Percutaneous pelvic fixation using working portals in a circumferential pelvic antishock sheet.

Abstract:

:Unstable pelvic ring injuries are associated with an increased mortality rate, most commonly from severe hemorrhage. Circumferential pelvic antishock sheeting has proven effective for rapidly stabilizing the pelvic ring and has become an integral part of resuscitation protocols. Acute antishock sheet placement frequently results in patient hemodynamic stabilization and an accurate pelvic reduction. In these situations, we describe a technique of maintaining the pelvic sheet position for continued use as a reduction aid and using working portals to insert definitive percutaneous pelvic implants.

journal_name

J Orthop Trauma

authors

Gardner MJ,Osgood G,Molnar R,Chip Routt ML Jr

doi

10.1097/BOT.0b013e3181a87c6c

subject

Has Abstract

pub_date

2009-10-01 00:00:00

pages

668-74

issue

9

eissn

0890-5339

issn

1531-2291

pii

00005131-200910000-00010

journal_volume

23

pub_type

杂志文章
  • Optimal arthroplasty for femoral neck fractures: is total hip arthroplasty the answer?

    abstract::Although there is little doubt that arthroplasty of one form or another is appropriate treatment for many patients with a displaced femoral neck fracture, there is ongoing controversy about the relative merits of different types of arthroplasty among specific groups of patients. In particular, total hip arthroplasty i...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e3181761490

    authors: Schmidt AH,Leighton R,Parvizi J,Sems A,Berry DJ

    更新日期:2009-07-01 00:00:00

  • Percutaneous autologous bone marrow injection in the treatment of distal meta-diaphyseal tibial nonunions and delayed unions.

    abstract:OBJECTIVE:To report the outcomes of percutaneous autologous bone marrow injection for nonunion or delayed union of the distal tibial metaphysis in patients with prior plating. DESIGN:Consecutive case series. SETTING:Tertiary center. PATIENTS:Eleven consecutive patients (aged 24-51 years) were referred to us with a n...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31828bf077

    authors: Braly HL,O'Connor DP,Brinker MR

    更新日期:2013-09-01 00:00:00

  • Do locking screws work in plates bent at holes?

    abstract:OBJECTIVES:To assess whether plate bending at a hole significantly changes the biomechanical properties of a locked screw. METHODS:Coronal plane bends of 5-, 15-, or 45-degree angles were placed in 3.5-mm locking compression plates with the apex at a locking hole. An additional 45-degree angle test group was created i...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a73a77

    authors: Boulton CL,Kim H,Shah SB,Ryan SP,Metzger TA,Hsieh AH,O'Toole RV

    更新日期:2014-04-01 00:00:00

  • Intraoperative CT and Surgical Navigation for Iliosacral Screws: Technique for Patients With Sacral Dysmorphism.

    abstract::Percutaneous iliosacral screw (IS) fixation for pelvic ring injuries with the use of an O-arm imaging system has been associated with decreased procedure time and improved accuracy of IS screw placement compared with the use of fluoroscopic guidance. Specifically, patients with sacral dysmorphism require identificatio...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001213

    authors: Khan JM,Lara DL,Marquez-Lara A,Rosas S,Hasty E,Pilson HT

    更新日期:2018-08-01 00:00:00

  • Debridement of cancellous bone: a comparison of irrigation methods.

    abstract:OBJECTIVE:This study tests the bone debridement efficacy and damage to cancellous bone produced by different wound irrigation methods. METHODS:Cancellous bone slices of bovine distal femurs (3 cm x 3 cm) were divided into eight test groups and scored with a saw in a latticed pattern. Four test groups were contaminated...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31802b41e2

    authors: Draeger RW,Dirschl DR,Dahners LE

    更新日期:2006-11-01 00:00:00

  • Fractures in Patients With COVID-19 Infection: Early Prognosis and Management. A Case Series of 20 Patients in a Single Institution in Lombardy, Northern Italy.

    abstract::Fifty-eight percent of the total infections in Italy of COVID-19 were found in northern Italy, in particular, Lombardy. From February 21, 2020, to March 23, 2020, 20 patients with a fracture and a diagnosis of COVID-19 were hospitalized. Demographic data, COVID-19 symptoms, laboratory and radiographic examinations, an...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001905

    authors: Jannelli E,Castelli A,Ferranti Calderoni E,Annunziata S,Maccario G,Ivone A,Pasta G,Mosconi M

    更新日期:2020-10-01 00:00:00

  • Bone regeneration with resorbable polymeric membranes: treatment of diaphyseal bone defects in the rabbit radius with poly(L-lactide) membrane. A pilot study.

    abstract::Tubular poly(L-lactide) membranes with a pore size of 5-15 microns and a molecular weight of 70,000 Daltons were implanted into 24 New Zealand skeletally mature rabbits to cover 10-mm mid-diaphyseal defects of the radius of the forelimb. An identical defect on the contralateral limb was not treated with the membrane a...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199604000-00006

    authors: Meinig RP,Rahn B,Perren SM,Gogolewski S

    更新日期:1996-01-01 00:00:00

  • Plating of femoral neck fractures: when and how?

    abstract::Intracapsular femoral neck fractures are common in the elderly population after a simple fall. However, femoral neck fractures in the physiologically young are less common. Regardless, femoral neck fractures can be a source of significant morbidity and mortality if not treated correctly. Multiple management strategies...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000288

    authors: Florschutz AV,Donegan DJ,Haidukewych G,Liporace FA

    更新日期:2015-04-01 00:00:00

  • Intraoperative fluoroscopy to evaluate fracture reduction and hardware placement during acetabular surgery.

    abstract:OBJECTIVES:To evaluate use of intraoperative fluoroscopy during acetabular surgery to determine fracture reduction and accurate placement of screws. DESIGN:Retrospective. SETTING:Level I trauma center. PARTICIPANTS:Thirty patients with thirty-two acetabular fractures. INTERVENTION:Patients were evaluated with fluor...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199908000-00004

    authors: Norris BL,Hahn DH,Bosse MJ,Kellam JF,Sims SH

    更新日期:1999-08-01 00:00:00

  • Single provider reduction and splinting of displaced ankle fractures: a modification of Quigley's classic technique.

    abstract::Ankle fractures are commonly treated by orthopaedic surgeons and often require manipulative reduction. This can be painful for the patient and frequently uses 2 or more providers. Intra-articular injection of local anesthetic into the ankle joint precludes the need for conscious sedation (intravenous narcotics and ben...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000206

    authors: Alton TB,Harnden E,Hagen J,Firoozabadi R

    更新日期:2015-04-01 00:00:00

  • Loss of Follow-up in Orthopaedic Trauma: Who Is Getting Lost to Follow-up?

    abstract:OBJECTIVES:Noncompliance with postoperative follow-up visits remains a common problem in orthopaedic trauma. The aim of this study was to identify risk factors for loss of follow-up after orthopaedic trauma. DESIGN:Retrospective review. SETTING:Urban level 1 academic trauma center. PATIENTS:A total of 307 (226 men/8...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000346

    authors: Zelle BA,Buttacavoli FA,Shroff JB,Stirton JB

    更新日期:2015-11-01 00:00:00

  • Internal fixation of the unstable cervical spine using posterior Roy-Camille plates: preliminary report.

    abstract::We reviewed 13 cases of unstable cervical spine treated by stabilization with posterior Roy-Camille plates and fusion. The patients were treated between 1985-1988. Six patients had acute traumatic episodes, three patients had posttraumatic instabilities, one patient had laminectomy for cervical spondylotic myelopathy,...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-198903010-00005

    authors: Ebraheim NA,An HS,Jackson WT,Brown JA

    更新日期:1989-01-01 00:00:00

  • Predrilling does not improve the pullout strength of external fixator pins: a biomechanical study.

    abstract:OBJECTIVES:External fixator pins are thought to have improved pullout strength if inserted into both cortices and if pilot holes are drilled. We tested these hypotheses and investigated effects of osteoporosis and pin location on pin pullout strength. METHODS:Self-drilling external fixator pins were inserted using 4 t...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182511ed7

    authors: Oliphant BW,Kim H,Osgood GM,Golden RD,Hawks MA,Hsieh AH,OʼToole RV

    更新日期:2013-02-01 00:00:00

  • Levels of Evidence in Orthopaedic Trauma Literature.

    abstract:OBJECTIVE:To review and critically assess trends observed regarding the levels of evidence in published articles in orthopaedic traumatology literature. DATA SOURCES:The Journal of Orthopaedic Trauma, Journal of Bone and Joint Surgery-American, and Clinical Orthopaedics and Related Research. STUDY SELECTION:All artic...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000557

    authors: Scheschuk JP,Mostello AJ,Lombardi NJ,Maltenfort MG,Freedman KB,Tjoumakaris FP

    更新日期:2016-07-01 00:00:00

  • Healing patterns of transverse and oblique osteotomies in the canine tibia under external fixation.

    abstract::Healing patterns were compared between transverse and 60 degrees oblique osteotomies in canine tibiae stabilized under external fixation. Under similar in vitro testing conditions (osteotomy ends in contact), the axial stiffness of the oblique osteotomy under external fixation was 45% of the paired transverse osteotom...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199109000-00016

    authors: Aro HT,Wahner HT,Chao EY

    更新日期:1991-01-01 00:00:00

  • Surgeons and their patients disagree regarding cosmetic and overall outcomes after surgery for high-energy lower extremity trauma.

    abstract:OBJECTIVES:To determine whether surgeons' and patients' perceptions of outcomes after high-energy lower-extremity trauma are similar and to identify factors associated with disagreement. DESIGN:Prospective study. SETTING:Eight level 1 trauma centers. PATIENTS:Four hundred sixty-three patients treated for limb-threat...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0b013e3181ab2c90

    authors: O'Toole RV,Castillo RC,Pollak AN,MacKenzie EJ,Bosse MJ,LEAP Study Group.

    更新日期:2009-11-01 00:00:00

  • Surgical exposure and fixation of displaced type IV, V, and VI glenoid fractures.

    abstract::Displaced intra-articular fractures of the glenoid are rare and frequently result from high-energy injuries. Types IV, V, and VI fractures have in common a fracture line which extends medially into the scapular body. These fracture patterns present unique challenges for surgical approaches and reduction and fixation s...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e31817d5356

    authors: Nork SE,Barei DP,Gardner MJ,Schildhauer TA,Mayo KA,Benirschke SK

    更新日期:2008-08-01 00:00:00

  • Four-part displaced proximal humeral fractures: operative treatment using Kirschner wires and a tension band.

    abstract::Thirty-five patients with four-part displaced proximal humeral fractures and fracture-dislocations were retrospectively reviewed from the years 1977-1990. Thirty-three patients were available for study. All fractures were treated by open reduction and internal fixation allowing early motion. Surgical technique was as ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199312000-00002

    authors: Darder A,Darder A Jr,Sanchis V,Gastaldi E,Gomar F

    更新日期:1993-01-01 00:00:00

  • Nonunion of capital femoral physeal fracture with a large metaphyseal fragment.

    abstract::This report presents a case demonstrating the nonunion of a capital femoral physeal fracture with a large metaphyseal fragment in a 10-year-old boy. To our knowledge, there is no previously reported case of this type of nonunion. The treatment of this nonunion presented a potential risk of premature physeal closure an...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181c83a3b

    authors: Yukata K,Kubo T,Matsui Y,Koizumi T,Takata S,Yasui N

    更新日期:2010-08-01 00:00:00

  • Comparison of cannulated screw with tension band wiring versus compressive cannulated locking bolt and nut device (CompresSURE) in patella fractures-a cadaveric biomechanical study.

    abstract:OBJECTIVE:The purpose of this study was to determine if proximity of cannulated lag screws to the articular surface of the patella combined with the tension band technique affects resistance to fracture gap opening, and if an alternative locking nut and bolt device without a tension band behaves in a biomechanically si...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31826f5985

    authors: Domby B,Henderson E,Nayak A,Erdoğan M,Gutierrez S,Santoni BG,Sagi HC

    更新日期:2012-12-01 00:00:00

  • A new technique for creating an abdominal window in a hip spica cast.

    abstract::Opening an abdominal window in a hip spica type of cast can be a troubling maneuver for both orthopaedic surgeon and patient. We present a simple device to create an abdominal window more easily. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200307000-00009

    authors: Kiter E,Demirkan F,Kiliç BA,Erkula G

    更新日期:2003-07-01 00:00:00

  • Management of a long segmental defect at the proximal meta-diaphyseal junction of the tibia using a cylindrical titanium mesh cage.

    abstract::This case report describes a Gustilo Anderson type IIIB tibia fracture associated with extensive segmental bone loss at the proximal meta-diaphyseal junction associated with a tibial plateau fracture and an avulsion of the tibial tubercle. After the tibial plateau fracture was stabilized using cannulated lag screws, t...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200209000-00010

    authors: Ostermann PA,Haase N,Rübberdt A,Wich M,Ekkernkamp A

    更新日期:2002-09-01 00:00:00

  • Valgus osteotomy of the proximal femur with sliding hip screw for the treatment of femoral neck nonunions: the technique, a case series, and literature review.

    abstract::Femoral neck nonunions are a difficult complication in the treatment of femoral neck fractures and have traditionally been managed using an intertrochanteric valgus osteotomy and blade plate. We propose an alternative method, a proximal femoral valgus osteotomy using a sliding hip screw instead of a blade plate. This ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/00005131-200608000-00006

    authors: Schoenfeld AJ,Vrabec GA

    更新日期:2006-07-01 00:00:00

  • Surgical Fixation of Periprosthetic Humerus Fractures Using an Extension Plate: Surgical Technique and Report of 5 Cases.

    abstract::Periprosthetic fractures after shoulder arthroplasty occur in up to 2% of patients. In patients with stable components who fail or cannot undergo nonoperative management, stable fixation is required. We present a new technique to obtain proximal fixation around the humeral component using a 4.5-mm large fragment plate...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000935

    authors: Schoch B,Mehta S,Namdari S

    更新日期:2017-12-01 00:00:00

  • Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy.

    abstract::We present the case of an intraforaminal iliosacral screw placed percutaneously with aid of C-arm using inlet, outlet, and lateral views of the pelvis. The iliosacral screw was placed above the S1 foramen on the outlet view, into the middle of S1 via the ala on the inlet view, and below the cortical shadow of the ala ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200502000-00010

    authors: Sagi HC,Lindvall EM

    更新日期:2005-02-01 00:00:00

  • Predictors of Unplanned Reoperation After Operative Treatment of Pelvic Ring Injuries.

    abstract:OBJECTIVES:To evaluate the incidence of unplanned reoperations after pelvic ring injuries and to develop a risk prediction model. DESIGN:Retrospective review. SETTING:Level I Trauma Center. PATIENTS:The medical records of 913 patients (644 male and 269 female patients; mean age, 39 years; age range, 16-89 years) wit...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001170

    authors: Ochenjele G,Reid KR,Castillo RC,Schoonover CD,Montalvo RN,Manson TT,Sciadini MF,Nascone JW,Carlini AR,OʼToole RV

    更新日期:2018-07-01 00:00:00

  • Getting organized in your job.

    abstract::The benefits of being organized when starting one's career are countless and worth the time and effort in developing an effective and efficient practice. Established protocols, good habits, and methodical communication that include all members of the team will help create a system that keeps all components of one's pr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a52344

    authors: Siegel J

    更新日期:2013-10-01 00:00:00

  • Synovial metallosis resulting from intraarticular intramedullary nailing of a distal femoral nonunion.

    abstract::An 80-year-old man sustained a T-shaped supracondylar fracture of the femur associated with distal one-third shaft comminution. Initial failure of a 95 degrees angle blade plate was followed by insertion of an intraarticular intramedullary nail stabilized with static locking-screw fixation. A second failure of the imp...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199308000-00004

    authors: Johnson EE,Marroquin CE,Kossovsky N

    更新日期:1993-01-01 00:00:00

  • A Machine Learning Algorithm to Predict the Probability of (Occult) Posterior Malleolar Fractures Associated With Tibial Shaft Fractures to Guide "Malleolus First" Fixation.

    abstract:OBJECTIVES:To develop an accurate machine learning (ML) predictive model incorporating patient, fracture, and trauma characteristics to identify individual patients at risk of an (occult) PMF. METHODS:Databases of 2 studies including patients with TSFs from 2 Level 1 trauma centers were combined for analysis. Using te...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001663

    authors: Hendrickx LAM,Sobol GL,Langerhuizen DWG,Bulstra AEJ,Hreha J,Sprague S,Sirkin MS,Ring D,Kerkhoffs GMMJ,Jaarsma RL,Doornberg JN,Machine Learning Consortium.

    更新日期:2020-03-01 00:00:00

  • Autograft, Allograft, and Bone Graft Substitutes: Clinical Evidence and Indications for Use in the Setting of Orthopaedic Trauma Surgery.

    abstract::Bone grafts are the second most common tissue transplanted in the United States, and they are an essential treatment tool in the field of acute and reconstructive traumatic orthopaedic surgery. Available in cancellous, cortical, or bone marrow aspirate form, autogenous bone graft is regarded as the gold standard in th...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000001420

    authors: Baldwin P,Li DJ,Auston DA,Mir HS,Yoon RS,Koval KJ

    更新日期:2019-04-01 00:00:00