Surgical exposure and fixation of displaced type IV, V, and VI glenoid fractures.

Abstract:

:Displaced intra-articular fractures of the glenoid are rare and frequently result from high-energy injuries. Types IV, V, and VI fractures have in common a fracture line which extends medially into the scapular body. These fracture patterns present unique challenges for surgical approaches and reduction and fixation strategies. A modified posterior approach allows for the simultaneous exposure of the medial scapular border and the glenoid articular surface. An initial reduction of the medial fracture indirectly restores the scapular relationship, allowing for subsequent completion of the articular reduction via a limited approach to the posterior shoulder using the same incision.

journal_name

J Orthop Trauma

authors

Nork SE,Barei DP,Gardner MJ,Schildhauer TA,Mayo KA,Benirschke SK

doi

10.1097/BOT.0b013e31817d5356

subject

Has Abstract

pub_date

2008-08-01 00:00:00

pages

487-93

issue

7

eissn

0890-5339

issn

1531-2291

pii

00005131-200808000-00009

journal_volume

22

pub_type

杂志文章,评审
  • Does the Angle of the Nail Matter for Pertrochanteric Fracture Reduction? Matching Nail Angle and Native Neck-Shaft Angle.

    abstract:OBJECTIVES:To determine whether fixation of pertrochanteric hip fractures with cephalomedullary nails (CMNs) with a neck-shaft angle (NSA) less than the native NSA affects reduction and lag screw cutout. DESIGN:Retrospective comparative study. SETTING:Level I trauma center. PATIENTS/PARTICIPANTS:Patients treated wit...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001096

    authors: Parry JA,Barrett I,Schoch B,Yuan B,Cass J,Cross W

    更新日期:2018-04-01 00:00:00

  • Operative fixation of acetabular fractures in the pregnant patient.

    abstract:OBJECTIVE:To describe in utero radiation exposures in pregnant patients undergoing acetabular fracture repair. DESIGN:Retrospective case series. SETTING:University-affiliated regional trauma center. PATIENT/PARTICIPANTS:Eight pregnant patients with acetabular fractures treated over a 6-year period. There were an add...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181847a42

    authors: Porter SE,Russell GV,Qin Z,Graves ML

    更新日期:2008-09-01 00:00:00

  • The Size of Intramedullary Fixation Affects Endochondral-Mediated Angiogenesis During Fracture Repair.

    abstract:OBJECTIVES:To explore the effect of intramedullary pin size on the biology of a healing fracture, specifically endochondral angiogenesis. We hypothesized that fracture fixation with a smaller pin would permit greater interfragmentary strain resulting in increased total amount of vascular endothelial growth factor withi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001555

    authors: Yuasa M,Saito M,Blum DM,Hysong AA,Egawa S,Uppuganti S,Yoshii T,Okawa A,Schwartz HS,Moore-Lotridge SN,Nyman JS,Schoenecker JG

    更新日期:2019-10-01 00:00:00

  • Importance of Mechanoreceptors and Other Neural Structures Within the Anterior Intermeniscal Ligament in the Etiology of Anterior Knee Pain After Tibial Nailing.

    abstract:BACKGROUND:Anterior knee pain is the most common complication after intramedullary tibial nailing. The cause is often multifactorial and varies among individuals. Violation of the anterior intermeniscal ligament (AIL) during intramedullary tibial nailing might be a possible source of postsurgical anterior knee pain. Al...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001258

    authors: Franke J,Brobeil A,Lips KS,Gattenloehner S,Franke AP,Hohendorff B,Alt V,Schnettler R

    更新日期:2018-10-01 00:00:00

  • Complications of nailing in closed tibial fractures.

    abstract::Reamed intramedullary nailing was used to treat 102 closed tibial shaft fractures. Although a high rate of union was achieved (98%), we noted a higher incidence of complications than previously reported. Thirty-five (37%) patients exhibited one or more components of malunion. In 17 (18%) patients, further operative pr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199509060-00004

    authors: Williams J,Gibbons M,Trundle H,Murray D,Worlock P

    更新日期:1995-01-01 00:00:00

  • Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail.

    abstract:OBJECTIVES:To compare the results between a new intramedullary Gamma nail and a compression hip screw in the treatment of trochanteric fractures. DESIGN:Prospective randomized. SETTING:Level 1 trauma center. PATIENTS:Two hundred ten consecutive patients older than 65 years with trochanteric femoral fractures. INTER...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.bot.0000151819.95075.ad

    authors: Utrilla AL,Reig JS,Muñoz FM,Tufanisco CB

    更新日期:2005-04-01 00:00:00

  • Use of the reamer irrigator aspirator for the treatment of a 20-year recurrent osteomyelitis of a healed femur fracture.

    abstract:SUMMARY:In the following case, a 20-year-old male was involved in a motorcycle accident where he sustained an open midshaft femur fracture treated with open reduction and internal fixation. Several weeks later, the wound became infected and the plate was removed. Over the following 20 years numerous incision and debrid...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318051532d

    authors: Bellapianta J,Gerdeman A,Sharan A,Lozman J

    更新日期:2007-05-01 00:00:00

  • Biomechanical study of atlantoaxial arthrodesis: transarticular screw fixation versus modified Brooks posterior wiring.

    abstract:OBJECTIVE:The purpose of the present study was to compare the biomechanical stability of C1 and C2 vertebrae after treatment of ligamentous instability by either modified Brooks posterior wiring (MB) or transarticular screw (TAS) techniques. We hypothesized that the TAS technique would be more stable because of direct ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199909000-00004

    authors: Mitchell TC,Sadasivan KK,Ogden AL,Mayeux RH,Mukherjee DP,Albright JA

    更新日期:1999-09-01 00:00:00

  • Anteroinferior 2.7-mm versus 3.5-mm plating for AO/OTA type B clavicle fractures: a comparative cohort clinical outcomes study.

    abstract:OBJECTIVES:To compare the Disability of the Arm, Shoulder, and Hand (DASH) and Constant scores, time to union, rate of union, patient cosmetic satisfaction rate, and the need for secondary procedures between 2.7- and 3.5-mm anteroinferior plating for Arbeitsgemeinschaft für Osteosynthesefragen (AO)/Orthopaedic Trauma A...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182693f32

    authors: Galdi B,Yoon RS,Choung EW,Reilly MC,Sirkin M,Smith WR,Liporace FA

    更新日期:2013-03-01 00:00:00

  • A comparison between the effects of acetaminophen and celecoxib on bone fracture healing in rats.

    abstract:OBJECTIVES:This study compared the acute treatment effects of systemic analgesics with (celecoxib) and without anti-inflammatory activity (acetaminophen) on bone fracture healing. STUDY DESIGN:Longitudinal time study of fracture healing in rats. METHODS:Closed, mid diaphyseal femur fractures were produced in female S...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000184144.98071.5d

    authors: Bergenstock M,Min W,Simon AM,Sabatino C,O'Connor JP

    更新日期:2005-11-01 00:00:00

  • The Community Orthopaedic Surgeon Taking Trauma Call: Lateral Humeral Condyle Fracture Pearls and Pitfalls.

    abstract::Lateral condyle fractures are second only to supracondylar humeral fractures when it comes to pediatric elbow fractures. Whether minimally displaced or substantially displaced, these growth plate fractures may present significant treatment challenges. These include nonunion, malunion, avascular necrosis, and growth di...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000001543

    authors: Ho CA,Mehlman CT

    更新日期:2019-08-01 00:00:00

  • Accuracy study of computer-assisted drilling: the effect of bone density, drill bit characteristics, and use of a mechanical guide.

    abstract:OBJECTIVE:This study was designed to determine the clinical relevant accuracy of CT-based navigation for drilling. DESIGN:Experimental model. SETTING:Laboratory. METHODS:Twelve drills of varying lengths and diameters were tested with 2 different set-ups. Group 1 used free-hand navigated drilling technique with foam ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Hüfner T,Geerling J,Oldag G,Richter M,Kfuri M Jr,Pohlemann T,Krettek C

    更新日期:2005-05-01 00:00:00

  • A prospective, randomized study of intramedullary nails inserted with and without reaming for the treatment of open and closed fractures of the tibial shaft.

    abstract:OBJECTIVES:To determine if there are differences in healing, complications, or number of procedures required to obtain union among open and closed tibia fractures treated with intramedullary (IM) nails inserted with and without reaming. DESIGN:Prospective, surgeon-randomized comparative study. SETTING:Level One traum...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-200003000-00007

    authors: Finkemeier CG,Schmidt AH,Kyle RF,Templeman DC,Varecka TF

    更新日期:2000-03-01 00:00:00

  • Medial elbow exposure for coronoid fractures: FCU-split versus over-the-top.

    abstract:OBJECTIVE:The optimal exposure interval for anteromedial coronoid fractures is unknown. The purpose of this study was to quantitatively compare the osseous and ligamentous exposure of the medial elbow using the flexor carpi ulnaris (FCU)-Splitting and Hotchkiss Over-the-Top approaches. METHODS:Forty surgical approache...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31828ba91c

    authors: Huh J,Krueger CA,Medvecky MJ,Hsu JR,Skeletal Trauma Research Consortium.

    更新日期:2013-12-01 00:00:00

  • Gravity Stress Radiographs and the Effect of Ankle Position on Deltoid Ligament Integrity and Medial Clear Space Measurements.

    abstract:INTRODUCTION:External rotation and gravity stress radiographs have been described to distinguish stable supination-external rotation-II (SER-II) ankle fractures from unstable SER-IV fractures. It has been previously shown that both external rotation and gravity stress views are equivalent in their ability to diagnose d...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000817

    authors: Ashraf A,Murphree J,Wait E,Winston T,Wooldridge A,Meriwether M,Wilson J,Grimes JS

    更新日期:2017-05-01 00:00:00

  • Alleviation of Pain After Femur and Tibia Shaft Fractures Using Nothing Stronger Than Codeine and Tramadol.

    abstract:OBJECTIVE:To determine whether using nothing stronger than codeine and tramadol provides adequate pain alleviation in people recovering from fixation of a fracture of the femur or tibia shaft. DESIGN:Retrospective case series. SETTING:Level 1 trauma center in the United States. PATIENTS:All adult patients from Octob...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001683

    authors: Reich MS,Klahs KJ,Fernandez I,Nguyen MP

    更新日期:2020-02-01 00:00:00

  • Comparison of cannulated screw with tension band wiring versus compressive cannulated locking bolt and nut device (CompresSURE) in patella fractures-a cadaveric biomechanical study.

    abstract:OBJECTIVE:The purpose of this study was to determine if proximity of cannulated lag screws to the articular surface of the patella combined with the tension band technique affects resistance to fracture gap opening, and if an alternative locking nut and bolt device without a tension band behaves in a biomechanically si...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31826f5985

    authors: Domby B,Henderson E,Nayak A,Erdoğan M,Gutierrez S,Santoni BG,Sagi HC

    更新日期:2012-12-01 00:00:00

  • Natural history of anterior chest wall numbness after plating of clavicle fractures: educating patients.

    abstract:OBJECTIVES:Improved patient outcomes after plating of displaced clavicle fractures have been demonstrated by recent clinical studies. Many of these patients, however, complain of anterior chest wall numbness after this procedure; we hypothesize that numbness likely persists long term for many patients, but without effe...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000095

    authors: Christensen TJ,Horwitz DS,Kubiak EN

    更新日期:2014-11-01 00:00:00

  • Consortium of Orthopaedic Academic Traumatologists: A Model for Collaboration in Orthopaedic Surgery.

    abstract::In March 2016, North American academic leaders with an interest in and commitment to the field of global orthopaedics met in Orlando, Florida, to gauge each institution's clinical, research, and educational programs in developing countries, establish the main limitations to participating in global health efforts, and ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001288

    authors: Miclau T,MacKechnie MC,Shearer DW,COACT group.

    更新日期:2018-10-01 00:00:00

  • Modified Pauwels' intertrochanteric osteotomy in neglected femoral neck fractures in children: a report of 10 cases followed for a minimum of 5 years.

    abstract:OBJECTIVES:To evaluate the role of a modified Pauwels' intertrochanteric osteotomy (MPIO) in neglected femoral neck fractures in children. DESIGN:Prospective study with retrospective analysis. SETTING:Tertiary care Postgraduate Institute of Medical Sciences. PATIENTS:Ten children (8 males, 2 females) with an average...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31804cfdad

    authors: Magu NK,Singh R,Sharma AK,Ummat V

    更新日期:2007-04-01 00:00:00

  • Deep venous thrombosis complicating rupture of the medial head of the gastrocnemius muscle.

    abstract::Rupture of the medial head of the gastrocnemius muscle ("tennis leg") is an affliction generally associated with athletic activity. The diagnosis is made by careful history and physical examination. Although its findings are characteristic, previous reports have documented misdiagnosis of this lesion as thrombophlebit...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199406000-00016

    authors: Slawski DP

    更新日期:1994-01-01 00:00:00

  • Minimum 1-year follow-up for patients with vertical shear sacroiliac joint dislocations treated with iliosacral screws: does joint ankylosis or anatomic reduction contribute to functional outcome?

    abstract:OBJECTIVE:To prospectively analyze a homogenous group of trauma patients with pure sacroiliac (SI) joint dislocations treated with iliosacral screws (ISS), with specific attention to functional outcome and its correlation with the presence or absence of SI joint ankylosis and quality of reduction. DESIGN:Retrospective...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31816b6b4e

    authors: Mullis BH,Sagi HC

    更新日期:2008-05-01 00:00:00

  • The "Gull Sign": a harbinger of failure for internal fixation of geriatric acetabular fractures.

    abstract:OBJECTIVES:To identify factors affecting the outcomes of surgery for acetabular fracture in patients over the age of 60 years. DESIGN:Retrospective review of records and radiographs; current examination, radiographs and outcome surveys when possible. SETTING:Academic, Level 1 trauma center. PATIENTS/PARTICIPANTS:For...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200310000-00005

    authors: Anglen JO,Burd TA,Hendricks KJ,Harrison P

    更新日期:2003-10-01 00:00:00

  • Partridge osteosynthesis: a prospective clinical study on the use of nylon cerclage bands and plates in the treatment of periprosthetic femoral shaft fractures.

    abstract:OBJECTIVE:To evaluate the clinical use of the Partridge osteosynthesis in periprosthetic femoral fractures. DESIGN AND SETTING:Prospective nonrandomized clinical study. PATIENTS:Over a ten-year period, 222 patients presenting with femoral fractures near the tip of a hip prosthesis were treated with the Partridge syst...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章

    doi:10.1097/00005131-200101000-00011

    authors: de Ridder VA,de Lange S,Koomen AR,Heatley FW

    更新日期:2001-01-01 00:00:00

  • The effects of locked and unlocked neutralization plates on load bearing of fractures fixed with a lag screw.

    abstract:OBJECTIVES:Because locked plates as a neutralization device for lag screw fracture fixation have different biomechanics than that of unlocked plates, we investigated how this would affect lag screw load at the fracture site. The purpose of this study was to assess the load at a fracture site compressed with a lag screw...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31823b3dd1

    authors: Takemoto RC,Sugi MT,Kummer F,Koval KJ,Egol KA

    更新日期:2012-09-01 00:00:00

  • Split depression tibial plateau fractures: a biomechanical study.

    abstract:OBJECTIVE:To determine the biomechanical characteristics of four different fixation constructs for split depression fractures of the lateral tibial plateau (OTA classification 41B3.1). DESIGN:Laboratory investigation using a cadaveric simulated split depression tibial plateau fracture model. SETTING:Split depression ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200203000-00006

    authors: Karunakar MA,Egol KA,Peindl R,Harrow ME,Bosse MJ,Kellam JF

    更新日期:2002-03-01 00:00:00

  • Regeneration of segmental diaphyseal defects in sheep tibiae using resorbable polymeric membranes: a preliminary study.

    abstract:OBJECTIVE:To investigate whether a long bone cortex of well-defined thickness can be regenerated by using an anatomically designed membranous resorbable "tube-in-tube" implant and to establish the functions of membranes in the healing of segmental diaphyseal bone defects larger than the "critical size." DESIGN:Bone he...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199903000-00006

    authors: Gugala Z,Gogolewski S

    更新日期:1999-03-01 00:00:00

  • rhBMP-2 enhances the bone healing response in a diabetic rat segmental defect model.

    abstract:OBJECTIVE:Recombinant human bone morphogenetic protein-2 (rhBMP-2) has been shown to enhance new bone formation in fracture and bone defect models in both normal and diabetic rats. Effects of rhBMP-2 in a segmental femoral defect model in diabetes mellitus (DM) BB Wistar rats have not been reported. METHODS:Collagen s...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31819f290e

    authors: Azad V,Breitbart E,Al-Zube L,Yeh S,O'Connor JP,Lin SS

    更新日期:2009-04-01 00:00:00

  • Angular malalignment after intramedullary nailing of femoral shaft fractures.

    abstract:OBJECTIVES:To determine factors associated with angular malalignment of femoral shaft fractures treated with intramedullary nails and to determine differences in the incidence of angular malalignment based on fracture location, fracture comminution, and method of treatment (i.e., antegrade or retrograde). DESIGN:Retro...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200102000-00003

    authors: Ricci WM,Bellabarba C,Lewis R,Evanoff B,Herscovici D,Dipasquale T,Sanders R

    更新日期:2001-02-01 00:00:00

  • Intramedullary interlocked tibia nailing: a new technique (preliminary report).

    abstract::This paper presents a modified surgical technique for interlocked intramedullary stabilization of tibia fractures. An external distractor is used to achieve an indirect fracture reduction on a fluoroscopy table. This method avoids the potential traction complications associated with conventional fracture tables. The f...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Rubinstein RA Jr,Green JM,Duwelius PJ

    更新日期:1992-01-01 00:00:00