Abstract:
:Unstable pelvic ring injuries are associated with an increased mortality rate, most commonly from severe hemorrhage. Circumferential pelvic antishock sheeting has proven effective for rapidly stabilizing the pelvic ring and has become an integral part of resuscitation protocols. Acute antishock sheet placement frequently results in patient hemodynamic stabilization and an accurate pelvic reduction. In these situations, we describe a technique of maintaining the pelvic sheet position for continued use as a reduction aid and using working portals to insert definitive percutaneous pelvic implants.
journal_name
J Orthop Traumajournal_title
Journal of orthopaedic traumaauthors
Gardner MJ,Osgood G,Molnar R,Chip Routt ML Jrdoi
10.1097/BOT.0b013e3181a87c6csubject
Has Abstractpub_date
2009-10-01 00:00:00pages
668-74issue
9eissn
0890-5339issn
1531-2291pii
00005131-200910000-00010journal_volume
23pub_type
杂志文章abstract::Although there is little doubt that arthroplasty of one form or another is appropriate treatment for many patients with a displaced femoral neck fracture, there is ongoing controversy about the relative merits of different types of arthroplasty among specific groups of patients. In particular, total hip arthroplasty i...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0b013e3181761490
更新日期:2009-07-01 00:00:00
abstract:OBJECTIVE:To report the outcomes of percutaneous autologous bone marrow injection for nonunion or delayed union of the distal tibial metaphysis in patients with prior plating. DESIGN:Consecutive case series. SETTING:Tertiary center. PATIENTS:Eleven consecutive patients (aged 24-51 years) were referred to us with a n...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31828bf077
更新日期:2013-09-01 00:00:00
abstract:OBJECTIVES:To assess whether plate bending at a hole significantly changes the biomechanical properties of a locked screw. METHODS:Coronal plane bends of 5-, 15-, or 45-degree angles were placed in 3.5-mm locking compression plates with the apex at a locking hole. An additional 45-degree angle test group was created i...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3182a73a77
更新日期:2014-04-01 00:00:00
abstract::Percutaneous iliosacral screw (IS) fixation for pelvic ring injuries with the use of an O-arm imaging system has been associated with decreased procedure time and improved accuracy of IS screw placement compared with the use of fluoroscopic guidance. Specifically, patients with sacral dysmorphism require identificatio...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001213
更新日期:2018-08-01 00:00:00
abstract:OBJECTIVE:This study tests the bone debridement efficacy and damage to cancellous bone produced by different wound irrigation methods. METHODS:Cancellous bone slices of bovine distal femurs (3 cm x 3 cm) were divided into eight test groups and scored with a saw in a latticed pattern. Four test groups were contaminated...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31802b41e2
更新日期:2006-11-01 00:00:00
abstract::Fifty-eight percent of the total infections in Italy of COVID-19 were found in northern Italy, in particular, Lombardy. From February 21, 2020, to March 23, 2020, 20 patients with a fracture and a diagnosis of COVID-19 were hospitalized. Demographic data, COVID-19 symptoms, laboratory and radiographic examinations, an...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001905
更新日期:2020-10-01 00:00:00
abstract::Tubular poly(L-lactide) membranes with a pore size of 5-15 microns and a molecular weight of 70,000 Daltons were implanted into 24 New Zealand skeletally mature rabbits to cover 10-mm mid-diaphyseal defects of the radius of the forelimb. An identical defect on the contralateral limb was not treated with the membrane a...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199604000-00006
更新日期:1996-01-01 00:00:00
abstract::Intracapsular femoral neck fractures are common in the elderly population after a simple fall. However, femoral neck fractures in the physiologically young are less common. Regardless, femoral neck fractures can be a source of significant morbidity and mortality if not treated correctly. Multiple management strategies...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000288
更新日期:2015-04-01 00:00:00
abstract:OBJECTIVES:To evaluate use of intraoperative fluoroscopy during acetabular surgery to determine fracture reduction and accurate placement of screws. DESIGN:Retrospective. SETTING:Level I trauma center. PARTICIPANTS:Thirty patients with thirty-two acetabular fractures. INTERVENTION:Patients were evaluated with fluor...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199908000-00004
更新日期:1999-08-01 00:00:00
abstract::Ankle fractures are commonly treated by orthopaedic surgeons and often require manipulative reduction. This can be painful for the patient and frequently uses 2 or more providers. Intra-articular injection of local anesthetic into the ankle joint precludes the need for conscious sedation (intravenous narcotics and ben...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000206
更新日期:2015-04-01 00:00:00
abstract:OBJECTIVES:Noncompliance with postoperative follow-up visits remains a common problem in orthopaedic trauma. The aim of this study was to identify risk factors for loss of follow-up after orthopaedic trauma. DESIGN:Retrospective review. SETTING:Urban level 1 academic trauma center. PATIENTS:A total of 307 (226 men/8...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000346
更新日期:2015-11-01 00:00:00
abstract::We reviewed 13 cases of unstable cervical spine treated by stabilization with posterior Roy-Camille plates and fusion. The patients were treated between 1985-1988. Six patients had acute traumatic episodes, three patients had posttraumatic instabilities, one patient had laminectomy for cervical spondylotic myelopathy,...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-198903010-00005
更新日期:1989-01-01 00:00:00
abstract:OBJECTIVES:External fixator pins are thought to have improved pullout strength if inserted into both cortices and if pilot holes are drilled. We tested these hypotheses and investigated effects of osteoporosis and pin location on pin pullout strength. METHODS:Self-drilling external fixator pins were inserted using 4 t...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3182511ed7
更新日期:2013-02-01 00:00:00
abstract:OBJECTIVE:To review and critically assess trends observed regarding the levels of evidence in published articles in orthopaedic traumatology literature. DATA SOURCES:The Journal of Orthopaedic Trauma, Journal of Bone and Joint Surgery-American, and Clinical Orthopaedics and Related Research. STUDY SELECTION:All artic...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000000557
更新日期:2016-07-01 00:00:00
abstract::Healing patterns were compared between transverse and 60 degrees oblique osteotomies in canine tibiae stabilized under external fixation. Under similar in vitro testing conditions (osteotomy ends in contact), the axial stiffness of the oblique osteotomy under external fixation was 45% of the paired transverse osteotom...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199109000-00016
更新日期:1991-01-01 00:00:00
abstract:OBJECTIVES:To determine whether surgeons' and patients' perceptions of outcomes after high-energy lower-extremity trauma are similar and to identify factors associated with disagreement. DESIGN:Prospective study. SETTING:Eight level 1 trauma centers. PATIENTS:Four hundred sixty-three patients treated for limb-threat...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,多中心研究
doi:10.1097/BOT.0b013e3181ab2c90
更新日期:2009-11-01 00:00:00
abstract::Displaced intra-articular fractures of the glenoid are rare and frequently result from high-energy injuries. Types IV, V, and VI fractures have in common a fracture line which extends medially into the scapular body. These fracture patterns present unique challenges for surgical approaches and reduction and fixation s...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0b013e31817d5356
更新日期:2008-08-01 00:00:00
abstract::Thirty-five patients with four-part displaced proximal humeral fractures and fracture-dislocations were retrospectively reviewed from the years 1977-1990. Thirty-three patients were available for study. All fractures were treated by open reduction and internal fixation allowing early motion. Surgical technique was as ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199312000-00002
更新日期:1993-01-01 00:00:00
abstract::This report presents a case demonstrating the nonunion of a capital femoral physeal fracture with a large metaphyseal fragment in a 10-year-old boy. To our knowledge, there is no previously reported case of this type of nonunion. The treatment of this nonunion presented a potential risk of premature physeal closure an...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181c83a3b
更新日期:2010-08-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to determine if proximity of cannulated lag screws to the articular surface of the patella combined with the tension band technique affects resistance to fracture gap opening, and if an alternative locking nut and bolt device without a tension band behaves in a biomechanically si...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31826f5985
更新日期:2012-12-01 00:00:00
abstract::Opening an abdominal window in a hip spica type of cast can be a troubling maneuver for both orthopaedic surgeon and patient. We present a simple device to create an abdominal window more easily. ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200307000-00009
更新日期:2003-07-01 00:00:00
abstract::This case report describes a Gustilo Anderson type IIIB tibia fracture associated with extensive segmental bone loss at the proximal meta-diaphyseal junction associated with a tibial plateau fracture and an avulsion of the tibial tubercle. After the tibial plateau fracture was stabilized using cannulated lag screws, t...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200209000-00010
更新日期:2002-09-01 00:00:00
abstract::Femoral neck nonunions are a difficult complication in the treatment of femoral neck fractures and have traditionally been managed using an intertrochanteric valgus osteotomy and blade plate. We propose an alternative method, a proximal femoral valgus osteotomy using a sliding hip screw instead of a blade plate. This ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/00005131-200608000-00006
更新日期:2006-07-01 00:00:00
abstract::Periprosthetic fractures after shoulder arthroplasty occur in up to 2% of patients. In patients with stable components who fail or cannot undergo nonoperative management, stable fixation is required. We present a new technique to obtain proximal fixation around the humeral component using a 4.5-mm large fragment plate...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000935
更新日期:2017-12-01 00:00:00
abstract::We present the case of an intraforaminal iliosacral screw placed percutaneously with aid of C-arm using inlet, outlet, and lateral views of the pelvis. The iliosacral screw was placed above the S1 foramen on the outlet view, into the middle of S1 via the ala on the inlet view, and below the cortical shadow of the ala ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200502000-00010
更新日期:2005-02-01 00:00:00
abstract:OBJECTIVES:To evaluate the incidence of unplanned reoperations after pelvic ring injuries and to develop a risk prediction model. DESIGN:Retrospective review. SETTING:Level I Trauma Center. PATIENTS:The medical records of 913 patients (644 male and 269 female patients; mean age, 39 years; age range, 16-89 years) wit...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001170
更新日期:2018-07-01 00:00:00
abstract::The benefits of being organized when starting one's career are countless and worth the time and effort in developing an effective and efficient practice. Established protocols, good habits, and methodical communication that include all members of the team will help create a system that keeps all components of one's pr...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3182a52344
更新日期:2013-10-01 00:00:00
abstract::An 80-year-old man sustained a T-shaped supracondylar fracture of the femur associated with distal one-third shaft comminution. Initial failure of a 95 degrees angle blade plate was followed by insertion of an intraarticular intramedullary nail stabilized with static locking-screw fixation. A second failure of the imp...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199308000-00004
更新日期:1993-01-01 00:00:00
abstract:OBJECTIVES:To develop an accurate machine learning (ML) predictive model incorporating patient, fracture, and trauma characteristics to identify individual patients at risk of an (occult) PMF. METHODS:Databases of 2 studies including patients with TSFs from 2 Level 1 trauma centers were combined for analysis. Using te...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001663
更新日期:2020-03-01 00:00:00
abstract::Bone grafts are the second most common tissue transplanted in the United States, and they are an essential treatment tool in the field of acute and reconstructive traumatic orthopaedic surgery. Available in cancellous, cortical, or bone marrow aspirate form, autogenous bone graft is regarded as the gold standard in th...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000001420
更新日期:2019-04-01 00:00:00