Abstract:
:The application of the pelvic clamp as a tool for emergency stabilization of unstable pelvic ring fractures has proved to be a life-saving procedure. Using correct technique, the pelvic clamp can be applied within a few minutes after the patient's admission. To avoid severe complications (eg, pin perforation into the pelvis) during the application, anatomic landmarks for the correct pin placement have to be defined. The surface landmarks that are presently recommended for the correct pin placement are not always reliably found due to deformation of the body surface caused by swelling and hematoma. Our experience with 43 emergency applications of the pelvic C-clamp showed that reliable anatomic landmarks on the bony surface of the innominate bone could be identified to ensure correct pin placement. The ideal insertion point of the pins is an anatomic region on the lateral cortex of the ileum, where an easily palpable "groove" is formed by angulations of the lateral cortex of the iliac wing. Being increasingly used as an entry point for percutaneous transiliosacral screw fixations of sacroiliac joint injuries and sacral fractures, this region, which is close to the sacroiliac joint, represents an ideal point for maximum compression of the posterior pelvic ring. With the described technique, this "groove" can be identified easily even in emergency situations by blunt palpation with an instrument, avoiding the time-consuming use of a fluoroscope in most cases.
journal_name
J Orthop Traumajournal_title
Journal of orthopaedic traumaauthors
Pohlemann T,Braune C,Gänsslen A,Hüfner T,Partenheimer Adoi
10.1097/00005131-200402000-00008subject
Has Abstractpub_date
2004-02-01 00:00:00pages
102-5issue
2eissn
0890-5339issn
1531-2291pii
00005131-200402000-00008journal_volume
18pub_type
杂志文章abstract:OBJECTIVE:The open reduction and internal fixation of radial shaft fractures and osteotomies with standard 3.5-mm plates can be complicated by tendon irritation, hardware prominence, and fracture through the screw holes. With the advent of locking plate technology, implant companies and some surgeons have recommended e...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181f8bf9b
更新日期:2011-06-01 00:00:00
abstract:OBJECTIVE:To evaluate and compare the mechanical stability of two different fixation techniques on experimentally induced calcaneus fractures. METHODS:Thirteen fresh frozen cadaver lower limbs had intraarticular calcaneal fractures produced with an impact loading device. Internal fixation was then performed through la...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199708000-00010
更新日期:1997-08-01 00:00:00
abstract:BACKGROUND:Anterior knee pain is the most common complication after intramedullary tibial nailing. The cause is often multifactorial and varies among individuals. Violation of the anterior intermeniscal ligament (AIL) during intramedullary tibial nailing might be a possible source of postsurgical anterior knee pain. Al...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001258
更新日期:2018-10-01 00:00:00
abstract:OBJECTIVES:The purposes of this study were to evaluate the cantilevered bending strength and failure modes of locking screws inserted at various angles in a plate with fully circumferential threaded holes. As an additional measure, the amount of screw head prominence at these angles was also assessed. METHODS:Standard...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000066
更新日期:2014-01-01 00:00:00
abstract::A high percentage of patients with grade IIIC open tibial fractures eventually undergo amputation. Maintaining an adequate residual limb length is advantageous with regard to biomechanics, energy expenditure, and prosthetic fitting. This case report presents new considerations for maintaining residual limb length in t...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199408000-00014
更新日期:1994-08-01 00:00:00
abstract::Posterior wall (PW) fractures are the most common fractures requiring surgical fixation in acetabular surgery. Extra-articular screw placement must be confirmed intraoperatively. Herein we describe the use of the inlet and obturator oblique view (the Leeds view) for screw placement in elementary PW and in associated b...
journal_title:Journal of orthopaedic trauma
pub_type: 临床试验,杂志文章
doi:10.1097/BOT.0000000000000724
更新日期:2017-04-01 00:00:00
abstract:OBJECTIVE:The purpose of this prospective cohort study was to determine if a new patella fracture fixation construct resulted in improved outcomes compared with traditional tension band techniques. DESIGN:Comparative cohort study. SETTING:Academic level I trauma center. PATIENTS/PARTICIPANTS:Patients with isolated, ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000787
更新日期:2017-05-01 00:00:00
abstract:OBJECTIVES:To highlight the potential for vascular injury with fracture of the distal radius. DESIGN:Retrospective case series. SETTING:The practices of several orthopaedic hand surgeons. PATIENTS/PARTICIPANTS:Six patients with arterial injury as a consequence of fracture of the distal radius: 2 partial lacerations ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318188d686
更新日期:2008-10-01 00:00:00
abstract::Nail plate combination technique can be applied in the setting of periprosthetic and interprosthetic fractures to promote reliable healing with a biomechanically favorable construct. Here, technical aspects and discussion of the technique are reviewed through a case of an 87-year-old woman who suffered from an interpr...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001571
更新日期:2019-09-01 00:00:00
abstract::In our search for an osteosynthesis device that would tolerate the surgical errors of the inexperienced surgeon, we tested in vitro femoral stiffness in 75 human osteoporotic femora after internal fixation of a cervical neck osteotomy using three commonly used devices: two von Bahr screws (A. Ericsson AB, Sweden), two...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199608000-00009
更新日期:1996-01-01 00:00:00
abstract:OBJECTIVE:To determine the prognostic reliability, sensitivity, and specificity of the Hawkins sign. The Hawkins sign is a subchondral radiolucent band in the talar dome that is indicative of viability at 6 to 8 weeks after a talus fracture. It is visible in the anterior-posterior view, but seldom appears on lateral ra...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318148c665
更新日期:2007-09-01 00:00:00
abstract::Stress fracture of the anterior tibial cortex is an extremely challenging fracture to treat, especially in the high-performance female athlete who requires rapid return to competition. Previous reports have not addressed treating these fractures in the world-class athlete with anterior plating. We hypothesize that ant...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200607000-00011
更新日期:2006-07-01 00:00:00
abstract::Since the original description of osteitis deformans, the treatment of femoral fractures occurring in this disease process has been difficult. A retrospective study of 35 fractures treated over an 8-year period was undertaken to identify the factors that influenced the results. The fractures were classified according ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-198912000-00011
更新日期:1989-01-01 00:00:00
abstract:OBJECTIVES:Fractures of the distal femur are severe injuries that present many clinical challenges. Nonunion, delayed union, implant failure, and the need for secondary procedures can reflect complications of healing. This article reviews the literature on distal femur fractures treated with locking plates to determine...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0b013e3182070127
更新日期:2011-02-01 00:00:00
abstract:OBJECTIVES:Retrospective evaluation of the long-term outcomes after surgical treatment of traumatic patellar dislocations in adolescents and identification of possible predictive factors of poor outcomes. DESIGN:Retrospective clinical study. SETTING:University Clinic, Level I Trauma Center. PATIENTS:All 33 adolescen...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318299cb50
更新日期:2014-03-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to determine the extent to which the Mangled Extremity Severity Score (MESS) predicted outcomes for soldiers sustaining combat-related Gustilo-Anderson type III open tibia fractures. DESIGN:Retrospective cohort study. SETTING:Tertiary trauma center. PATIENTS:Service Members w...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000054
更新日期:2014-09-01 00:00:00
abstract:OBJECTIVE:The treatment of some pelvic injuries has evolved recently to include the use of a subcutaneous anterior pelvic fixator (INFIX). We present 8 cases of femoral nerve palsy in 6 patients after application of an INFIX to highlight this potentially devastating complication to pelvic surgeons using this technique ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000193
更新日期:2015-03-01 00:00:00
abstract::With the increase in demand for total hip and knee arthroplasty, the orthopaedic community has seen a dramatic increase in periprosthetic fractures. Given the high morbidity and mortality associated with these fractures, the orthopaedic surgeon needs to be prepared to deal with this difficult problem. The purpose of t...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31821b8c3b
更新日期:2011-06-01 00:00:00
abstract:OBJECTIVES:To describe the technique and to determine the outcome of operatively treated displaced scapular body or glenoid neck fractures using minifragment fixation through a modified Judet approach. DESIGN:Retrospective review of scapular or glenoid fractures. SETTING:Level 1 teaching trauma center. PATIENTS:All ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181a18216
更新日期:2009-09-01 00:00:00
abstract::We present a case of 39-year-old female with a scapulothoracic dissociation and acromioclavicular (AC) separation and who had fixation of the AC joint with a locking plate, coracoclavicular screw, and transarticular AC screw. The coracoclavicular and AC relationships were maintained during postoperative rehabilitation...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181831352
更新日期:2008-09-01 00:00:00
abstract::The conventional qualitative techniques of manual manipulation and plain radiography do not give a quantifiable measurement of healing. With internal fixation, manual manipulation is not usually possible, and conventional radiographs may not give much useful information, particularly if only a small amount of callus i...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199611000-00010
更新日期:1996-01-01 00:00:00
abstract:OBJECTIVES:To propose a new fracture classification according to the direction of epiphysis displacement and to compare clinical findings and surgical outcomes between these subtypes. DESIGN:Retrospective study. SETTING:A tertiary referral hospital. PATIENTS:Twelve adolescents (mean age, 13.4 ± 1.3 years) who experi...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000060
更新日期:2014-08-01 00:00:00
abstract:OBJECTIVES:The aim of this article is to provide a concise review of the basic science of extracorporeal shock wave therapy (ESWT) and to perform a systematic review of the literature for the use of ESWT in the treatment of fractures and delayed unions/nonunions. DATA SOURCES:Articles in the English or German language...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,meta分析,评审
doi:10.1097/BOT.0b013e3181cad510
更新日期:2010-03-01 00:00:00
abstract:BACKGROUND:Because embalming has been demonstrated to decrease the mechanical integrity of bone, most investigators favor fresh-frozen specimens for biomechanical evaluation. However, little is known about how the integrity of fresh--frozen specimens may change during biomechanical testing or may be affected by standar...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318225b875
更新日期:2011-08-01 00:00:00
abstract::Periprosthetic fractures after shoulder arthroplasty occur in up to 2% of patients. In patients with stable components who fail or cannot undergo nonoperative management, stable fixation is required. We present a new technique to obtain proximal fixation around the humeral component using a 4.5-mm large fragment plate...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000935
更新日期:2017-12-01 00:00:00
abstract:OBJECTIVE:This study was conducted to categorize barefoot stubbing injuries to the great toe in children by injury mechanism to differentiate benign stubbing injuries from more complex injuries necessitating surgery. DESIGN:Prospective clinical series of consecutively treated patients. SETTING:Tertiary university hos...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31828e5d39
更新日期:2013-11-01 00:00:00
abstract:OBJECTIVE:To report our experience with computed tomography (CT) scans to detect traumatic arthrotomies of the knee (TAK) joint based on the presence of intra-articular air. DESIGN:Retrospective review. SETTING:Level I trauma center. PATIENTS:Sixty-two consecutive patients (63 knees) underwent a CT scan of the knee ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31828219bc
更新日期:2013-09-01 00:00:00
abstract::Business intelligence in the field of medicine, particularly with physicians, has been an abstract concept at best with no objective metric. Furthermore, in many arenas, it was taboo for medical students, residents, and physicians to discuss the business and finances of their work for fear that it would interfere with...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000177
更新日期:2014-09-01 00:00:00
abstract:OBJECTIVE:To determine whether the practice of overlapping surgery influenced patient safety after open reduction internal fixation (ORIF) for ankle fractures. DESIGN:Retrospective case-control. SETTING:Level 1 Academic Midwest trauma center. PATIENTS:All patients who underwent ankle fracture ORIF by a single surgeo...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001757
更新日期:2020-08-01 00:00:00
abstract:OBJECTIVES:To assess the treatment preferences of orthopaedic surgeons for displaced three- and four-part proximal humerus fractures. DESIGN:Cross-sectional survey. SETTING:Academic and nonacademic institutions across Canada. PATIENTS/PARTICIPANTS:Members of the Canadian Orthopedic Trauma Society and the Joint Ortho...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181bdc46a
更新日期:2010-04-01 00:00:00