Percutaneous autologous bone marrow injection in the treatment of distal meta-diaphyseal tibial nonunions and delayed unions.

Abstract:

OBJECTIVE:To report the outcomes of percutaneous autologous bone marrow injection for nonunion or delayed union of the distal tibial metaphysis in patients with prior plating. DESIGN:Consecutive case series. SETTING:Tertiary center. PATIENTS:Eleven consecutive patients (aged 24-51 years) were referred to us with a nonunion or delayed union of the distal tibial metaphysis after open reduction and internal fixation (plates and screws) at the time of fracture. The average time from initial injury to nonunion or delayed union and bone marrow treatment was 8 months (range, 3-20 months). INTERVENTION:A total of 40-80 mL of bone marrow aspirated from the posterior iliac crest and injected in and around the nonunion or delayed union site under fluoroscopic guidance. MEASUREMENTS:Healing at the injury site was evaluated using clinical and radiographic criteria, including computed tomography. Measures included American Academy of Orthopaedic Surgeons Lower Limb Core Scale (LLCS), Brief Pain Inventory, and Short Form 12 Physical Component Summary. RESULTS:Nine of the 11 patients attained bony union within 6 months of bone marrow injection. Six of these 9 patients who were followed-up an average of 4.4 years (range, 1.3-8.2 years) after the injection reported significant (P < 0.05) improvements in Lower Limb Core Scale (59.9-89.7), pain intensity (2.9-1.7), pain interference (4.6-2.3), and Short Form 12 Physical Component Summary (29.5-46.6) and 5.6 years improvement in quality-adjusted life years. CONCLUSIONS:Percutaneous autologous bone marrow injection is a minimally invasive, safe, and inexpensive treatment option for distal metaphyseal tibial nonunions or delayed unions after internal fixation and should be considered when the retained hardware seems to be intact and stable. LEVEL OF EVIDENCE:Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

journal_name

J Orthop Trauma

authors

Braly HL,O'Connor DP,Brinker MR

doi

10.1097/BOT.0b013e31828bf077

subject

Has Abstract

pub_date

2013-09-01 00:00:00

pages

527-33

issue

9

eissn

0890-5339

issn

1531-2291

journal_volume

27

pub_type

杂志文章
  • Getting organized in your job.

    abstract::The benefits of being organized when starting one's career are countless and worth the time and effort in developing an effective and efficient practice. Established protocols, good habits, and methodical communication that include all members of the team will help create a system that keeps all components of one's pr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a52344

    authors: Siegel J

    更新日期:2013-10-01 00:00:00

  • Effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture.

    abstract:OBJECTIVES:Comparison of the effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture. DESIGN:Randomized, prospective. SETTING:Orthopaedic research laboratory. ANIMALS:Ten large (greater than twenty-five kilo...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199710000-00006

    authors: Jain R,Podworny N,Hearn T,Anderson GI,Schemitsch EH

    更新日期:1997-10-01 00:00:00

  • Distraction external fixation in lateral compression pelvic fractures.

    abstract:OBJECTIVE:To observe the results and describe the technique of closed reduction and placement of a two-pin supra-acetabular external fixator, followed by immediate weight bearing, in the treatment of displaced vertically stable lateral compression pelvic fractures. DESIGN:Prospective, consecutive. SETTING:Regional tr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Bellabarba C,Ricci WM,Bolhofner BR

    更新日期:2006-01-01 00:00:00

  • Arthroplasty Versus Internal Fixation for the Treatment of Undisplaced Femoral Neck Fractures: A Retrospective Cohort Study.

    abstract:OBJECTIVE:To compare the 24-month risk of mortality between arthroplasty and internal fixation for undisplaced femoral neck fractures (FNFs). DESIGN:Retrospective cohort study. SETTING:Secondary data analysis of 2 multinational randomized controlled trials. PARTICIPANTS:Patients aged 50 years or older with a FNF. I...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001940

    authors: Afaq S,OʼHara NN,Schemitsch EH,Bzovsky S,Sprague S,Poolman RW,Frihagen F,Heels-Ansdell D,Bhandari M,Swiontkowski M,Slobogean GP,FAITH Investigators.,HEALTH Investigators.

    更新日期:2020-11-01 00:00:00

  • Prospective comparison of contrast-enhanced computed tomography versus magnetic resonance venography in the detection of occult deep pelvic vein thrombosis in patients with pelvic and acetabular fractures.

    abstract:OBJECTIVE:To determine the rate of pelvic vein thrombosis following acetabular or pelvic fracture identified by enhanced computed tomography venography or magnetic resonance venography. DESIGN:Prospective evaluation of computed tomography venography and magnetic resonance venography in patients with pelvic and acetabu...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200210000-00001

    authors: Stover MD,Morgan SJ,Bosse MJ,Sims SH,Howard BJ,Stackhouse D,Weresh MJ,Kellam JF

    更新日期:2002-10-01 00:00:00

  • Modern perspectives of open reduction and plate fixation of proximal humerus fractures.

    abstract::Recent innovations have greatly increased the range of proximal humeral fractures that are amenable to open reduction and plate fixation.The optimum technique for some of the more complex fracture patterns is not yet fully refined.This article aims to describe the recent advances in the treatment of complex proximal h...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e31821c0a2f

    authors: Robinson CM,Amin AK,Godley KC,Murray IR,White TO

    更新日期:2011-10-01 00:00:00

  • Predictors of Unplanned Reoperation After Operative Treatment of Pelvic Ring Injuries.

    abstract:OBJECTIVES:To evaluate the incidence of unplanned reoperations after pelvic ring injuries and to develop a risk prediction model. DESIGN:Retrospective review. SETTING:Level I Trauma Center. PATIENTS:The medical records of 913 patients (644 male and 269 female patients; mean age, 39 years; age range, 16-89 years) wit...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001170

    authors: Ochenjele G,Reid KR,Castillo RC,Schoonover CD,Montalvo RN,Manson TT,Sciadini MF,Nascone JW,Carlini AR,OʼToole RV

    更新日期:2018-07-01 00:00:00

  • Does the Coexistence of Multiple Segmental Rib Fractures in Polytrauma Patients Presenting With "Major" Vertebral Fracture Affect Care and Acute Outcomes?

    abstract:OBJECTIVE:To determine whether operating on "major" vertebral fractures leads to premature abortion of surgery and/or other acute cardiopulmonary complications. DESIGN:Retrospective review. CLINICAL SETTING:Level 1 trauma center. PATIENTS/PARTICIPANTS AND INTERVENTION:We retrospectively queried our institutional Tra...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001316

    authors: Alvi MA,Kapurch JR 2nd,Ivanov DV,Kerezoudis P,Bydon M,Freedman BA

    更新日期:2019-01-01 00:00:00

  • In vitro femoral stiffness after femoral neck osteotomy and osteosynthesis with defined surgical errors.

    abstract::In our search for an osteosynthesis device that would tolerate the surgical errors of the inexperienced surgeon, we tested in vitro femoral stiffness in 75 human osteoporotic femora after internal fixation of a cervical neck osteotomy using three commonly used devices: two von Bahr screws (A. Ericsson AB, Sweden), two...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199608000-00009

    authors: Hernefalk L,Messner K

    更新日期:1996-01-01 00:00:00

  • Upscaling Virtual Fracture Clinic Use Is a Safe, Effective Measure in the Delivery of Trauma Care.

    abstract::The Virtual Fracture Clinic (VFC) has proved beneficial in reducing footfall within the hospital setting, improving the cost of running a trauma service, while satisfying the majority of referred patients. The mandatory upscaling of telemedicine use, specifically the enhancement of the VFC, amidst the COVID-19 pandemi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001894

    authors: Hughes AJ,Feeley IH,Crowley M,Conlon B,Merghani K,Sheehan EC

    更新日期:2020-09-01 00:00:00

  • Dual-purpose bone grafts improve healing and reduce infection.

    abstract:OBJECTIVE:To determine if a dual-purpose bone graft can regenerate bone and reduce infection in highly contaminated bone critical size defects in rats. METHODS:Biodegradable polyurethane (PUR) scaffolds were loaded with recombinant human bone morphogenetic protein-2 (BMP-2) and vancomycin (Vanc). The release kinetics ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31821f624c

    authors: Guelcher SA,Brown KV,Li B,Guda T,Lee BH,Wenke JC

    更新日期:2011-08-01 00:00:00

  • The use of a biodegradable, load-bearing scaffold as a carrier for antibiotics in an infected open fracture model.

    abstract:OBJECTIVES:Open fractures with bone loss are common, disabling injuries. Biodegradable, load-bearing scaffolds able to carry high concentrations of local antibiotics are an emerging technology to address these injuries. This study investigates the use of such scaffolds with gentamicin (along with bone morphogenetic pro...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181ed1349

    authors: Stewart RL,Cox JT,Volgas D,Stannard J,Duffy L,Waites KB,Chu TM

    更新日期:2010-09-01 00:00:00

  • Percutaneous pelvic fixation using working portals in a circumferential pelvic antishock sheet.

    abstract::Unstable pelvic ring injuries are associated with an increased mortality rate, most commonly from severe hemorrhage. Circumferential pelvic antishock sheeting has proven effective for rapidly stabilizing the pelvic ring and has become an integral part of resuscitation protocols. Acute antishock sheet placement frequen...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181a87c6c

    authors: Gardner MJ,Osgood G,Molnar R,Chip Routt ML Jr

    更新日期:2009-10-01 00:00:00

  • Comparison of Outcomes of Intertrochanteric Fracture Fixation Using Percutaneous Compression Plate Between Stable and Unstable Fractures in the Elderly.

    abstract:OBJECTIVES:To evaluate the outcomes of treatment with a percutaneous compression plate (PCCP) in stable and unstable intertrochanteric hip fractures. DESIGN:Clinical prospective nonrandomized cohort study. SETTING:San Cecilio University Hospital, Granada (Spain). A tertiary-care hospital. PATIENTS:Patients older tha...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000509

    authors: Carvajal-Pedrosa C,Gómez-Sánchez RC,Hernández-Cortés P

    更新日期:2016-06-01 00:00:00

  • Extra-articular malunions of the scapula: a comparison of functional outcome before and after reconstruction.

    abstract:OBJECTIVE:To assess surgical and functional results after corrective reconstruction of malunited, scapula neck or body fractures in patients who presented with chronic pain, limited range of motion, weakness, and gross deformity of the shoulder. DESIGN:Case series. SETTING:Level I teaching trauma center. PATIENTS:Be...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31820af67f

    authors: Cole PA,Talbot M,Schroder LK,Anavian J

    更新日期:2011-11-01 00:00:00

  • Reverse shoulder prosthesis for acute four-part fracture: tuberosity fixation using a horseshoe graft.

    abstract::Results of hemiarthroplasty for complex four-part proximal humerus fractures in the elderly have been unreliable. Although patients often achieve pain relief, return of above-shoulder level function can be challenging, because tuberosity nonunion, malunion, and/or resorption is quite common. The reverse shoulder repla...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181f22088

    authors: Levy JC,Badman B

    更新日期:2011-05-01 00:00:00

  • Short versus long cephalomedullary nails for the treatment of intertrochanteric hip fractures in patients older than 65 years.

    abstract:OBJECTIVES:To compare failure rates between short and long cephalomedullary nails used for the treatment of intertrochanteric hip fractures in patients over 65 years of age. DESIGN:Retrospective cohort study. Data were collected from medical records and radiographs. SETTING:Three level 1 trauma centers. PATIENTS/PAR...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000036

    authors: Kleweno C,Morgan J,Redshaw J,Harris M,Rodriguez E,Zurakowski D,Vrahas M,Appleton P

    更新日期:2014-07-01 00:00:00

  • A new technique for creating an abdominal window in a hip spica cast.

    abstract::Opening an abdominal window in a hip spica type of cast can be a troubling maneuver for both orthopaedic surgeon and patient. We present a simple device to create an abdominal window more easily. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200307000-00009

    authors: Kiter E,Demirkan F,Kiliç BA,Erkula G

    更新日期:2003-07-01 00:00:00

  • Surgical Fixation of Periprosthetic Humerus Fractures Using an Extension Plate: Surgical Technique and Report of 5 Cases.

    abstract::Periprosthetic fractures after shoulder arthroplasty occur in up to 2% of patients. In patients with stable components who fail or cannot undergo nonoperative management, stable fixation is required. We present a new technique to obtain proximal fixation around the humeral component using a 4.5-mm large fragment plate...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000935

    authors: Schoch B,Mehta S,Namdari S

    更新日期:2017-12-01 00:00:00

  • Stabilization of pediatric diaphyseal femur fractures with flexible intramedullary nails (a technique paper).

    abstract::The indications for surgical stabilization of a pediatric diaphyseal femur fracture are expanding. Children with multiple system injuries, a head injury, and/or multiple fractures have fewer local and distant complications if the femur fracture is treated operatively. Other indications include a pathological fracture ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199212000-00011

    authors: Heinrich SD,Drvaric D,Darr K,MacEwen GD

    更新日期:1992-01-01 00:00:00

  • Surgical treatment of a displaced lateral malleolus fracture: the antiglide technique versus lateral plate fixation.

    abstract:OBJECTIVES:To assess the outcomes of the surgical management of "isolated" displaced lateral malleolar fractures, comparing the techniques of lateral plating and antiglide plating as described previously. DESIGN:This is a retrospective review, being largely a surgeon-randomized comparative study. SETTING:The study wa...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200208000-00008

    authors: Lamontagne J,Blachut PA,Broekhuyse HM,O'Brien PJ,Meek RN

    更新日期:2002-08-01 00:00:00

  • Character, Incidence, and Predictors of Knee Pain and Activity After Infrapatellar Intramedullary Nailing of an Isolated Tibia Fracture.

    abstract:OBJECTIVE:To study the activity and incidence of knee pain after sustaining an isolated tibia fracture treated with an infrapatellar intramedullary nail at 1 year. DESIGN:Retrospective review of prospective cohort. SETTING:Multicenter Academic and Community hospitals. PATIENTS:Four hundred thirty-seven patients with...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000000475

    authors: Obremskey W,Agel J,Archer K,To P,Tornetta P 3rd,SPRINT Investigators.

    更新日期:2016-03-01 00:00:00

  • Can We Estimate the Amount of Malrotation in Supracondylar Humerus Fractures After CRPP?

    abstract:BACKGROUND:Acceptable amounts of malrotation after CRPP for pediatric supracondylar humerus fracture (SCHFx) have yet to be defined. This is an attempt to correlate radiographic parameters of a malrotated SCHFx with degrees of rotational malalignment to assist intraoperative assessment of reduction. METHODS:3D models ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001735

    authors: Prabhakar P,Pierce WA,Standefer KD,Ho CA

    更新日期:2020-07-01 00:00:00

  • Removal of a broken Synthes proximal spiral blade.

    abstract::Use of cephalomedullary nails is an option for treatment of subtrochanteric femur fractures. However, the magnitude of bending forces in this area of the femur often can lead to implant failure before union. We report on a case of hardware failure of a specific device (Synthes spiral blade) and a method for removal. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199803000-00010

    authors: Stover MD,Lin I,Bosse MJ

    更新日期:1998-03-01 00:00:00

  • Use of the reamer irrigator aspirator for the treatment of a 20-year recurrent osteomyelitis of a healed femur fracture.

    abstract:SUMMARY:In the following case, a 20-year-old male was involved in a motorcycle accident where he sustained an open midshaft femur fracture treated with open reduction and internal fixation. Several weeks later, the wound became infected and the plate was removed. Over the following 20 years numerous incision and debrid...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318051532d

    authors: Bellapianta J,Gerdeman A,Sharan A,Lozman J

    更新日期:2007-05-01 00:00:00

  • Partridge osteosynthesis: a prospective clinical study on the use of nylon cerclage bands and plates in the treatment of periprosthetic femoral shaft fractures.

    abstract:OBJECTIVE:To evaluate the clinical use of the Partridge osteosynthesis in periprosthetic femoral fractures. DESIGN AND SETTING:Prospective nonrandomized clinical study. PATIENTS:Over a ten-year period, 222 patients presenting with femoral fractures near the tip of a hip prosthesis were treated with the Partridge syst...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章

    doi:10.1097/00005131-200101000-00011

    authors: de Ridder VA,de Lange S,Koomen AR,Heatley FW

    更新日期:2001-01-01 00:00:00

  • Patellar fixation protected with a load-sharing cable: a mechanical and clinical study.

    abstract::The stability of patellar fracture fixation protected with a load-sharing cable was studied in cadavers. A transverse patellar osteotomy was produced and stabilized with standard patellar fixation with or without a figure-of-eight cable that extends from the proximal pole of the patella to the tibial tubercle. Standar...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-198802030-00010

    authors: Perry CR,McCarthy JA,Kain CC,Pearson RL

    更新日期:1988-01-01 00:00:00

  • The trochanteric C-clamp for provisional pelvic stability.

    abstract::The application of a pelvic clamp for provisional stability of unstable pelvic fractures has been advocated in the orthopaedic literature. Although the technique has gained some supporters, problems with placement and associated complications have prevented widespread acceptance. We have modified the pelvic clamp (ACE...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000175156.92743.db

    authors: Archdeacon MT,Hiratzka J

    更新日期:2006-01-01 00:00:00

  • The treatment of intertrochanteric fractures: results using an intramedullary nail with integrated cephalocervical screws and linear compression.

    abstract:OBJECTIVE:A new device for the treatment of intertrochanteric fractures that uses 2 cephalocervical screws in an integrated mechanism allowing linear intraoperative compression and rotational stability of the head/neck fragment has been developed. The aim of this study was to describe the results using this device for ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章

    doi:10.1097/BOT.0b013e31819211b2

    authors: Ruecker AH,Rupprecht M,Gruber M,Gebauer M,Barvencik F,Briem D,Rueger JM

    更新日期:2009-01-01 00:00:00

  • Economic Impact of Nonmodifiable Risk Factors in Orthopaedic Fracture Care: Is Bundled Payment Feasible?

    abstract:OBJECTIVES:To determine whether bundled payments are feasible in the orthopaedic fracture setting, and the potential economic implications of this reimbursement structure. DESIGN:Prospective. SETTING:Multicenter. PATIENTS/PARTICIPANTS:Between 2004 and 2014, a total of 23,643 operatively treated patients with fractur...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000742

    authors: Mahure SA,Hutzler L,Yoon RS,Bosco JA

    更新日期:2017-03-01 00:00:00