Calcineurin activity assay measurement by liquid chromatography-tandem mass spectrometry in the multiple reaction monitoring mode.

Abstract:

BACKGROUND:Blood concentrations of the calcineurin inhibitors (CNIs) cyclosporine and tacrolimus are currently measured to monitor immunosuppression in transplant patients. The measurement of calcineurin (CN) phosphatase activity has been proposed as a complementary pharmacodynamic approach. However, determining CN activity with current methods is not practical. We developed a new method amenable to routine use. METHODS:Using liquid chromatography-multiple reaction monitoring mass spectrometry (LC-MRM-MS), we quantified CN activity by measuring the dephosphorylation of a synthetic phosphopeptide substrate. A stable isotope analog of the product peptide served as internal standard, and a novel inhibitor cocktail minimized dephosphorylation by other major serine/threonine phosphatases. The assay was used to determine CN activity in peripheral blood mononuclear cells (PBMCs) isolated from 20 CNI-treated kidney transplant patients and 9 healthy volunteers. RESULTS:Linearity was observed from 0.16 to 2.5 μmol/L of product peptide, with accuracy in the 15% tolerance range. Intraassay and interassay recoveries were 100.6 (9.6) and 100 (7.5), respectively. Michaelis-Menten kinetics for purified CN were Km = 10.7 (1.6) μmol/L, Vmax = 2.8 (0.3) μmol/min · mg, and for Jurkat lysate, Km = 182.2 (118.0) μmol/L, Vmax = 0.013 (0.006) μmol/min · mg. PBMC CN activity was successfully measured in a single tube with an inhibitor cocktail. CONCLUSIONS:Because LC-MRM-MS is commonly used in routine clinical dosage of drugs, this CN activity assay could be applied, with parallel blood drug concentration monitoring, to a large panel of patients to reevaluate the validity of PBMC CN activity monitoring.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Carr L,Gagez AL,Essig M,Sauvage FL,Marquet P,Gastinel LN

doi

10.1373/clinchem.2013.213264

subject

Has Abstract

pub_date

2014-02-01 00:00:00

pages

353-60

issue

2

eissn

0009-9147

issn

1530-8561

pii

clinchem.2013.213264

journal_volume

60

pub_type

杂志文章
  • Data Normalization Strategies for MicroRNA Quantification.

    abstract:BACKGROUND:Different technologies, such as quantitative real-time PCR or microarrays, have been developed to measure microRNA (miRNA) expression levels. Quantification of miRNA transcripts implicates data normalization using endogenous and exogenous reference genes for data correction. However, there is no consensus ab...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2015.239459

    authors: Schwarzenbach H,da Silva AM,Calin G,Pantel K

    更新日期:2015-11-01 00:00:00

  • Determination of erythrocyte folate by competitive protein binding assay preceded by extraction.

    abstract::Determination of the concentration of erythrocyte folate by means of competitive protein binding assay critically depends on the extraction procedure applied. Results will be influenced by variable factors such as the in vitro age of the blood samples, the degree of hemolysis, the presence of ascorbic acid, and the pH...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mortensen E

    更新日期:1976-07-01 00:00:00

  • Abbott radiative energy attenuation method for quantifying ethanol evaluated and compared with gas-liquid chromatography and the Du Pont aca.

    abstract::Quantification of ethanol by a radiative energy attenuation (REA) technique was evaluated and compared with results by gas-liquid chromatography (GLC) and by the Du Pont aca. Within-assay CVs were less than 5.5%. Between-assay CVs ranged from 1.9% to 6.0% for serum and blood controls at concentrations of 0.5, 1.0, and...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cary PL,Whitter PD,Johnson CA

    更新日期:1984-11-01 00:00:00

  • A fully automated solid-phase radioimmunoassay for triiodothyronine.

    abstract::We report the first solid-phase radioimmunoassay for triiodothyronine with use of antibody-coated tubes, which is designed specifically for the fully automated radioimmunoassay instrument, Micromedic Systems' "Concept 4 Automatic Radioassay." Antisera to triiodothyropropionic acid/bovine serum albumin were raised in r...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rugg NE,Hasler MJ,Bjornsen RE,Painter K

    更新日期:1977-05-01 00:00:00

  • Laboratory computing--process and information management supporting high-quality, cost-effective healthcare.

    abstract::One currently observes many healthcare institutions rushing to reengineer and install information systems with the expectation of achieving enhanced efficiency, competitiveness, and, it is hoped, higher patient satisfaction resulting from timely, high-quality care. Unfortunately, information system concepts, design, a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Buffone GJ,Moreau DR

    更新日期:1995-09-01 00:00:00

  • Elimination of glucose interference and improved precision in a continuous-flow analysis for inulin.

    abstract::A modified fermentation procedure based on one described by Homer Smith in his textbook was used to eliminate glucose interference in the automated detrmination of inulin. The manifold of Fjeldbo and Stamey [J. Lab. Clin. Med. 72, 353 (1968)] was modified to enable us to insert the fermentation procedure without sacri...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Torelli JA,Middleton B,Stein RM

    更新日期:1977-07-01 00:00:00

  • Time-course of cigarette smoke contamination of clinical hydrogen breath-analysis tests.

    abstract::The time-course of the contamination of exogenous hydrogen from cigarette smoke on postprandial breath hydrogen concentration was evaluated in 10 subjects, six regular smokers and four occasional smokers. Breath hydrogen values were determined by gas chromatography 10 min, 5 min, and immediately prior to smoking a fil...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rosenthal A,Solomons NW

    更新日期:1983-11-01 00:00:00

  • Performance evaluation and subsequent clinical experience with the Abbott Automated Architect STAT Troponin-I assay.

    abstract:BACKGROUND:Cardiac troponins are specific biochemical markers of myocardial injury used in the diagnosis of acute myocardial disease and cardiac risk stratification. To avoid misclassification of patients, troponin assays must demonstrate precision at the low end of the measuring range. We report our evaluation of the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.057216

    authors: Lam Q,Black M,Youdell O,Spilsbury H,Schneider HG

    更新日期:2006-02-01 00:00:00

  • A modified radioimmunoassay for 1,25-dihydroxycholecalciferol.

    abstract::A radioimmunoassay for 1,25-dihydroxycholecalciferol which did not cross react with 1,25-dihydroxyergocalciferol is described. IgG fractions were prepared from the serum of rabbits that had been immunized with 1,25-dihydroxycholecalciferol-3-hemisuccinate coupled to bovine albumin. Radioligand binding by the IgG fract...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gray TK,McAdoo T,Pool D,Lester GE,Williams ME,Jones G

    更新日期:1981-03-01 00:00:00

  • Coffee consumption and circulating B-vitamins in healthy middle-aged men and women.

    abstract:BACKGROUND:Coffee consumption has been associated with several risk factors for coronary heart disease, including increased cholesterol, increased blood pressure, and increased plasma total homocysteine (tHcy). tHcy is determined by several B-vitamins. However, reports about the association between coffee intake and B-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.103465

    authors: Ulvik A,Vollset SE,Hoff G,Ueland PM

    更新日期:2008-09-01 00:00:00

  • Serum protein profiles by "high-performance" liquid chromatography with detection at multiple wavelengths.

    abstract::We have separated serum proteins in only 15 min by high-performance liquid chromatography. The identification of several peaks in the chromatographic profile was greatly aided by the use of multiple-wavelength detection. We have found a good correlation between retention times and electrophoretic mobilities. Serum sam...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schlabach TD,Abbott SR

    更新日期:1980-09-01 00:00:00

  • Central role of zinc protoporphyrin in staging iron deficiency.

    abstract::In iron deficiency, zinc protoporphyrin (ZPP) is produced instead of heme, and the ZPP concentration in erythrocytes is increased (normal < or = 40 mumol/mol heme). We investigated the relevance of ZPP for staging iron deficiency. ZPP was determined by hematofluorometry in samples from 103 patients. Nineteen patients ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hastka J,Lasserre JJ,Schwarzbeck A,Hehlmann R

    更新日期:1994-05-01 00:00:00

  • Biological and clinical significance of haptoglobin polymorphism in humans.

    abstract::Haptoglobin is a hemoglobin-binding protein expressed by a genetic polymorphism as three major phenotypes: 1-1, 2-1, and 2-2. Most attention has been paid to determining haptoglobin phenotype as a genetic fingerprint used in forensic medicine. More recently, several functional differences between haptoglobin phenotype...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Langlois MR,Delanghe JR

    更新日期:1996-10-01 00:00:00

  • Novel protein markers of acute coronary syndrome complications in low-risk outpatients: a systematic review of potential use in the emergency department.

    abstract:BACKGROUND:Published literature was systematically reviewed to determine the diagnostic accuracy of new protein markers of acute coronary syndromes (ACS) in symptomatic outpatients at low risk of ACS and related complications comparable to patients evaluated in emergency department chest pain units. METHODS:Studies we...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2005.052456

    authors: Mitchell AM,Brown MD,Menown IB,Kline JA

    更新日期:2005-11-01 00:00:00

  • Sandwich ELISA Using a Mouse/Human Chimeric CSLEX-1 Antibody.

    abstract:BACKGROUND:An assay using a mouse antisialyl Lewis X (sLeX) antibody (CSLEX-1) is used clinically for screening and monitoring patients with breast cancer in Japan. However, the IgM isoform of CSLEX-1 is not preferred for the assay because the bulkiness of IgM generally causes poor accessibility to the antigen. To solv...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.260968

    authors: Yamashita J,Kobayashi I,Tatematsu K,Sezutsu H,Noda K,Ishihara H

    更新日期:2016-11-01 00:00:00

  • Basal and stimulated calcitonin and procalcitonin by various assays in patients with and without medullary thyroid cancer.

    abstract:BACKGROUND:Calcitonin (CT) is a sensitive marker for evaluation of medullary thyroid cancer (MTC). However, CT measurement can vary with assay- and nonassay-dependent factors, and procalcitonin (PCT) measurement has been proposed for evaluating questionable increases in CT. METHODS:We tested 2 fully automated CT assay...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.151688

    authors: Kratzsch J,Petzold A,Raue F,Reinhardt W,Bröcker-Preuss M,Görges R,Mann K,Karges W,Morgenthaler N,Luster M,Reiners C,Thiery J,Dralle H,Fuhrer D

    更新日期:2011-03-01 00:00:00

  • Evaluation of two digoxin radioimmunoassay procedures in which 125I-labeled digoxin is used.

    abstract::We present a comparative evaluation of two commercial kits, the "Quantitope" and "GammaCoat," for radioimmunoassay of digoxin in serum. These kits, in which iodine-125 is used as a label, proved to suitable for digoxin assay as determined by their reproducibility, sensitivity, precision, and a regression analysis. Hem...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kuczala ZJ,Ahluwalia GS

    更新日期:1976-02-01 00:00:00

  • Stability of NADPH: effect of various factors on the kinetics of degradation.

    abstract::Seeking to minimize degradation of NADPH during storage, reagent preparation, and assays, we investigated the effects of pH, temperature, and ionic strength as well as the effects of phosphate and acetate. NADH was also included for comparison. Our results indicate that the rate of degradation of NADPH is proportional...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wu JT,Wu LH,Knight JA

    更新日期:1986-02-01 00:00:00

  • Quality assurance, accreditation, and certification: needs and possibilities.

    abstract::Demonstrable quality of laboratory services entails two parts. First, one needs a quality policy statement, identification of user needs, choice of measurement procedures, reference measurement system to provide traceability, control materials, and proficiency testing with materials having reference-measurement-assign...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Dybkaer R

    更新日期:1994-07-01 00:00:00

  • Gas-chromatographic determination of mephenytoin and desmethylmephenytoin, after off-column alkylation.

    abstract::We describe a gas-liquid chromatographic method for determining mephenytoin and its active metabolite, desmethylmephenytoin, in human serum. 5-Methyl-5-phenylhydantoin is used as the internal standard. The method involves extraction of the drugs by adsorption onto charcoal and off-column derivatization to their pentyl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Raisys VA,Zebelman AM,MacMillan SF

    更新日期:1979-01-01 00:00:00

  • Detection of Colorectal Cancer in Circulating Cell-Free DNA by Methylated CpG Tandem Amplification and Sequencing.

    abstract:BACKGROUND:Aberrant DNA hypermethylation of CpG islands occurs frequently throughout the genome in human colorectal cancer (CRC). A genome-wide DNA hypermethylation analysis technique using circulating cell-free DNA (cfDNA) is attractive for the noninvasive early detection of CRC and discrimination between CRC and othe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2019.301804

    authors: Li J,Zhou X,Liu X,Ren J,Wang J,Wang W,Zheng Y,Shi X,Sun T,Li Z,Kang A,Tang F,Wen L,Fu W

    更新日期:2019-07-01 00:00:00

  • Comparing multivariate and univariate subject-specific reference regions for blood constituents in healthy persons.

    abstract::We examined the comparative behavior of subject-specific multivariate and univariate reference regions, using both computer-generated data and serial (semi-annual) measurements of selected analytes in subjects from a large health-maintenance program. Univariate studies under both homeostatic and random-walk time-serie...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harris EK,Yasaka T,Horton MR,Shakarji G

    更新日期:1982-03-01 00:00:00

  • An interlaboratory study of measurement of aspartate aminotransferase activity with use of purified enzyme materials.

    abstract::The Center for Disease Control (CDC), the New York State Department of Health (NYSDH), the College of American Pathologists, and 23 manufacturers of diagnostic products participated in an interlaboratory study of aspartate aminotransferase (EC 2.6.1.1) methodologies. Six different lyophilized materials were prepared a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Burtis CA,Sampson EJ,Bayse DD,McKneally SS,Whitner VS

    更新日期:1978-06-01 00:00:00

  • Specific 125I-radioimmunoassay for cholyglycine, a bile acid, in serum.

    abstract::The concentration of the conjugated bile acid, cholylglycine, in serum is a sensitive and specific indicator of hepatic function. We describe a convenient, specific, and precise radioimmunoassay for cholylglycine, in which 125I-labeled cholylglycyltyrosine is used as tracer. In addition, a blocking agent in the buffer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Miller P,Weiss S,Cornell M,Dockery J

    更新日期:1981-10-01 00:00:00

  • Four methods for glucose assay compared for various glucose concentrations and under different clinical conditions.

    abstract::Glucose was measured by the ferricyanide, the Beckman glucose oxidase, and the hexokinase procedures in 228 plasma samples taken during standard oral glucose-tolerance tests in 17 normal subjects and in 21 chemical diabetics. The neocuproine method was also used to measure glucose concentration in 156 samples (78 befo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Giampietro O,Pilo A,Buzzigoli G,Boni C,Navalesi R

    更新日期:1982-12-01 00:00:00

  • Liquid-chromatographic procedure for tricyclic drugs and their metabolites in plasma.

    abstract::We describe a procedure for determining amitriptyline and imipramine and their active metabolites nortriptyline and desipramine, respectively, at therapeutic concentrations in human plasma by use of liquid chromatography. The drugs are extracted at pH 10.5 into hexane/isoamyl alcohol, which is evaporated and the resid...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vandemark FL,Adams RF,Schmidt GJ

    更新日期:1978-01-01 00:00:00

  • Microscale ultrafiltration technique for determining free drug in 50-microL serum samples.

    abstract::This ultrafiltration technique allows determination of free drug in 50 microL of serum. We ultrafiltered sera containing the following drugs--valproic acid (and its major metabolites), phenobarbital, diazepam, indomethacin, phenytoin, furosemide, and chloramphenicol--using both the commercially available micropartitio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wittfoht W,Duwe K,Kuhnz W,Nau H

    更新日期:1984-06-01 00:00:00

  • A method for direct estimation of imprecision profiles, with reference to immunoassay data.

    abstract::A three-parameter model for directly estimating imprecision profiles from replicated immunoassay results is compared with a six-parameter indirect profile model obtained by the usual method of combining error in the raw response measurements with the slope of the standard curve. Direct estimation is likely to be less ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sadler WA,Smith MH,Legge HM

    更新日期:1988-06-01 00:00:00

  • Quantification of bone alkaline phosphatase in serum by precipitation with wheat-germ lectin: a simplified method and its clinical plausibility.

    abstract::We report an easy, rapid method for quantifying bone isoenzyme of alkaline phosphatase (EC 3.1.3.1., ALP) in serum. The original method described by Rosalki and Ying Foo (Clin Chem 1984;30:1182-6) was somewhat simplified. In contrast to their results, we found that bone ALP is precipitated quantitatively by wheat-germ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Behr W,Barnert J

    更新日期:1986-10-01 00:00:00

  • Primidone analyses: correlation of gas-chromatographic assay with enzyme immunoassay.

    abstract::Serum specimens from patients on primidone therapy were assayed by two currently available procedures: a commercially available enzyme immunoassay (EMIT) and a published gas-chromatographic procedure. Both procedures were done with commercially available materials and equipment. Results by the two procedures agreed we...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sun L,Walwick ER

    更新日期:1976-06-01 00:00:00