Abstract:
INTRODUCTION:Glycolysis affects glucose determination in vitro. The placement of sample tubes in ice-water slurry with plasma separation within 30 minutes is recommended, or alternatively the use of a glycolysis inhibitor. The aim of our two-steps study was to evaluate which Terumo tube is best for glucose determination in routine clinical setting. MATERIALS AND METHODS:In the first study, blood from 100 volunteers was collected into lithium heparin (LH), NaF/Na heparin (FH) and NaF/citrate buffer/Na2EDTA (FC-Mixture) tubes. LH sample was treated as recommended and considered as reference, while FH and FC-Mixture samples were aliquoted, maintained at room temperature (RT) for 1, 2 and 4 hours; centrifuged and plasma analysed in triplicate. In the second study, samples from 375 volunteers were collected in LH, FH and FC-Mixture tubes and held at RT before centrifugation from 10 to 340 minutes, depending on each laboratory practice. Samples were analysed in one analytical run. RESULTS:In the first study, FH glucose concentrations were 5.15 ± 0.66 mmol/L, 5.05 ± 0.65 mmol/L and 5.00 ± 0.65 mmol/L (P < 0.001) in tubes stored at RT for 1, 2 and 4 hours, respectively. Mean biases in all time points exceeded the analytical goal for desirable bias based on biological variation criteria. FC-Mixture glucose concentrations were 5.48 ± 0.65 mmol/L, 5.46 ± 0.6 mmol/L and 5.46 ± 0.64 mmol/L in tubes stored at RT for 1, 2 and 4 hours, respectively. Mean biases for FC-Mixture glucose in all time points reached optimal analytical goals. In the second study, the biases for LH and FH glucose compared to reference FC-Mixture glucose exceeded the preset analytical goals, regardless of the blood collection to centrifugation time interval. CONCLUSIONS:FC-mixture tubes glucose concentrations were preserved up to 4h storage at RT. We confirmed that NaF alone does not allow immediate glycolysis inhibition in real life pre-centrifugation storage conditions (up to 340 minutes). FC-Mixture should be used exclusively for glucose determination in laboratories unable to implement the recommended blood samples' treatment.
journal_name
Biochem Med (Zagreb)journal_title
Biochemia medicaauthors
Bonetti G,Carta M,Montagnana M,Lo Cascio C,Bonfigli AR,Mosca A,Testa R,Italian joint SIBioC-SIPMeL Study Group on Diabetes Mellitus.doi
10.11613/BM.2016.006subject
Has Abstractpub_date
2016-01-01 00:00:00pages
68-76issue
1eissn
1330-0962issn
1846-7482pii
bm-26-68journal_volume
26pub_type
杂志文章相关文献
Biochemia Medica文献大全abstract:Introduction:Liquid chromatography coupled to atmospheric pressure ionization tandem mass spectrometry (LC-ESI-MS/MS) is currently considered the reference method for quantitative determination of urinary free cortisol (UFC). One of the major drawbacks of this measurement is a particular form of matrix effect, conventi...
journal_title:Biochemia medica
pub_type: 杂志文章,评审
doi:10.11613/BM.2017.031001
更新日期:2017-10-15 00:00:00
abstract:Introduction:Measurement of parathyroid hormone (PTH) is essential in the investigation and management of calcium metabolism disorders. To assess the significance of any assay result when clinical decision making biological variation (BV) of the measurand must be taken into consideration. The aim of the present study i...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2019.030702
更新日期:2019-10-15 00:00:00
abstract:INTRODUCTION:In vitro human diagnostic (IVD) company recalls are a common practice aimed to either minimize a potential error or eliminate an existing failure. In this case report, we aim to provide a critical analysis of a recent IVD recall and to provide a practical framework about what to do when an IVD company reca...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2015.028
更新日期:2015-06-05 00:00:00
abstract::Diagnostic tests are important clinical tools. Bayes' theorem and Bayesian approach are important methods for interpreting test results. The Bayesian factor, the so-called likelihood ratio, has not always been well-understood. In this article, we try to discuss the likelihood ratio and its value for a specific test re...
journal_title:Biochemia medica
pub_type: 杂志文章,评审
doi:10.11613/BM.2019.020101
更新日期:2019-06-15 00:00:00
abstract::Eosinophil cationic protein (ECP) is a heterogeneous molecule originating from activated eosinophil granulocytes. Biological activity and the cellular content of ECP are determined by genetic and posttranslational factors. Several single nucleotide polymorphisms (SNPs) in human ECP gene (RNASE3) have been described so...
journal_title:Biochemia medica
pub_type: 杂志文章,评审
doi:10.11613/bm.2011.019
更新日期:2011-01-01 00:00:00
abstract:Introduction:The measurement of β-hydroxybutyrate (βOHB) concentrations is a corner stone of the diagnosis of diabetic ketoacidosis and other ketonic states. The aim of this study was to perform a validation of a peripheral blood βOHB assay (Randox) on a Roche cobas c502 analyser and to establish a βOHB reference range...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2020.010707
更新日期:2020-02-15 00:00:00
abstract::Urinary angiotensin converting enzyme 2 (ACE2) is significantly increased in diabetes and diabetic nephropathy. While studies on its clinical significance are still underway, its urinary expression, association with metabolic and renal parameters has been in the recent past considerably studied. The recent studies hav...
journal_title:Biochemia medica
pub_type: 杂志文章,评审
doi:10.11613/BM.2019.010501
更新日期:2019-02-15 00:00:00
abstract:INTRODUCTION:Urinary tract infection (UTI) is one of the most common bacterial infectious diseases in children. The aim of this study was to determine the total prooxidant and antioxidant capacity of children with UTI, as well as changes of oxidative status parameters according to acute inflammation persistence and acu...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2014.029
更新日期:2014-01-01 00:00:00
abstract:INTRODUCTION:Early identification and management of chronic kidney disease (CKD) is highly cost-effective and can reduce the risk of kidney failure progression and cardiovascular disease. In 2014, the Joint Croatian Working Group (JCWG) for laboratory diagnostic of CKD on the behalf of Croatian society of medical bioch...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2015.009
更新日期:2015-01-01 00:00:00
abstract:INTRODUCTION:ISO 15189 was a new standard published in 2003 for accrediting medical laboratories. We believe that some requirements of the ISO 15189 standard are especially difficult to meet for majority of laboratories. The aim of this article was to present the frequency of nonconformities to requirements of the ISO ...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/bm.2012.027
更新日期:2012-01-01 00:00:00
abstract:INTRODUCTION:Duplicate measurements can be used to describe the performance and analytical robustness of assays and to identify outliers. We performed about 235,000 duplicate measurements of nine routinely measured quantities and evaluated the observed differences between the replicates to develop new markers for analy...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2017.021
更新日期:2017-02-15 00:00:00
abstract::Reliable procedures are needed to quantify the performance of instruments and methods in order to increase the quality in clinical laboratories. The Sigma metrics serves that purpose, and in the present study, the current methods for the calculation of the Sigma metrics are critically evaluated. Although the conventio...
journal_title:Biochemia medica
pub_type: 杂志文章,评审
doi:10.11613/BM.2018.020503
更新日期:2018-06-15 00:00:00
abstract:Introduction:The evaluation of patients with suspected appendicitis strives to identify all patients with presenting symptoms while minimizing negative appendectomy rate. The aim of the study was to identify the optimal combination of clinical and laboratory parameters that should facilitate the emergency department su...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2018.030712
更新日期:2018-10-15 00:00:00
abstract::The kappa statistic is frequently used to test interrater reliability. The importance of rater reliability lies in the fact that it represents the extent to which the data collected in the study are correct representations of the variables measured. Measurement of the extent to which data collectors (raters) assign th...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:
更新日期:2012-01-01 00:00:00
abstract::This systematic review presents the latest trends in salivary research and its applications in health and disease. Among the large number of analytes present in saliva, many are affected by diverse physiological and pathological conditions. Further, the non-invasive, easy and cost-effective collection methods prompt a...
journal_title:Biochemia medica
pub_type: 杂志文章,评审
doi:10.11613/BM.2015.018
更新日期:2015-06-05 00:00:00
abstract:INTRODUCTION:Our aim was to investigate if: (a) authors of Biochemia Medica meet authorship criteria given by International Committee of Medical Journal Editors (ICMJE), (b) authorship violations are more frequent in submissions containing some type of scientific misconduct. MATERIALS AND METHODS:Self-reported authors...
journal_title:Biochemia medica
pub_type: 杂志文章,评审
doi:10.11613/BM.2015.033
更新日期:2015-10-15 00:00:00
abstract::Hypothesis testing is a methodological paradigm widely popularized outside the field of pure statistics, and nowadays more or less familiar to the largest part of biomedical researchers. Conversely, the equivalence testing is still somehow obscure and misunderstood, although it represents a conceptual mainstay for som...
journal_title:Biochemia medica
pub_type: 杂志文章,评审
doi:10.11613/BM.2017.001
更新日期:2017-02-15 00:00:00
abstract:INTRODUCTION:The usefulness and cost-effectiveness of routine laboratory preoperative tests (POTs) have been challenged recently. In fact, the American Society of Anesthesiologists (ASA) Task Force has stated that test results obtained from the medical record within 6 months of surgery generally are mostly acceptable. ...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2017.030902
更新日期:2017-10-15 00:00:00
abstract:INTRODUCTION:Acute kidney injury (AKI) is common in neonatal intensive care units (NICU). In recent years, every effort is made for early detection of AKI. Our hypothesis was that serum neutrophil gelatinase-associated lipocalin (sNGAL) may be a reliable screening test for early diagnosis of AKI in premature neonates a...
journal_title:Biochemia medica
pub_type: 临床试验,杂志文章
doi:10.11613/BM.2015.046
更新日期:2015-10-15 00:00:00
abstract:Introduction:Autovalidation (AV) is an algorithm based on predefined rules designed, among others, to automate and standardize the postanalytical phase of laboratory work. The aim of this study was to examine the overall opinion of Croatian medical biochemistry laboratories regarding various aspects of AV. Material an...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2020.020702
更新日期:2020-06-15 00:00:00
abstract::In this paper we would like to briefly introduce readers to the situation in the field of laboratory medicine in Bosnia and Herzegovina, with a focus on training in the field of medical biochemistry. As in some of neighboring countries, term Medical biochemist is the usual name for the Clinical biochemist or Clinical ...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:
更新日期:2011-01-01 00:00:00
abstract:INTRODUCTION:The opening of research data is emerging thanks to the increasing possibilities of digital technology. The opening of clinical trial (CT) data is a part of this process, expected to have positive scientific, ethical, health, and economic impacts thus contributing to research integrity. The January 2016 pro...
journal_title:Biochemia medica
pub_type: 杂志文章,评审
doi:10.11613/BM.2016.035
更新日期:2016-10-15 00:00:00
abstract::The Chi-square statistic is a non-parametric (distribution free) tool designed to analyze group differences when the dependent variable is measured at a nominal level. Like all non-parametric statistics, the Chi-square is robust with respect to the distribution of the data. Specifically, it does not require equality o...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/bm.2013.018
更新日期:2013-01-01 00:00:00
abstract:Introduction:In recent years, Six Sigma metrics has became the hotspot in all trades and professions, which contributes a general procedure to explain the performance on sigma scale. Nowadays, many large companies, such as General Healthcare, Siemens, etc., have applied Six Sigma to clinical medicine and achieved satis...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2018.020904
更新日期:2018-06-15 00:00:00
abstract::Peer review is widely used system for evaluating manuscripts prior to publication. It has been and still is widely used tool for making justified and fair editorial decision. However, the evidence of its efficacy is limited and it has been criticized to be time-consuming, biased, inconsistent, conservative, and open t...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2014.034
更新日期:2014-10-15 00:00:00
abstract::Authorship problems are deep-rooted in the field of science communication. Some of these relate to lack of specific journal instructions. For decades, experts in journal editing and publishing have been exploring the authorship criteria and contributions deserving either co-authorship or acknowledgment. The issue of i...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2016.017
更新日期:2016-01-01 00:00:00
abstract:Introduction:Severe hyperkalaemia is a serious medical condition requiring immediate medical attention. Before medical treatment is started, pseudohyperkalaemia has to be ruled out. Case description:A 10-month old infant presented to the emergency department with fever and coughing since 1 week. Routine venous blood t...
journal_title:Biochemia medica
pub_type:
doi:10.11613/BM.2020.021004
更新日期:2020-06-15 00:00:00
abstract::Preanalytical phase is the most vulnerable part of the total testing process and is considered to be among the greatest challenges to the laboratory professionals. However, preanalytical activities, management of unsuitable specimens and reporting policies are not fully standardized, nor harmonized worldwide. Several ...
journal_title:Biochemia medica
pub_type: 社论
doi:10.11613/bm.2012.017
更新日期:2012-01-01 00:00:00
abstract:Introduction:It is often quoted that 70% of clinical decisions are based on laboratory results, but the evidence to substantiate this claim is lacking. Since clinical guidelines aim to document best-practice decision making for specific disease conditions, inclusion of any laboratory test means that the best available ...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2021.010703
更新日期:2021-02-15 00:00:00
abstract:Introduction:Reference intervals (RIs) for complement assays in EDTA plasma samples have not previously been published. The objectives of the present study were to validate and/or determine RIs for classical pathway (CP50) activity and C3c, C4 and C1 inhibitor protein (C1INH) assays and to assess the need for age-speci...
journal_title:Biochemia medica
pub_type: 杂志文章
doi:10.11613/BM.2019.030707
更新日期:2019-10-15 00:00:00