Biomechanical evaluation of methods of internal fixation of the distal humerus.

Abstract:

:The best results following fractures of the distal humerus are provided by anatomic reduction and rigid internal fixation. Plates of two designs placed in five different fixation configurations were used to determine the construct that would maximize rigidity of fixation of the distal humerus. Using a cadaver distal humerus osteotomy, with and then without cortical contact, motion of the distal fragment was measured with respect to the proximal fragment in axial and torsional loading, anterior to posterior and posterior to anterior bending, and lateral to medial and medial to lateral bending. With cortical contact, two plates when placed medial and lateral or at 90 degrees to each other provided equivalent rigidity. However, with a cortical gap, the combination of a specially designed anatomic lateral buttress "J" plate and a medial reconstruction plate gave the greatest rigidity (ANOVA, p < 0.05). Two-plate constructs do not require placement at 90 degrees to obtain sufficient rigidity, but do require placement on separate bony pillars and different surfaces.

journal_name

J Orthop Trauma

authors

Schemitsch EH,Tencer AF,Henley MB

subject

Has Abstract

pub_date

1994-12-01 00:00:00

pages

468-75

issue

6

eissn

0890-5339

issn

1531-2291

journal_volume

8

pub_type

杂志文章
  • Locking Screws With a Threaded Degradable Polymer Collar Reduce Construct Stiffness Over Time.

    abstract:OBJECTIVES:The stiffness of locking plates provide increased stability for early fracture healing but may limit late interfragmentary motion (IFM) necessary for secondary bone healing. An ideal plating construct would provide early rigidity and late flexibility to optimize bone healing. A novel screw plate construct ut...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001664

    authors: Schultz BJ,Amin NH,Mattison BJ,Mir HR,Shah AR,Cerynik DL

    更新日期:2020-03-01 00:00:00

  • Cadaveric Biomechanical Analysis of 3 Lateral Ulnar Collateral Ligament Reconstructions.

    abstract:OBJECTIVE:To biomechanically assess the angular stability provided by 3 techniques for reconstruction of the lateral ulnar collateral ligament. METHODS:Eight cadaveric elbows were tested with the lateral collateral ligament complex intact, disrupted from the origin at the lateral epicondyle, and reconstructed with 3 d...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001051

    authors: Chauhan A,Baratz ME,Schimoler P,Ruch D,Miller MC

    更新日期:2018-03-01 00:00:00

  • Does the Angle of the Nail Matter for Pertrochanteric Fracture Reduction? Matching Nail Angle and Native Neck-Shaft Angle.

    abstract:OBJECTIVES:To determine whether fixation of pertrochanteric hip fractures with cephalomedullary nails (CMNs) with a neck-shaft angle (NSA) less than the native NSA affects reduction and lag screw cutout. DESIGN:Retrospective comparative study. SETTING:Level I trauma center. PATIENTS/PARTICIPANTS:Patients treated wit...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001096

    authors: Parry JA,Barrett I,Schoch B,Yuan B,Cass J,Cross W

    更新日期:2018-04-01 00:00:00

  • Synovial metallosis resulting from intraarticular intramedullary nailing of a distal femoral nonunion.

    abstract::An 80-year-old man sustained a T-shaped supracondylar fracture of the femur associated with distal one-third shaft comminution. Initial failure of a 95 degrees angle blade plate was followed by insertion of an intraarticular intramedullary nail stabilized with static locking-screw fixation. A second failure of the imp...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199308000-00004

    authors: Johnson EE,Marroquin CE,Kossovsky N

    更新日期:1993-01-01 00:00:00

  • Induced Membrane Technique: Pearls and Pitfalls.

    abstract::The induced membrane technique for reconstruction of bone defects has proved its effectiveness and is now widely accepted. The 2 stages procedure, implying a cement spacer in the first stage and a huge bone graft in the second stage, responds to rigorous technical details involving each phase of the procedure. Prerequ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000979

    authors: Masquelet AC

    更新日期:2017-10-01 00:00:00

  • The "swashbuckler": a modified anterior approach for fractures of the distal femur.

    abstract::A modified anterior approach to the distal femur is presented. The approach allows surgical exposure of the entire articular surface of the distal femur. The quadriceps muscle bellies are spared during the approach. The skin incision used will not interfere with subsequent total knee arthroplasty, if posttraumatic art...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199902000-00012

    authors: Starr AJ,Jones AL,Reinert CM

    更新日期:1999-02-01 00:00:00

  • Lower Extremity Limb Salvage: Lessons Learned From 14 Years at War.

    abstract::American survivability during the current conflicts in Iraq and Afghanistan continues to improve, though the rate of extremity injury remains quite high. The decision to proceed with amputation versus limb salvage remains controversial. Exposure to combat wound with severe high-energy lower extremity trauma during the...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000669

    authors: Blair JA,Eisenstein ED,Pierrie SN,Gordon W,Owens JG,Hsu JR

    更新日期:2016-10-01 00:00:00

  • Accuracy study of computer-assisted drilling: the effect of bone density, drill bit characteristics, and use of a mechanical guide.

    abstract:OBJECTIVE:This study was designed to determine the clinical relevant accuracy of CT-based navigation for drilling. DESIGN:Experimental model. SETTING:Laboratory. METHODS:Twelve drills of varying lengths and diameters were tested with 2 different set-ups. Group 1 used free-hand navigated drilling technique with foam ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Hüfner T,Geerling J,Oldag G,Richter M,Kfuri M Jr,Pohlemann T,Krettek C

    更新日期:2005-05-01 00:00:00

  • Far Cortical Locking Fixation of Distal Femur Fractures is Dominated by Shear at Clinically Relevant Bridge Spans.

    abstract:OBJECTIVES:Far cortical locking (FCL) constructs have been shown to increase axial interfragmentary displacement while limiting shear and have been specifically recommended in the treatment of distal femur fractures. However, there is no available data regarding their mechanical behavior within the range of bridge span...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001341

    authors: Habet N,Elkins J,Peindl R,Killen C,Lack WD

    更新日期:2019-02-01 00:00:00

  • A method for detection of lateral malleolar malrotation using conventional fluoroscopy.

    abstract::Recent studies on ankle syndesmosis injuries have shown that a significant amount of rotational malediction of the distal fibula are missed and may lead to poor functional outcome. A new set of radiographic criteria were developed to help detect distal fibula internal and external rotation using conventional fluorosco...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31828f89a9

    authors: Marmor M,Kandemir U,Matityahu A,Jergesen H,McClellan T,Morshed S

    更新日期:2013-12-01 00:00:00

  • Operating room efficiency: benefits of an orthopaedic traumatologist at a level II trauma center.

    abstract:OBJECTIVES:Fellowship-trained orthopaedic traumatologists are presumably taught skill sets leading to "best practice" outcomes and more efficient use of hospital resources. This should result in more favorable economic opportunities when compared with general orthopaedic surgeons (GOSs) providing similar clinical servi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a59d6b

    authors: Althausen PL,Kauk JR,Shannon S,Lu M,O'Mara TJ,Bray TJ

    更新日期:2014-05-01 00:00:00

  • Optimal Technical Factors During Operative Management of Low-Energy Femoral Neck Fractures.

    abstract:OBJECTIVE:To determine if cancellous screw (CS) and sliding hip screw (SHS) technical factors during low-energy femoral neck fracture fixation affects a 24-month revision surgery rate and health-related quality of life (HRQL). DESIGN:Prospective randomized controlled study. SETTING:International, multicenter. PATIEN...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001891

    authors: Schottel PC,Blankstein M,Sprague S,Swiontkowski M,Bzovsky S,Bhandari M,Schemitsch EH,FAITH Investigators.

    更新日期:2021-02-01 00:00:00

  • Biomechanical Assessment of Locking Plate Fixation of Comminuted Proximal Olecranon Fractures.

    abstract:OBJECTIVES:To determine if mean ultimate strength or failure mechanism differed between comminuted olecranon fractures created at the proximal 25% or 50% of the trochlear notch and fixed with precontoured posterior locking plates (PLPs). METHODS:Comminuted osteotomies were created in 10 matched pairs of cadaveric uppe...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001279

    authors: Fantry A,Sobel A,Capito N,Hodax JD,Pidgeon T,Koruprolu S,Rich R,Fava JL,Green A,Paxton S

    更新日期:2018-11-01 00:00:00

  • Locking plates for distal femur fractures: is there a problem with fracture healing?

    abstract:OBJECTIVES:Fractures of the distal femur are severe injuries that present many clinical challenges. Nonunion, delayed union, implant failure, and the need for secondary procedures can reflect complications of healing. This article reviews the literature on distal femur fractures treated with locking plates to determine...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e3182070127

    authors: Henderson CE,Kuhl LL,Fitzpatrick DC,Marsh JL

    更新日期:2011-02-01 00:00:00

  • Amputations through the hind foot: a report of three cases using a modified Dwyer and Paul procedure.

    abstract::Salvage of limb length following oblique proximal foot amputations is presented. The technique, results, and follow-up of this procedure are described and compared with other standard procedures. A prospective study was done on 3 adolescents who presented consecutively during years 1999 and 2000. The salvage procedure...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000164168.94365.49

    authors: Dwyer AJ,Paul R,Gosselin RA

    更新日期:2005-04-01 00:00:00

  • Extra-articular malunions of the scapula: a comparison of functional outcome before and after reconstruction.

    abstract:OBJECTIVE:To assess surgical and functional results after corrective reconstruction of malunited, scapula neck or body fractures in patients who presented with chronic pain, limited range of motion, weakness, and gross deformity of the shoulder. DESIGN:Case series. SETTING:Level I teaching trauma center. PATIENTS:Be...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31820af67f

    authors: Cole PA,Talbot M,Schroder LK,Anavian J

    更新日期:2011-11-01 00:00:00

  • Uniplanar Osteotomy for Multiplanar Femoral Deformity Correction.

    abstract::Long-bone deformity may be significantly symptomatic. A uniplanar corrective osteotomy uses a single cut to correct coronal, sagittal, and axial plane deformity simultaneously. Careful preoperative planning is required in addition to a comprehensive understanding of the magnitude and plane of the true deformity of the...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001519

    authors: Medda S,Jinnah AH,Marquez-Lara A,Araiza ET,Carroll EA

    更新日期:2019-08-01 00:00:00

  • The Effect of Shelter-in-Place Orders and the COVID-19 Pandemic on Orthopaedic Trauma at a Community Level II Trauma Center.

    abstract:OBJECTIVES:Evaluate the effect of the COVID-19 pandemic and the "shelter-in-place" order on orthopaedic trauma presenting to a community level II trauma center. It is hypothesized the overall number of orthopaedic trauma encounters (OTE), the number of OTEs related to both high and low severity injuries, as well as the...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001860

    authors: Stoker S,McDaniel D,Crean T,Maddox J,Jawanda G,Krentz N,Best J,Speicher M,Siwiec R

    更新日期:2020-06-08 00:00:00

  • The Clinical Utility of Additional Axillary and Velpeau Radiographs in the Evaluation of Suspected Shoulder Trauma.

    abstract:OBJECTIVES:To investigate the clinical utility of additional axillary or Velpeau views in evaluating potential shoulder trauma after a standard radiograph series of anteroposterior, Grashey, and/or trans-scapular views. DESIGN:Retrospective study. SETTING:Level I academic medical center. PATIENTS:All patients in a 1...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001760

    authors: Cruz SA,Castillo H,Chintapalli RTV,Adams OE,Morgan VK,Koh JL,Lee MJ,Shi LL

    更新日期:2020-08-01 00:00:00

  • Use of the Medoff sliding plate for subtrochanteric hip fractures.

    abstract:OBJECTIVE:To evaluate the effects of dynamization of a sliding hip screw plate on the fixation stability for several types of subtrochanteric fractures. Clinical results of treating reverse oblique fractures occasionally show medialization of the femoral shaft. DESIGN:Two types of plate dynamization were compared usin...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199704000-00007

    authors: Kummer FJ,Pearlman CA,Koval KJ,Ceder L

    更新日期:1997-04-01 00:00:00

  • Arthroplasty Versus Internal Fixation for the Treatment of Undisplaced Femoral Neck Fractures: A Retrospective Cohort Study.

    abstract:OBJECTIVE:To compare the 24-month risk of mortality between arthroplasty and internal fixation for undisplaced femoral neck fractures (FNFs). DESIGN:Retrospective cohort study. SETTING:Secondary data analysis of 2 multinational randomized controlled trials. PARTICIPANTS:Patients aged 50 years or older with a FNF. I...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001940

    authors: Afaq S,OʼHara NN,Schemitsch EH,Bzovsky S,Sprague S,Poolman RW,Frihagen F,Heels-Ansdell D,Bhandari M,Swiontkowski M,Slobogean GP,FAITH Investigators.,HEALTH Investigators.

    更新日期:2020-11-01 00:00:00

  • Gravity Stress Radiographs and the Effect of Ankle Position on Deltoid Ligament Integrity and Medial Clear Space Measurements.

    abstract:INTRODUCTION:External rotation and gravity stress radiographs have been described to distinguish stable supination-external rotation-II (SER-II) ankle fractures from unstable SER-IV fractures. It has been previously shown that both external rotation and gravity stress views are equivalent in their ability to diagnose d...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000817

    authors: Ashraf A,Murphree J,Wait E,Winston T,Wooldridge A,Meriwether M,Wilson J,Grimes JS

    更新日期:2017-05-01 00:00:00

  • Orthopaedic trauma and the evolution of healthcare policy in America.

    abstract::Healthcare policy has changed drastically, and with the 50-year anniversary of the passage of Medicare approaching in 2015, the authors evaluate the development of the current healthcare system and its relationship to the development of modern orthopaedic trauma. With more changes in healthcare policy forthcoming, it ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000214

    authors: Mitchell PM,Thakore R,Obremskey A,Sethi MK

    更新日期:2014-10-01 00:00:00

  • Bone regeneration with resorbable polymeric membranes: treatment of diaphyseal bone defects in the rabbit radius with poly(L-lactide) membrane. A pilot study.

    abstract::Tubular poly(L-lactide) membranes with a pore size of 5-15 microns and a molecular weight of 70,000 Daltons were implanted into 24 New Zealand skeletally mature rabbits to cover 10-mm mid-diaphyseal defects of the radius of the forelimb. An identical defect on the contralateral limb was not treated with the membrane a...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199604000-00006

    authors: Meinig RP,Rahn B,Perren SM,Gogolewski S

    更新日期:1996-01-01 00:00:00

  • Treatment of displaced, proximal, humeral, epiphyseal fractures with a two-prong splint.

    abstract::To evaluate the use of a two-prong splint for displaced, proximal, humerus, epiphyseal fractures, seven children with Neer-Horwitz Classification Type 3-4 fractures of the proximal humerus were retrospectively investigated. After closed reduction, fracture stabilization was accomplished with the use of a two-prong spl...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200309000-00007

    authors: Karatosun V,Unver B,Alici E,Serin E

    更新日期:2003-09-01 00:00:00

  • A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates.

    abstract:OBJECTIVES:To examine the biomechanical behavior of 2 techniques of double-plate osteosynthesis for fractures of the adult distal humerus using conventional reconstruction plates and locking compression plates. DESIGN:Basic science study. SETTING:Experimental in vitro study. PATIENTS/PARTICIPANTS:Forty fresh-frozen ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200405000-00004

    authors: Korner J,Diederichs G,Arzdorf M,Lill H,Josten C,Schneider E,Linke B

    更新日期:2004-05-01 00:00:00

  • Biomechanical Comparison of Cadaveric and Commercially Available Synthetic Osteoporotic Bone Analogues in a Locked Plate Fracture Model Under Torsional Loading.

    abstract:OBJECTIVES:Biomechanical studies of osteoporotic bone have used synthetic models rather than cadaveric samples because of decreased variability, increased availability, and overall ease of the use of synthetic models. We compared the torsional mechanical properties of cadaveric osteoporotic bone with those of currently...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000782

    authors: Becker EH,Kim H,Shorofsky M,Hsieh AH,Watson JD,OʼToole RV

    更新日期:2017-05-01 00:00:00

  • The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures.

    abstract:OBJECTIVES:The purpose of this study was to evaluate forearm rotation after volar plating of the distal radius fractures with and without pronator quadratus repair. DESIGN:This was an institutional review board-approved retrospective review of prospectively collected data. SETTING:The study was conducted at an Academ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182539333

    authors: Hershman SH,Immerman I,Bechtel C,Lekic N,Paksima N,Egol KA

    更新日期:2013-03-01 00:00:00

  • Functional outcomes in women after high-energy pelvic ring injury.

    abstract:OBJECTIVES:Residual dysfunction after pelvic trauma has been previously described, but limited functional outcome data are available in the female population after high-energy pelvic ring injury. The purposes of this study were to determine functional outcomes and to characterize factors predictive of outcome. DESIGN:...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318221e94e

    authors: Vallier HA,Cureton BA,Schubeck D,Wang XF

    更新日期:2012-05-01 00:00:00

  • The trochanteric C-clamp for provisional pelvic stability.

    abstract::The application of a pelvic clamp for provisional stability of unstable pelvic fractures has been advocated in the orthopaedic literature. Although the technique has gained some supporters, problems with placement and associated complications have prevented widespread acceptance. We have modified the pelvic clamp (ACE...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000175156.92743.db

    authors: Archdeacon MT,Hiratzka J

    更新日期:2006-01-01 00:00:00