Abstract:
:Posterior wall (PW) fractures are the most common fractures requiring surgical fixation in acetabular surgery. Extra-articular screw placement must be confirmed intraoperatively. Herein we describe the use of the inlet and obturator oblique view (the Leeds view) for screw placement in elementary PW and in associated both-column with PW fractures. We highlight our steps to ensure accurate placement in a small series of patients.
journal_name
J Orthop Traumajournal_title
Journal of orthopaedic traumaauthors
Tosounidis TH,Giannoudis PVdoi
10.1097/BOT.0000000000000724subject
Has Abstractpub_date
2017-04-01 00:00:00pages
e133-e136issue
4eissn
0890-5339issn
1531-2291journal_volume
31pub_type
临床试验,杂志文章abstract:OBJECTIVES:Biomechanical studies of osteoporotic bone have used synthetic models rather than cadaveric samples because of decreased variability, increased availability, and overall ease of the use of synthetic models. We compared the torsional mechanical properties of cadaveric osteoporotic bone with those of currently...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000782
更新日期:2017-05-01 00:00:00
abstract::Forty-three patients with 43 comminuted femoral shaft fractures treated with the Brooker-Wills interlocking nail were followed through bony union to determine the device's ability to maintain length and rotational control of these difficult injuries. Only severely comminuted fractures, types III and IV, were included....
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-198702010-00002
更新日期:1987-01-01 00:00:00
abstract:BACKGROUND:Because embalming has been demonstrated to decrease the mechanical integrity of bone, most investigators favor fresh-frozen specimens for biomechanical evaluation. However, little is known about how the integrity of fresh--frozen specimens may change during biomechanical testing or may be affected by standar...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318225b875
更新日期:2011-08-01 00:00:00
abstract::Although there is little doubt that arthroplasty of one form or another is appropriate treatment for many patients with a displaced femoral neck fracture, there is ongoing controversy about the relative merits of different types of arthroplasty among specific groups of patients. In particular, total hip arthroplasty i...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0b013e3181761490
更新日期:2009-07-01 00:00:00
abstract:OBJECTIVE:To review our series of open calcaneal fractures compared with other series. DESIGN:Retrospective review. SETTING:All patients were treated at a single Level 1 trauma center. PATIENTS/PARTICIPANTS:We reviewed 19 consecutive patients, each with an open fracture of the calcaneus. Fracture morphology ranged f...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200401000-00002
更新日期:2004-01-01 00:00:00
abstract:OBJECTIVES:We developed a protocol to determine the timing of definitive fracture care based on the adequacy of resuscitation. Inception of this project required a multidisciplinary group, including physicians from anesthesiology, general trauma and critical care, neurosurgery, orthopaedic spine, and orthopaedic trauma...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000383
更新日期:2015-11-01 00:00:00
abstract:OBJECTIVE:To evaluate the outcome of patients with posterolateral tibial plateau fractures after open reduction and internal fixation with a fibula osteotomy-free posterolateral approach. DESIGN:Retrospective chart and operation note review. SETTING:A medical college-affiliated tertiary hospital. MATERIALS AND METHO...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000047
更新日期:2014-09-01 00:00:00
abstract:OBJECTIVES:To report the complications and pitfalls in the treatment of complex injuries of the proximal tibia when locking plates are used. DESIGN, SETTING, AND PATIENTS:This was a retrospective case series conducted at a university Level I trauma center. Thirty-seven patients with complex proximal tibia fractures (4...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318030df96
更新日期:2007-02-01 00:00:00
abstract::This technique article presents a small-incision, gluteal-splitting approach for the treatment of select fractures involving the posterior acetabulum. The approach essentially involves the proximal portion of the Kocher-Langenbeck incision, and it can be extended to a larger exposure if needed. It is ideally suited fo...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/01.bot.0000211143.70424.f7
更新日期:2006-09-01 00:00:00
abstract:OBJECTIVES:Comparison of the effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture. DESIGN:Randomized, prospective. SETTING:Orthopaedic research laboratory. ANIMALS:Ten large (greater than twenty-five kilo...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199710000-00006
更新日期:1997-10-01 00:00:00
abstract:BACKGROUND:Radiographic evaluation of the spine after an acute traumatic event is an integral part of the initial assessment of the patient. Despite this, an imaging protocol that includes detailed recommendations of the views, modalities, and techniques of radiographic work-up is lacking in the peer-reviewed literatur...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/01.bot.0000188036.69078.ef
更新日期:2005-10-01 00:00:00
abstract::In an attempt to reduce pin loosening, a flanged external fixator pin has been designed and its bending stiffness has been compared with that of a standard pin. The pins were inserted into pilot holes previously drilled into a piece of teak hardwood. Loads of different magnitudes were applied at a fixed moment arm and...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199502000-00013
更新日期:1995-02-01 00:00:00
abstract:PURPOSE:There are an estimated 1.2 million deaths from road traffic injuries annually, disproportionately affecting patients in low-resource settings. The purpose of this scoping review is to identify knowledge gaps in global orthopaedic trauma in an effort to help prioritize future research. METHODS:Using the 6-stage...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000001293
更新日期:2018-10-01 00:00:00
abstract::Although the benefit of spinal canal decompression of traumatic thoracolumbar burst fractures is controversial, it remains a desirable procedure, as many reports describe improved neurologic outcome with spinal canal reconstruction. The optimal type of posterior instrumentation for reconstructing the spinal canal is u...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199112000-00004
更新日期:1991-01-01 00:00:00
abstract:OBJECTIVES:Fellowship-trained orthopaedic traumatologists are presumably taught skill sets leading to "best practice" outcomes and more efficient use of hospital resources. This should result in more favorable economic opportunities when compared with general orthopaedic surgeons (GOSs) providing similar clinical servi...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3182a59d6b
更新日期:2014-05-01 00:00:00
abstract:OBJECTIVE:To compare the 24-month risk of mortality between arthroplasty and internal fixation for undisplaced femoral neck fractures (FNFs). DESIGN:Retrospective cohort study. SETTING:Secondary data analysis of 2 multinational randomized controlled trials. PARTICIPANTS:Patients aged 50 years or older with a FNF. I...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001940
更新日期:2020-11-01 00:00:00
abstract::A mechanically improved design of bone plate and screw was compared in vivo with conventional plate fixation. This method was investigated biologically in a standardized osteotomy model on sheep tibiae. It was found that maintenance of reduction of an osteotomy was facilitated and there was no adverse effect of this f...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199109000-00006
更新日期:1991-01-01 00:00:00
abstract::Fractures of the femur have long been a major cause of morbidity and mortality in developing countries and are most frequently caused by road traffic accidents. Intramedullary nail fixation has become the gold standard of care for diaphyseal fractures of the femur. However, modern techniques require proper implants, a...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,多中心研究
doi:10.1097/BOT.0000000000001407
更新日期:2019-05-01 00:00:00
abstract::Acute compartment syndrome of the deltoid is rare with only 6 cases reported in the literature. To our knowledge, there are no reported cases of deltoid compartment syndrome after surgery on the shoulder. In this case, the patient developed a tense painful anterior deltoid 3 hours after antegrade nailing of a segmenta...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318199e83c
更新日期:2009-03-01 00:00:00
abstract:OBJECTIVES:To assess the recovery of ankle function and general health status at multiple time points during the first 24 months after an isolated tibial plafond fracture treated with joint-spanning external fixation and to determine factors that affect a rapid versus a slow recovery and factors that influence patient ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181c8ad52
更新日期:2010-08-01 00:00:00
abstract:OBJECTIVE:The purpose of this prospective cohort study was to determine if a new patella fracture fixation construct resulted in improved outcomes compared with traditional tension band techniques. DESIGN:Comparative cohort study. SETTING:Academic level I trauma center. PATIENTS/PARTICIPANTS:Patients with isolated, ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000787
更新日期:2017-05-01 00:00:00
abstract:OBJECTIVES:To determine whether opioid use disorders (OUDs) are associated with adverse perioperative outcomes in patients undergoing surgical fixation for proximal femur fractures. METHODS:The National Hospital Discharge Survey was queried to identify patients surgically treated for proximal femur fractures between 1...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001118
更新日期:2018-05-01 00:00:00
abstract:BACKGROUND:Hip fractures are associated with significant morbidity and mortality. Co-management models pairing orthopaedic surgeons with hospitalists or geriatricians may be effective at improving processes of care and outcomes such as length of stay (LOS) and cost. We set out to determine the effect of an integrated h...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000691
更新日期:2016-12-01 00:00:00
abstract::Healthcare policy has changed drastically, and with the 50-year anniversary of the passage of Medicare approaching in 2015, the authors evaluate the development of the current healthcare system and its relationship to the development of modern orthopaedic trauma. With more changes in healthcare policy forthcoming, it ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000214
更新日期:2014-10-01 00:00:00
abstract:OBJECTIVE:To study the effect of tourniquet control on intramedullary reaming. DESIGN:An experimental prospective nonsurvival animal study was performed using 5 mongrel dogs. A pneumatic tourniquet was randomized to either the right or left hind limb. Tibial intramedullary reaming was performed with progressively larg...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200411000-00004
更新日期:2004-11-01 00:00:00
abstract::Tubular poly(L-lactide) membranes with a pore size of 5-15 microns and a molecular weight of 70,000 Daltons were implanted into 24 New Zealand skeletally mature rabbits to cover 10-mm mid-diaphyseal defects of the radius of the forelimb. An identical defect on the contralateral limb was not treated with the membrane a...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199604000-00006
更新日期:1996-01-01 00:00:00
abstract:OBJECTIVES:We studied the safety of immediate weight bearing as tolerated (IWBAT) and immediate range of motion (IROM) following open reduction internal fixation (ORIF) of selected malleolar ankle fractures (defined as involving bony or ligamentous disruption of two or more of the malleoli or syndesmosis without articu...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000002003
更新日期:2020-11-09 00:00:00
abstract:OBJECTIVES:The increasing number of fractures of the proximal humerus, especially in the elderly, carries with it the unsolved problem of the optimal treatment for the displaced or unstable fractures. The authors' goal was to analyze whether fixation with a bent valgus angled blade plate could improve the outcomes repo...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200604000-00004
更新日期:2006-04-01 00:00:00
abstract:OBJECTIVES:To evaluate the relationship between mechanism of injury and mortality in geriatric trauma patients and the ability of existing injury severity indices (ISIs) to assess mortality. DESIGN:Retrospective review. SETTING:Urban level 1 trauma center. PARTICIPANTS:Four thousand five hundred forty-five trauma pa...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000281
更新日期:2015-07-01 00:00:00
abstract:OBJECTIVE:The treatment of some pelvic injuries has evolved recently to include the use of a subcutaneous anterior pelvic fixator (INFIX). We present 8 cases of femoral nerve palsy in 6 patients after application of an INFIX to highlight this potentially devastating complication to pelvic surgeons using this technique ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000193
更新日期:2015-03-01 00:00:00