Predictors of reoperation following operative management of fractures of the tibial shaft.

Abstract:

BACKGROUND:Accurate prediction of likelihood of reoperation in patients with tibial shaft fractures would facilitate optimal management. Previous studies were limited by small sample sizes and noncomprehensive examination of possible risk factors. OBJECTIVE:We conducted an observational study to determine which prognostic factors were associated with an increased risk of reoperation following operative treatment in a heterogeneous population of patients with tibial shaft fractures. DESIGN:Retrospective observational study. SETTING:Level 1 trauma center. METHODS:We identified 200 patients with tibial shaft fractures from two university-affiliated centers. Two reviewers independently abstracted data regarding 20 possible prognostic variables, reviewed preoperative and postoperative radiographs, and documented reoperations (defined as any surgical procedure

journal_name

J Orthop Trauma

authors

Bhandari M,Tornetta P 3rd,Sprague S,Najibi S,Petrisor B,Griffith L,Guyatt GH

doi

10.1097/00005131-200305000-00006

subject

Has Abstract

pub_date

2003-05-01 00:00:00

pages

353-61

issue

5

eissn

0890-5339

issn

1531-2291

journal_volume

17

pub_type

杂志文章
  • Triangular osteosynthesis of vertically unstable sacrum fractures: a new concept allowing early weight-bearing.

    abstract:OBJECTIVE:Presentation of a new triangular osteosynthesis technique that permits early weight-bearing in vertically unstable sacral fractures. DESIGN:Retrospective evaluation of a consecutive series. SETTING:Level I trauma center. PATIENTS:Thirty-four patients, twenty-eight of whom were polytraumatized, all with ver...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199806000-00002

    authors: Schildhauer TA,Josten C,Muhr G

    更新日期:1998-06-01 00:00:00

  • Surgeons and their patients disagree regarding cosmetic and overall outcomes after surgery for high-energy lower extremity trauma.

    abstract:OBJECTIVES:To determine whether surgeons' and patients' perceptions of outcomes after high-energy lower-extremity trauma are similar and to identify factors associated with disagreement. DESIGN:Prospective study. SETTING:Eight level 1 trauma centers. PATIENTS:Four hundred sixty-three patients treated for limb-threat...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0b013e3181ab2c90

    authors: O'Toole RV,Castillo RC,Pollak AN,MacKenzie EJ,Bosse MJ,LEAP Study Group.

    更新日期:2009-11-01 00:00:00

  • Complex volar distal radioulnar joint dislocation occurring in a Galeazzi fracture.

    abstract::The Galeazzi fracture-dislocation of the forearm consists of a transverse or short oblique fracture of the radius at the junction of the middle and distal thirds with an associated subluxation or dislocation of the distal radioulnar joint. Anatomic reduction with rigid internal fixation of the radius typically produce...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-198903010-00015

    authors: Giangarra CE,Chandler RW

    更新日期:1989-01-01 00:00:00

  • Barefoot stubbing injuries to the great toe in children: a new classification by injury mechanism.

    abstract:OBJECTIVE:This study was conducted to categorize barefoot stubbing injuries to the great toe in children by injury mechanism to differentiate benign stubbing injuries from more complex injuries necessitating surgery. DESIGN:Prospective clinical series of consecutively treated patients. SETTING:Tertiary university hos...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31828e5d39

    authors: Park DY,Han KJ,Han SH,Cho JH

    更新日期:2013-11-01 00:00:00

  • Arthroplasty Versus Internal Fixation for the Treatment of Undisplaced Femoral Neck Fractures: A Retrospective Cohort Study.

    abstract:OBJECTIVE:To compare the 24-month risk of mortality between arthroplasty and internal fixation for undisplaced femoral neck fractures (FNFs). DESIGN:Retrospective cohort study. SETTING:Secondary data analysis of 2 multinational randomized controlled trials. PARTICIPANTS:Patients aged 50 years or older with a FNF. I...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001940

    authors: Afaq S,OʼHara NN,Schemitsch EH,Bzovsky S,Sprague S,Poolman RW,Frihagen F,Heels-Ansdell D,Bhandari M,Swiontkowski M,Slobogean GP,FAITH Investigators.,HEALTH Investigators.

    更新日期:2020-11-01 00:00:00

  • Incision placement for intramedullary tibial nailing: an anatomic study.

    abstract:OBJECTIVES:For intramedullary nailing of tibial shaft fractures, a recent study has determined that the entry site should be just medial to the lateral tibial spine at the anterior margin of the articular surface. Gaining access to this site is often through a medial parapatellar or transpatellar approach. Several stud...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200211000-00001

    authors: Althausen PL,Neiman R,Finkemeier CG,Olson SA

    更新日期:2002-11-01 00:00:00

  • Evidence gaps in the global decade of road traffic safety.

    abstract::Road traffic accidents are a leading cause of global mortality. In March 2010, the United Nations General Assembly and the World Health Organization (WHO) officially proclaimed 2011-2020 as the "Decade of Action for Road Safety." Researchers must focus on vulnerable road users and low- and middle-income countries (LMI...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000103

    authors: Evaniew N,Godin K,Schemitsch EH,Bhandari M

    更新日期:2014-01-01 00:00:00

  • The protective effect of locking screw placement on nonlocking screw extraction torque in an osteoporotic supracondylar femur fracture model.

    abstract:OBJECTIVE:To examine the impact of number and position of locking screws in the diaphyseal portion of an osteoporotic distal femoral fracture model with hybrid fixation. METHODS:Four groups containing 5 osteoporotic bone models were used with varying combinations of diaphyseal screw fixation: 4 nonlocking screws (cont...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318238c086

    authors: Dalstrom DJ,Nelles DB,Patel V,Goswami T,Markert RJ,Prayson MJ

    更新日期:2012-09-01 00:00:00

  • Fluoroscopic Views for a More Accurate Placement of Iliosacral Screws: An Experimental Study.

    abstract:OBJECTIVES:Misperception on the fluoroscopic image showing a well-placed iliosacral (IS) screw can occur, when the screw is in reality misplaced. The purpose of this study was to demonstrate and highlight examples of misperception and suggest alternative inlet and outlet views to confirm adequate IS screw placement. M...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000426

    authors: Kim JW,Quispe JC,Hao J,Herbert B,Hake M,Mauffrey C

    更新日期:2016-01-01 00:00:00

  • Open Reduction Internal Fixation of a Bimalleolar Ankle Fracture With Syndesmotic Injury.

    abstract::Rotational ankle fractures are incredibly common, resulting in a wide spectrum of bony and ligamentous injury patterns. After open reduction of an ankle fracture, the treating surgeon must always evaluate syndesmotic stability. If the syndesmosis is determined to be unstable, a reduction of the distal tibiofibular joi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000588

    authors: Ostrum RF,Avery MC

    更新日期:2016-08-01 00:00:00

  • Intraoperative CT and Surgical Navigation for Iliosacral Screws: Technique for Patients With Sacral Dysmorphism.

    abstract::Percutaneous iliosacral screw (IS) fixation for pelvic ring injuries with the use of an O-arm imaging system has been associated with decreased procedure time and improved accuracy of IS screw placement compared with the use of fluoroscopic guidance. Specifically, patients with sacral dysmorphism require identificatio...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001213

    authors: Khan JM,Lara DL,Marquez-Lara A,Rosas S,Hasty E,Pilson HT

    更新日期:2018-08-01 00:00:00

  • Dual-purpose bone grafts improve healing and reduce infection.

    abstract:OBJECTIVE:To determine if a dual-purpose bone graft can regenerate bone and reduce infection in highly contaminated bone critical size defects in rats. METHODS:Biodegradable polyurethane (PUR) scaffolds were loaded with recombinant human bone morphogenetic protein-2 (BMP-2) and vancomycin (Vanc). The release kinetics ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31821f624c

    authors: Guelcher SA,Brown KV,Li B,Guda T,Lee BH,Wenke JC

    更新日期:2011-08-01 00:00:00

  • The surgical treatment of isolated mason type 2 fractures of the radial head in adults: comparison between radial head resection and open reduction and internal fixation.

    abstract:OBJECTIVES:To compare the outcomes of two different surgical treatments for the management of isolated closed Mason Type 2 radial head fractures. DESIGN:Retrospective study. The Student t test and McPearson chi-square test were used to evaluate whether there was a significance difference between the groups. PATIENTS:...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318220a227

    authors: Zarattini G,Galli S,Marchese M,Mascio LD,Pazzaglia UE

    更新日期:2012-04-01 00:00:00

  • Mechanical failure after locking plate fixation of unstable intertrochanteric femur fractures.

    abstract:OBJECTIVES:The aim of this study was analyze modes of mechanical failure in a consecutive cohort of patients and establish possible risk factors. DESIGN:This was a retrospective cohort study. SETTING:The study was conducted at an academic level-1 trauma center. PATIENTS:Twenty-nine patients (mean age 56 years, range...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318251930d

    authors: Streubel PN,Moustoukas MJ,Obremskey WT

    更新日期:2013-01-01 00:00:00

  • Split fractures of the lateral tibial plateau: evaluation of three fixation methods.

    abstract::A laboratory study was performed to compare the stability and ultimate strength of three standard fixation techniques for split-type lateral tibial plateau fractures. The three methods of fixation were (a) three 6.5-mm cancellous lag screws with washers; (b) two 6.5-mm cancellous lag screws with washers and an additio...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199607000-00003

    authors: Koval KJ,Polatsch D,Kummer FJ,Cheng D,Zuckerman JD

    更新日期:1996-01-01 00:00:00

  • Pathomorphologic characteristics of posttraumatic acetabular dysplasia.

    abstract:OBJECTIVES:The pathomorphology of posttraumatic acetabular dysplasia differs fundamentally from the classic developmental dysplasia of the adolescent. The aim of this report is to qualify and quantify the pathomorphologic characteristics of the posttraumatic acetabular dysplasia and to define the requirements for adequ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200009000-00004

    authors: Dora C,Zurbach J,Hersche O,Ganz R

    更新日期:2000-09-01 00:00:00

  • Functional outcome after isolated acetabular fractures.

    abstract:OBJECTIVE:To evaluate objectively the effectiveness of current surgical management of displaced acetabular fractures. To provide insight into how these evaluation methods can be used to identify areas in which improvements in surgery and rehabilitation can be pursued to improve patient outcomes. DESIGN:Consecutive cas...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200202000-00001

    authors: Borrelli J Jr,Goldfarb C,Ricci W,Wagner JM,Engsberg JR

    更新日期:2002-02-01 00:00:00

  • Oblique screws at the plate ends increase the fixation strength in synthetic bone test medium.

    abstract:OBJECTIVE:To test the hypothesis that oblique screws at the ends of a plate provide increased strength of fixation as compared to standard screw insertion. DESIGN:Biomechanical laboratory study in synthetic bone test medium. METHODS:Narrow 4.5-mm stainless steel low-contoured dynamic compression plates were anchored ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200410000-00006

    authors: Stoffel K,Stachowiak G,Forster T,Gächter A,Kuster M

    更新日期:2004-10-01 00:00:00

  • The use of a biodegradable, load-bearing scaffold as a carrier for antibiotics in an infected open fracture model.

    abstract:OBJECTIVES:Open fractures with bone loss are common, disabling injuries. Biodegradable, load-bearing scaffolds able to carry high concentrations of local antibiotics are an emerging technology to address these injuries. This study investigates the use of such scaffolds with gentamicin (along with bone morphogenetic pro...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181ed1349

    authors: Stewart RL,Cox JT,Volgas D,Stannard J,Duffy L,Waites KB,Chu TM

    更新日期:2010-09-01 00:00:00

  • Ultrasound-Guided Nerve Blocks as Analgesia for Nonoperative Management of Distal Radius Fractures-Two Consecutive Randomized Controlled Trials.

    abstract:OBJECTIVES:To investigate whether a conventional fracture hematoma block (FHB) or an ultrasound-guided peripheral nerve block has more superior analgesic effect during nonoperative management of distal radius fractures in an emergency department setting. Two peripheral nerve block types were investigated, one at the le...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/BOT.0000000000001388

    authors: Siebelt M,Hartholt KA,van Winden DFM,Boot F,Papathanasiou D,Verdouw BC,de Vries MR,Mathijssen NM,Kraan GA

    更新日期:2019-04-01 00:00:00

  • 9. Effects of Low-Intensity Pulsed Ultrasound (LIPUS) on Osteoclasts and Osteoblasts: Analysis Using an Assay System With Fish Scale as a Model of Bone.

    abstract:OBJECTIVE:Low-intensity pulsed ultrasound (LIPUS) provides noninvasive therapeutic treatment to accelerate fracture repair and distraction osteogenesis. However, most studies concerning the influence of LIPUS on bone metabolism have been conducted in vivo systems using osteoblastic cells. Therefore, details of the dire...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000489982.40329.52

    authors: Suzuki N,Hanmoto T,Ikegame M,Furusawa Y,Tabuchi Y,Kondo T,Kitamura K,Sekiguchi T,Mikuni-Takagaki Y,Hattori A

    更新日期:2016-08-01 00:00:00

  • Anterior intrapelvic modification to the ilioinguinal approach.

    abstract::Anterior approaches to the pelvis for acetabular surgery require an intimate knowledge of pelvic anatomy. The utilitarian anterior approach is the ilioinguinal approach. This article will describe a technique for modifying the medial window of the ilioinguinal approach to facilitate intrapelvic visualization and instr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000266

    authors: Hagen JE,Weatherford BM,Nascone JW,Sciadini MF

    更新日期:2015-02-01 00:00:00

  • Cannulated hip screws: a study of fixation integrity, cut-out resistance, and high-cycle bending fatigue performance.

    abstract::One major advancement in the treatment of femoral neck fractures has been the development of cannulated screws. This study investigates the integrity of five commercially available cannulated screw systems. Transcervical fractures were created in 25 adult femora and repaired by three cannulated hip screws of a randoml...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-199408000-00004

    authors: Rouleau JP,Blasier RB,Tsai E,Goldstein SA

    更新日期:1994-08-01 00:00:00

  • Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate.

    abstract:OBJECTIVES:To document the high failure rate of a specific implant: the Synthes Variable Angle (VA) Locking Distal Femur Plate. DESIGN:Retrospective. SETTING:Urban University Level I Trauma Center. PATIENT/PARTICIPANTS:All distal femur fractures (OTA/AO 33-A, B, C) treated from March 2011 through August 2013 were re...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000391

    authors: Tank JC,Schneider PS,Davis E,Galpin M,Prasarn ML,Choo AM,Munz JW,Achor TS,Kellam JF,Gary JL

    更新日期:2016-01-01 00:00:00

  • The Community Orthopaedic Surgeon Taking Trauma Call: Lateral Humeral Condyle Fracture Pearls and Pitfalls.

    abstract::Lateral condyle fractures are second only to supracondylar humeral fractures when it comes to pediatric elbow fractures. Whether minimally displaced or substantially displaced, these growth plate fractures may present significant treatment challenges. These include nonunion, malunion, avascular necrosis, and growth di...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000001543

    authors: Ho CA,Mehlman CT

    更新日期:2019-08-01 00:00:00

  • Non-invasive low-intensity pulsed ultrasound accelerates bone healing in the rabbit.

    abstract::The effect of ultrasound (US) on the rate of fibula osteotomy healing in 139 mature New Zealand white rabbits was assessed in this study. Bilateral midshaft fibular osteotomies were made using a 1-mm Gigli saw. US was noninvasively applied to one limb for 20 minutes daily, while the contralateral limb served as a cont...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199004030-00002

    authors: Pilla AA,Mont MA,Nasser PR,Khan SA,Figueiredo M,Kaufman JJ,Siffert RS

    更新日期:1990-01-01 00:00:00

  • Complications of locking plate fixation in complex proximal tibia injuries.

    abstract:OBJECTIVES:To report the complications and pitfalls in the treatment of complex injuries of the proximal tibia when locking plates are used. DESIGN, SETTING, AND PATIENTS:This was a retrospective case series conducted at a university Level I trauma center. Thirty-seven patients with complex proximal tibia fractures (4...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318030df96

    authors: Phisitkul P,McKinley TO,Nepola JV,Marsh JL

    更新日期:2007-02-01 00:00:00

  • Subchondral screw fixation of cervical hip fractures: joint congruence studied with combined arthrography and tomography.

    abstract::This study was done to determine whether fixation with the Uppsala internal fixation technique into the subchondral bone of the femoral head in the treatment of cervical hip fractures could lead to elevation of the femoral head cartilage. Combined arthrography and frontal tomography of the hip joint in the plane of th...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-198909000-00004

    authors: Rehnberg L,Olerud C,Sahlstedt B

    更新日期:1989-01-01 00:00:00

  • Intraoperative fluoroscopy to evaluate fracture reduction and hardware placement during acetabular surgery.

    abstract:OBJECTIVES:To evaluate use of intraoperative fluoroscopy during acetabular surgery to determine fracture reduction and accurate placement of screws. DESIGN:Retrospective. SETTING:Level I trauma center. PARTICIPANTS:Thirty patients with thirty-two acetabular fractures. INTERVENTION:Patients were evaluated with fluor...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199908000-00004

    authors: Norris BL,Hahn DH,Bosse MJ,Kellam JF,Sims SH

    更新日期:1999-08-01 00:00:00

  • Use of the Medoff sliding plate for subtrochanteric hip fractures.

    abstract:OBJECTIVE:To evaluate the effects of dynamization of a sliding hip screw plate on the fixation stability for several types of subtrochanteric fractures. Clinical results of treating reverse oblique fractures occasionally show medialization of the femoral shaft. DESIGN:Two types of plate dynamization were compared usin...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199704000-00007

    authors: Kummer FJ,Pearlman CA,Koval KJ,Ceder L

    更新日期:1997-04-01 00:00:00