Diagnosis of breast cancer using fluorescence and diffuse reflectance spectroscopy: a Monte-Carlo-model-based approach.

Abstract:

:We explore the use of Monte-Carlo-model-based approaches for the analysis of fluorescence and diffuse reflectance spectra measured ex vivo from breast tissues. These models are used to extract the absorption, scattering, and fluorescence properties of malignant and nonmalignant tissues and to diagnose breast cancer based on these intrinsic tissue properties. Absorption and scattering properties, including beta-carotene concentration, total hemoglobin concentration, hemoglobin saturation, and the mean reduced scattering coefficient are derived from diffuse reflectance spectra using a previously developed Monte Carlo model of diffuse reflectance. A Monte Carlo model of fluorescence described in an earlier manuscript was employed to retrieve the intrinsic fluorescence spectra. The intrinsic fluorescence spectra were decomposed into several contributing components, which we attribute to endogenous fluorophores that may present in breast tissues including collagen, NADH, and retinol/vitamin A. The model-based approaches removes any dependency on the instrument and probe geometry. The relative fluorescence contributions of individual fluorescing components, as well as beta-carotene concentration, hemoglobin saturation, and the mean reduced scattering coefficient display statistically significant differences between malignant and adipose breast tissues. The hemoglobin saturation and the reduced scattering coefficient display statistically significant differences between malignant and fibrous/benign breast tissues. A linear support vector machine classification using (1) fluorescence properties alone, (2) absorption and scattering properties alone, and (3) the combination of all tissue properties achieves comparable classification accuracies of 81 to 84% in sensitivity and 75 to 89% in specificity for discriminating malignant from nonmalignant breast tissues, suggesting each set of tissue properties are diagnostically useful for the discrimination of breast malignancy.

journal_name

J Biomed Opt

authors

Zhu C,Palmer GM,Breslin TM,Harter J,Ramanujam N

doi

10.1117/1.2931078

subject

Has Abstract

pub_date

2008-05-01 00:00:00

pages

034015

issue

3

eissn

1083-3668

issn

1560-2281

journal_volume

13

pub_type

杂志文章
  • Fast vascular component of cortical spreading depression revealed in rats by blood pulsation imaging.

    abstract::Cortical spreading depression (CSD) is a slowly propagating wave of depolarization of neurons and glia and has a less characterized vascular component. CSD is a commonly used phenomenon to test new methods of live brain imaging. Application of a blood pulsations imaging (BPI) technique to study of CSD induced with hig...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.4.046011

    authors: Teplov V,Shatillo A,Nippolainen E,Gröhn O,Giniatullin R,Kamshilin AA

    更新日期:2014-04-01 00:00:00

  • Review of clinical approaches in fluorescence lifetime imaging ophthalmoscopy.

    abstract::Autofluorescence-based imaging techniques have become very important in the ophthalmological field. Being noninvasive and very sensitive, they are broadly used in clinical routines. Conventional autofluorescence intensity imaging is largely influenced by the strong fluorescence of lipofuscin, a fluorophore that can be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.23.9.091415

    authors: Sauer L,Andersen KM,Dysli C,Zinkernagel MS,Bernstein PS,Hammer M

    更新日期:2018-09-01 00:00:00

  • Early detection of colorectal cancer relapse by infrared spectroscopy in "normal" anastomosis tissue.

    abstract::Colorectal cancer is one of the most aggressive cancers usually occurring in people above the age of 50 years. In the United States, colorectal cancer is the third most diagnosed cancer. The American Cancer Society has estimated 96,830 new cases of colon cancer and 40,000 new cases of rectal cancer in 2014 in the Unit...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.075007

    authors: Salman A,Sebbag G,Argov S,Mordechai S,Sahu RK

    更新日期:2015-07-01 00:00:00

  • High-speed 1310 nm-band spectral domain optical coherence tomography at 184,000 lines per second.

    abstract::We propose a useful method to boost the imaging speed for spectral domain optical coherence tomography (SDOCT) by multiplying a number of high-speed spectrometers used in the system with selective precise control of data-recording and data-reading phases for spectral cameras employed in each spectrometer. To demonstra...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3592492

    authors: An L,Guan G,Wang RK

    更新日期:2011-06-01 00:00:00

  • Intrauterine photoacoustic and ultrasound imaging probe.

    abstract::Intrauterine photoacoustic and ultrasound imaging are probe-based imaging modalities with translational potential for use in detecting endometrial diseases. This deep-tissue imaging probe design allows for the retrofitting of commercially available endometrial sampling curettes. The imaging probe presented here has a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.4.046008

    authors: Miranda C,Barkley J,Smith B

    更新日期:2018-04-01 00:00:00

  • Effect of light losses of sample between two integrating spheres on optical properties estimation.

    abstract::A Monte Carlo algorithm is applied to simulate the measurements of a sample with glass slides sandwiched between the double integrating sphere (DIS) setup. The effects caused by various parameters, such as the sample port of integrating sphere, thicknesses, and optical properties of the sample, on light losses and opt...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2815691

    authors: Zhu D,Lu W,Zeng S,Luo Q

    更新日期:2007-11-01 00:00:00

  • Pulsed photoacoustic flow imaging with a handheld system.

    abstract::Flow imaging is an important technique in a range of disease areas, but estimating low flow speeds, especially near the walls of blood vessels, remains challenging. Pulsed photoacoustic flow imaging can be an alternative since there is little signal contamination from background tissue with photoacoustic imaging. We p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.2.026004

    authors: van den Berg PJ,Daoudi K,Steenbergen W

    更新日期:2016-02-01 00:00:00

  • Confocal fluorescence microscope with dual-axis architecture and biaxial postobjective scanning.

    abstract::We present a novel confocal microscope that has dual-axis architecture and biaxial postobjective scanning for the collection of fluorescence images from biological specimens. This design uses two low-numerical-aperture lenses to achieve high axial resolution and long working distance, and the scanning mirror located d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1760760

    authors: Wang TD,Contag CH,Mandella MJ,Chan NY,Kino GS

    更新日期:2004-07-01 00:00:00

  • Stress analysis in oral obturator prostheses, part II: photoelastic imaging.

    abstract::In part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-reta...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.6.066012

    authors: Pesqueira AA,Goiato MC,da Silva EV,Haddad MF,Moreno A,Zahoui A,dos Santos DM

    更新日期:2014-06-01 00:00:00

  • High-magnification vascular imaging to reject false-positive sites in situ during Hexvix® fluorescence cystoscopy.

    abstract::Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3484257

    authors: Lovisa B,Jichlinski P,Weber BC,Aymon D,van den Bergh H,Wagnières G

    更新日期:2010-09-01 00:00:00

  • Performance of a lookup table-based approach for measuring tissue optical properties with diffuse optical spectroscopy.

    abstract::Diffuse optical spectroscopy (DOS) provides a powerful tool for fast and noninvasive disease diagnosis. The ability to leverage DOS to accurately quantify tissue optical parameters hinges on the model used to estimate light-tissue interaction. We describe the accuracy of a lookup table (LUT)-based inverse model for me...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.5.057001

    authors: Nichols BS,Rajaram N,Tunnell JW

    更新日期:2012-05-01 00:00:00

  • Anatomical image-guided fluorescence molecular tomography reconstruction using kernel method.

    abstract::Fluorescence molecular tomography (FMT) is an important in vivo imaging modality to visualize physiological and pathological processes in small animals. However, FMT reconstruction is ill-posed and ill-conditioned due to strong optical scattering in deep tissues, which results in poor spatial resolution. It is well kn...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.055001

    authors: Baikejiang R,Zhao Y,Fite BZ,Ferrara KW,Li C

    更新日期:2017-05-01 00:00:00

  • Quantitative imaging of protein-protein interactions by multiphoton fluorescence lifetime imaging microscopy using a streak camera.

    abstract::Fluorescence lifetime imaging microscopy (FLIM) using multiphoton excitation techniques is now finding an important place in quantitative imaging of protein-protein interactions and intracellular physiology. Recent developments in multiphoton FLIM methods are reviewed and a novel multiphoton FLIM system using a streak...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1577574

    authors: Krishnan RV,Masuda A,Centonze VE,Herman B

    更新日期:2003-07-01 00:00:00

  • Bioluminescence of Vibrio fischeri: bacteria respond quickly and sensitively to pulsed microwave electric (but not magnetic) fields.

    abstract::Biological systems with intrinsic luminescent properties serve as powerful and noninvasive bioreporters for real-time and label-free monitoring of cell physiology. This study employs the bioluminescent marine bacterium Vibrio fischeri to investigate the effects of separated microwave electric (E) and magnetic (H) fiel...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.5.051412

    authors: Williams CF,Geroni GM,Lloyd D,Choi H,Clark N,Pirog A,Lees J,Porch A

    更新日期:2019-02-01 00:00:00

  • Myocardial tissue oxygenation estimated with calibrated diffuse reflectance spectroscopy during coronary artery bypass grafting.

    abstract::We present a study using a method able to assess tissue oxygenation, taking into account the absorption and the level of scattering in myocardial tissue using a calibrated fiber optic probe. With this method, interindividual comparisons of oxygenation can be made despite varying tissue optical properties during corona...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.2976433

    authors: Häggblad E,Lindbergh T,Karlsson MG,Casimir-Ahn H,Salerud EG,Strömberg T

    更新日期:2008-09-01 00:00:00

  • Measurement of ocular anterior segment dimension and wavefront aberration simultaneously during accommodation.

    abstract::In order to understand the relationship between accommodation and vision quality, a custom-built ultra-long scan depth spectral domain optical coherence tomography (UL-SDOCT) and a Shack-Hartmann wavefront sensor (HSWFS) were combined. The resolution and scan depth of UL-SDOCT are 6 μm and 15.6 mm, respectively, which...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.12.120501

    authors: Shi G,Wang Y,Yuan Y,Wei L,Lv F,Zhang Y

    更新日期:2012-12-01 00:00:00

  • Computational segmentation of collagen fibers from second-harmonic generation images of breast cancer.

    abstract::Second-harmonic generation (SHG) imaging can help reveal interactions between collagen fibers and cancer cells. Quantitative analysis of SHG images of collagen fibers is challenged by the heterogeneity of collagen structures and low signal-to-noise ratio often found while imaging collagen in tissue. The role of collag...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.1.016007

    authors: Bredfeldt JS,Liu Y,Pehlke CA,Conklin MW,Szulczewski JM,Inman DR,Keely PJ,Nowak RD,Mackie TR,Eliceiri KW

    更新日期:2014-01-01 00:00:00

  • Human graft cornea and laser incisions imaging with micrometer scale resolution full-field optical coherence tomography.

    abstract::Micrometer scale resolution full-field optical coherence tomography (FF-OCT) is developed for imaging human graft corneas. Three-dimensional (3-D) images with ultrahigh resolution (respectively, 1 and 1.5 μm in the axial and transverse directions), comparable to traditional histological sections, are obtained allowing...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3486544

    authors: Latour G,Georges G,Lamoine LS,Deumié C,Conrath J,Hoffart L

    更新日期:2010-09-01 00:00:00

  • Volume holographic imaging endoscopic design and construction techniques.

    abstract::A reflectance volume holographic imaging (VHI) endoscope has been designed for simultaneous in vivo imaging of surface and subsurface tissue structures. Prior utilization of VHI systems has been limited to ex vivo tissue imaging. The VHI system presented in this work is designed for laparoscopic use. It consists of a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.056010

    authors: Howlett ID,Han W,Gordon M,Rice P,Barton JK,Kostuk RK

    更新日期:2017-05-01 00:00:00

  • simEye: Computer-based simulation of visual perception under various eye defects using Zernike polynomials.

    abstract::We describe a computer eye model that allows for aspheric surfaces and a three-dimensional computer-based ray-tracing technique to simulate optical properties of the human eye and visual perception under various eye defects. Eye surfaces, such as the cornea, eye lens, and retina, are modeled or approximated by a set o...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2357734

    authors: Fink W,Micol D

    更新日期:2006-09-01 00:00:00

  • Depth-correction algorithm that improves optical quantification of large breast lesions imaged by diffuse optical tomography.

    abstract::Optical quantification of large lesions imaged with diffuse optical tomography in reflection geometry is depth dependence due to the exponential decay of photon density waves. We introduce a depth-correction method that incorporates the target depth information provided by coregistered ultrasound. It is based on balan...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3573814

    authors: Tavakoli B,Zhu Q

    更新日期:2011-05-01 00:00:00

  • Pediatric Vision Screener 2: pilot study in adults.

    abstract::Amblyopia is a form of visual impairment caused by ocular misalignment (strabismus) or defocus in an otherwise healthy eye. If detected early, the condition can be fully treated, yet over half of all children with amblyopia under age 5 escape detection. We developed a Pediatric Vision Screener (PVS) to detect amblyopi...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.1805561

    authors: Nassif DS,Piskun NV,Gramatikov BI,Guyton DL,Hunter DG

    更新日期:2004-11-01 00:00:00

  • Optically tunable nanoparticle contrast agents for early cancer detection: model-based analysis of gold nanoshells.

    abstract::Many optical diagnostic approaches rely on changes in scattering and absorption properties to generate optical contrast between normal and diseased tissue. Recently, there has been increasing interest in using exogenous agents to enhance this intrinsic contrast with particular emphasis on the development for targeting...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2141825

    authors: Lin AW,Lewinski NA,West JL,Halas NJ,Drezek RA

    更新日期:2005-11-01 00:00:00

  • Offset-sparsity decomposition for automated enhancement of color microscopic image of stained specimen in histopathology.

    abstract::We propose an offset-sparsity decomposition method for the enhancement of a color microscopic image of a stained specimen. The method decomposes vectorized spectral images into offset terms and sparse terms. A sparse term represents an enhanced image, and an offset term represents a "shadow." The related optimization ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.076012

    authors: Kopriva I,Hadžija MP,Hadžija M,Aralica G

    更新日期:2015-07-01 00:00:00

  • Temperature-modulated fluorescence tomography based on both concentration and lifetime contrast.

    abstract::It is challenging to image fluorescence objects with high spatial resolution in a highly scattering medium. Recently reported temperature-sensitive indocyanine green-loaded pluronic nanocapsules can potentially alleviate this problem. Here we demonstrate a frequency-domain temperature-modulated fluorescence tomography...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.5.056007

    authors: Lin Y,Kwong TC,Bolisay L,Gulsen G

    更新日期:2012-05-01 00:00:00

  • Near-ultraviolet removal rates for subgingival dental calculus at different irradiation angles.

    abstract::The laser ablation rate of subgingival dental calculus irradiated at a 400-nm-wavelength, 7.4-mJ pulse energy, and 85- and 20-deg irradiation angles is measured using laser triangulation. Three-dimensional images taken before and after irradiation create a removal map with 6-μm axial resolution. Fifteen human teeth wi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3564907

    authors: Schoenly JE,Seka WD,Rechmann P

    更新日期:2011-07-01 00:00:00

  • Three-dimensional optical method for integrated visualization of mouse islet microstructure and vascular network with subcellular-level resolution.

    abstract::Microscopic visualization of islets of Langerhans under normal and diabetic conditions is essential for understanding the pathophysiology of the disease. The intrinsic opacity of pancreata, however, limits optical accessibility for high-resolution light microscopy of islets in situ. Because the standard microtome-base...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3470241

    authors: Fu YY,Lu CH,Lin CW,Juang JH,Enikolopov G,Sibley E,Chiang AS,Tang SC

    更新日期:2010-07-01 00:00:00

  • Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy.

    abstract::Muscle blood flow (MBF) and muscle oxygen saturation (SmO(2)) were measured at eight locations (four proximal, four distal) over a 4 x 8 cm(2) area of the vastus lateralis at rest and immediately after isometric, maximal quadriceps contraction using multichannel, frequency-domain, near-infrared spectroscopy. A venous ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1646417

    authors: Quaresima V,Ferrari M,Franceschini MA,Hoimes ML,Fantini S

    更新日期:2004-03-01 00:00:00

  • Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction.

    abstract::Intravascular near-infrared fluorescence (NIRF) imaging offers a new approach for characterizing atherosclerotic plaque, but random catheter positioning within the vessel lumen results in variable light attenuation and can yield inaccurate measurements. We hypothesized that NIRF measurements could be corrected for var...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.5.056009

    authors: Dixon AJ,Hossack JA

    更新日期:2013-05-01 00:00:00

  • Listening to membrane potential: photoacoustic voltage-sensitive dye recording.

    abstract::Voltage-sensitive dyes (VSDs) are designed to monitor membrane potential by detecting fluorescence changes in response to neuronal or muscle electrical activity. However, fluorescence imaging is limited by depth of penetration and high scattering losses, which leads to low sensitivity in vivo systems for external dete...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.4.045006

    authors: Zhang HK,Yan P,Kang J,Abou DS,Le HN,Jha AK,Thorek DL,Kang JU,Rahmim A,Wong DF,Boctor EM,Loew LM

    更新日期:2017-04-01 00:00:00