Nonoperative treatment of intermediate severity lateral compression type 1 pelvic ring injuries with minimally displaced complete sacral fracture.

Abstract:

OBJECTIVES:Controversy exists regarding optimum management of lateral compression type 1 (LC1) pelvic ring injuries (OTA type 61-B2.1), particularly in patients with complete sacral fractures. We hypothesized that nonoperative treatment would result in acceptable functional outcomes. DESIGN:Database review. SETTING:Level I trauma center. PATIENTS:We identified patients treated for LC1 fractures (n = 406) from 2007 to 2011 and analyzed a subset of LC1 injuries of "intermediate severity" characterized by complete sacral fracture with less than 1 cm initial displacement (n = 104). INTERVENTION:Fifty patients were contacted for functional outcome assessment at average follow-up of 33 months. MAIN OUTCOME MEASURES:Majeed pelvic score and physical component summary (PCS) score and mental component summary (MCS) score of 12-item Short-Form Health Survey version 2. RESULTS:Average Majeed pelvic score was 85.5, yielding 33 excellent, 9 good, 5 fair, and 3 poor outcomes. Mean PCS and MCS scores were 48.8 and 48.9, respectively (both confidence intervals include 50, the score for a healthy normative population). Patients with lower extremity injuries had a trend toward lower PCS and MCS and statistically significant lower mean Majeed scores (P = 0.01). Thirty-five of 37 patients without lower extremity injury had good or excellent categorical outcomes based on Majeed scores. No significant differences were observed regarding weight-bearing status, extent of anterior ring injury, or injury severity score. Radiographic follow-up was available for 36 of 50 patients. No fracture was displaced >1 cm. CONCLUSIONS:Acceptable functional outcomes can be expected after nonsurgical management of LC1 pelvic injuries with complete sacral fracture and less than 1 cm initial displacement. LEVEL OF EVIDENCE:Therapeutic level IV.

journal_name

J Orthop Trauma

authors

Gaski GE,Manson TT,Castillo RC,Slobogean GP,OʼToole RV

doi

10.1097/BOT.0000000000000130

subject

Has Abstract

pub_date

2014-12-01 00:00:00

pages

674-80

issue

12

eissn

0890-5339

issn

1531-2291

journal_volume

28

pub_type

杂志文章
  • Surgical Fixation of Periprosthetic Humerus Fractures Using an Extension Plate: Surgical Technique and Report of 5 Cases.

    abstract::Periprosthetic fractures after shoulder arthroplasty occur in up to 2% of patients. In patients with stable components who fail or cannot undergo nonoperative management, stable fixation is required. We present a new technique to obtain proximal fixation around the humeral component using a 4.5-mm large fragment plate...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000935

    authors: Schoch B,Mehta S,Namdari S

    更新日期:2017-12-01 00:00:00

  • Nail and Plate Combination Fixation for Periprosthetic and Interprosthetic Fractures.

    abstract::Nail plate combination technique can be applied in the setting of periprosthetic and interprosthetic fractures to promote reliable healing with a biomechanically favorable construct. Here, technical aspects and discussion of the technique are reviewed through a case of an 87-year-old woman who suffered from an interpr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001571

    authors: Yoon RS,Patel JN,Liporace FA

    更新日期:2019-09-01 00:00:00

  • Operative fixation of acetabular fractures in the pregnant patient.

    abstract:OBJECTIVE:To describe in utero radiation exposures in pregnant patients undergoing acetabular fracture repair. DESIGN:Retrospective case series. SETTING:University-affiliated regional trauma center. PATIENT/PARTICIPANTS:Eight pregnant patients with acetabular fractures treated over a 6-year period. There were an add...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181847a42

    authors: Porter SE,Russell GV,Qin Z,Graves ML

    更新日期:2008-09-01 00:00:00

  • Late-onset sternomanubrial dislocation with progressive kyphotic deformity after a thoracic burst fracture.

    abstract::Fractures and dislocations of the sternum may be associated with flexion-compression injuries of the thoracic spine. Sternal injuries most commonly occur at or near the sternomanubrial joint. We present a patient with a known thoracic spine fracture who developed a subsequent late-onset, symptomatic sternomanubrial di...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199509040-00014

    authors: Stahlman GC,Wyrsch RB,McNamara MJ

    更新日期:1995-01-01 00:00:00

  • Orthopaedic Trauma in the Developing World: Where Are the Gaps in Research and What Can Be Done?

    abstract:PURPOSE:There are an estimated 1.2 million deaths from road traffic injuries annually, disproportionately affecting patients in low-resource settings. The purpose of this scoping review is to identify knowledge gaps in global orthopaedic trauma in an effort to help prioritize future research. METHODS:Using the 6-stage...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000001293

    authors: Challa S,Wu HH,Cunningham BP,Liu M,Patel K,Shearer DW,Morshed S,Miclau T

    更新日期:2018-10-01 00:00:00

  • Varus Posteromedial Rotatory Instability of the Elbow: Injury Pattern and Surgical Experience of 27 Acute Consecutive Surgical Patients.

    abstract:OBJECTIVES:To identify associated injuries that occur in varus posteromedial rotatory instability (VPMRI) of the elbow and present their surgical management. DESIGN:Level II retrospective study. SETTING:Tertiary referral center. PATIENT/PARTICIPANTS:Twenty-seven patients with VPMRI injuries treated surgically over a...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001313

    authors: McLean J,Kempston MP,Pike JM,Goetz TJ,Daneshvar P

    更新日期:2018-12-01 00:00:00

  • Retrograde Femoral Nailing Using Percutaneous Reduction Techniques.

    abstract::Femoral shaft fractures are commonly treated with closed reduction and reamed intramedullary nailing. However, some reductions are difficult to obtain or maintain, especially in muscular or large patients. When closed methods fail to achieve reduction, percutaneous techniques are extremely useful. In addition, the use...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000890

    authors: Pettett BJ,Avery MC,Ostrum RF

    更新日期:2017-08-01 00:00:00

  • Efficacy of bone staples for fixation.

    abstract::The pull-out strength of two types of bone staples (A, Techmedica; B, Richards) was evaluated in a canine model and compared with a control of 6.5 mm cancellous bone screw (Synthes). Fifteen adult mongrel dogs were divided into three groups of five animals each. The implants were placed in the lateral femoral condyle ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-198701040-00009

    authors: Bargar WL,Sharkey NA,Paul HA,Manske DJ

    更新日期:1987-01-01 00:00:00

  • Scaphocapitate syndrome in a child associated with a distal radius and ulna fracture.

    abstract::A case is presented of scaphocapitate fracture syndrome associated with a Salter-Harris type II fracture of the distal radius and ulna occurring in an 11-year-old girl. The proximal fragment of the fractured capitate was rotated 180 degrees. The injury was treated by open reduction and internal fixation. One year afte...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199704000-00017

    authors: Mazur K,Stevanovic M,Schnall SB,Hannani K,Zionts LE

    更新日期:1997-04-01 00:00:00

  • Preinjury Narcotic Use Does Not Affect Treatment for Compartment Syndrome.

    abstract:OBJECTIVES:To determine the association of preinjury opioid use on incidence of fasciotomy after lower extremity trauma. DESIGN:Retrospective case-control study. SETTING:Level 1 trauma center. PATIENTS/PARTICIPANTS:We identified 245 consecutive patients treated with fasciotomy for compartment syndrome of the lower e...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001650

    authors: Chen SR,Abblitt WP,Knoll OM,Cooper SA,Backstrom ZK,Jahangir AA,Sethi MK

    更新日期:2020-03-01 00:00:00

  • Kirschner wire bending.

    abstract::Although Kirschner wires are useful implants in many situations, migration of the wire and irritation of the surrounding soft tissues are common complications. Seven steps are described herein, which result in a Kirschner wire that is bent 180° angle, providing a smooth anchor into bone. Use of this technique produces...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318290f818

    authors: Firoozabadi R,Kramer PA,Benirschke SK

    更新日期:2013-11-01 00:00:00

  • A Novel Traction Frame for Femur Fracture Management in Developing Countries: Technique and Outcomes.

    abstract::Fractures of the femur have long been a major cause of morbidity and mortality in developing countries and are most frequently caused by road traffic accidents. Intramedullary nail fixation has become the gold standard of care for diaphyseal fractures of the femur. However, modern techniques require proper implants, a...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000001407

    authors: Levy DM,Meadows MC,Gates DJ

    更新日期:2019-05-01 00:00:00

  • Optimal arthroplasty for femoral neck fractures: is total hip arthroplasty the answer?

    abstract::Although there is little doubt that arthroplasty of one form or another is appropriate treatment for many patients with a displaced femoral neck fracture, there is ongoing controversy about the relative merits of different types of arthroplasty among specific groups of patients. In particular, total hip arthroplasty i...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e3181761490

    authors: Schmidt AH,Leighton R,Parvizi J,Sems A,Berry DJ

    更新日期:2009-07-01 00:00:00

  • Inflammation, Bone Healing, and Anti-Inflammatory Drugs: An Update.

    abstract::Fracture healing is a unique multifaceted process requiring the presence of cells, molecular mediators, and angiogenic factors. The state of inflammation dominates the initial phase, but the ideal magnitude and duration of the process for an optimal outcome remains obscure. Biological response modifiers, such as plate...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000465

    authors: Giannoudis PV,Hak D,Sanders D,Donohoe E,Tosounidis T,Bahney C

    更新日期:2015-12-01 00:00:00

  • Induced Membrane Technique: Pearls and Pitfalls.

    abstract::The induced membrane technique for reconstruction of bone defects has proved its effectiveness and is now widely accepted. The 2 stages procedure, implying a cement spacer in the first stage and a huge bone graft in the second stage, responds to rigorous technical details involving each phase of the procedure. Prerequ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000979

    authors: Masquelet AC

    更新日期:2017-10-01 00:00:00

  • Femoral nerve palsy after pelvic fracture treated with INFIX: a case series.

    abstract:OBJECTIVE:The treatment of some pelvic injuries has evolved recently to include the use of a subcutaneous anterior pelvic fixator (INFIX). We present 8 cases of femoral nerve palsy in 6 patients after application of an INFIX to highlight this potentially devastating complication to pelvic surgeons using this technique ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000193

    authors: Hesse D,Kandmir U,Solberg B,Stroh A,Osgood G,Sems SA,Collinge CA

    更新日期:2015-03-01 00:00:00

  • Immediate internal fixation of open fractures of the diaphysis of the forearm.

    abstract::Immediate (within 24 h) open reduction and internal fixation of 103 open fractures of one or both bones of the forearm was accomplished in 69 patients between 1980 and 1989. Fifty-four of the 103 patients were reevaluated 1 to 7 years postinjury (average 2.5 years) to determine the efficacy of this treatment. Forty-fi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:

    authors: Duncan R,Geissler W,Freeland AE,Savoie FH

    更新日期:1992-01-01 00:00:00

  • Patellar fixation protected with a load-sharing cable: a mechanical and clinical study.

    abstract::The stability of patellar fracture fixation protected with a load-sharing cable was studied in cadavers. A transverse patellar osteotomy was produced and stabilized with standard patellar fixation with or without a figure-of-eight cable that extends from the proximal pole of the patella to the tibial tubercle. Standar...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-198802030-00010

    authors: Perry CR,McCarthy JA,Kain CC,Pearson RL

    更新日期:1988-01-01 00:00:00

  • Isolated ulnar shaft fractures treated with functional braces.

    abstract:OBJECTIVE:To report the results from functional bracing of isolated ulnar shaft fractures. DESIGN:Retrospective review. SETTING:Two university hospitals. PATIENTS:Isolated ulnar shaft fractures in 444 patients were stabilized in functional braces that permitted full range of motion of all joints. INTERVENTION:Prefa...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199808000-00009

    authors: Sarmiento A,Latta LL,Zych G,McKeever P,Zagorski JP

    更新日期:1998-08-01 00:00:00

  • Surgical treatment of a displaced lateral malleolus fracture: the antiglide technique versus lateral plate fixation.

    abstract:OBJECTIVES:To assess the outcomes of the surgical management of "isolated" displaced lateral malleolar fractures, comparing the techniques of lateral plating and antiglide plating as described previously. DESIGN:This is a retrospective review, being largely a surgeon-randomized comparative study. SETTING:The study wa...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200208000-00008

    authors: Lamontagne J,Blachut PA,Broekhuyse HM,O'Brien PJ,Meek RN

    更新日期:2002-08-01 00:00:00

  • CT scan assessment of the syndesmosis: a new reproducible method.

    abstract:OBJECTIVES:Anatomic reduction of the fibula with regard to the tibia is the goal when treating syndesmotic injuries. No objective method exists to describe the distal tibiofibular relationship. The primary and secondary objectives of this study was to describe and validate radiologic measurements of the syndesmosis and...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318284785a

    authors: Nault ML,Hébert-Davies J,Laflamme GY,Leduc S

    更新日期:2013-11-01 00:00:00

  • Modern perspectives of open reduction and plate fixation of proximal humerus fractures.

    abstract::Recent innovations have greatly increased the range of proximal humeral fractures that are amenable to open reduction and plate fixation.The optimum technique for some of the more complex fracture patterns is not yet fully refined.This article aims to describe the recent advances in the treatment of complex proximal h...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e31821c0a2f

    authors: Robinson CM,Amin AK,Godley KC,Murray IR,White TO

    更新日期:2011-10-01 00:00:00

  • Intramedullary nail fracture compression techniques: when and how to do it?

    abstract::Fracture compression can be achieved in many ways intraoperatively using either screws in compression plates, compression devices, or using intramedullary nails. The use of locked intramedullary nails combines the advantages of indirect fracture fixation and compression with minimal soft tissue disruption. This articl...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e31819f2779

    authors: Tejwani NC

    更新日期:2009-05-01 00:00:00

  • The effects of locked and unlocked neutralization plates on load bearing of fractures fixed with a lag screw.

    abstract:OBJECTIVES:Because locked plates as a neutralization device for lag screw fracture fixation have different biomechanics than that of unlocked plates, we investigated how this would affect lag screw load at the fracture site. The purpose of this study was to assess the load at a fracture site compressed with a lag screw...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31823b3dd1

    authors: Takemoto RC,Sugi MT,Kummer F,Koval KJ,Egol KA

    更新日期:2012-09-01 00:00:00

  • Nonoperative treatment of Bennett's fracture: a 13-year follow-up.

    abstract::We reviewed the treatment and results of 22 Bennett's fractures. Of these fractures, treated by closed reduction and plaster immobilization, 20 were available for follow-up. Eighteen patients had a subjectively satisfactory outcome, and seven had a radiographically confirmed arthrosis of the first carpometacarpal join...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199502000-00004

    authors: Oosterbos CJ,de Boer HH

    更新日期:1995-02-01 00:00:00

  • Far Cortical Locking Fixation of Distal Femur Fractures is Dominated by Shear at Clinically Relevant Bridge Spans.

    abstract:OBJECTIVES:Far cortical locking (FCL) constructs have been shown to increase axial interfragmentary displacement while limiting shear and have been specifically recommended in the treatment of distal femur fractures. However, there is no available data regarding their mechanical behavior within the range of bridge span...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001341

    authors: Habet N,Elkins J,Peindl R,Killen C,Lack WD

    更新日期:2019-02-01 00:00:00

  • Locking Screws With a Threaded Degradable Polymer Collar Reduce Construct Stiffness Over Time.

    abstract:OBJECTIVES:The stiffness of locking plates provide increased stability for early fracture healing but may limit late interfragmentary motion (IFM) necessary for secondary bone healing. An ideal plating construct would provide early rigidity and late flexibility to optimize bone healing. A novel screw plate construct ut...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001664

    authors: Schultz BJ,Amin NH,Mattison BJ,Mir HR,Shah AR,Cerynik DL

    更新日期:2020-03-01 00:00:00

  • Plate fixation of femoral nonunions over an intramedullary nail with autogenous bone grafting.

    abstract:OBJECTIVE:To describe a novel approach for the treatment of nonunions of diaphyseal femur fractures. DESIGN:Retrospective review. SETTING:University hospital. PATIENTS:Seven patients (six men, one woman, average age 42.5 years) with diaphyseal femoral fracture nonunions treated between November 2006 and November 200...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181dfbb33

    authors: Hakeos WM,Richards JE,Obremskey WT

    更新日期:2011-02-01 00:00:00

  • Postoperative Computed Tomography for Articular Fractures: A Systematic Review.

    abstract:OBJECTIVES:To determine the current published patterns of computed tomography (CT) use postoperatively in peri-articular fractures and identify those populations whereby postoperative CT changes management or results in better clinical outcomes. DATA SOURCES:Systematic review of MEDLINE and Cochrane using a combinatio...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,meta分析,多中心研究

    doi:10.1097/BOT.0000000000000660

    authors: Stott S,Balogh ZJ

    更新日期:2017-01-01 00:00:00

  • Improved intramedullary nail interlocking in osteoporotic bone.

    abstract:OBJECTIVE:Intramedullary nail locking bolts often fail to gain purchase or cut out in osteoporotic bone. The biomechanical stability of a bladelike device that lowers intraosseous stress levels by distributing the load over a greater volume of bone was compared with conventional locking bolts in osteoporotic bone. MET...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200103000-00008

    authors: Ito K,Hungerbühler R,Wahl D,Grass R

    更新日期:2001-03-01 00:00:00