Elimination of glucose interference and improved precision in a continuous-flow analysis for inulin.

Abstract:

:A modified fermentation procedure based on one described by Homer Smith in his textbook was used to eliminate glucose interference in the automated detrmination of inulin. The manifold of Fjeldbo and Stamey [J. Lab. Clin. Med. 72, 353 (1968)] was modified to enable us to insert the fermentation procedure without sacrificing precision in continuous-flow analysis for inulin. Analytical recoveries of inulin from plasma and urine with the modified manifold were 100.1 +/- 0.8% (SD) and 99.9 +/- 1.6%. Corresponding recoveries of inulin from specimens of plasma and urine containing 5 g of glucose per liter and treated with yeast were 99.6 +/- 1.5% and 100.0 +/- 1.6%.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Torelli JA,Middleton B,Stein RM

subject

Has Abstract

pub_date

1977-07-01 00:00:00

pages

1324-5

issue

7

eissn

0009-9147

issn

1530-8561

journal_volume

23

pub_type

杂志文章
  • Stabilized analysis of antidepressant drugs by solvent-recycled liquid chromatography: procedure and proposed resolution mechanisms for chromatography.

    abstract::In this efficient extraction and isocratic liquid-chromatographic procedure for measuring eight antidepressant drugs in serum (amoxapine, 8-hydroxyamoxapine, doxepin, desmethyldoxepin, imipramine, desipramine, amitriptyline, and nortriptyline), they are extracted from serum as a group by use of disposable solid-phase ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lensmeyer GL,Evenson MA

    更新日期:1984-11-01 00:00:00

  • Comparison of calculated and measured free thyroid hormones in serum in health and in abnormal states.

    abstract::To evaluate a theoretical model for calculating free thyroid hormones, based on the law of mass action, we compared values for both calculated and measured free thyroxin and free triiodothyronine in a group of normal subjects. To determine whether the concentrations of circulating free hormones were also predictable f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fresco G,Curti G,Biggi A,Fontana B

    更新日期:1982-06-01 00:00:00

  • A fully automated solid-phase radioimmunoassay for triiodothyronine.

    abstract::We report the first solid-phase radioimmunoassay for triiodothyronine with use of antibody-coated tubes, which is designed specifically for the fully automated radioimmunoassay instrument, Micromedic Systems' "Concept 4 Automatic Radioassay." Antisera to triiodothyropropionic acid/bovine serum albumin were raised in r...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rugg NE,Hasler MJ,Bjornsen RE,Painter K

    更新日期:1977-05-01 00:00:00

  • Iron and total iron-binding capacity in serum of patients receiving iron-dextran: Kodak Ektachem methodologies, spectrophotometry, and atomic-absorption spectrometry compared.

    abstract::We compared the analytical performance of the Kodak Ektachem XR700 assays of iron (Fe) and total iron-binding capacity (TIBC) with that of a conventional ferrozine assay (performed with a Cobas-Bio) and occasionally with that of atomic-absorption spectrometry (AAS). The correlation was modest between Kodak and Cobas-B...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vercammen M,Goedhuys W,Boeyckens A,De Roy R,Sennesael J,Sevens C,Gorus F

    更新日期:1990-10-01 00:00:00

  • Serum-constituents analyses: effect of duration and temperature of storage of clotted blood.

    abstract::We studied the effects on 25 analytes of duration of contact of serum with non-anticoagulated blood and of temperature. Serum was separated after blood was allowed to stand, for 0, 2, 4, 6, 8, 24, or 48 h at 4, 23, or 30 degrees C. Results obtained for bilirubin, albumin, zinc sulfate turbidity, thymol turbidity, chol...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ono T,Kitaguchi K,Takehara M,Shiiba M,Hayami K

    更新日期:1981-01-01 00:00:00

  • Relationships between immunogen structure and antisera specificity in the narcotic alkaloid series.

    abstract::We report the production and comparative specificities of antisera raised to different immunogens containing codeine, morphine, and oxycodone. Antisera raised to bovine serum albumin (BSA) conjugates of codeine-6-hemisuccinate, ethylmorphine-6-hemisuccinate, or oxycodone-6-carboxymethyloxime had greatest recognition o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Findlay JW,Butz RF,Jones EC

    更新日期:1981-09-01 00:00:00

  • New reference intervals for thyrotropin and thyroid hormones based on National Academy of Clinical Biochemistry criteria and regular ultrasonography of the thyroid.

    abstract:BACKGROUND:The aim of our present study was to establish new reference intervals for thyrotropin (TSH) and thyroid hormones based on National Academy of Clinical Biochemistry (NACB) criteria and regular thyroid ultrasonography. We also assessed the effect of potentially confounding factors to modulate the limits of the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.047399

    authors: Kratzsch J,Fiedler GM,Leichtle A,Brügel M,Buchbinder S,Otto L,Sabri O,Matthes G,Thiery J

    更新日期:2005-08-01 00:00:00

  • Efficient cleavage of conjugates of drugs or poisons by immobilized beta-glucuronidase and arylsulfatase in columns.

    abstract:BACKGROUND:Cleavage of conjugates is an important step in toxicological analysis, especially of urine samples. The aim of this study was to combine the advantages and to reduce the disadvantages of acid hydrolysis and conventional enzymatic hydrolysis procedures. METHODS:beta-Glucuronidase (GRD; EC 3.2.1.31) and aryls...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Toennes SW,Maurer HH

    更新日期:1999-12-01 00:00:00

  • Strand displacement amplification (SDA) and transient-state fluorescence polarization detection of Mycobacterium tuberculosis DNA.

    abstract::Strand displacement amplification (SDA) is an isothermal, in vitro method of amplifying a DNA sequence for diagnostic purposes. We have combined SDA with fluorescence polarization detection in a closed, homogeneous format. A fluorescently labeled oligodeoxynucleotide detector probe hybridizes to the amplification prod...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Walker GT,Nadeau JG,Linn CP,Devlin RF,Dandliker WB

    更新日期:1996-01-01 00:00:00

  • Comparison between immunoturbidimetry, size-exclusion chromatography, and LC-MS to quantify urinary albumin.

    abstract:BACKGROUND:The accurate and precise measurement of urinary albumin is critical, since even minor increases are diagnostically sensitive indicators of renal disease, cardiovascular events, and risk for death. To gain insights into potential measurement biases, we systematically compared urine albumin measurements perfor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.107508

    authors: Shaikh A,Seegmiller JC,Borland TM,Burns BE,Ladwig PM,Singh RJ,Kumar R,Larson TS,Lieske JC

    更新日期:2008-09-01 00:00:00

  • Theoretical aspects of one-point calibration: causes and effects of some potential errors, and their dependence on concentration.

    abstract::The potential errors of the one-point calibration technique are described mathematically. I examine the theoretical causes and effects of analytical errors in absorbance and of errors in determining calibration concentration, and discuss techniques for minimizing their impact. The dependence of these errors on the cal...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kemp GJ

    更新日期:1984-07-01 00:00:00

  • Multicenter evaluation of human placental alkaline phosphatase as a possible tumor-associated antigen in serum.

    abstract::Using a solid-phase monoclonal antibody enzyme immuno-assay, we evaluated in a multicenter study (18 laboratories) the utility of evaluating catalytic activity of human placental alkaline phosphatase (hPLAP, EC 3.1.3.1) in serum as a potential tumor marker. We determined hPLAP in serum samples from 130 patients with o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: De Broe ME,Pollet DE

    更新日期:1988-10-01 00:00:00

  • Production of murine hybrid-hybridomas secreting bispecific monoclonal antibodies for use in urease-based immunoassays.

    abstract::To produce bispecific antibodies (BiAbs) for enzyme immunoassay (EIA) to replace antibody-enzyme conjugates, we developed a panel of 8-azaguanine/ouabain-resistant anti-urease variant hybridoma cell lines for use in hybridoma-hybridoma fusions. These variants represent mouse immunoglobulin subclasses IgM, IgG1, IgG2a,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Takahashi M,Fuller SA

    更新日期:1988-09-01 00:00:00

  • Liquid-chromatographic determination of free and total 3,4-dihydroxyphenylglycol and 3-methoxy-4-hydroxyphenylglycol in urine.

    abstract::We describe the conjoint measurement in urine of the alcoholic catecholamine metabolites 3,4-dihydroxyphenylglycol (DHPG) and 3-methoxy-4-hydroxyphenylglycol (MHPG). The method involves extraction with ethyl acetate and back-extraction into acetic acid (MHPG), followed by adsorption onto alumina (DHPG). The separation...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Julien C,Rodriguez C,Sacquet J,Cuisinaud G,Sassard J

    更新日期:1988-05-01 00:00:00

  • Performance characteristics of a novel tandem mass spectrometry assay for serum testosterone.

    abstract:BACKGROUND:Commercial immunoassays for testosterone (Te) may give inaccurate results for samples from women and children, leading to misdiagnosis and inappropriate treatment. We developed a sensitive and specific tandem mass spectrometric assay for measurement of Te at the concentrations encountered in women and childr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.052167

    authors: Kushnir MM,Rockwood AL,Roberts WL,Pattison EG,Bunker AM,Fitzgerald RL,Meikle AW

    更新日期:2006-01-01 00:00:00

  • Improved estimation of fructosamine, as a measure of glycated serum protein, with the Technicon RA-1000 analyzer.

    abstract::We present an improved fructosamine assay for use with the Technicon RA-1000 analyzer. Features of this assay include: specimen throughput of 100 per hour, within-batch CV of 1.5%, between-batch CV of 2.4%, standard curve linear up to 24.9 mmol of fructosamine per liter, and good correlation (r = 0.82) with hemoglobin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: San-Gil F,Schier GM,Moses RG,Gan IE

    更新日期:1985-12-01 00:00:00

  • Manual and centrifugal analyzer determination of cholesterol and triglycerides with single-vial enzymatic reagents.

    abstract::We have assessed Calbiochem single-vial enzymatic reagent systems for the analysis for cholesterol and triglycerides, using manual and centrifugal analyzer techniques. Analysis for cholesterol by both techniques had acceptable performance by the short-term criteria of the Center for Disease Control (CDC) during this s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Peake MJ,Sontrop ME,Fraser CG

    更新日期:1978-11-01 00:00:00

  • Progress toward ultrafast DNA sequencing using solid-state nanopores.

    abstract:BACKGROUND:Measurements of the ionic current flowing through nanometer-scale pores (nanopores) have been used to analyze single DNA and RNA molecules, with the ultimate goal of achieving ultrafast DNA sequencing. However, attempts at purely electronic measurements have not achieved the signal contrast required for sing...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.091231

    authors: Soni GV,Meller A

    更新日期:2007-11-01 00:00:00

  • Detection of intracellular antigens by flow cytometry: comparison of two chemical methods and microwave heating.

    abstract::Detection of intracellular antigens by flow cytometry requires effective fixation and permeabilization of the cell membrane. This study compares three fixation/permeabilization techniques: two commercial chemical reagents, the ORTHOPermeaFix (OPF) and the FIX&PERM Cell Permeabilization Kit (F&P), and a novel method ba...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Millard I,Degrave E,Philippe M,Gala JL

    更新日期:1998-11-01 00:00:00

  • Three radioligands compared for determining cytoplasmic estrogen-receptor content of human breast carcinomas.

    abstract::We compared three radioligands for use in a cytoplasmic estrogen-receptor assay, using pooled cytosol from human breast adenocarcinomas. The estrogen receptor content was determined in vitro by a dextran-coated charcoal method involving a 4-h incubation with and without diethylstilbestrol. Tritiated moxestrol failed t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pieslor PC,Gibson RE,Eckelman WC,Oates KK,Cook B,Reba RC

    更新日期:1982-03-01 00:00:00

  • Determination of erythrocyte folate by competitive protein binding assay preceded by extraction.

    abstract::Determination of the concentration of erythrocyte folate by means of competitive protein binding assay critically depends on the extraction procedure applied. Results will be influenced by variable factors such as the in vitro age of the blood samples, the degree of hemolysis, the presence of ascorbic acid, and the pH...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mortensen E

    更新日期:1976-07-01 00:00:00

  • Hyperamylasemia, specific pancreatic enzymes, and hypoxanthine during recovery from diabetic ketoacidosis.

    abstract::The contribution of the exocrine pancreas to hyperamylasemia in diabetic ketoacidosis was investigated by measuring total amylase, salivary and pancreatic isoamylases, cathodic trypsin-like immunoreactivity, and pancreatic lipase in 12 consecutive patients recovering from diabetic ketoacidosis. Hyperamylasemia was pre...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Møller-Petersen J,Andersen PT,Hjørne N,Ditzel J

    更新日期:1985-12-01 00:00:00

  • Comparison of immunoassays for the selective measurement of human high-molecular weight adiponectin.

    abstract:BACKGROUND:Adiponectin is an adipocyte-derived hormone circulating in different multimer complexes. The high-molecular-weight (HMW) complex is likely the active form of this protein and has been recognized as a risk marker for type 2 diabetes and coronary artery disease (CAD). Because quantification of HMW adiponectin ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.112425

    authors: Liu D,Schuster T,Baumann M,Roos M,Sollinger D,Lutz J,Heemann U,von Eynatten M

    更新日期:2009-03-01 00:00:00

  • A modified radioimmunoassay for 1,25-dihydroxycholecalciferol.

    abstract::A radioimmunoassay for 1,25-dihydroxycholecalciferol which did not cross react with 1,25-dihydroxyergocalciferol is described. IgG fractions were prepared from the serum of rabbits that had been immunized with 1,25-dihydroxycholecalciferol-3-hemisuccinate coupled to bovine albumin. Radioligand binding by the IgG fract...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gray TK,McAdoo T,Pool D,Lester GE,Williams ME,Jones G

    更新日期:1981-03-01 00:00:00

  • Direct radioimmunoassay for serum estriol during pregnancy.

    abstract::I describe an assay for serum estriol during pregnancy, which does not require prior extraction or chromatography of the serum. Fifty microliters of 20-fold diluted serum can be assayed to detect as little as 20 pg of estriol. For a 20 mug/liter serum estriol concentration the CV was 16%; for 100 mug/liter concentrati...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Standefer J

    更新日期:1976-04-01 00:00:00

  • Methylmalonic acid concentrations in serum of normal subjects: biological variability and effect of oral L-isoleucine loads before and after intramuscular administration of cobalamin.

    abstract::The clinical value of measuring concentrations of methylmalonic acid in serum (S-MMA) as an aid in the diagnosis of cobalamin deficiency has recently aroused interest. In 58 healthy subjects, ages 40-68 years, we found a 0.95 reference interval of 0.05-0.37 mumol/L (mean 0.21, SD 0.094). In 33 of the subjects, who wer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rasmussen K,Møller J,Ostergaard K,Kristensen MO,Jensen J

    更新日期:1990-07-01 00:00:00

  • Rapid radiometric assay used to assess lactoferrin in granulocytes.

    abstract::We describe a rapid, precise, and sensitive radiometric assay for human lactoferrin. In this typical "sandwich"-type assay, anti-human lactoferrin is adsorbed onto a polystyrene sphere and bound lactoferrin is detected by the subsequent binding of 125I-labeled anti-human lactoferrin. The assay is accurate for lactofer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Freeman KL,Anderson DC,Hughes B,Buffone GJ

    更新日期:1985-03-01 00:00:00

  • Radioimmunoassay for amatoxins by use of a rapid, 125I-tracer-based system.

    abstract::In this new radioimmunoassay system for determination of amatoxins in urine and plasma, a novel chemical approach is used for antigen and 125I-tracer production, based on a detoxified alpha-amanitin derivative (aldoamanitin). Total assay time, including data processing, is less than 100 min. The lowest detectable conc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Andres RY,Frei W,Gautschi K,Vonderschmitt DJ

    更新日期:1986-09-01 00:00:00

  • High-performance liquid-chromatographic analysis for serotonin and tryptamine excreted in urine after oral loading with L-tryptophan.

    abstract::We describe a method used for determining serotonin and tryptamine in urine after oral loading with their precursor amino acid. Several factors affecting prepurification and chromatographic separation of both indoleamines were optimized, including sample extraction and mobile-phase composition. Under optimal condition...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tsuchiya H,Hayashi T,Tatsumi M,Hoshino Y,Ohtani S,Takagi N

    更新日期:1989-01-01 00:00:00

  • Measurement of urinary oxalate and citrate by capillary electrophoresis and indirect ultraviolet absorbance.

    abstract::We describe a method for measuring urinary oxalate and citrate with capillary electrophoresis (CE) and indirect ultraviolet absorbance detection. Sample preparation is minimal, requiring an acidification, brief centrifugation, and dilution. The method is rapid, with oxalate and citrate having mean migration times of 4...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Holmes RP

    更新日期:1995-09-01 00:00:00