Synovial metallosis resulting from intraarticular intramedullary nailing of a distal femoral nonunion.

Abstract:

:An 80-year-old man sustained a T-shaped supracondylar fracture of the femur associated with distal one-third shaft comminution. Initial failure of a 95 degrees angle blade plate was followed by insertion of an intraarticular intramedullary nail stabilized with static locking-screw fixation. A second failure of the implant was treated by extraarticular tension band condylar buttress plate osteosynthesis. Severe knee synovial metallosis was found at the time of removal of the intraarticular nail device.

journal_name

J Orthop Trauma

authors

Johnson EE,Marroquin CE,Kossovsky N

doi

10.1097/00005131-199308000-00004

subject

Has Abstract

pub_date

1993-01-01 00:00:00

pages

320-4; discussion 325-6

issue

4

eissn

0890-5339

issn

1531-2291

journal_volume

7

pub_type

杂志文章
  • Teamwork in Trauma: System Adjustment to a Protocol for the Management of Multiply Injured Patients.

    abstract:OBJECTIVES:We developed a protocol to determine the timing of definitive fracture care based on the adequacy of resuscitation. Inception of this project required a multidisciplinary group, including physicians from anesthesiology, general trauma and critical care, neurosurgery, orthopaedic spine, and orthopaedic trauma...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000383

    authors: Vallier HA,Moore TA,Como JJ,Dolenc AJ,Steinmetz MP,Wagner KG,Smith CE,Wilczewski PA

    更新日期:2015-11-01 00:00:00

  • Levels of Evidence in Orthopaedic Trauma Literature.

    abstract:OBJECTIVE:To review and critically assess trends observed regarding the levels of evidence in published articles in orthopaedic traumatology literature. DATA SOURCES:The Journal of Orthopaedic Trauma, Journal of Bone and Joint Surgery-American, and Clinical Orthopaedics and Related Research. STUDY SELECTION:All artic...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000557

    authors: Scheschuk JP,Mostello AJ,Lombardi NJ,Maltenfort MG,Freedman KB,Tjoumakaris FP

    更新日期:2016-07-01 00:00:00

  • Treatment preferences for displaced three- and four-part proximal humerus fractures.

    abstract:OBJECTIVES:To assess the treatment preferences of orthopaedic surgeons for displaced three- and four-part proximal humerus fractures. DESIGN:Cross-sectional survey. SETTING:Academic and nonacademic institutions across Canada. PATIENTS/PARTICIPANTS:Members of the Canadian Orthopedic Trauma Society and the Joint Ortho...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181bdc46a

    authors: Guy P,Slobogean GP,McCormack RG

    更新日期:2010-04-01 00:00:00

  • Comparison of the 95-degree angled blade plate and the locking condylar plate for the treatment of distal femoral fractures.

    abstract:OBJECTIVES:In the distal femur, locked plating is efficacious when coronal fractures preclude the use of a conventional fixed-angle device. However, minimal comparative data exist for supracondylar fracture patterns, which could be treated with other devices. The purpose of this study was to compare the 95-degree angle...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318234d460

    authors: Vallier HA,Immler W

    更新日期:2012-06-01 00:00:00

  • Percutaneous pelvic fixation using working portals in a circumferential pelvic antishock sheet.

    abstract::Unstable pelvic ring injuries are associated with an increased mortality rate, most commonly from severe hemorrhage. Circumferential pelvic antishock sheeting has proven effective for rapidly stabilizing the pelvic ring and has become an integral part of resuscitation protocols. Acute antishock sheet placement frequen...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181a87c6c

    authors: Gardner MJ,Osgood G,Molnar R,Chip Routt ML Jr

    更新日期:2009-10-01 00:00:00

  • An investigation of the contribution of the extraosseous tissues to the diaphyseal fracture callus using a rabbit tibial fracture model and in situ immunocytochemical localisation of osteocalcin.

    abstract::The extraosseous tissue contribution to diaphyseal fracture callus has been investigated using a rabbit tibial fracture model and osteocalcin immunocytochemistry. The extraosseous tissues were isolated for study by reaming and nailing an osteotomy and excising 2 cm of periosteum on either side of the osteotomy. Specim...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199206000-00010

    authors: Stafford H,Oni OO,Hay J,Gregg PJ

    更新日期:1992-01-01 00:00:00

  • Modern Results of Functional Bracing of Humeral Shaft Fractures: A Multicenter Retrospective Analysis.

    abstract:OBJECTIVES:To evaluate the rate of, and reasons for, conversion of closed treatment of humeral shaft fractures using a fracture brace, to surgical intervention. DESIGN:Multicenter, retrospective analysis. SETTING:Nine Level 1 trauma centers across the United States. PATIENTS:A total of 1182 patients with a closed hu...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001666

    authors: Serrano R,Mir HR,Sagi HC,Horwitz DS,Borade A,Ketz JP,Kistler BJ,Quade JH,Beebe MJ,Au BK,Sanders RW,Shah AR

    更新日期:2020-04-01 00:00:00

  • Femoral nerve palsy after pelvic fracture treated with INFIX: a case series.

    abstract:OBJECTIVE:The treatment of some pelvic injuries has evolved recently to include the use of a subcutaneous anterior pelvic fixator (INFIX). We present 8 cases of femoral nerve palsy in 6 patients after application of an INFIX to highlight this potentially devastating complication to pelvic surgeons using this technique ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000193

    authors: Hesse D,Kandmir U,Solberg B,Stroh A,Osgood G,Sems SA,Collinge CA

    更新日期:2015-03-01 00:00:00

  • A mechanical comparison of the locking compression plate (LCP) and the low contact-dynamic compression plate (DCP) in an osteoporotic bone model.

    abstract:OBJECTIVE:To determine if locking compression plates (LCP) are mechanically advantageous compared to low-contact dynamic compression plates (DCP) when used as a bridging plate in a synthetic model of osteoporotic bone. METHODS:Five synthetic bars (Synbone Osteoporotic bone) were initially tested in compression and the...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318160c84c

    authors: Snow M,Thompson G,Turner PG

    更新日期:2008-02-01 00:00:00

  • Treatment of diaphyseal fractures of the humerus using a functional brace.

    abstract:OBJECTIVE:To determine humeral diaphyseal fractures at risk for nonunion with functional brace treatment. DESIGN:Retrospective case series. SETTING:A single surgeon's practice. PATIENTS:Forty-nine of 52 consecutive patients treated nonoperatively for an isolated diaphyseal fracture of the humerus during a 6-year per...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000249423.48074.82

    authors: Rutgers M,Ring D

    更新日期:2006-10-01 00:00:00

  • Alleviation of Pain After Femur and Tibia Shaft Fractures Using Nothing Stronger Than Codeine and Tramadol.

    abstract:OBJECTIVE:To determine whether using nothing stronger than codeine and tramadol provides adequate pain alleviation in people recovering from fixation of a fracture of the femur or tibia shaft. DESIGN:Retrospective case series. SETTING:Level 1 trauma center in the United States. PATIENTS:All adult patients from Octob...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001683

    authors: Reich MS,Klahs KJ,Fernandez I,Nguyen MP

    更新日期:2020-02-01 00:00:00

  • Inflammation, Bone Healing, and Anti-Inflammatory Drugs: An Update.

    abstract::Fracture healing is a unique multifaceted process requiring the presence of cells, molecular mediators, and angiogenic factors. The state of inflammation dominates the initial phase, but the ideal magnitude and duration of the process for an optimal outcome remains obscure. Biological response modifiers, such as plate...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000465

    authors: Giannoudis PV,Hak D,Sanders D,Donohoe E,Tosounidis T,Bahney C

    更新日期:2015-12-01 00:00:00

  • Syndesmotic instability in Weber B ankle fractures: a clinical evaluation.

    abstract:OBJECTIVE:Syndesmotic instability may coexist with unstable Weber B supination-external rotation (SE) lateral malleolar fractures. Current recommendations suggest that Weber B injuries should not have associated syndesmotic instability after open reduction and internal fixation of the lateral malleolus. The purpose of ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318157a63a

    authors: Stark E,Tornetta P 3rd,Creevy WR

    更新日期:2007-10-01 00:00:00

  • Split depression tibial plateau fractures: a biomechanical study.

    abstract:OBJECTIVE:To determine the biomechanical characteristics of four different fixation constructs for split depression fractures of the lateral tibial plateau (OTA classification 41B3.1). DESIGN:Laboratory investigation using a cadaveric simulated split depression tibial plateau fracture model. SETTING:Split depression ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200203000-00006

    authors: Karunakar MA,Egol KA,Peindl R,Harrow ME,Bosse MJ,Kellam JF

    更新日期:2002-03-01 00:00:00

  • Concurrent dorsal dislocations and fracture-dislocations of the index, long, ring, and small (second to fifth) carpometacarpal joints.

    abstract:OBJECTIVE:To review the outcome of patients with concurrent dorsal dislocations and fracture-dislocations of the second, third, fourth, and fifth carpometacarpal (CMC) joints treated with open reduction and internal fixation (ORIF). DESIGN:Retrospective review. SETTING:Level 1 trauma center. PATIENTS:Between 1991 an...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200111000-00003

    authors: Prokuski LJ,Eglseder WA Jr

    更新日期:2001-11-01 00:00:00

  • Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures.

    abstract:OBJECTIVE:Comparison between a Less Invasive Stabilization System (LISS) using monocortical screws with angular stability and two conventional plate systems Condylar Buttress Plate (CBP) and Dynamic Condylar Screw (DCS) for the treatment of distal femoral fractures with respect to biomechanical properties. DESIGN:Biom...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200109000-00004

    authors: Marti A,Fankhauser C,Frenk A,Cordey J,Gasser B

    更新日期:2001-09-01 00:00:00

  • A Novel Traction Frame for Femur Fracture Management in Developing Countries: Technique and Outcomes.

    abstract::Fractures of the femur have long been a major cause of morbidity and mortality in developing countries and are most frequently caused by road traffic accidents. Intramedullary nail fixation has become the gold standard of care for diaphyseal fractures of the femur. However, modern techniques require proper implants, a...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000001407

    authors: Levy DM,Meadows MC,Gates DJ

    更新日期:2019-05-01 00:00:00

  • Do Safe Radiographic Sacral Screw Pathways Exist in a Pediatric Patient Population and Do They Change With Age?

    abstract:OBJECTIVES:Iliosacral screw pathways in the first (S1) and second (S2) sacral segments are commonly used for adult pelvic ring stabilization. We hypothesize that radiographically "safe" pathways exist in pediatric patients. SETTING:Academic level I Trauma Center. PATIENTS:All patients between ages 2 and 16 years with...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章

    doi:10.1097/BOT.0000000000000421

    authors: Burn M,Gary JL,Holzman M,Heydemann JA,Munz JW,Galpin M,Ambrose CG,Achor TS,Kumaravel M

    更新日期:2016-01-01 00:00:00

  • Traumatic Separation of the Distal Ulnar Physis in Children: A New Classification for Displaced Volar-Flexion Injuries.

    abstract:OBJECTIVES:To propose a new fracture classification according to the direction of epiphysis displacement and to compare clinical findings and surgical outcomes between these subtypes. DESIGN:Retrospective study. SETTING:A tertiary referral hospital. PATIENTS:Twelve adolescents (mean age, 13.4 ± 1.3 years) who experi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000060

    authors: Cheng PG,Chang WN,Lin HS,Wu SK,Wang MN

    更新日期:2014-08-01 00:00:00

  • Regional anesthesia improves outcome after distal radius fracture fixation over general anesthesia.

    abstract:OBJECTIVE:To compare the efficacy of anesthetic type on clinical outcomes after operative treatment of distal radius fractures. DESIGN:Retrospective review of prospectively collected data. SETTING:Academic medical center. PATIENTS:One hundred eighty-seven patients with a distal radius fracture (OTA type 23) were ide...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318238becb

    authors: Egol KA,Soojian MG,Walsh M,Katz J,Rosenberg AD,Paksima N

    更新日期:2012-09-01 00:00:00

  • Valgus osteotomy of the proximal femur with sliding hip screw for the treatment of femoral neck nonunions: the technique, a case series, and literature review.

    abstract::Femoral neck nonunions are a difficult complication in the treatment of femoral neck fractures and have traditionally been managed using an intertrochanteric valgus osteotomy and blade plate. We propose an alternative method, a proximal femoral valgus osteotomy using a sliding hip screw instead of a blade plate. This ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/00005131-200608000-00006

    authors: Schoenfeld AJ,Vrabec GA

    更新日期:2006-07-01 00:00:00

  • The Community Orthopaedic Surgeon Taking Trauma Call: Lateral Humeral Condyle Fracture Pearls and Pitfalls.

    abstract::Lateral condyle fractures are second only to supracondylar humeral fractures when it comes to pediatric elbow fractures. Whether minimally displaced or substantially displaced, these growth plate fractures may present significant treatment challenges. These include nonunion, malunion, avascular necrosis, and growth di...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000001543

    authors: Ho CA,Mehlman CT

    更新日期:2019-08-01 00:00:00

  • Treatment of unstable peritrochanteric fractures in elderly patients with a compression hip screw or with the Vandeputte (VDP) endoprosthesis: a prospective randomized study.

    abstract::A prospective randomized study was set up, comparing a compression hip screw with the Vandeputte (VDP) endoprosthesis treatment for fresh, unstable peritrochanteric fractures, according to the Evans-Jensen and AO systems. Ninety patients, ages > or = 70 years, 47 of whom were treated with a compression hip screw and 4...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-199509040-00004

    authors: Stappaerts KH,Deldycke J,Broos PL,Staes FF,Rommens PM,Claes P

    更新日期:1995-01-01 00:00:00

  • Technical problems and complications in the removal of the less invasive stabilization system.

    abstract:OBJECTIVES:This study was designed to evaluate the frequency of intraoperative problems and complications involved with Less Invasive Stabilization System (LISS) plate removal. DESIGN:Retrospective study. SETTING:Single academic level I trauma center. METHODS:Medical records were reviewed for demographics, surgical ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181c29bf5

    authors: Suzuki T,Smith WR,Stahel PF,Morgan SJ,Baron AJ,Hak DJ

    更新日期:2010-06-01 00:00:00

  • Biomechanical Assessment of Locked Plating for the Fixation of Patella Fractures.

    abstract:OBJECTIVE:To analyze the mechanical stability of locked plating in comparison with tension-band wiring for the fixation of fractures of the patella. METHODS:Biomechanical tests were performed on artificial foam patella specimens comparing an angular stable plate and monocortical screws with tension-band wiring. Tests ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000309

    authors: Wurm S,Augat P,Bühren V

    更新日期:2015-09-01 00:00:00

  • The Size of Intramedullary Fixation Affects Endochondral-Mediated Angiogenesis During Fracture Repair.

    abstract:OBJECTIVES:To explore the effect of intramedullary pin size on the biology of a healing fracture, specifically endochondral angiogenesis. We hypothesized that fracture fixation with a smaller pin would permit greater interfragmentary strain resulting in increased total amount of vascular endothelial growth factor withi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001555

    authors: Yuasa M,Saito M,Blum DM,Hysong AA,Egawa S,Uppuganti S,Yoshii T,Okawa A,Schwartz HS,Moore-Lotridge SN,Nyman JS,Schoenecker JG

    更新日期:2019-10-01 00:00:00

  • Incidence of deep-vein thrombosis in patients with fractures of the lower extremity distal to the hip.

    abstract::Our purpose was to determine the incidence of deep-vein thrombosis (DVT) in patients who have had early operative fixation of fractures of the lower extremity distal to the hip. There is a high incidence of distal thrombosis in patients who have undergone early operative fixation of lower-extremity fractures. The inci...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199605000-00002

    authors: Abelseth G,Buckley RE,Pineo GE,Hull R,Rose MS

    更新日期:1996-01-01 00:00:00

  • Distribution of clindamycin in cortical bone during direct local infusion of the canine tibia.

    abstract::The distribution of clindamycin in tibial cortical bone, administered via direct local infusion with an implantable pump, is described. Clindamycin concentrations in cortical bone were measured after 3, 7, and 21 days of intraosseous infusion. The tibia were divided into four quadrants relative to the outflow infusion...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199410000-00003

    authors: Budsberg SC,Brown J

    更新日期:1994-10-01 00:00:00

  • Change over time of SF-36 functional outcomes for operatively treated unstable ankle fractures.

    abstract:OBJECTIVE:Ankle fractures are one of the most common operatively treated lower extremity fractures. Several studies indicate that patients often have residual effects after this injury. The purpose of this study is to use the SF-36 questionnaire at two times to assess patients' functional recovery and residual effects ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200201000-00007

    authors: Obremskey WT,Dirschl DR,Crowther JD,Craig WL 3rd,Driver RE,LeCroy CM

    更新日期:2002-01-01 00:00:00

  • Isolated ulnar shaft fractures treated with functional braces.

    abstract:OBJECTIVE:To report the results from functional bracing of isolated ulnar shaft fractures. DESIGN:Retrospective review. SETTING:Two university hospitals. PATIENTS:Isolated ulnar shaft fractures in 444 patients were stabilized in functional braces that permitted full range of motion of all joints. INTERVENTION:Prefa...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199808000-00009

    authors: Sarmiento A,Latta LL,Zych G,McKeever P,Zagorski JP

    更新日期:1998-08-01 00:00:00