A method for detection of lateral malleolar malrotation using conventional fluoroscopy.

Abstract:

:Recent studies on ankle syndesmosis injuries have shown that a significant amount of rotational malediction of the distal fibula are missed and may lead to poor functional outcome. A new set of radiographic criteria were developed to help detect distal fibula internal and external rotation using conventional fluoroscopy. The criteria were tested using a cadaveric model for Weber C ankle fractures fixed with the fibula in various degrees of internal and external rotation. Using the criteria orthopaedic trauma surgeons were able to improve their accuracy and agreement on assessment of degree and direction of fibula rotation.

journal_name

J Orthop Trauma

authors

Marmor M,Kandemir U,Matityahu A,Jergesen H,McClellan T,Morshed S

doi

10.1097/BOT.0b013e31828f89a9

subject

Has Abstract

pub_date

2013-12-01 00:00:00

pages

e281-4

issue

12

eissn

0890-5339

issn

1531-2291

journal_volume

27

pub_type

杂志文章
  • Treatment of unstable peritrochanteric fractures in elderly patients with a compression hip screw or with the Vandeputte (VDP) endoprosthesis: a prospective randomized study.

    abstract::A prospective randomized study was set up, comparing a compression hip screw with the Vandeputte (VDP) endoprosthesis treatment for fresh, unstable peritrochanteric fractures, according to the Evans-Jensen and AO systems. Ninety patients, ages > or = 70 years, 47 of whom were treated with a compression hip screw and 4...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-199509040-00004

    authors: Stappaerts KH,Deldycke J,Broos PL,Staes FF,Rommens PM,Claes P

    更新日期:1995-01-01 00:00:00

  • A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates.

    abstract:OBJECTIVES:To examine the biomechanical behavior of 2 techniques of double-plate osteosynthesis for fractures of the adult distal humerus using conventional reconstruction plates and locking compression plates. DESIGN:Basic science study. SETTING:Experimental in vitro study. PATIENTS/PARTICIPANTS:Forty fresh-frozen ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200405000-00004

    authors: Korner J,Diederichs G,Arzdorf M,Lill H,Josten C,Schneider E,Linke B

    更新日期:2004-05-01 00:00:00

  • Treatment of diaphyseal fractures of the humerus using a functional brace.

    abstract:OBJECTIVE:To determine humeral diaphyseal fractures at risk for nonunion with functional brace treatment. DESIGN:Retrospective case series. SETTING:A single surgeon's practice. PATIENTS:Forty-nine of 52 consecutive patients treated nonoperatively for an isolated diaphyseal fracture of the humerus during a 6-year per...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000249423.48074.82

    authors: Rutgers M,Ring D

    更新日期:2006-10-01 00:00:00

  • Nonoperative treatment of intermediate severity lateral compression type 1 pelvic ring injuries with minimally displaced complete sacral fracture.

    abstract:OBJECTIVES:Controversy exists regarding optimum management of lateral compression type 1 (LC1) pelvic ring injuries (OTA type 61-B2.1), particularly in patients with complete sacral fractures. We hypothesized that nonoperative treatment would result in acceptable functional outcomes. DESIGN:Database review. SETTING:L...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000130

    authors: Gaski GE,Manson TT,Castillo RC,Slobogean GP,OʼToole RV

    更新日期:2014-12-01 00:00:00

  • Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures.

    abstract:OBJECTIVE:Comparison between a Less Invasive Stabilization System (LISS) using monocortical screws with angular stability and two conventional plate systems Condylar Buttress Plate (CBP) and Dynamic Condylar Screw (DCS) for the treatment of distal femoral fractures with respect to biomechanical properties. DESIGN:Biom...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200109000-00004

    authors: Marti A,Fankhauser C,Frenk A,Cordey J,Gasser B

    更新日期:2001-09-01 00:00:00

  • A mechanical comparison of the locking compression plate (LCP) and the low contact-dynamic compression plate (DCP) in an osteoporotic bone model.

    abstract:OBJECTIVE:To determine if locking compression plates (LCP) are mechanically advantageous compared to low-contact dynamic compression plates (DCP) when used as a bridging plate in a synthetic model of osteoporotic bone. METHODS:Five synthetic bars (Synbone Osteoporotic bone) were initially tested in compression and the...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318160c84c

    authors: Snow M,Thompson G,Turner PG

    更新日期:2008-02-01 00:00:00

  • Surgical treatment of a displaced lateral malleolus fracture: the antiglide technique versus lateral plate fixation.

    abstract:OBJECTIVES:To assess the outcomes of the surgical management of "isolated" displaced lateral malleolar fractures, comparing the techniques of lateral plating and antiglide plating as described previously. DESIGN:This is a retrospective review, being largely a surgeon-randomized comparative study. SETTING:The study wa...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200208000-00008

    authors: Lamontagne J,Blachut PA,Broekhuyse HM,O'Brien PJ,Meek RN

    更新日期:2002-08-01 00:00:00

  • Management of severe musculoskeletal injuries of the upper extremity.

    abstract::Limb salvage was successful in 25 patients treated for severe grade III upper extremity injuries. In a retrospective review of 20 men and five women, follow-up time averaged 26 months. These high-energy injuries were characterized by massive soft-tissue injury, highly comminuted fractures, and significant neurovascula...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Levin LS,Goldner RD,Urbaniak JR,Nunley JA,Hardaker WT Jr

    更新日期:1990-01-01 00:00:00

  • Posteromedial Approach to Tibial Plateau Fracture Nonunion.

    abstract::Tibial plateau fractures can involve planes that require reduction and stabilization from a posterior approach. This includes posteromedial, posterolateral, and posterior column shear type injuries. This video outlines the prone posteromedial approach to the tibial plateau for posterior column fracture exposure, reduc...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001826

    authors: Shields CN,Eftekhary N,Egol KA

    更新日期:2020-08-01 00:00:00

  • Character, Incidence, and Predictors of Knee Pain and Activity After Infrapatellar Intramedullary Nailing of an Isolated Tibia Fracture.

    abstract:OBJECTIVE:To study the activity and incidence of knee pain after sustaining an isolated tibia fracture treated with an infrapatellar intramedullary nail at 1 year. DESIGN:Retrospective review of prospective cohort. SETTING:Multicenter Academic and Community hospitals. PATIENTS:Four hundred thirty-seven patients with...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000000475

    authors: Obremskey W,Agel J,Archer K,To P,Tornetta P 3rd,SPRINT Investigators.

    更新日期:2016-03-01 00:00:00

  • Do locking screws work in plates bent at holes?

    abstract:OBJECTIVES:To assess whether plate bending at a hole significantly changes the biomechanical properties of a locked screw. METHODS:Coronal plane bends of 5-, 15-, or 45-degree angles were placed in 3.5-mm locking compression plates with the apex at a locking hole. An additional 45-degree angle test group was created i...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a73a77

    authors: Boulton CL,Kim H,Shah SB,Ryan SP,Metzger TA,Hsieh AH,O'Toole RV

    更新日期:2014-04-01 00:00:00

  • Small-incision surgical exposure for select fractures of the acetabulum: the gluteus maximus-splitting approach.

    abstract::This technique article presents a small-incision, gluteal-splitting approach for the treatment of select fractures involving the posterior acetabulum. The approach essentially involves the proximal portion of the Kocher-Langenbeck incision, and it can be extended to a larger exposure if needed. It is ideally suited fo...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000211143.70424.f7

    authors: Carr JB,Leach PB

    更新日期:2006-09-01 00:00:00

  • Management of Simultaneous Patellar Tendon and Anterior Cruciate Ligament Ruptures-A Systematic Review of Available Literature.

    abstract:BACKGROUND:Combined rupture of the anterior cruciate ligament (ACL) and patellar tendon (PT) is a rare injury pattern. Currently, little evidence exists to help guide management decisions for these patients. METHODS:A systematic literature search was conducted using PubMed (MEDLINE) and Scopus (EMBASE and MEDLINE) for...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001219

    authors: Matthews AH,Fraser EJ,Parkinson B

    更新日期:2018-08-01 00:00:00

  • Extracorporeal shock wave therapy: current evidence.

    abstract:OBJECTIVES:The aim of this article is to provide a concise review of the basic science of extracorporeal shock wave therapy (ESWT) and to perform a systematic review of the literature for the use of ESWT in the treatment of fractures and delayed unions/nonunions. DATA SOURCES:Articles in the English or German language...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,meta分析,评审

    doi:10.1097/BOT.0b013e3181cad510

    authors: Zelle BA,Gollwitzer H,Zlowodzki M,Bühren V

    更新日期:2010-03-01 00:00:00

  • Getting organized in your job.

    abstract::The benefits of being organized when starting one's career are countless and worth the time and effort in developing an effective and efficient practice. Established protocols, good habits, and methodical communication that include all members of the team will help create a system that keeps all components of one's pr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a52344

    authors: Siegel J

    更新日期:2013-10-01 00:00:00

  • Orthopaedic Trauma Association Annual Meeting Program Committee: Analysis of Impact of Committee Size and Review Process on Abstract Acceptance.

    abstract:OBJECTIVE:To evaluate whether scientific abstracts selected for podium presentation at the Orthopaedic Trauma Association (OTA) Annual Meeting differ based on the program committee size and/or the proportion of abstracts each committee member evaluates. METHODS:Abstract scores from the Orthopaedic Trauma Association p...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001108

    authors: OʼHara NN,Slobogean GP,Zhan M,Gardner MJ,McKee MD,Moore SM,Higgins TF,OʼToole RV,Orthopaedic Trauma Association Program Committee.

    更新日期:2018-05-01 00:00:00

  • Closed reduction and minimally invasive percutaneous fixation of proximal humerus fractures using the Humerusblock.

    abstract:OBJECTIVE:To evaluate the results after closed reduction and percutaneous fixation of displaced fractures of the proximal humerus with the Humerusblock system. DESIGN:Prospective case series. SETTING:Level 1 trauma center. PATIENTS AND METHODS:Fifty-eight consecutive patients with displaced proximal humerus fracture...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181c81b1c

    authors: Brunner A,Weller K,Thormann S,Jöckel JA,Babst R

    更新日期:2010-07-01 00:00:00

  • Modified Technique of Separate Vertical Wiring for the Fixation of Patellar Inferior Pole Fracture.

    abstract::To evaluate the biomechanical and clinical results of modified separate vertical wiring technique (SVW) for inferior pole patellar fracture repair we conducted a finite element biomechanical study using 2 fixation methods and evaluated a clinical series of eleven patients. The modified SVW technique was an effective, ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001080

    authors: He S,Huang X,Yan B,Zhu J,Bao N,Zhao J

    更新日期:2018-04-01 00:00:00

  • Modified Judet approach and minifragment fixation of scapular body and glenoid neck fractures.

    abstract:OBJECTIVES:To describe the technique and to determine the outcome of operatively treated displaced scapular body or glenoid neck fractures using minifragment fixation through a modified Judet approach. DESIGN:Retrospective review of scapular or glenoid fractures. SETTING:Level 1 teaching trauma center. PATIENTS:All ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181a18216

    authors: Jones CB,Cornelius JP,Sietsema DL,Ringler JR,Endres TJ

    更新日期:2009-09-01 00:00:00

  • Trauma program development.

    abstract::The development of a strong trauma program is clearly one of the most important facets of successful business development. Several recent publications have demonstrated that well run trauma services can generate significant profits for both the hospital and the surgeons involved. There are many aspects to this task th...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000142

    authors: Althausen PL

    更新日期:2014-07-01 00:00:00

  • Locking plates for distal femur fractures: is there a problem with fracture healing?

    abstract:OBJECTIVES:Fractures of the distal femur are severe injuries that present many clinical challenges. Nonunion, delayed union, implant failure, and the need for secondary procedures can reflect complications of healing. This article reviews the literature on distal femur fractures treated with locking plates to determine...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e3182070127

    authors: Henderson CE,Kuhl LL,Fitzpatrick DC,Marsh JL

    更新日期:2011-02-01 00:00:00

  • Unexpected high complication rate following internal fixation of unstable proximal humerus fractures with an angled blade plate.

    abstract:OBJECTIVES:The increasing number of fractures of the proximal humerus, especially in the elderly, carries with it the unsolved problem of the optimal treatment for the displaced or unstable fractures. The authors' goal was to analyze whether fixation with a bent valgus angled blade plate could improve the outcomes repo...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200604000-00004

    authors: Meier RA,Messmer P,Regazzoni P,Rothfischer W,Gross T

    更新日期:2006-04-01 00:00:00

  • The sequential recovery of health status after tibial plafond fractures.

    abstract:OBJECTIVES:To assess the recovery of ankle function and general health status at multiple time points during the first 24 months after an isolated tibial plafond fracture treated with joint-spanning external fixation and to determine factors that affect a rapid versus a slow recovery and factors that influence patient ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181c8ad52

    authors: Marsh JL,McKinley T,Dirschl D,Pick A,Haft G,Anderson DD,Brown T

    更新日期:2010-08-01 00:00:00

  • The thermal effects of intramedullary reaming.

    abstract:OBJECTIVE:To study the effect of tourniquet control on intramedullary reaming. DESIGN:An experimental prospective nonsurvival animal study was performed using 5 mongrel dogs. A pneumatic tourniquet was randomized to either the right or left hind limb. Tibial intramedullary reaming was performed with progressively larg...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200411000-00004

    authors: Karunakar MA,Frankenburg EP,Le TT,Hall J

    更新日期:2004-11-01 00:00:00

  • Spinal Cord Injury-What Are the Controversies?

    abstract::Traumatic spinal cord injuries have a tremendous impact on individuals, families, and society as a whole. Substantial heterogeneity in the patient population, their presentation and underlying pathophysiology has sparked debates along the care spectrum from initial assessment to definitive treatment. This article revi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000943

    authors: Ahuja CS,Schroeder GD,Vaccaro AR,Fehlings MG

    更新日期:2017-09-01 00:00:00

  • Biomechanical Assessment of Locking Plate Fixation of Comminuted Proximal Olecranon Fractures.

    abstract:OBJECTIVES:To determine if mean ultimate strength or failure mechanism differed between comminuted olecranon fractures created at the proximal 25% or 50% of the trochlear notch and fixed with precontoured posterior locking plates (PLPs). METHODS:Comminuted osteotomies were created in 10 matched pairs of cadaveric uppe...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001279

    authors: Fantry A,Sobel A,Capito N,Hodax JD,Pidgeon T,Koruprolu S,Rich R,Fava JL,Green A,Paxton S

    更新日期:2018-11-01 00:00:00

  • The Size of Intramedullary Fixation Affects Endochondral-Mediated Angiogenesis During Fracture Repair.

    abstract:OBJECTIVES:To explore the effect of intramedullary pin size on the biology of a healing fracture, specifically endochondral angiogenesis. We hypothesized that fracture fixation with a smaller pin would permit greater interfragmentary strain resulting in increased total amount of vascular endothelial growth factor withi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001555

    authors: Yuasa M,Saito M,Blum DM,Hysong AA,Egawa S,Uppuganti S,Yoshii T,Okawa A,Schwartz HS,Moore-Lotridge SN,Nyman JS,Schoenecker JG

    更新日期:2019-10-01 00:00:00

  • Thrombin Hemostatic Matrix Reduces Heterotopic Ossification in Acetabular Fractures Fixed Through the Kocher-Langenbeck Approach.

    abstract:OBJECTIVE:To determine whether an injectable thrombin product [thrombin hemostatic matrix (THM)] at closure of a Kocher-Langenbeck approach reduces the risk of heterotopic ossification (HO) formation after an acetabular fracture. DESIGN:Case control. SETTING:Two Level 1 trauma centers. PATIENTS:Patients with operati...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001783

    authors: Montgomery T,Pearson J,Agarwal A,Olinger C,Tobey D,Beebe M,McGwin G,Cichos K,Ghanem E,Spitler C,Dubose C,Quade J

    更新日期:2020-09-01 00:00:00

  • Definitive Management of Distal Tibia and Simple Plafond Fractures With Circular External Fixation.

    abstract::Obtaining optimal results in the treatment of extraarticular distal tibia fractures can be challenging. Plate and screw and intramedullary fixation have proven to be effective treatments, but are associated with significant complication rates when used for open fractures and patient with severe medical comorbidities. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000694

    authors: Quinnan SM

    更新日期:2016-11-01 00:00:00

  • Volar radiocarpal dislocation with ulnar translocation.

    abstract::The first known reported case of volar radiocarpal dislocation with ulnar translocation is described with a review of previous literature on the isolated components of these injuries. Radiographic criteria for their diagnosis are presented with recommendations for early operative intervention to minimize the risk of s...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/00005131-198802040-00009

    authors: Penny WH 3rd,Green TL

    更新日期:1988-01-01 00:00:00