Thyroid guidelines - are thyroid-stimulating hormone assays fit for purpose?

Abstract:

:Most thyroid-stimulating hormone (TSH) assays now have the sensitivity required by thyroid guidelines and allow the reliable identification of patients with both overt and subclinical hyperthyroidism. Clinical guidelines usually quote decision limits for TSH, but often ignore the issue of whether variability in bias between assays should be considered when such decision limits are implemented. Clinicians and laboratories should appreciate that these decision limits arise largely from historical data that used TSH assays with poorly defined bias. It is thus unlikely that laboratories will be able to apply an appropriate method-related bias adjustment to these TSH cut-offs. Clinicians should appreciate that TSH decision limits should thus be regarded as typical target figures rather than an absolute cut-off and thus can be applied with some degree of flexibility. There is currently insufficient evidence to justify a significant lowering of the upper reference limit for TSH, but fine-tuning of current reference ranges is required since there appears to be no association between the ranking of the assay bias in the UK National External Quality Assessment Service scheme and the manufacturers' quoted reference ranges. There is room for further improvement in TSH assays and this can best be achieved if manufacturers, laboratories and clinicians work together to produce TSH assays and reference ranges that show closer agreement between methods. Until this is achieved, future studies that examine the relationship of TSH with symptoms and treatment should ensure that sufficient information is included in the publication to allow the method related bias of the TSH assay to be clearly described.

journal_name

Ann Clin Biochem

authors

Beckett G,MacKenzie F

doi

10.1258/000456307780480945

subject

Has Abstract

pub_date

2007-05-01 00:00:00

pages

203-8

issue

Pt 3

eissn

0004-5632

issn

1758-1001

journal_volume

44

pub_type

杂志文章
  • Serum and plasma 5-hydroxyindoleacetic acid as an alternative to 24-h urine 5-hydroxyindoleacetic acid measurement.

    abstract:BACKGROUND:Neuroendocrine tumours are slow growing tumours known to secrete a variety of vasoactive peptides which give rise to symptoms of the carcinoid syndrome. The diagnosis and monitoring of patients with neuroendocrine tumours is undertaken in many centres using 24 h urinary measurement of 5-hydroxyindoleacetic a...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563215613109

    authors: Adaway JE,Dobson R,Walsh J,Cuthbertson DJ,Monaghan PJ,Trainer PJ,Valle JW,Keevil BG

    更新日期:2016-09-01 00:00:00

  • Analysis of myeloperoxidase activity in wound fluids as a marker of infection.

    abstract:BACKGROUND:Neutrophilic polymorphonuclear leukocytes play a crucial role in the host defence against bacterial and fungal infections. They participate in the inflammatory response through the liberation of peptides and enzymes like myeloperoxidase (MPO). Therefore, MPO has a potential as a marker enzyme for the diagnos...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2011.010249

    authors: Hasmann A,Wehrschuetz-Sigl E,Marold A,Wiesbauer H,Schoeftner R,Gewessler U,Kandelbauer A,Schiffer D,Schneider KP,Binder B,Schintler M,Guebitz GM

    更新日期:2013-05-01 00:00:00

  • Stabilization of circulating thyroglobulin mRNA transcripts in patients treated for differentiated thyroid carcinoma.

    abstract::Background The clinical utility of serum thyroglobulin in the follow-up of patients with differentiated thyroid carcinoma may be compromised by the presence of endogenous antithyroglobulin antibodies. To prevent interference by antithyroglobulin antibodies several groups have developed real-time PCR-based assays for q...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563216671538

    authors: Feddersen S,Bastholt L,Pedersen SM

    更新日期:2017-09-01 00:00:00

  • Bhattacharya: a new application for quality control.

    abstract::The Bhattacharya method and the 'average of normals' method for internal quality control were compared. Both are based on unselected patient test results. The Bhattacharya method is mostly used in clinical chemistry for calculation of reference intervals but could be modified for quality control procedures. Using the ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329102800413

    authors: Oosterhuis WP,Modderman TA,Dinkelaar RB,Zwinderman AH,van der Helm HJ

    更新日期:1991-07-01 00:00:00

  • Oestrogen and progesterone receptor concentrations in leiomyoma and normal myometrium.

    abstract::The content of cytoplasmic 17 beta oestradiol and progesterone receptors in human uterine leiomyoma and normal myometrium in the Negroid population was determined. Eighteen women of reproductive age, at various stages of the menstrual cycle, were included in the study. The serum oestrogen and progesterone concentratio...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328702400304

    authors: Sadan O,van Iddekinge B,van Gelderen CJ,Savage N,Becker PJ,van der Walt LA,Robinson M

    更新日期:1987-05-01 00:00:00

  • The reduction of peripheral insulin concentrations in obese subjects following a hypocaloric diet: reduced pancreatic secretion or increased hepatic extraction?

    abstract::The fasting hyperinsulinaemia characteristic of obesity is due to pancreatic hypersecretion and is accompanied by a corresponding increase in plasma C-peptide concentrations. The exaggerated plasma insulin and C-peptide responses to oral glucose in obese subjects which is greater for insulin than C-peptide suggests th...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328902600502

    authors: Gama R,Marks V

    更新日期:1989-09-01 00:00:00

  • Revised national guidelines for analysis of cerebrospinal fluid for bilirubin in suspected subarachnoid haemorrhage.

    abstract::It is crucially important to detect subarachnoid haemorrhage (SAH) in all patients in whom it has occurred to select patients for angiography and preventative surgery. A computerized tomography (CT) scan is positive in up to 98% of patients with SAH presenting within 12 h, but is positive in only 50% of those presenti...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2008.007257

    authors: Cruickshank A,Auld P,Beetham R,Burrows G,Egner W,Holbrook I,Keir G,Lewis E,Patel D,Watson I,White P,UK NEQAS Specialist Advisory Group for External Quality Assurance of CSF Proteins and Biochemistry.

    更新日期:2008-05-01 00:00:00

  • 2,8-Dihydroxyadenine renal stones in a 41-year-old man.

    abstract::A case is presented of a 41-year-old man with a history of recurrent renal stones over 10 years. Analysis of the stone showed that, although it gave a positive reaction with the non-specific phosphotungstic acid test, uricase failed to identify any urate present. Analysis in a reference laboratory confirmed its compos...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456304322880087

    authors: Wilkinson H,Samuell C,Stower M

    更新日期:2004-03-01 00:00:00

  • Assessment of the Beckman System 1.

    abstract::The System 1 produced results for glucose and urea which were precise and accurate. It proved suitable as a general laboratory instrument as it samples 28 mul of specimen, is able to calibrate itself, produces results in three minutes, and has the capacity to analyse 56 samples an hour. ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456327701400179

    authors: Potezny N,Quelch J,Fuller B,Geary TD

    更新日期:1977-09-01 00:00:00

  • Interleukin 6 in cerebrospinal fluid of patients with meningitis is not a useful diagnostic marker in the differential diagnosis of meningitis.

    abstract::We assayed interleukin 6 (IL-6) concentrations in cerebrospinal fluid (CSF) from patients affected by meningitis of different aetiologies, and verified whether IL-6 can be used as a diagnostic marker in the differential diagnosis of meningitis. We used a monoclonal antibody enzyme immunoassay to test 98 CSF samples cl...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329703400206

    authors: López-Cortés LF,Cruz-Ruiz M,Gómez-Mateos J,Jiménez-Hernández D,Viciana-Fernández P,Jiménez-Mejías E

    更新日期:1997-03-01 00:00:00

  • Drug interference in clinical chemistry: recommendation of drugs and their concentrations to be used in drug interference studies.

    abstract::A group of international experts prepared two lists of drugs with their serum/plasma and urine concentrations, which should be used when evaluating the performance of a new laboratory method. The two lists were verified by running in vitro interference studies in three European laboratories on Hitachi instruments. The...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1258/0004563011900696

    authors: Sonntag O,Scholer A

    更新日期:2001-07-01 00:00:00

  • Essential data derived from biological variation for establishment and use of lipid analyses.

    abstract::The analytical and biological components of variation of total cholesterol, high density lipoprotein (HDL) cholesterol, HDL3 cholesterol, HDL2 cholesterol and apolipoproteins A-I and B in serum were assessed in 12 apparently healthy individuals. All analytes showed marked individuality and therefore conventional popul...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328902600314

    authors: Ford RP

    更新日期:1989-05-01 00:00:00

  • A continuous flow method for the estimation of serum alpha-amylase activity.

    abstract::An automated assay for serum amylase is described. Using the AutoAnalyzer II the method employs, as substrate, a solution of dyed amylopectin which is commercially available (DyAmyl-L). After incubation of serum and substrate at 55 degrees C, 1.0 mol/lKOH is introduced and the coloured products of enzymic hydrolysis a...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456327701400190

    authors: Carney JA,Osibeluwo SA,Clements JA,Jay RF

    更新日期:1977-11-01 00:00:00

  • Removal of protein-bound and unbound unconjugated bilirubin by perfusion of plasma through an anion-exchange resin in a case of Crigler-Najjar syndrome type I.

    abstract:BACKGROUND:Patients with Crigler-Najjar syndrome, type I (CNS-I) have an inherited absence of hepatocellular bilirubin uridine diphosphate-glucuronosyltransferase activity, which results in severe unconjugated hyperbilirubinaemia, often causing kernicterus and death in infancy or childhood. METHODS:Our patient is a 19...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456303322326443

    authors: Ihara H,Shino Y,Hashizume N,Shimizu N,Aoki T,Yoshida M

    更新日期:2003-09-01 00:00:00

  • Radioimmunoassays of arginine vasopressin and atrial natriuretic peptide: application of a common protocol for plasma extraction using Sep-Pak C18 cartridges.

    abstract::A rapid vacuum-driven procedure, using pre-treated Sep-Pak C18 cartridges, has been developed for the simultaneous extraction of arginine vasopressin (AVP) and atrial natriuretic peptide (ANP) from plasma. Non-specific interference was removed by fractional elution with an aqueous methanol/trifluoroacetic acid (TFA) m...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329202900606

    authors: Penney MD,Hampton D,Oleesky DA,Livingstone C,Mulkerrin E

    更新日期:1992-11-01 00:00:00

  • Total parenteral nutrition and the clinical chemistry laboratory.

    abstract::Parenteral nutrition is a well-established technique for feeding patients with intestinal failure and other conditions which render enteral feeding impossible. Biochemical tests are required in the initial assessment of these patients, for monitoring their response to treatment and for the detection and management of ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1177/000456328702400401

    authors: Marshall WJ,Mitchell PE

    更新日期:1987-07-01 00:00:00

  • Comparison of sample types for N-terminal pro-B-type natriuretic peptide measured on the Siemens Immulite 2500 and Dimension Vista LOCI methods.

    abstract:BACKGROUND:Measurement of serum natriuretic peptides is recommended in patients with suspected heart failure. Assays for N-terminal pro-B-type natriuretic peptide (NT-proBNP) are available on several platforms and can be measured in serum or heparinized plasma. Siemens Healthcare Diagnostics do not recommend the use of...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2012.012053

    authors: Peake RW,Turner HE,Leaper W,Deans KA,Hannah A,Croal BL

    更新日期:2012-09-01 00:00:00

  • Differential extraction of endogenous and exogenous 25-OH-vitamin D from serum makes the accurate quantification in liquid chromatography-tandem mass spectrometry assays challenging.

    abstract:BACKGROUND:Extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis is the method of choice when it comes to the accurate quantification of 25-OH-vitamin D in blood samples. It is generally assumed that the addition of exogenous internal standard allows for the determination of the endo...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563214533316

    authors: Lankes U,Elder PA,Lewis JG,George P

    更新日期:2015-01-01 00:00:00

  • The reproducibility and usefulness of the oral glucose tolerance test in screening for diabetes and other cardiovascular risk factors.

    abstract::We examined the reproducibility of oral glucose tolerance tests (OGTT) using the World Health Organization criterion in 212 Chinese subjects (male 149, female 63) who underwent two 75 g OGTTs within a 6-week period. The overall reproducibility was 65.6% (139/212) of which 74 subjects had normal glucose tolerance, 24 h...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329803500107

    authors: Ko GT,Chan JC,Woo J,Lau E,Yeung VT,Chow CC,Cockram CS

    更新日期:1998-01-01 00:00:00

  • Biochemical investigation of foetal and neonatal thyroid function using the ACS-180SE analyser: clinical application.

    abstract::Despite sonographic detection of foetal goitre, uncertainty persists in the initial diagnosis of thyrotoxicosis and hypothyroidism. The aim of this study was to establish foetal and neonatal iodothyronine and thyrotrophin reference values for the ACS-180SE analyser. From 22 to 36 weeks of gestation, median foetal seru...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456320103800509

    authors: Guibourdenche J,Noël M,Chevenne D,Vuillard E,Voluménie JL,Polak M,Boissinot C,Porquet D,Luton D

    更新日期:2001-09-01 00:00:00

  • Cerebrospinal fluid biochemistry in the diagnosis of multiple sclerosis.

    abstract::The Poser criteria for diagnosing multiple sclerosis (MS) includes clinical, paraclinical and laboratory information. We studied the influence of cerebrospinal fluid (CSF) biochemistry results on the categorisation of patients with suspected MS. A retrospective study was made of 138 patients who had CSF samples sent o...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329002700303

    authors: Ratnaike S,Kilpatrick T,Tress B,Davis S,Kilpatrick C,Byron K,Deam D

    更新日期:1990-05-01 00:00:00

  • Influence of glucuronosyl bilirubin and (EZ)-cyclobilirubin on determination of serum unbound bilirubin by UB-analyser.

    abstract:BACKGROUND:In the enzyme reaction for the determination of the unbound (free) bilirubin concentration by glucose oxidase and peroxidase, materials with low affinity for serum protein are reactive. The influence of these materials on the determination of serum unbound bilirubin was investigated. METHODS Serum samples fr...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456320203900606

    authors: Itoh S,Kawada K,Kusaka T,Yasuda S,Okada H,Imai T,Isobe K

    更新日期:2002-11-01 00:00:00

  • Whole blood osmolality.

    abstract::The osmolality of plasma and heparinised whole blood samples collected from hospital patients was estimated using measurement of the depression of freezing point. There was no clinically significant difference between osmolality measurement made on either whole blood, or plasma taken from the same patient. Neither cel...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328602300115

    authors: Rocks BF,Sherwood RA,Cook JG

    更新日期:1986-01-01 00:00:00

  • Clinical relevance of serum amyloid A protein monitoring in urinary tract infections.

    abstract::We have evaluated the clinical relevance of monitoring acute phase proteins in severe urinary tract infection. Body temperature, white blood cell count, erythrocyte sedimentation rate, serum amyloid A protein (SAA), C-reactive protein (CRP), alpha-1-antichymotrypsin (ACT) and alpha-1-acid glycoprotein (AGP) were deter...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329303000308

    authors: Casl MT,Sabljar-Matovinović M,Kovacević S,Pocanić D,Preden-Kereković V,Jagarinec N

    更新日期:1993-05-01 00:00:00

  • Acquired copper deficiency following prolonged jejunostomy feeds.

    abstract::A 19-year-old man who developed extensive oesophageal lye (Alkali) stricture and received long-term enteral nutrition (eight months) with a jejunostomy tube developed macrocytic anaemia (Hb: 41 g/L) with leucopenia (white blood cell [WBC]: 3.0 x 10(9)/L). The patient's serum vitamin B12, folate, iron and liver functio...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/0004563053857879

    authors: Jayakumar S,Micallef-Eynaud PD,Lyon TD,Cramb R,Jilaihawi AN,Prakash D

    更新日期:2005-05-01 00:00:00

  • Diagnostic value of pleural effusion ischaemia-modified albumin in patients with cardiac failure.

    abstract:BACKGROUND:Ischaemia-modified albumin (IMA) is a relatively new marker of ischaemia. IMA has not been studied previously in pleural effusions due to congestive heart failure (CHF). The aim of our study was to assess the diagnostic value of IMA in the pleural fluid (PF) and serum for the identification of pleural effusi...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2010.010159

    authors: Ozsu S,Gulsoy A,Karahan SC,Mentese A,Nuhoglu I,Ozlu T

    更新日期:2011-01-01 00:00:00

  • Genetic polymorphism of thiopurine S-methyltransferase in Argentina.

    abstract:BACKGROUND:Thiopurine methyltransferase (TPMT) catalyses the S-methylation of 6-thiopurine drugs, which are commonly used in the treatment of autoimmune diseases, leukaemia and organ transplantation. TPMT activity is polymorphic as a result of gene mutations. Ethnic variations in phenotype and genotype have been identi...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456303766477039

    authors: Laróvere LE,de Kremer RD,Lambooy LH,De Abreu RA

    更新日期:2003-07-01 00:00:00

  • An evaluation of measured and calculated serum free cortisol in a group of patients with known adrenal suppression.

    abstract:BACKGROUND:Since more than 90% of cortisol is bound to protein, serum free cortisol (SFC) may be a more appropriate marker of adrenal status than total cortisol. However, measurement of SFC is technically difficult and calculated SFC may offer a more practical alternative. METHODS:SFC, measured by equilibrium dialysis...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2010.009246

    authors: Barlow NL,Holme J,Stockley RA,Clark PM

    更新日期:2010-05-01 00:00:00

  • Disagreement between the Roche Cobas Core and Hybritech TANDEM-E PSA assays when measuring free, complexed and total serum prostate specific antigen.

    abstract::A comparison of the Roche Cobas Core and Hybritech TANDEM-E PSA (prostate specific antigen) assays revealed a large difference in the reactivity of each assay to the separated free and complexed forms of serum PSA in patients with prostatic carcinoma. The Roche assay was relatively much more responsive to the free for...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329403100514

    authors: Tillyer CR,Konings M,Gobin PT,Iqbal J

    更新日期:1994-09-01 00:00:00

  • Quality assessment of urinary organic acid analysis.

    abstract::The number of known inherited metabolic disorders resulting in an organic aciduria has increased steadily over the past two decades. Prompt and reliable detection is both clinically and technically demanding but is essential if appropriate treatment is to be undertaken. This is the first study of laboratory performanc...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329403100203

    authors: Bonham JR,Downing M,Pollitt RJ,Manning NJ,Carpenter KH,Olpin SE,Allen JC,Worthy E

    更新日期:1994-03-01 00:00:00