Surgeons and their patients disagree regarding cosmetic and overall outcomes after surgery for high-energy lower extremity trauma.

Abstract:

OBJECTIVES:To determine whether surgeons' and patients' perceptions of outcomes after high-energy lower-extremity trauma are similar and to identify factors associated with disagreement. DESIGN:Prospective study. SETTING:Eight level 1 trauma centers. PATIENTS:Four hundred sixty-three patients treated for limb-threatening lower extremity injuries and followed for 2 years. INTERVENTION:Information collected on patients and injuries, functional and clinical outcomes, and surgeons' and patients' assessments of satisfaction with cosmetic and overall recovery. MAIN OUTCOME MEASUREMENTS:Satisfaction ratings compared with weighted kappa statistics. RESULTS:We observed very poor agreement between surgeons' and patients' perceptions of cosmetic and overall outcomes. Surgeons and patients agreed on overall outcomes at a rate only 25% higher than expected by chance (kappa = 0.25; 95% confidence interval, 0.05-0.34). The level of disagreement was even higher for cosmetic outcomes as surgeons and patients agreed at a rate only 17% higher than expected by chance (kappa = 0.17; 95% confidence interval, 0.09-0.26). Surgeons were less likely than patients to be satisfied with overall recovery if the patient had an Injury Severity Score >17, had a complication, or failed to return to work at 1 year. Patients were less satisfied than surgeons with overall recovery when the patient was dissatisfied with the quality of medical care. Surgeons were less likely than patients to be satisfied with cosmetic recovery if the patient sustained a traumatic amputation or experienced a complication. Patients were less likely than surgeons to be satisfied with cosmetic recovery if the patient was female or was dissatisfied with his or her medical care. CONCLUSIONS:Surgeons' perceptions of patients' cosmetic and overall outcomes differed significantly from those of patients. Agreement was significantly worse for certain subgroups of patients. Further study of this discordance might improve our understanding of patient dissatisfaction and allow development of a more patient-centered care process.

journal_name

J Orthop Trauma

authors

O'Toole RV,Castillo RC,Pollak AN,MacKenzie EJ,Bosse MJ,LEAP Study Group.

doi

10.1097/BOT.0b013e3181ab2c90

subject

Has Abstract

pub_date

2009-11-01 00:00:00

pages

716-23

issue

10

eissn

0890-5339

issn

1531-2291

pii

00005131-200911000-00005

journal_volume

23

pub_type

杂志文章,多中心研究
  • Locked plates combined with minimally invasive insertion technique for the treatment of periprosthetic supracondylar femur fractures above a total knee arthroplasty.

    abstract:OBJECTIVE:New locked plate devices offer theoretical advantages for the treatment of supracondylar femur fractures associated with a total knee arthroplasty (TKA). These devices also can be inserted with relative ease by using minimally invasive techniques, provide a fixed angle construct, and improve fixation in osteo...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200603000-00005

    authors: Ricci WM,Loftus T,Cox C,Borrelli J

    更新日期:2006-03-01 00:00:00

  • Nonunion of capital femoral physeal fracture with a large metaphyseal fragment.

    abstract::This report presents a case demonstrating the nonunion of a capital femoral physeal fracture with a large metaphyseal fragment in a 10-year-old boy. To our knowledge, there is no previously reported case of this type of nonunion. The treatment of this nonunion presented a potential risk of premature physeal closure an...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181c83a3b

    authors: Yukata K,Kubo T,Matsui Y,Koizumi T,Takata S,Yasui N

    更新日期:2010-08-01 00:00:00

  • Does the Angle of the Nail Matter for Pertrochanteric Fracture Reduction? Matching Nail Angle and Native Neck-Shaft Angle.

    abstract:OBJECTIVES:To determine whether fixation of pertrochanteric hip fractures with cephalomedullary nails (CMNs) with a neck-shaft angle (NSA) less than the native NSA affects reduction and lag screw cutout. DESIGN:Retrospective comparative study. SETTING:Level I trauma center. PATIENTS/PARTICIPANTS:Patients treated wit...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001096

    authors: Parry JA,Barrett I,Schoch B,Yuan B,Cass J,Cross W

    更新日期:2018-04-01 00:00:00

  • Management of severe open ankle-foot trauma by a simple external fixation technique: an alternative during war and in resource-poor and low-technology environments.

    abstract::Severe open foot and ankle injuries are still a challenge for the orthopaedic surgeon. Their treatment is even more difficult in third world countries and in war settings where high-energy trauma with severe soft tissue damage is more frequent. Lack of equipment, poor resources and hygiene, and different cultural syst...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181d4be0f

    authors: Pedrini G,Cardi M,Landini A,Strada G

    更新日期:2011-03-01 00:00:00

  • Outcomes Following the Urgent Surgical Management of Displaced Femoral Neck Stress Fractures.

    abstract:OBJECTIVES:To review the clinical course, complication rates, and mid-term functional outcomes associated with the treatment of displaced femoral neck stress fractures (FNSFs). DESIGN:Retrospective Case Series. SETTING:Military Tertiary Referral Center. PATIENTS:Twenty-one operatively treated displaced FNSFs between...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001810

    authors: Cochran GK,Staeheli GR,Deafenbaugh BK,Kuhn KM

    更新日期:2020-11-01 00:00:00

  • Removal of a broken Synthes proximal spiral blade.

    abstract::Use of cephalomedullary nails is an option for treatment of subtrochanteric femur fractures. However, the magnitude of bending forces in this area of the femur often can lead to implant failure before union. We report on a case of hardware failure of a specific device (Synthes spiral blade) and a method for removal. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199803000-00010

    authors: Stover MD,Lin I,Bosse MJ

    更新日期:1998-03-01 00:00:00

  • A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates.

    abstract:OBJECTIVES:To examine the biomechanical behavior of 2 techniques of double-plate osteosynthesis for fractures of the adult distal humerus using conventional reconstruction plates and locking compression plates. DESIGN:Basic science study. SETTING:Experimental in vitro study. PATIENTS/PARTICIPANTS:Forty fresh-frozen ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200405000-00004

    authors: Korner J,Diederichs G,Arzdorf M,Lill H,Josten C,Schneider E,Linke B

    更新日期:2004-05-01 00:00:00

  • Percutaneous pelvic fixation using working portals in a circumferential pelvic antishock sheet.

    abstract::Unstable pelvic ring injuries are associated with an increased mortality rate, most commonly from severe hemorrhage. Circumferential pelvic antishock sheeting has proven effective for rapidly stabilizing the pelvic ring and has become an integral part of resuscitation protocols. Acute antishock sheet placement frequen...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181a87c6c

    authors: Gardner MJ,Osgood G,Molnar R,Chip Routt ML Jr

    更新日期:2009-10-01 00:00:00

  • Volar dislocation of multiple carpometacarpal joints: report of four cases.

    abstract::Four acute cases of volar carpometacarpal dislocations of the medial four metacarpals were treated in our hospital's emergency room. Our initial diagnosis after clinical examination was confirmed by routine x-rays of the hand. Closed reduction was followed by percutaneous fixation of the carpometacarpal joints with Ki...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199809000-00019

    authors: Kumar S,Arora A,Jain AK,Agarwal A

    更新日期:1998-09-01 00:00:00

  • Ulnar-styloid nonunion and partial rupture of extensor carpi ulnaris tendon: two case reports and review of the literature.

    abstract::Two unusual cases of symptomatic partial rupture of the extensor carpi ulnaris tendon associated with ulnar-styloid nonunion are described. Intraoperative findings suggested that the jagged surface of the distal ulna was the cause of flaying. In one case, debridement of the frayed extensor carpi ulnaris tendon and fix...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/00005131-200210000-00011

    authors: Kiyono Y,Nakatsuchi Y,Saitoh S

    更新日期:2002-10-01 00:00:00

  • The effects of clopidogrel (Plavix) and other oral anticoagulants on early hip fracture surgery.

    abstract:OBJECTIVE:Risk for bleeding complications during and after early hip fracture surgery for patients taking clopidogrel and other anticoagulants have not been defined. The purpose of this study is to assess the perioperative bleeding risks and clinical outcome after early hip fracture surgery performed on patients taking...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318240d70f

    authors: Collinge CA,Kelly KC,Little B,Weaver T,Schuster RD

    更新日期:2012-10-01 00:00:00

  • Use of the reamer irrigator aspirator for the treatment of a 20-year recurrent osteomyelitis of a healed femur fracture.

    abstract:SUMMARY:In the following case, a 20-year-old male was involved in a motorcycle accident where he sustained an open midshaft femur fracture treated with open reduction and internal fixation. Several weeks later, the wound became infected and the plate was removed. Over the following 20 years numerous incision and debrid...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318051532d

    authors: Bellapianta J,Gerdeman A,Sharan A,Lozman J

    更新日期:2007-05-01 00:00:00

  • Displaced intra-articular calcaneal fractures.

    abstract:BACKGROUND:Calcaneal fractures comprise 1 to 2 percent of all fractures. Approximately 75% of calcaneal fractures are intra-articular. The management of intra-articular calcaneal fractures remains controversial. Nonoperative treatment options include elevation, ice, early mobilization, and cyclic compression of the pla...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:

    authors: Bajammal S,Tornetta P 3rd,Sanders D,Bhandari M

    更新日期:2005-05-01 00:00:00

  • Regeneration of segmental diaphyseal defects in sheep tibiae using resorbable polymeric membranes: a preliminary study.

    abstract:OBJECTIVE:To investigate whether a long bone cortex of well-defined thickness can be regenerated by using an anatomically designed membranous resorbable "tube-in-tube" implant and to establish the functions of membranes in the healing of segmental diaphyseal bone defects larger than the "critical size." DESIGN:Bone he...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199903000-00006

    authors: Gugala Z,Gogolewski S

    更新日期:1999-03-01 00:00:00

  • Repair of supracondylar femur fracture and unilateral knee replacement at the same surgery.

    abstract::In patients who are candidates for a total knee arthroplasty and suffer a periarticular fracture of the femur, the arthroplasty may be performed after bony union of the fracture or immediately, in conjunction with the fracture repair. Herein we present the case of a sixty-year-old female with rheumatoid arthritis and ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199906000-00014

    authors: Patterson RH,Earll M

    更新日期:1999-06-01 00:00:00

  • Outcomes of Surgical Treatment of Periprosthetic Acetabular Fractures.

    abstract::Periprosthetic acetabular fractures sustained following acute trauma after total hip arthroplasty are rare and historically have poor outcomes. This article reviews 5 cases and the treatment algorithm used by a single orthopaedic surgeon specializing in acetabular fracture care with a co-surgeon specializing in arthro...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001400

    authors: Hickerson LE,Zbeda RM,Gadinsky NE,Wellman DS,Helfet DL

    更新日期:2019-02-01 00:00:00

  • rhBMP-2 enhances the bone healing response in a diabetic rat segmental defect model.

    abstract:OBJECTIVE:Recombinant human bone morphogenetic protein-2 (rhBMP-2) has been shown to enhance new bone formation in fracture and bone defect models in both normal and diabetic rats. Effects of rhBMP-2 in a segmental femoral defect model in diabetes mellitus (DM) BB Wistar rats have not been reported. METHODS:Collagen s...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31819f290e

    authors: Azad V,Breitbart E,Al-Zube L,Yeh S,O'Connor JP,Lin SS

    更新日期:2009-04-01 00:00:00

  • Technique for removal of intramedullary nails when there is failure of the proximal extraction device: a report of three cases.

    abstract::When attempting to remove an intramedullary nail, the extraction device can fail. This can occur due to stripping of the proximal threads or, more rarely, due to entrapped broken metal devices (impacted cap screws; broken introducers, extractors, or taps). This latter situation is particularly problematic if access to...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199702000-00012

    authors: Georgiadis GM,Heck BE,Ebraheim NA

    更新日期:1997-02-01 00:00:00

  • Initial radiographic evaluation of the spine after trauma: when, what, where, and how to image the acutely traumatized spine.

    abstract:BACKGROUND:Radiographic evaluation of the spine after an acute traumatic event is an integral part of the initial assessment of the patient. Despite this, an imaging protocol that includes detailed recommendations of the views, modalities, and techniques of radiographic work-up is lacking in the peer-reviewed literatur...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/01.bot.0000188036.69078.ef

    authors: France JC,Bono CM,Vaccaro AR

    更新日期:2005-10-01 00:00:00

  • Surgical treatment of a displaced lateral malleolus fracture: the antiglide technique versus lateral plate fixation.

    abstract:OBJECTIVES:To assess the outcomes of the surgical management of "isolated" displaced lateral malleolar fractures, comparing the techniques of lateral plating and antiglide plating as described previously. DESIGN:This is a retrospective review, being largely a surgeon-randomized comparative study. SETTING:The study wa...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200208000-00008

    authors: Lamontagne J,Blachut PA,Broekhuyse HM,O'Brien PJ,Meek RN

    更新日期:2002-08-01 00:00:00

  • Nail and Plate Combination Fixation for Periprosthetic and Interprosthetic Fractures.

    abstract::Nail plate combination technique can be applied in the setting of periprosthetic and interprosthetic fractures to promote reliable healing with a biomechanically favorable construct. Here, technical aspects and discussion of the technique are reviewed through a case of an 87-year-old woman who suffered from an interpr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001571

    authors: Yoon RS,Patel JN,Liporace FA

    更新日期:2019-09-01 00:00:00

  • Clinical Experience With the Use of Low-Intensity Pulsed Ultrasound (LIPUS) in the Treatment of Atypical Femoral Fractures.

    abstract:OBJECTIVE:The aim of this study was to report the clinical results of atypical femoral fractures (AFFs) treated with low-intensity pulsed ultrasound (LIPUS). MATERIALS AND METHODS:The data on AFFs that were surgically treated in our hospital from 2010 to 2016 was retrospectively analyzed. AFF was diagnosed based on th...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000520889.69599.f3

    authors: Lee SY,Niikura T,Iwakura T,Fukui T,Kuroda R

    更新日期:2017-07-01 00:00:00

  • Does Value Matter in Orthopaedic Trauma?: A Survey of Orthopaedic Trauma Association Members.

    abstract:OBJECTIVES:With value-based payment models on the horizon, this study was designed to examine the perceptions of value-based care among orthopaedic traumatologists and how they influence their practice. DESIGN:Systems-based survey study. SETTING:Orthopaedic Trauma Association (OTA) research surveys. PARTICIPANTS:OTA...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001622

    authors: Gorman TL,S Albersheim M,Parikh HR,Flagstad IR,Okelana AB,Vang S,Johal H,Cunningham BP

    更新日期:2019-11-01 00:00:00

  • Comparison of Outcomes of Intertrochanteric Fracture Fixation Using Percutaneous Compression Plate Between Stable and Unstable Fractures in the Elderly.

    abstract:OBJECTIVES:To evaluate the outcomes of treatment with a percutaneous compression plate (PCCP) in stable and unstable intertrochanteric hip fractures. DESIGN:Clinical prospective nonrandomized cohort study. SETTING:San Cecilio University Hospital, Granada (Spain). A tertiary-care hospital. PATIENTS:Patients older tha...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000509

    authors: Carvajal-Pedrosa C,Gómez-Sánchez RC,Hernández-Cortés P

    更新日期:2016-06-01 00:00:00

  • Biomechanical evaluation of methods of internal fixation of the distal humerus.

    abstract::The best results following fractures of the distal humerus are provided by anatomic reduction and rigid internal fixation. Plates of two designs placed in five different fixation configurations were used to determine the construct that would maximize rigidity of fixation of the distal humerus. Using a cadaver distal h...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Schemitsch EH,Tencer AF,Henley MB

    更新日期:1994-12-01 00:00:00

  • A biomechanical study of three wiring techniques for cerclage-plating.

    abstract::Transverse fractures at the distal tip of a well-fixed femoral prosthesis are difficult to stabilize using plates and screws due to the presence of the underlying intramedullary stem. The attachment of plates using cerclage wires obviates the need for screws, but the stability provided by cerclage plating is a clinica...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199505000-00004

    authors: Stevens SS,Irish AJ,Vachtsevanos JG,Csongradi J,Beaupré GS

    更新日期:1995-01-01 00:00:00

  • Infection Rates and Treatment of Low-Velocity Extremity Gunshot Injuries.

    abstract:OBJECTIVES:To determine the rates of infection in low-energy gunshot wounds (GSWs) to the extremity. DESIGN:Retrospective review. SETTING:Level I trauma center. PATIENTS/PARTICIPANTS:Patients (N = 140) with at least 90-day follow-up for extremity-only low-energy GSW injuries from 2010-2014 were retrospectively revie...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000827

    authors: Nguyen MP,Savakus JC,OʼDonnell JA,Prayson NF,Reich MS,Golob JF Jr,McDonald AA,Como JJ,Vallier HA

    更新日期:2017-06-01 00:00:00

  • A cost analysis of internal fixation versus nonoperative treatment in adult midshaft clavicle fractures using multiple randomized controlled trials.

    abstract:BACKGROUND:To determine whether the cost of nonoperative treatment, including those who require delayed operative treatment, is less than those receiving initial operative management. METHODS:We identified 4 recent randomized controlled trials comparing operative and nonoperative treatment of displaced midshaft clavic...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,meta分析,评审

    doi:10.1097/BOT.0000000000000225

    authors: Walton B,Meijer K,Melancon K,Hartman M

    更新日期:2015-04-01 00:00:00

  • A new technique for creating an abdominal window in a hip spica cast.

    abstract::Opening an abdominal window in a hip spica type of cast can be a troubling maneuver for both orthopaedic surgeon and patient. We present a simple device to create an abdominal window more easily. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200307000-00009

    authors: Kiter E,Demirkan F,Kiliç BA,Erkula G

    更新日期:2003-07-01 00:00:00

  • Efficacy of popliteal block in postoperative pain control after ankle fracture fixation: a prospective randomized study.

    abstract:OBJECTIVES:To compare postoperative pain control in patients treated surgically for ankle fractures who receive popliteal blocks with those who received general anesthesia alone. DESIGN:Institutional Review Board approved prospective randomized study. SETTING:Metropolitan tertiary-care referral center. PATIENTS:All ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/BOT.0b013e3182638b25

    authors: Goldstein RY,Montero N,Jain SK,Egol KA,Tejwani NC

    更新日期:2012-10-01 00:00:00