses of alternate phase are send out. The image is then processed from the sum of both pulses, resulting in an image of nonlinear scatterers such as microbub...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/pl00014075
更新日期:1999-01-01 00:00:00
abstract:OBJECTIVE:To investigate the incidence rate, time-to-onset and recovery, MRI morphology and occurrence of insufficiency fractures in radiation-induced changes in the sacrum following pelvic radiotherapy. MATERIAL AND METHODS:410 patients with pelvic malignancies treated with radiotherapy were reviewed. Follow-up was 1...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5325-2
更新日期:2018-08-01 00:00:00
abstract::To compare the diagnostic value of whole-body MRI versus radiological skeletal survey (RSS) in staging patients with plasma cell neoplasms (PCN) and to evaluate the possible therapeutic impact of the replacement of RSS by whole-body MRI. Fifty-four patients with PCN [multiple myeloma (MM), n=47; monoclonal gammopathy ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-005-0055-7
更新日期:2006-05-01 00:00:00
abstract:OBJECTIVES:To determine whether liver function as determined by indocyanine green (ICG) clearance can be estimated quantitatively from hepatic magnetic resonance (MR) relaxometry with gadoxetic acid (Gd-EOB-DTPA). METHODS:One hundred and seven patients underwent an ICG clearance test and Gd-EOB-DTPA-enhanced MRI, incl...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3919-5
更新日期:2016-04-01 00:00:00
abstract::The aim of this study was to depict and characterize inflammatory soft tissue proliferations caused by rheumatoid arthritis (RA) in the craniocervical region by unenhanced and contrast-enhanced CT. Computed tomography of the craniocervical region was performed in 35 patients in the axial plane before and after the i.v...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300000433
更新日期:2000-01-01 00:00:00
abstract::The purpose of this study was to compare moving-table three-dimensional contrast-enhanced magnetic resonance angiography (CE MRA), using 1.0-mol gadobutrol, with intra-arterial digital subtraction angiography (i.a. DSA) for evaluation of pelvic and peripheral arteries in patients with peripheral arterial occlusive dis...
journal_title:European radiology
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1007/s00330-003-1844-5
更新日期:2003-09-01 00:00:00
abstract::Ultrasound has emerged as the primary imaging modality in conditions where either renal obstruction or renal medical disease is suspected on the basis of clinical and laboratory findings. In urinary tract obstruction, pathophysiologic changes affecting the pressure in the collecting system and kidney perfusion are wel...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s003300101011
更新日期:2001-01-01 00:00:00
abstract:OBJECTIVE:To investigate the intra- and inter-observer reliability and agreement between gray-scale and Doppler ultrasound (US) and contrast-enhanced ultrasound (CEUS) in measuring ablated volume (Va) after radiofrequency ablation (RFA) for benign thyroid nodules. METHODS:A total of 173 patients with 190 benign thyroi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07398-0
更新日期:2020-10-31 00:00:00
abstract:PURPOSE:To determine the utility of stretched exponential diffusion model in characterisation of the water diffusion heterogeneity in different tumour stages of nasopharyngeal carcinoma (NPC). MATERIALS AND METHODS:Fifty patients with newly diagnosed NPC were prospectively recruited. Diffusion-weighted MR imaging was ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-014-3535-9
更新日期:2015-06-01 00:00:00
abstract::The original version of this article, published on 19 August 2016, unfortunately contained a mistake. ...
journal_title:European radiology
pub_type: 已发布勘误
doi:10.1007/s00330-020-06947-x
更新日期:2020-11-01 00:00:00
abstract::The majority of abnormal findings or lesions on T2-weighted fast spin-echo (FSE) magnetic resonance imaging (MRI) are hyperintense due to increased perfusion or fluid content, such as infections, tumours or synovitis. Hypointense lesions on T2-weighted images (both fat-suppressed and non-fat-suppressed) are less commo...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-015-4027-2
更新日期:2016-07-01 00:00:00
abstract:OBJECTIVES:A national study on patient dose values in interventional radiology and cardiology was performed in order to assess current practice in Bulgaria, to estimate the typical patient doses and to propose reference levels for the most common procedures. METHODS:Fifteen units and more than 1,000 cases were include...
journal_title:European radiology
pub_type: 杂志文章,多中心研究
doi:10.1007/s00330-012-2386-5
更新日期:2012-06-01 00:00:00
abstract:OBJECTIVES:To determine if quantitative and qualitative shear wave elastography have roles in evaluating musculoskeletal masses. METHODS:105 consecutive patients, prospectively referred for biopsy within a specialist sarcoma centre, underwent B-mode, quantitative (m/s) and qualitative (colour map) shear wave elastogra...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4427-y
更新日期:2017-02-01 00:00:00
abstract::Lesion area measurement in multiple sclerosis (MS) is one of the key points in evaluating the natural history and in monitoring the efficacy of treatments. This study was performed to check the intra- and inter-observer agreement variability of a locally developed Growing Region Segmentation Software (GRES), comparing...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300100978
更新日期:2002-04-01 00:00:00
abstract:OBJECTIVES:To assess the inhibitory effect of gadoxetate disodium on the transporter system using indocyanine green (ICG). MATERIALS AND METHODS:Groups of six female B6 Albino mice were injected with the test agent (0.62 mmol/kg gadoxetate disodium) or phosphate-buffered saline (control) 10 min before injection of ICG...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5403-5
更新日期:2018-10-01 00:00:00
abstract:OBJECTIVES:To investigate diagnostic accuracy and radiation dose of high-pitch CT coronary artery calcium scoring (CACS) with tin filtration (Sn100kVp) versus standard 120kVp high-pitch acquisition. METHODS:78 patients (58% male, 61.5±9.1 years) were prospectively enrolled. Subjects underwent clinical 120kVp high-pitc...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-5249-2
更新日期:2018-07-01 00:00:00
abstract:OBJECTIVES:To evaluate the longitudinal changes of chest CT findings in patients with chronic hypersensitivity pneumonitis (HP) and identify risk factors for fibrotic progression and acute exacerbation (AE). METHODS:This retrospective study included patients with chronic HP with follow-up CT. Baseline and serial follo...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07469-2
更新日期:2020-11-25 00:00:00
abstract::The objectives of this study were twofold: (a) to assess safety and tolerability of the hepatobiliary MR contrast agent MnDPDP; and (b) to investigate the sensitivity of MnDPDP-enhanced MRI, in comparison with dual-phase spiral CT, in the detection of hepatocellular carcinoma (HCC) in cirrhosis. Fifty patients with li...
journal_title:European radiology
pub_type: 临床试验,杂志文章
doi:10.1007/s003300000564
更新日期:2000-01-01 00:00:00
abstract::The purpose of our study was to investigate whether quantitative diffusion-weighted images (DWI) were useful for monitoring the therapeutic response of primary bone tumors. We encountered 18 osteogenic and Ewing sarcomas. Magnetic resonance (MR) images were performed in all patients before and after therapy. We measur...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-006-0342-y
更新日期:2006-12-01 00:00:00
abstract::A new technique is presented for retrograde urethrography (RGU) using a plastic adjustable clamp. The procedure was performed in 36 patients with suspected urethral stenosis. Mean age was 55.3 years. The device and the procedure are described. All the radiologic examinations of the urethra were carried out successfull...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-002-1662-1
更新日期:2003-06-01 00:00:00