Greenstick fracture of the scapula: a cause of scapular winging.

Abstract:

:A case of an angulated, greenstick fracture of the scapula mimicking scapular winging in a skeletally immature 12-year-old boy is described. The bony deformity was visualized with plain radiography. CT was helpful in exclusion of a thoracic injury or an underlying neoplasm. Closed reduction yielded satisfactory results. Based on this 1 case only, we recommend consideration of closed reduction in children with significantly angulated greenstick fractures of the scapula without underlying thoracic pathology.

journal_name

J Orthop Trauma

authors

Bowen TR,Miller F

doi

10.1097/01.bot.0000174707.10980.f4

subject

Has Abstract

pub_date

2006-02-01 00:00:00

pages

147-9

issue

2

eissn

0890-5339

issn

1531-2291

pii

00005131-200602000-00012

journal_volume

20

pub_type

杂志文章
  • Triangular osteosynthesis of vertically unstable sacrum fractures: a new concept allowing early weight-bearing.

    abstract:OBJECTIVE:Presentation of a new triangular osteosynthesis technique that permits early weight-bearing in vertically unstable sacral fractures. DESIGN:Retrospective evaluation of a consecutive series. SETTING:Level I trauma center. PATIENTS:Thirty-four patients, twenty-eight of whom were polytraumatized, all with ver...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199806000-00002

    authors: Schildhauer TA,Josten C,Muhr G

    更新日期:1998-06-01 00:00:00

  • The Incidence of Posterior Malleolar Involvement in Distal Spiral Tibia Fractures: Is it Higher than We Think?

    abstract:OBJECTIVES:To investigate the incidence of concomitant posterior malleolar fractures (PMFs) in operative, distal-third, spiral tibia fractures. DESIGN:Prospective protocol with retrospective review of data. SETTING:Single, Level 1 trauma center. PATIENTS/PARTICIPANTS:One hundred ninety-three consecutive, skeletally ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001307

    authors: Sobol GL,Shaath MK,Reilly MC,Adams MR,Sirkin MS

    更新日期:2018-11-01 00:00:00

  • Nonoperative treatment of intermediate severity lateral compression type 1 pelvic ring injuries with minimally displaced complete sacral fracture.

    abstract:OBJECTIVES:Controversy exists regarding optimum management of lateral compression type 1 (LC1) pelvic ring injuries (OTA type 61-B2.1), particularly in patients with complete sacral fractures. We hypothesized that nonoperative treatment would result in acceptable functional outcomes. DESIGN:Database review. SETTING:L...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000130

    authors: Gaski GE,Manson TT,Castillo RC,Slobogean GP,OʼToole RV

    更新日期:2014-12-01 00:00:00

  • Surgical exposure and fixation of displaced type IV, V, and VI glenoid fractures.

    abstract::Displaced intra-articular fractures of the glenoid are rare and frequently result from high-energy injuries. Types IV, V, and VI fractures have in common a fracture line which extends medially into the scapular body. These fracture patterns present unique challenges for surgical approaches and reduction and fixation s...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e31817d5356

    authors: Nork SE,Barei DP,Gardner MJ,Schildhauer TA,Mayo KA,Benirschke SK

    更新日期:2008-08-01 00:00:00

  • Distal locking screw insertion using a cannulated drill bit: technical note.

    abstract::A modified freehand method using a cannulated drill bit for the insertion of distal locking screws for interlocking intramedullary nails is described. It should be useful to introduce surgeons to interlocking and to aid those who are not comfortable with the freehand method. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199306000-00009

    authors: Barrick EF

    更新日期:1993-01-01 00:00:00

  • Locked plates combined with minimally invasive insertion technique for the treatment of periprosthetic supracondylar femur fractures above a total knee arthroplasty.

    abstract:OBJECTIVE:New locked plate devices offer theoretical advantages for the treatment of supracondylar femur fractures associated with a total knee arthroplasty (TKA). These devices also can be inserted with relative ease by using minimally invasive techniques, provide a fixed angle construct, and improve fixation in osteo...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200603000-00005

    authors: Ricci WM,Loftus T,Cox C,Borrelli J

    更新日期:2006-03-01 00:00:00

  • Plate fixation of femoral nonunions over an intramedullary nail with autogenous bone grafting.

    abstract:OBJECTIVE:To describe a novel approach for the treatment of nonunions of diaphyseal femur fractures. DESIGN:Retrospective review. SETTING:University hospital. PATIENTS:Seven patients (six men, one woman, average age 42.5 years) with diaphyseal femoral fracture nonunions treated between November 2006 and November 200...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181dfbb33

    authors: Hakeos WM,Richards JE,Obremskey WT

    更新日期:2011-02-01 00:00:00

  • Retrograde nailing of humeral shaft fractures: a biomechanical study of its effects on the strength of the distal humerus.

    abstract:OBJECTIVES:The purpose of this study was to evaluate the loss of strength in the distal humerus that resulted from the creation of two different entry portals used for retrograde humeral nailing. DESIGN:Nine pairs, treated as blocks of size two, of fresh frozen humeri from individuals free of musculoskeletal disease w...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200002000-00005

    authors: Strothman D,Templeman DC,Varecka T,Bechtold J

    更新日期:2000-02-01 00:00:00

  • Anatomic Fixation of Supination External Rotation Type IV Equivalent Ankle Fractures.

    abstract:OBJECTIVES:To compare radiographic and clinical outcomes of supination external rotation type IV equivalent (SER IV E) ankle fractures (AO/OTA classification 44-B2.1) treated with transsyndesmotic screw fixation with those treated with deltoid and posterior inferior tibiofibular ligament (PITFL) repair. DESIGN:Case se...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000318

    authors: Little MM,Berkes MB,Schottel PC,Garner MR,Lazaro LE,Birnbaum JF,Helfet DL,Lorich DG

    更新日期:2015-05-01 00:00:00

  • A method for detection of lateral malleolar malrotation using conventional fluoroscopy.

    abstract::Recent studies on ankle syndesmosis injuries have shown that a significant amount of rotational malediction of the distal fibula are missed and may lead to poor functional outcome. A new set of radiographic criteria were developed to help detect distal fibula internal and external rotation using conventional fluorosco...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31828f89a9

    authors: Marmor M,Kandemir U,Matityahu A,Jergesen H,McClellan T,Morshed S

    更新日期:2013-12-01 00:00:00

  • Predictors of reoperation following operative management of fractures of the tibial shaft.

    abstract:BACKGROUND:Accurate prediction of likelihood of reoperation in patients with tibial shaft fractures would facilitate optimal management. Previous studies were limited by small sample sizes and noncomprehensive examination of possible risk factors. OBJECTIVE:We conducted an observational study to determine which progno...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200305000-00006

    authors: Bhandari M,Tornetta P 3rd,Sprague S,Najibi S,Petrisor B,Griffith L,Guyatt GH

    更新日期:2003-05-01 00:00:00

  • Percutaneous pelvic fixation using working portals in a circumferential pelvic antishock sheet.

    abstract::Unstable pelvic ring injuries are associated with an increased mortality rate, most commonly from severe hemorrhage. Circumferential pelvic antishock sheeting has proven effective for rapidly stabilizing the pelvic ring and has become an integral part of resuscitation protocols. Acute antishock sheet placement frequen...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181a87c6c

    authors: Gardner MJ,Osgood G,Molnar R,Chip Routt ML Jr

    更新日期:2009-10-01 00:00:00

  • Technical problems and complications in the removal of the less invasive stabilization system.

    abstract:OBJECTIVES:This study was designed to evaluate the frequency of intraoperative problems and complications involved with Less Invasive Stabilization System (LISS) plate removal. DESIGN:Retrospective study. SETTING:Single academic level I trauma center. METHODS:Medical records were reviewed for demographics, surgical ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181c29bf5

    authors: Suzuki T,Smith WR,Stahel PF,Morgan SJ,Baron AJ,Hak DJ

    更新日期:2010-06-01 00:00:00

  • Orthopaedic Trauma in the Developing World: Where Are the Gaps in Research and What Can Be Done?

    abstract:PURPOSE:There are an estimated 1.2 million deaths from road traffic injuries annually, disproportionately affecting patients in low-resource settings. The purpose of this scoping review is to identify knowledge gaps in global orthopaedic trauma in an effort to help prioritize future research. METHODS:Using the 6-stage...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000001293

    authors: Challa S,Wu HH,Cunningham BP,Liu M,Patel K,Shearer DW,Morshed S,Miclau T

    更新日期:2018-10-01 00:00:00

  • External fixation with standard AO-plates: technique, indications, and results in 31 cases.

    abstract::The standard AO-plate was used as an external fixator in 31 patients with an infected nonunion or open fracture mainly of the upper extremity. With the use of this technique, good stability can be achieved with an inexpensive and relatively simple construction. The low profile of the frame is an advantage for the pati...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200301000-00010

    authors: Kerkhoffs GM,Kuipers MM,Marti RK,Van der Werken C

    更新日期:2003-01-01 00:00:00

  • Posteromedial Approach to Tibial Plateau Fracture Nonunion.

    abstract::Tibial plateau fractures can involve planes that require reduction and stabilization from a posterior approach. This includes posteromedial, posterolateral, and posterior column shear type injuries. This video outlines the prone posteromedial approach to the tibial plateau for posterior column fracture exposure, reduc...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001826

    authors: Shields CN,Eftekhary N,Egol KA

    更新日期:2020-08-01 00:00:00

  • Does the Angle of the Nail Matter for Pertrochanteric Fracture Reduction? Matching Nail Angle and Native Neck-Shaft Angle.

    abstract:OBJECTIVES:To determine whether fixation of pertrochanteric hip fractures with cephalomedullary nails (CMNs) with a neck-shaft angle (NSA) less than the native NSA affects reduction and lag screw cutout. DESIGN:Retrospective comparative study. SETTING:Level I trauma center. PATIENTS/PARTICIPANTS:Patients treated wit...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001096

    authors: Parry JA,Barrett I,Schoch B,Yuan B,Cass J,Cross W

    更新日期:2018-04-01 00:00:00

  • Improving business IQ in medicine through mentorship and education.

    abstract::Business intelligence in the field of medicine, particularly with physicians, has been an abstract concept at best with no objective metric. Furthermore, in many arenas, it was taboo for medical students, residents, and physicians to discuss the business and finances of their work for fear that it would interfere with...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000177

    authors: Hill AD

    更新日期:2014-09-01 00:00:00

  • Can We Estimate the Amount of Malrotation in Supracondylar Humerus Fractures After CRPP?

    abstract:BACKGROUND:Acceptable amounts of malrotation after CRPP for pediatric supracondylar humerus fracture (SCHFx) have yet to be defined. This is an attempt to correlate radiographic parameters of a malrotated SCHFx with degrees of rotational malalignment to assist intraoperative assessment of reduction. METHODS:3D models ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001735

    authors: Prabhakar P,Pierce WA,Standefer KD,Ho CA

    更新日期:2020-07-01 00:00:00

  • Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures.

    abstract:OBJECTIVE:Comparison between a Less Invasive Stabilization System (LISS) using monocortical screws with angular stability and two conventional plate systems Condylar Buttress Plate (CBP) and Dynamic Condylar Screw (DCS) for the treatment of distal femoral fractures with respect to biomechanical properties. DESIGN:Biom...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200109000-00004

    authors: Marti A,Fankhauser C,Frenk A,Cordey J,Gasser B

    更新日期:2001-09-01 00:00:00

  • Arthroplasty Versus Internal Fixation for the Treatment of Undisplaced Femoral Neck Fractures: A Retrospective Cohort Study.

    abstract:OBJECTIVE:To compare the 24-month risk of mortality between arthroplasty and internal fixation for undisplaced femoral neck fractures (FNFs). DESIGN:Retrospective cohort study. SETTING:Secondary data analysis of 2 multinational randomized controlled trials. PARTICIPANTS:Patients aged 50 years or older with a FNF. I...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001940

    authors: Afaq S,OʼHara NN,Schemitsch EH,Bzovsky S,Sprague S,Poolman RW,Frihagen F,Heels-Ansdell D,Bhandari M,Swiontkowski M,Slobogean GP,FAITH Investigators.,HEALTH Investigators.

    更新日期:2020-11-01 00:00:00

  • Removal of a broken Synthes proximal spiral blade.

    abstract::Use of cephalomedullary nails is an option for treatment of subtrochanteric femur fractures. However, the magnitude of bending forces in this area of the femur often can lead to implant failure before union. We report on a case of hardware failure of a specific device (Synthes spiral blade) and a method for removal. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199803000-00010

    authors: Stover MD,Lin I,Bosse MJ

    更新日期:1998-03-01 00:00:00

  • The treatment of intertrochanteric fractures: results using an intramedullary nail with integrated cephalocervical screws and linear compression.

    abstract:OBJECTIVE:A new device for the treatment of intertrochanteric fractures that uses 2 cephalocervical screws in an integrated mechanism allowing linear intraoperative compression and rotational stability of the head/neck fragment has been developed. The aim of this study was to describe the results using this device for ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章

    doi:10.1097/BOT.0b013e31819211b2

    authors: Ruecker AH,Rupprecht M,Gruber M,Gebauer M,Barvencik F,Briem D,Rueger JM

    更新日期:2009-01-01 00:00:00

  • An investigation of the bending stiffness of and the plane stresses generated by a flanged external fixator pin.

    abstract::In an attempt to reduce pin loosening, a flanged external fixator pin has been designed and its bending stiffness has been compared with that of a standard pin. The pins were inserted into pilot holes previously drilled into a piece of teak hardwood. Loads of different magnitudes were applied at a fixed moment arm and...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199502000-00013

    authors: Oni OO,Capper M,Soutis C

    更新日期:1995-02-01 00:00:00

  • No effect of low-intensity ultrasound on healing time of intramedullary fixed tibial fractures.

    abstract:OBJECTIVE:To determine whether stimulation with low-intensity ultrasound will reduce the radiologic healing time of fresh tibial shaft fractures fixed with a reamed and statically locked intramedullary rod. DESIGN:Prospective, randomized, double blinded, and placebo controlled. PATIENTS AND METHODS:Thirty-two adult p...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-199905000-00005

    authors: Emami A,Petrén-Mallmin M,Larsson S

    更新日期:1999-05-01 00:00:00

  • Biomechanical evaluation of methods of internal fixation of the distal humerus.

    abstract::The best results following fractures of the distal humerus are provided by anatomic reduction and rigid internal fixation. Plates of two designs placed in five different fixation configurations were used to determine the construct that would maximize rigidity of fixation of the distal humerus. Using a cadaver distal h...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Schemitsch EH,Tencer AF,Henley MB

    更新日期:1994-12-01 00:00:00

  • Intrawound Antibiotic Powder in Acetabular Fracture Open Reduction Internal Fixation Does Not Reduce Surgical Site Infections.

    abstract:OBJECTIVES:To compare the risks of surgical site infection (SSI) and postoperative complications after acetabular fracture open reduction internal fixation (ORIF) in patients receiving topical intrawound antibiotic powder compared to those not receiving antibiotic powder (control group). DESIGN:Retrospective cohort SE...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001943

    authors: Cichos KH,Spitler CA,Quade JH,Ponce BA,McGwin G Jr,Ghanem ES

    更新日期:2020-09-02 00:00:00

  • The "swashbuckler": a modified anterior approach for fractures of the distal femur.

    abstract::A modified anterior approach to the distal femur is presented. The approach allows surgical exposure of the entire articular surface of the distal femur. The quadriceps muscle bellies are spared during the approach. The skin incision used will not interfere with subsequent total knee arthroplasty, if posttraumatic art...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199902000-00012

    authors: Starr AJ,Jones AL,Reinert CM

    更新日期:1999-02-01 00:00:00

  • Cannulated hip screws: a study of fixation integrity, cut-out resistance, and high-cycle bending fatigue performance.

    abstract::One major advancement in the treatment of femoral neck fractures has been the development of cannulated screws. This study investigates the integrity of five commercially available cannulated screw systems. Transcervical fractures were created in 25 adult femora and repaired by three cannulated hip screws of a randoml...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-199408000-00004

    authors: Rouleau JP,Blasier RB,Tsai E,Goldstein SA

    更新日期:1994-08-01 00:00:00

  • Unstable proximal extraarticular tibia fractures: a biomechanical evaluation of four methods of fixation.

    abstract:OBJECTIVE:To compare the biomechanical stability of extraarticular proximal tibia fractures reconstructed using a double-plate construct, locking plate system, hybrid external fixator, and single lateral periarticular plate, all from the same manufacturer. DESIGN:Standardized proximal tibial fractures (AO classificati...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200409000-00010

    authors: Peindl RD,Zura RD,Vincent A,Coley ER,Bosse MJ,Sims SH

    更新日期:2004-09-01 00:00:00