Development of a rapid assay for the analysis of serum cortisol and its implementation into a routine service laboratory.

Abstract:

BACKGROUND:LC-MS/MS is rapidly becoming the technology of choice for measuring steroid hormones. We have developed a rapid LC-MS/MS assay for the routine analysis of serum cortisol. We have used this assay to investigate the effects of gender and exogenous steroid interference on the immunoassay measurement of serum cortisol. METHODS:Zinc sulphate (40 µL) was added to 20 µL of sample. This was vortexed for 10 s followed by the addition of 100 µL of internal standard in methanol. Following mixing and centrifugation, 10 µL of sample was injected into an Acquity LC system coupled to a Quattro Premier tandem mass spectrometer. Serum samples (n = 149) were analysed by LC-MS/MS and two commercial immunoassays. Results were then compared for all samples and for gender differences. A further set of serum samples (n = 171) was analysed by the LC-MS/MS assay and a GC-MS assay. RESULTS:Cortisol had a retention time of 0.98 min and the assay had an injection-to-injection time of 2.6 min per sample. Mean recovery was 99% and mean CV was 8%. The immunoassays gave comparisons of: Roche = 1.23 × LC-MS/MS -1.12 nmol/L and Abbott = 0.94 × LC-MS/MS + 11.97. The comparison with GC-MS showed LC-MS/MS = 1.11 × GC-MS - 22.90. DISCUSSION:We have developed an LC-MS/MS assay for serum cortisol analysis that is suitable for routine clinical use and has been in use in our laboratory for 12 months. The availability of this assay will give more reliable results in patients receiving exogenous steroid therapy.

journal_name

Ann Clin Biochem

authors

Owen LJ,Adaway JE,Davies S,Neale S,El-Farhan N,Ducroq D,Evans C,Rees DA,MacKenzie F,Keevil BG

doi

10.1177/0004563212473448

subject

Has Abstract

pub_date

2013-07-01 00:00:00

pages

345-52

issue

Pt 4

eissn

0004-5632

issn

1758-1001

pii

0004563212473448

journal_volume

50

pub_type

临床试验,杂志文章
  • Who shall control the controllers? A personal views.

    abstract::Many attempt are now being made by external agencies to assess the quality of assay performance in hormone laboratories. Some of the problems associated with this are discussed and some remedies are proposed. ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328101800101

    authors: Jeffcoate SL

    更新日期:1981-01-01 00:00:00

  • The measurement of serum unsaturated iron-binding capacity in the presence of iron-dextran.

    abstract::The standard colorimetric methods most often used for the measurement of serum unsaturated iron binding capacity (UIBC) are subject to gross interference by iron dextran. This paper describes a brief evaluation of an alternative radiometric assay for serum UIBC, based on a commercially available kit method, but incorp...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328802500323

    authors: Kind CN

    更新日期:1988-05-01 00:00:00

  • Postpartum increase of serum thioredoxin concentrations and the relation to CD8 lymphocytes.

    abstract:BACKGROUND:There are few data on oxidative stresses during and after pregnancy, although aggravation of autoimmune disease is implicated in oxidative stress and occurs frequently in the postpartum period. Thioredoxin (TRX) is a stress-inducible protein, and is used as a good biomarker for oxidative stress. To clarify t...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2009.009120

    authors: Kuroda S,Watanabe M,Santo T,Shimizuishi Y,Takano T,Hidaka Y,Kimura T,Iwatani Y

    更新日期:2010-01-01 00:00:00

  • Quality of commercially available controls in laser immunonephelometry.

    abstract::Lack of accuracy in expressing concentrations of specific proteins in different lots of Hyland calibrating reference and quality control materials, supplied for the Hyland PDQ laser nephelometer, prompted an attempt to find alternative and more reliable calibrating materials available commercially. Laser grade (Atlant...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328001700403

    authors: Shulman G

    更新日期:1980-07-01 00:00:00

  • Identification of an unusual gamma counter fault using Trigg's technique for trend detection.

    abstract::A simultaneous deterioration in performance of several radioimmunoassays suggested that equipment was malfunctioning. Replicate counts from an automated gamma counter showed unacceptable variation during a 24-hour period; this variation was detected using Trigg's technique, a sensitive method for trend analysis, and w...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456327801500126

    authors: Challand GS,Cox L

    更新日期:1978-03-01 00:00:00

  • Troponin T for the differential diagnosis of ischaemic myocardial damage.

    abstract::The diagnostic performance of a new enzyme linked immunosorbent assay for the cardiac structural protein troponin T in the differential diagnosis of ischaemic cardiac damage was assessed. A well documented set of patients admitted to the coronary care unit of a district general hospital were studied. At a cutoff value...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329303000102

    authors: Collinson PO,Moseley D,Stubbs PJ,Carter GD

    更新日期:1993-01-01 00:00:00

  • Correction formula for carbamylated haemoglobin in diabetic uraemic patients.

    abstract::The measurement of carbamylated haemoglobin is a useful indicator of uraemic state during the preceding few weeks in patients with renal failure. In diabetic uraemic patients with hyperglycaemia, glycation of haemoglobin may interfere with its carbamylation, as both reactions involve the free amino groups of the prote...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/0004563011900407

    authors: Hammouda AM,Mady GE

    更新日期:2001-03-01 00:00:00

  • Thyroid guidelines - are thyroid-stimulating hormone assays fit for purpose?

    abstract::Most thyroid-stimulating hormone (TSH) assays now have the sensitivity required by thyroid guidelines and allow the reliable identification of patients with both overt and subclinical hyperthyroidism. Clinical guidelines usually quote decision limits for TSH, but often ignore the issue of whether variability in bias b...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456307780480945

    authors: Beckett G,MacKenzie F

    更新日期:2007-05-01 00:00:00

  • The influence of age and sex on tests of thyroid function.

    abstract::Serum concentrations of total thyroid hormones, thyroid hormone binding proteins, free thyroid hormones and thyroid stimulating hormone (TSH) were measured in a large group of healthy normal subjects (n = 218) to determine the influence of age and sex on tests of thyroid function. No effect of age on measurements of t...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328502200506

    authors: Franklyn JA,Ramsden DB,Sheppard MC

    更新日期:1985-09-01 00:00:00

  • Review of investigation and management of severe hyponatraemia in a hospital population.

    abstract::The purpose of this study was to assess retrospectively the prevalence of severe hyponatraemia in a hospital population and its laboratory investigation, treatment and clinical outcome. Over a 6-month period 47 patients (27 women and 20 men) were found to have a plasma sodium concentration of < or = 120 mmol/L (this n...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329903600204

    authors: Crook MA,Velauthar U,Moran L,Griffiths W

    更新日期:1999-03-01 00:00:00

  • A continuous flow method for the estimation of serum alpha-amylase activity.

    abstract::An automated assay for serum amylase is described. Using the AutoAnalyzer II the method employs, as substrate, a solution of dyed amylopectin which is commercially available (DyAmyl-L). After incubation of serum and substrate at 55 degrees C, 1.0 mol/lKOH is introduced and the coloured products of enzymic hydrolysis a...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456327701400190

    authors: Carney JA,Osibeluwo SA,Clements JA,Jay RF

    更新日期:1977-11-01 00:00:00

  • Sodium measurement: effects of differing sampling and analytical methods.

    abstract:BACKGROUND:It is recommended that children receiving intravenous fluids should have frequent biochemical monitoring, in some situations 4-6 hourly. Small changes in sodium must be detected, requiring very high precision from sodium analyses. Some children are monitored using venous blood analysed by indirect ion-select...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456306778904560

    authors: Loughrey CM,Hanna EV,McDonnell M,Archbold GP

    更新日期:2006-11-01 00:00:00

  • Influence of glucuronosyl bilirubin and (EZ)-cyclobilirubin on determination of serum unbound bilirubin by UB-analyser.

    abstract:BACKGROUND:In the enzyme reaction for the determination of the unbound (free) bilirubin concentration by glucose oxidase and peroxidase, materials with low affinity for serum protein are reactive. The influence of these materials on the determination of serum unbound bilirubin was investigated. METHODS Serum samples fr...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456320203900606

    authors: Itoh S,Kawada K,Kusaka T,Yasuda S,Okada H,Imai T,Isobe K

    更新日期:2002-11-01 00:00:00

  • 2,8-Dihydroxyadenine renal stones in a 41-year-old man.

    abstract::A case is presented of a 41-year-old man with a history of recurrent renal stones over 10 years. Analysis of the stone showed that, although it gave a positive reaction with the non-specific phosphotungstic acid test, uricase failed to identify any urate present. Analysis in a reference laboratory confirmed its compos...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456304322880087

    authors: Wilkinson H,Samuell C,Stower M

    更新日期:2004-03-01 00:00:00

  • An audit of management of patients with borderline increased plasma-free metanephrines.

    abstract:BACKGROUND:Measurement of plasma-free metanephrine plus normetanephrine (PFM) is the best screening test for phaeochromocytoma. While clearly raised levels are diagnostic, borderline increases may be associated with factors such as stress and medications, and should prompt a repeat study after interfering factors are w...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2010.010131

    authors: Anas SS,Vasikaran SD

    更新日期:2010-11-01 00:00:00

  • A method for measuring glycerol-blanked triglyceride concentrations by using gas chromatography-isotope dilution mass spectrometry.

    abstract:BACKGROUND:Serum triglyceride concentrations are measured as total glycerides content in many Western countries. In Japan, glycerol-blanked triglycerides (TG-GB) are measured to identify postprandial hypertriglyceridaemia and to minimize the influence of glycerol formulation on serum triglyceride values. However, TG-GB...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563220921884

    authors: Koyama I,Imano H,Nakamura M,Kitamura A,Kiyama M,Miyamoto Y,Iso H

    更新日期:2020-05-01 00:00:00

  • Systematic review on the association between F2-isoprostanes and cardiovascular disease.

    abstract:BACKGROUND:Oxidative stress may play an aetiological role in the development and progression of cardiovascular disease (CVD). However, evidence on its biochemical markers has been controversial. This article aimed to assess the role of F2-isoprostanes, a marker for measuring in vivo lipid oxidation, as a biomarker for ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1258/acb.2012.011263

    authors: Zhang ZJ

    更新日期:2013-03-01 00:00:00

  • Comparison of high sensitivity and contemporary troponin assays for the early detection of acute myocardial infarction in the emergency department.

    abstract:BACKGROUND:Current guidelines define acute myocardial infarction (AMI) by the rise and/or fall of cardiac troponin with ≥1 value above the 99th percentile. Past troponin assays have been unreliable at the lower end of the range. Highly sensitive assays have therefore been developed to increase the clinical sensitivity ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2010.010219

    authors: Aldous SJ,Florkowski CM,Crozier IG,Elliott J,George P,Lainchbury JG,Mackay RJ,Than M,Flaws DF,Borowsky J

    更新日期:2011-05-01 00:00:00

  • Near-patient test for nicotine and its metabolites in saliva to assess smoking habit.

    abstract::Smoking is a major risk factor for periodontal disease, causing bone and tooth loss. Effective management of many oral conditions requires accurate information about smoking. We describe a disposable, 10-min, near-patient saliva test to monitor cigarette smoking. A plastic device contains the dried reagents to measure...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/0004563001899717

    authors: Cope G,Nayyar P,Holder R,Brock G,Chapple I

    更新日期:2000-09-01 00:00:00

  • Intraindividual variation in serum thyroid hormones, parathyroid hormone and insulin-like growth factor-1.

    abstract:BACKGROUND:Biological variation of an analyte is an important determinant of its usefulness. Intraindividual variation in serum thyroid hormones, parathyroid hormone (PTH) and insulin-like growth factor-1 (IGF-1) in healthy subjects was determined in this study. METHODS:Blood samples were taken at weekly intervals for...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2007.007103

    authors: Ankrah-Tetteh T,Wijeratne S,Swaminathan R

    更新日期:2008-03-01 00:00:00

  • High-density lipoprotein, lipid, and carbohydrate metabolism during increasing fitness.

    abstract::Eleven unfit bank executives in sedentary employment exercised daily for 10 weeks according to the Canadian Air-Force 5BX Exercise Programme. Over this period no changes were observed in the glucose or insulin responses to a standard breakfast or to intravenous glucose, or in the glucose response to intravenous insuli...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456327901600115

    authors: Moore RA,Penfold WA,Simpson RD,Simpson RW,Mann JI,Turner RC

    更新日期:1979-03-01 00:00:00

  • Serum iron and total iron-binding capacity determination by flow-injection analysis with atomic absorption detection.

    abstract::The deproteinised sample (150 microliters) is 'injected' into a continuously flowing stream of deionised water which is pumped, via a capillary tube, to the nebuliser of an atomic absorption spectrophotometer. Analytical readout is obtained, in the form of transient peaks, 6 s after sample injection. Before injection ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328302000202

    authors: Rocks BF,Sherwood RA,Turner ZJ,Riley C

    更新日期:1983-03-01 00:00:00

  • Comparison of Amerlex, NML, and Ames total thyroxine and triiodothyronine radioimmunoassay kits.

    abstract::An evaluation of the Amerlex system for determination of total thyroxine (T4) and total triiodothyronine (T3) is described. The within- and between-batch precisions were acceptable, and analyses of quality control material and linearity studies demonstrated good accuracy at the clinical decision levels. The correlatio...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328201900208

    authors: Wilke TJ,Turnbull PA

    更新日期:1982-03-01 00:00:00

  • Some ionic and dilution effects in the measurement of urinary oestrogens in pregnancy.

    abstract::The estimation of oestrogen in aqueous solutions and pregnancy urines using an automated procedure is affected by the presence of certain ions, and by dilution. These effects have been studied by calculating regression equations from the values obtained with urines to which ions have been added with and without urine ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456327601300105

    authors: Simkins A,Worth HG

    更新日期:1976-01-01 00:00:00

  • The entero-insular axis in polycystic ovarian syndrome.

    abstract::We investigated the contributions made by the entero-insular axis, proinsulin and the fractional hepatic extraction of insulin to the hyperinsulinaemia characteristic of polycystic ovarian syndrome (PCOS). We measured plasma glucose, gastric inhibitory polypeptide (GIP), glucagon-like peptide-1 (7-36 amide) (GLP-1(7-3...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329603300303

    authors: Gama R,Norris F,Wright J,Morgan L,Hampton S,Watkins S,Marks V

    更新日期:1996-05-01 00:00:00

  • High-dose hook effect in six automated human chorionic gonadotrophin assays.

    abstract:BACKGROUND:The high-dose hook effect is a well-known phenomenon of two-site immunoassays including those for human chorionic gonadotrophin (hCG). We investigated the occurrence of a high-dose hook effect in six routinely available hCG assays using a sample with a total hCG concentration of approximately 3,600,000 IU/L....

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2010.090304

    authors: Al-Mahdili HA,Jones GR

    更新日期:2010-07-01 00:00:00

  • Antiphospholipid and antioangiogenic activity in females with recurrent miscarriage and antiphospholipid syndrome.

    abstract::Background Antiphospholipid syndrome is an autoimmune disease characterized by thrombosis, fetal losses and thrombocytopenia associated to antiphospholipid antibodies. They are directed to phospholipids, such as cardiolipins (anticardiolipin) and lupus anticoagulant or to complexes formed by phospholipids and protein ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563216672248

    authors: Pelusa HF,Pezzarini E,Basiglio CL,Musuruana J,Bearzotti M,Svetaz MJ,Daniele SM,Bottai H,Arriaga SM

    更新日期:2017-09-01 00:00:00

  • A rapid HPLC method for monitoring plasma levels of caffeine and theophylline using solid phase extraction columns.

    abstract::A simple HPLC method for the determination of caffeine and theophylline in plasma is described. Separation of theobromine, paraxanthine, theophylline, beta-hydroxyethyltheophylline and caffeine is obtained using a mobile phase of 1% acetic acid/methanol (83:17, v/v) and a Waters Associates NOVA-PAK C18 column protecte...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328602300410

    authors: Pickard CE,Stewart AD,Hartley R,Lucock MD

    更新日期:1986-07-01 00:00:00

  • Salivary theophylline concentrations in neonates.

    abstract::Salivary theophylline concentrations in neonates were measured by a homogeneous enzyme immunoassay and compared with serum concentrations. Free serum theophylline concentrations were also compared with salivary concentrations and the values obtained were almost identical. Results using the immunoassay agreed well with...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329403100311

    authors: Thompson SJ

    更新日期:1994-05-01 00:00:00

  • Rapid enzymatic method for the measurement of mannitol in urine.

    abstract::A previously described method for mannitol in urine has been modified and improved. End product inhibition by fructose in the mannitol dehydrogenase method for mannitol has been minimized; the assay is linear over a sample mannitol concentration range of 0-12 mmol/L; no significant interference from other sugars or su...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329102800416

    authors: Blood J,Ingle AR,Allison N,Davies GR,Hill PG

    更新日期:1991-07-01 00:00:00