Immediate internal fixation of open fractures of the diaphysis of the forearm.

Abstract:

:Immediate (within 24 h) open reduction and internal fixation of 103 open fractures of one or both bones of the forearm was accomplished in 69 patients between 1980 and 1989. Fifty-four of the 103 patients were reevaluated 1 to 7 years postinjury (average 2.5 years) to determine the efficacy of this treatment. Forty-five (90%) of the 50 patients with Grade I, II, or IIIA injuries had satisfactory results. The four patients with Grade IIIB or IIIC injuries had unacceptable results. This study demonstrates, as have previous investigations, that immediate open reduction and internal fixation of open forearm fractures provide acceptable results in Grades I, II, and selected Grade III injuries. The subdivision of Grade III fractures into A, B, and C types provides a previously unreported statistically significant difference in the results obtained in management of these injuries. The difference in results in Grade I, II, and IIIA injuries as compared to the Grade IIIB and C injuries was statistically significant (p = 0.0004). The difference in Grade IIIA injuries as compared to Grade IIIB and C injuries was also significant (p = 0.014). Immediate open reduction and internal fixation can be recommended in Grade I, II, and IIIA open forearm fractures. Although it is unclear from this report whether the results in Grade IIIB and C fractures were due to the management protocol, the severity of the initial injury, or combined factors, immediate open reduction and plate fixation yielded poor results in these injuries.

journal_name

J Orthop Trauma

authors

Duncan R,Geissler W,Freeland AE,Savoie FH

subject

Has Abstract

pub_date

1992-01-01 00:00:00

pages

25-31

issue

1

eissn

0890-5339

issn

1531-2291

journal_volume

6

pub_type

杂志文章,评审
  • Character, Incidence, and Predictors of Knee Pain and Activity After Infrapatellar Intramedullary Nailing of an Isolated Tibia Fracture.

    abstract:OBJECTIVE:To study the activity and incidence of knee pain after sustaining an isolated tibia fracture treated with an infrapatellar intramedullary nail at 1 year. DESIGN:Retrospective review of prospective cohort. SETTING:Multicenter Academic and Community hospitals. PATIENTS:Four hundred thirty-seven patients with...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000000475

    authors: Obremskey W,Agel J,Archer K,To P,Tornetta P 3rd,SPRINT Investigators.

    更新日期:2016-03-01 00:00:00

  • Pelvic emergency clamps: anatomic landmarks for a safe primary application.

    abstract::The application of the pelvic clamp as a tool for emergency stabilization of unstable pelvic ring fractures has proved to be a life-saving procedure. Using correct technique, the pelvic clamp can be applied within a few minutes after the patient's admission. To avoid severe complications (eg, pin perforation into the ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200402000-00008

    authors: Pohlemann T,Braune C,Gänsslen A,Hüfner T,Partenheimer A

    更新日期:2004-02-01 00:00:00

  • Navigated femoral nailing using noninvasive registration of the contralateral intact femur to restore anteversion. Technique and clinical use.

    abstract::The difficulty in assessing femoral rotation during intramedullary nailing is well-established. Navigation systems allow the surgeon to detect and set the version of the injured leg at the desired angle. We report the first cases of navigated femoral nailing using noninvasive registration of the contralateral uninjure...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31812f69a9

    authors: Kendoff D,Citak M,Gardner MJ,Gösling T,Krettek C,Hüfner T

    更新日期:2007-11-01 00:00:00

  • Failure of exchange reamed intramedullary nails for ununited femoral shaft fractures.

    abstract:OBJECTIVE:To determine the effectiveness of exchange reamed nails for treatment of aseptic femoral delayed unions and nonunions. DESIGN:Retrospective chart review. PATIENTS:Nineteen patients admitted to the Carolinas Medical Center Level I trauma center from 1990 to 1996 for repair of femoral shaft fracture nonunion ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200006000-00005

    authors: Weresh MJ,Hakanson R,Stover MD,Sims SH,Kellam JF,Bosse MJ

    更新日期:2000-06-01 00:00:00

  • Donor Site Morbidity After Anterior Iliac Bone Graft Harvesting.

    abstract:OBJECTIVES:The objective of this study was to evaluate donor site morbidity associated with anterior iliac crest bone graft harvesting for orthopaedic trauma reconstructions. DESIGN:Retrospective case series. SETTING:Level 1 trauma center. PATIENTS:Forty-Six consecutive patients who had undergone anterior iliac cres...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000551

    authors: Shin SR,Tornetta P 3rd

    更新日期:2016-06-01 00:00:00

  • Use of the Medoff sliding plate for subtrochanteric hip fractures.

    abstract:OBJECTIVE:To evaluate the effects of dynamization of a sliding hip screw plate on the fixation stability for several types of subtrochanteric fractures. Clinical results of treating reverse oblique fractures occasionally show medialization of the femoral shaft. DESIGN:Two types of plate dynamization were compared usin...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199704000-00007

    authors: Kummer FJ,Pearlman CA,Koval KJ,Ceder L

    更新日期:1997-04-01 00:00:00

  • Pullout strengths of self-reinforced poly-L-lactide (SR-PLLA) rods versus Kirschner wires in bovine femur.

    abstract:OBJECTIVE:To determine the relative amount of fixation of self-reinforced poly-L-lactide (SR-PLLA) rods and Kirschner wires in bovine cancellous bone by comparing their pullout strength DESIGN:An in vitro laboratory study was performed using bovine femurs. Ten two-millimeter-diameter pins of each type were inserted in...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200108000-00008

    authors: Rubel IF,Seligson D,Lai JL,Voor MJ,Wang M

    更新日期:2001-08-01 00:00:00

  • A mechanical study of gap motion in cadaveric femurs using short and long supracondylar nails.

    abstract:OBJECTIVE:To determine the relative stability achieved in unstable supracondylar femur fractures treated with long (36 cm) and short (20 cm) retrograde intramedullary nails using 1 or 2 proximal locking bolts. We hypothesized that longer nails would reduce fracture site motion compared with short nails and that 2 proxi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200407000-00004

    authors: Sears BR,Ostrum RF,Litsky AS

    更新日期:2004-07-01 00:00:00

  • The realities of relationship failure.

    abstract::Young surgeons and their spouses experience a myriad of stresses in the first few years of practice. Issues related to job search, moving to a new community, learning one's craft, time management, changes to spouse's career, child rearing, and the ever blurring line between work time and free time may all contribute t...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182641fd8

    authors: Dunbar RP Jr

    更新日期:2012-09-01 00:00:00

  • Percutaneous autologous bone marrow injection in the treatment of distal meta-diaphyseal tibial nonunions and delayed unions.

    abstract:OBJECTIVE:To report the outcomes of percutaneous autologous bone marrow injection for nonunion or delayed union of the distal tibial metaphysis in patients with prior plating. DESIGN:Consecutive case series. SETTING:Tertiary center. PATIENTS:Eleven consecutive patients (aged 24-51 years) were referred to us with a n...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31828bf077

    authors: Braly HL,O'Connor DP,Brinker MR

    更新日期:2013-09-01 00:00:00

  • Stabilization of pediatric diaphyseal femur fractures with flexible intramedullary nails (a technique paper).

    abstract::The indications for surgical stabilization of a pediatric diaphyseal femur fracture are expanding. Children with multiple system injuries, a head injury, and/or multiple fractures have fewer local and distant complications if the femur fracture is treated operatively. Other indications include a pathological fracture ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199212000-00011

    authors: Heinrich SD,Drvaric D,Darr K,MacEwen GD

    更新日期:1992-01-01 00:00:00

  • Biomechanical Assessment of Locked Plating for the Fixation of Patella Fractures.

    abstract:OBJECTIVE:To analyze the mechanical stability of locked plating in comparison with tension-band wiring for the fixation of fractures of the patella. METHODS:Biomechanical tests were performed on artificial foam patella specimens comparing an angular stable plate and monocortical screws with tension-band wiring. Tests ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000309

    authors: Wurm S,Augat P,Bühren V

    更新日期:2015-09-01 00:00:00

  • International Survey: Factors Associated With Operative Treatment of Distal Radius Fractures and Implications for the American Academy of Orthopaedic Surgeons' Appropriate Use Criteria.

    abstract:OBJECTIVES:Through an international survey, we assessed whether deciding to operatively treat an intra-articular distal radius fracture (DRF) is guided by identifiable patient and surgeon factors. In addition, we compared surgeons' treatment decisions with the American Academy of Orthopaedic Surgeons' Appropriate Use C...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/BOT.0000000000001517

    authors: Kyriakedes JC,Crijns TJ,Teunis T,Ring D,Bafus BT,Science of Variation Group.

    更新日期:2019-10-01 00:00:00

  • Displaced Radial Shaft Fracture: The Dorsal (Thompson) Approach to the Forearm.

    abstract::This video demonstrates a displaced radial shaft fracture repaired through a dorsal (Thompson) approach to the forearm. The patient is an 18-year-old man who sustained a left elbow dislocation and ipsilateral radial shaft fracture (OTA/AO: 22-B2) while playing basketball. The patient underwent a closed reduction of th...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001827

    authors: Shields CN,Egol KA

    更新日期:2020-08-01 00:00:00

  • The effect of suture pattern and tension on cutaneous blood flow as assessed by laser Doppler flowmetry in a pig model.

    abstract:OBJECTIVE:To determine the effects of various suture patterns on cutaneous blood flow (CBF) at the wound edge as increasing tension is applied through the suture. METHODS:Four different suture patterns commonly used for wound closure (simple, vertical mattress, horizontal mattress, and Allgower-Donati) were placed ind...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318169074c

    authors: Sagi HC,Papp S,Dipasquale T

    更新日期:2008-03-01 00:00:00

  • Symmetry Matching of the Medial Acetabular Surface-A Quantitative Analysis in View of Patient-Specific Implants.

    abstract:OBJECTIVE:To quantify intrapelvic surface symmetry in reference to a preshaped suprapectineal acetabular implant. METHODS:In this cross-sectional study, an anatomically preshaped acetabular fracture implant was fitted on 3D surface models of 516 pelvises from a preexisting bone database using a software tool for autom...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001373

    authors: Osterhoff G,Petersik A,Sprengel K,Pape HC

    更新日期:2019-03-01 00:00:00

  • Internal fixation of proximal humerus fractures using the screw-tension band technique.

    abstract::Many of the current techniques of internal fixation of proximal humerus fractures use tension band wires to achieve secure fixation, allowing immediate postoperative exercise of the affected limb. In addition, the use of a cancellous lag screw placed from the humeral shaft into the humeral head may have several advant...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199402000-00006

    authors: Cornell CN,Levine D,Pagnani MJ

    更新日期:1994-01-01 00:00:00

  • Avoiding rotational mismatch of locking distal tibia plates depends on proper plate position.

    abstract:OBJECTIVES:The purpose of this study was to evaluate the most appropriate positioning of anatomical locking plates on the distal tibia. METHODS:We positioned 4 types of locking plates (3 straight and 1 bayonet) at anterior, middle, and posterior positions on the medial malleolus on both lower limbs of 15 cadavers. We ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31827cd67d

    authors: Song HK,Noh JW,Lee JH,Yang KH

    更新日期:2013-07-01 00:00:00

  • Central head perforation, or "cut through," caused by the helical blade of the proximal femoral nail antirotation.

    abstract:OBJECTIVE:This study was designed to investigate the specific type and incidence of implant failure in patients with a proximal femur fracture treated with a proximal femoral nail antirotation. This device has a helical-shaped blade as a neck-head holding device, instead of the lag screw used in other intramedullary na...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31822c53c1

    authors: Frei HC,Hotz T,Cadosch D,Rudin M,Käch K

    更新日期:2012-08-01 00:00:00

  • Bone and cartilage formation in an experimental model of distraction osteogenesis.

    abstract:OBJECTIVES:(a) To develop a reliable and reproducible system for distraction osteogenesis in the rat to establish a model for future investigations of bone repair and regeneration. (b) To describe and characterize the histological events in distraction osteogenesis in the rat and to determine whether cartilage developm...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199802000-00008

    authors: Jazrawi LM,Majeska RJ,Klein ML,Kagel E,Stromberg L,Einhorn TA

    更新日期:1998-02-01 00:00:00

  • Split depression tibial plateau fractures: a biomechanical study.

    abstract:OBJECTIVE:To determine the biomechanical characteristics of four different fixation constructs for split depression fractures of the lateral tibial plateau (OTA classification 41B3.1). DESIGN:Laboratory investigation using a cadaveric simulated split depression tibial plateau fracture model. SETTING:Split depression ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200203000-00006

    authors: Karunakar MA,Egol KA,Peindl R,Harrow ME,Bosse MJ,Kellam JF

    更新日期:2002-03-01 00:00:00

  • The Clinical Utility of Additional Axillary and Velpeau Radiographs in the Evaluation of Suspected Shoulder Trauma.

    abstract:OBJECTIVES:To investigate the clinical utility of additional axillary or Velpeau views in evaluating potential shoulder trauma after a standard radiograph series of anteroposterior, Grashey, and/or trans-scapular views. DESIGN:Retrospective study. SETTING:Level I academic medical center. PATIENTS:All patients in a 1...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001760

    authors: Cruz SA,Castillo H,Chintapalli RTV,Adams OE,Morgan VK,Koh JL,Lee MJ,Shi LL

    更新日期:2020-08-01 00:00:00

  • Optimal arthroplasty for femoral neck fractures: is total hip arthroplasty the answer?

    abstract::Although there is little doubt that arthroplasty of one form or another is appropriate treatment for many patients with a displaced femoral neck fracture, there is ongoing controversy about the relative merits of different types of arthroplasty among specific groups of patients. In particular, total hip arthroplasty i...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e3181761490

    authors: Schmidt AH,Leighton R,Parvizi J,Sems A,Berry DJ

    更新日期:2009-07-01 00:00:00

  • Intracardiac malpositioning of a sternoclavicular fixation wire.

    abstract::A case of intracardiac malpositioning of a sternoclavicular Kirschner pin is reported. After an uneventful closed wire-fixation of sternoclavicular subluxation and a normal postanesthetic recovery, a 17-year-old male patient developed opacification of the right hemithorax and signs of internal bleeding. The lateral ch...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Smolle-Juettner FM,Hofer PH,Pinter H,Friehs G,Szyskowitz R

    更新日期:1992-01-01 00:00:00

  • Loss of Follow-up in Orthopaedic Trauma: Who Is Getting Lost to Follow-up?

    abstract:OBJECTIVES:Noncompliance with postoperative follow-up visits remains a common problem in orthopaedic trauma. The aim of this study was to identify risk factors for loss of follow-up after orthopaedic trauma. DESIGN:Retrospective review. SETTING:Urban level 1 academic trauma center. PATIENTS:A total of 307 (226 men/8...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000346

    authors: Zelle BA,Buttacavoli FA,Shroff JB,Stirton JB

    更新日期:2015-11-01 00:00:00

  • Predictors of reoperation following operative management of fractures of the tibial shaft.

    abstract:BACKGROUND:Accurate prediction of likelihood of reoperation in patients with tibial shaft fractures would facilitate optimal management. Previous studies were limited by small sample sizes and noncomprehensive examination of possible risk factors. OBJECTIVE:We conducted an observational study to determine which progno...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200305000-00006

    authors: Bhandari M,Tornetta P 3rd,Sprague S,Najibi S,Petrisor B,Griffith L,Guyatt GH

    更新日期:2003-05-01 00:00:00

  • Technical problems and complications in the removal of the less invasive stabilization system.

    abstract:OBJECTIVES:This study was designed to evaluate the frequency of intraoperative problems and complications involved with Less Invasive Stabilization System (LISS) plate removal. DESIGN:Retrospective study. SETTING:Single academic level I trauma center. METHODS:Medical records were reviewed for demographics, surgical ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181c29bf5

    authors: Suzuki T,Smith WR,Stahel PF,Morgan SJ,Baron AJ,Hak DJ

    更新日期:2010-06-01 00:00:00

  • Computed tomographic scanning of cervical spine fractures: does it influence treatment?

    abstract:OBJECTIVE:To determine whether the superior sensitivity of computed tomography (CT) results in changes in treatment plans for cervical spine fractures that have been diagnosed on plain films alone. DESIGN:Retrospective review of radiographic studies for cervical spine trauma. SETTING/PARTICIPANTS:An orthopaedic spine...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199906000-00003

    authors: Katz MA,Beredjiklian PK,Vresilovic EJ,Tahernia AD,Gabriel JP,Chan PS,Heppenstall RB

    更新日期:1999-06-01 00:00:00

  • Histomorphometry of distraction osteogenesis during experimental tibial lengthening.

    abstract:OBJECTIVES:The aim of the current study was to analyze distraction osteogenesis histomorphometrically to investigate the amount of enchondral ossification adjacent to intramembranous ossification. STUDY DESIGN:Species-specific, longitudinal time study. METHODS Lengthening of 25% of the right tibia was performed in 24 ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200302000-00006

    authors: Fink B,Pollnau C,Vogel M,Skripitz R,Enderle A

    更新日期:2003-02-01 00:00:00

  • Evidence gaps in the global decade of road traffic safety.

    abstract::Road traffic accidents are a leading cause of global mortality. In March 2010, the United Nations General Assembly and the World Health Organization (WHO) officially proclaimed 2011-2020 as the "Decade of Action for Road Safety." Researchers must focus on vulnerable road users and low- and middle-income countries (LMI...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000103

    authors: Evaniew N,Godin K,Schemitsch EH,Bhandari M

    更新日期:2014-01-01 00:00:00