Complex volar distal radioulnar joint dislocation occurring in a Galeazzi fracture.

Abstract:

:The Galeazzi fracture-dislocation of the forearm consists of a transverse or short oblique fracture of the radius at the junction of the middle and distal thirds with an associated subluxation or dislocation of the distal radioulnar joint. Anatomic reduction with rigid internal fixation of the radius typically produces anatomic reduction of the distal radioulnar joint and is the favored treatment. At least three cases of a mechanically blocked distal radioulnar joint requiring open reduction through a separate exposure have been reported. In all three cases there was dorsal displacement of the ulna. We report a case of an irreducible volar dislocation of the distal radioulnar joint following open anatomic reduction of the radius.

journal_name

J Orthop Trauma

authors

Giangarra CE,Chandler RW

doi

10.1097/00005131-198903010-00015

subject

Has Abstract

pub_date

1989-01-01 00:00:00

pages

76-9

issue

1

eissn

0890-5339

issn

1531-2291

journal_volume

3

pub_type

杂志文章
  • Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy.

    abstract::We present the case of an intraforaminal iliosacral screw placed percutaneously with aid of C-arm using inlet, outlet, and lateral views of the pelvis. The iliosacral screw was placed above the S1 foramen on the outlet view, into the middle of S1 via the ala on the inlet view, and below the cortical shadow of the ala ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200502000-00010

    authors: Sagi HC,Lindvall EM

    更新日期:2005-02-01 00:00:00

  • Biomechanical Assessment of Locking Plate Fixation of Comminuted Proximal Olecranon Fractures.

    abstract:OBJECTIVES:To determine if mean ultimate strength or failure mechanism differed between comminuted olecranon fractures created at the proximal 25% or 50% of the trochlear notch and fixed with precontoured posterior locking plates (PLPs). METHODS:Comminuted osteotomies were created in 10 matched pairs of cadaveric uppe...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001279

    authors: Fantry A,Sobel A,Capito N,Hodax JD,Pidgeon T,Koruprolu S,Rich R,Fava JL,Green A,Paxton S

    更新日期:2018-11-01 00:00:00

  • The use of Ender nails in femoral shaft fractures: what are the remaining indications?

    abstract::The use of Ender nails for the treatment of femoral shaft fractures has been described as technically easier and less time consuming than current intramedullary nailing techniques. We reviewed our results with unlocked Ender nails in 26 stable and 17 unstable fracture patterns an average of 3-4 years after injury. Bec...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199209000-00008

    authors: Herscovici D Jr,Scott DM,Behrens F,Nelson B,Benton J

    更新日期:1992-01-01 00:00:00

  • Does malrotation following MIPO treatment of distal tibia metaphyseal fractures effect the functional results of the ankle and knee joints?

    abstract:OBJECTIVES:To investigate whether rotational malalignment of tibia, after fracture management with minimally invasive plate osteosynthesis technique (MIPO), leads to impaired results in knee and ankle joint functional scores. DESIGN:Prospectively collected data was retrospectively analyzed for this study. SETTING:Lev...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000002053

    authors: Çepni Ş,Yaman F,Veizi E,Fırat A,ÇayAssoc N,Tecimel O

    更新日期:2020-12-31 00:00:00

  • A biomechanical analysis of internal fixation of complex tibial plateau fractures.

    abstract:OBJECTIVE:To compare the mechanical stability of fixation of an unstable bicondylar tibial plateau fracture with several different fixation techniques in a cadaveric model. DESIGN:Randomized laboratory investigation using a simulated bicondylar tibial plateau fracture with metaphyseal-diaphyseal dissociation. SETTING...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-199911000-00005

    authors: Horwitz DS,Bachus KN,Craig MA,Peters CL

    更新日期:1999-11-01 00:00:00

  • Periprosthetic femur fractures.

    abstract::Successful treatment of periprosthetic femur fractures, like all fractures, requires careful attention to understand the fracture pattern nuances, identifying and executing a rational treatment approach, and providing an appropriate postoperative recovery protocol. Unlike most other fractures, modification of standard...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000282

    authors: Ricci WM

    更新日期:2015-03-01 00:00:00

  • The realities of relationship failure.

    abstract::Young surgeons and their spouses experience a myriad of stresses in the first few years of practice. Issues related to job search, moving to a new community, learning one's craft, time management, changes to spouse's career, child rearing, and the ever blurring line between work time and free time may all contribute t...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182641fd8

    authors: Dunbar RP Jr

    更新日期:2012-09-01 00:00:00

  • Heterotopic ossification of the quadriceps following distal femoral traction: a report of three cases and a review of the literature.

    abstract:SUMMARY:We present the previously unreported complication of symptomatic heterotopic ossification of the quadriceps following placement of a large-diameter Steinmann pin for the purpose of temporary skeletal traction. Following the development of distal quadriceps heterotopic bone formation in three patients, we conduc...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/00005131-200404000-00010

    authors: Specht LM,Gupta S,Egol KA,Koval KJ

    更新日期:2004-04-01 00:00:00

  • Deltoid compartment syndrome after antegrade humeral nailing.

    abstract::Acute compartment syndrome of the deltoid is rare with only 6 cases reported in the literature. To our knowledge, there are no reported cases of deltoid compartment syndrome after surgery on the shoulder. In this case, the patient developed a tense painful anterior deltoid 3 hours after antegrade nailing of a segmenta...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318199e83c

    authors: Gaffney D,Slabaugh M

    更新日期:2009-03-01 00:00:00

  • Comparison of cannulated screw with tension band wiring versus compressive cannulated locking bolt and nut device (CompresSURE) in patella fractures-a cadaveric biomechanical study.

    abstract:OBJECTIVE:The purpose of this study was to determine if proximity of cannulated lag screws to the articular surface of the patella combined with the tension band technique affects resistance to fracture gap opening, and if an alternative locking nut and bolt device without a tension band behaves in a biomechanically si...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31826f5985

    authors: Domby B,Henderson E,Nayak A,Erdoğan M,Gutierrez S,Santoni BG,Sagi HC

    更新日期:2012-12-01 00:00:00

  • A mechanical comparison of the locking compression plate (LCP) and the low contact-dynamic compression plate (DCP) in an osteoporotic bone model.

    abstract:OBJECTIVE:To determine if locking compression plates (LCP) are mechanically advantageous compared to low-contact dynamic compression plates (DCP) when used as a bridging plate in a synthetic model of osteoporotic bone. METHODS:Five synthetic bars (Synbone Osteoporotic bone) were initially tested in compression and the...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318160c84c

    authors: Snow M,Thompson G,Turner PG

    更新日期:2008-02-01 00:00:00

  • Pullout force of power-driven staples in cadaveric femoral metaphysis.

    abstract::The maximum pullout force in the distal metaphysis of cadaver femurs was investigated using a commercially available, pneumatically inserted staple. In paired studies, a significantly greater pullout force was required in the power-driven staples than in an almost identical sized hand-driven staple. A nonlinear relati...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199004020-00009

    authors: McCombe PF,Thomas AM,Pynsent PB,Thompson AG

    更新日期:1990-01-01 00:00:00

  • Levels of Evidence in Orthopaedic Trauma Literature.

    abstract:OBJECTIVE:To review and critically assess trends observed regarding the levels of evidence in published articles in orthopaedic traumatology literature. DATA SOURCES:The Journal of Orthopaedic Trauma, Journal of Bone and Joint Surgery-American, and Clinical Orthopaedics and Related Research. STUDY SELECTION:All artic...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000557

    authors: Scheschuk JP,Mostello AJ,Lombardi NJ,Maltenfort MG,Freedman KB,Tjoumakaris FP

    更新日期:2016-07-01 00:00:00

  • Syndesmotic Ankle Fractures.

    abstract:OBJECTIVES:The diagnosis and treatment of syndesmotic ankle fractures is controversial. This systematic review was performed to clarify the current understanding addressing several clinical questions that arise in the treatment of such injuries. DATA SOURCES:The English language literature was searched using PubMed, E...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000937

    authors: Michelson JD,Wright M,Blankstein M

    更新日期:2018-01-01 00:00:00

  • Indications and Clinical Results of Radial Head Replacement: Has Anything Changed?

    abstract::Radial head fractures are common injuries comprising 1/3 of the fractures about the elbow. As a secondary valgus stabilizer of the elbow, radial head fractures can compromise elbow stability leading to long-term pain, dysfunction, and degenerative change. Furthermore, radial head fractures can be accompanied by associ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000001641

    authors: Eyberg BA,McKee MD

    更新日期:2019-12-01 00:00:00

  • Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures.

    abstract:OBJECTIVES:Malalignment has been frequently reported after intramedullary stabilization of distal tibia fractures. Nails have also been associated with knee pain in several studies. Historically, plate fixation has resulted in increased risks of infection and nonunion. Our purposes were to compare plate and nail stabil...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/BOT.0b013e318213f709

    authors: Vallier HA,Cureton BA,Patterson BM

    更新日期:2011-12-01 00:00:00

  • Severe open tibial fractures: a study protocol.

    abstract::A prospective randomized study of severe open tibial fractures (Type II and III) was performed. Individual fractures were randomized to treatment groups according to initial antibiotic therapy: One consisted of a first-generation cephalosporin, and the other consisted of a third-generation cephalosporin. Initial antib...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-198802030-00001

    authors: Johnson KD,Bone LB,Scheinberg R

    更新日期:1988-01-01 00:00:00

  • Biomechanical study of atlantoaxial arthrodesis: transarticular screw fixation versus modified Brooks posterior wiring.

    abstract:OBJECTIVE:The purpose of the present study was to compare the biomechanical stability of C1 and C2 vertebrae after treatment of ligamentous instability by either modified Brooks posterior wiring (MB) or transarticular screw (TAS) techniques. We hypothesized that the TAS technique would be more stable because of direct ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199909000-00004

    authors: Mitchell TC,Sadasivan KK,Ogden AL,Mayeux RH,Mukherjee DP,Albright JA

    更新日期:1999-09-01 00:00:00

  • A staged protocol for soft tissue management in the treatment of complex pilon fractures.

    abstract:OBJECTIVE:To determine whether open reduction and internal fixation of intra-articular pilon fractures using a staged treatment protocol results in minimal surgical wound complications. DESIGN:Retrospective. SETTING:Level 1 trauma center. PATIENTS/PARTICIPANTS:Between January 1991 and December 1996, 226 pilon fractu...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199902000-00002

    authors: Sirkin M,Sanders R,DiPasquale T,Herscovici D Jr

    更新日期:1999-02-01 00:00:00

  • Dual-purpose bone grafts improve healing and reduce infection.

    abstract:OBJECTIVE:To determine if a dual-purpose bone graft can regenerate bone and reduce infection in highly contaminated bone critical size defects in rats. METHODS:Biodegradable polyurethane (PUR) scaffolds were loaded with recombinant human bone morphogenetic protein-2 (BMP-2) and vancomycin (Vanc). The release kinetics ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31821f624c

    authors: Guelcher SA,Brown KV,Li B,Guda T,Lee BH,Wenke JC

    更新日期:2011-08-01 00:00:00

  • Intrawound Antibiotic Powder in Acetabular Fracture Open Reduction Internal Fixation Does Not Reduce Surgical Site Infections.

    abstract:OBJECTIVES:To compare the risks of surgical site infection (SSI) and postoperative complications after acetabular fracture open reduction internal fixation (ORIF) in patients receiving topical intrawound antibiotic powder compared to those not receiving antibiotic powder (control group). DESIGN:Retrospective cohort SE...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001943

    authors: Cichos KH,Spitler CA,Quade JH,Ponce BA,McGwin G Jr,Ghanem ES

    更新日期:2020-09-02 00:00:00

  • The "Gull Sign": a harbinger of failure for internal fixation of geriatric acetabular fractures.

    abstract:OBJECTIVES:To identify factors affecting the outcomes of surgery for acetabular fracture in patients over the age of 60 years. DESIGN:Retrospective review of records and radiographs; current examination, radiographs and outcome surveys when possible. SETTING:Academic, Level 1 trauma center. PATIENTS/PARTICIPANTS:For...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200310000-00005

    authors: Anglen JO,Burd TA,Hendricks KJ,Harrison P

    更新日期:2003-10-01 00:00:00

  • Immediate interlocking nailing of fractures of the femur caused by low- to mid-velocity gunshots.

    abstract::A retrospective review of 39 fractures of the femur in 37 patients caused by low- and mid-velocity handgun missiles treated with static interlocking nailing within 18 h of injury was conducted to evaluate the efficacy, safety, and cost savings of immediate intramedullary nailing in these injuries. Patients were follow...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199404000-00010

    authors: Nowotarski P,Brumback RJ

    更新日期:1994-01-01 00:00:00

  • The biomechanical effect of high-pressure irrigation on diaphyseal fracture healing in vivo.

    abstract:OBJECTIVES:To evaluate the effect of both high-pressure pulsatile lavage and bulb syringe irrigation on the biomechanical parameters of fracture healing using an in vivo open noncontaminated diaphyseal femoral fracture model in rats. BACKGROUND:The utility of high-pressure pulsatile lavage irrigation on soft tissue de...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200207000-00008

    authors: Adili A,Bhandari M,Schemitsch EH

    更新日期:2002-07-01 00:00:00

  • No effect of low-intensity ultrasound on healing time of intramedullary fixed tibial fractures.

    abstract:OBJECTIVE:To determine whether stimulation with low-intensity ultrasound will reduce the radiologic healing time of fresh tibial shaft fractures fixed with a reamed and statically locked intramedullary rod. DESIGN:Prospective, randomized, double blinded, and placebo controlled. PATIENTS AND METHODS:Thirty-two adult p...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-199905000-00005

    authors: Emami A,Petrén-Mallmin M,Larsson S

    更新日期:1999-05-01 00:00:00

  • Inflammation, Bone Healing, and Anti-Inflammatory Drugs: An Update.

    abstract::Fracture healing is a unique multifaceted process requiring the presence of cells, molecular mediators, and angiogenic factors. The state of inflammation dominates the initial phase, but the ideal magnitude and duration of the process for an optimal outcome remains obscure. Biological response modifiers, such as plate...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000465

    authors: Giannoudis PV,Hak D,Sanders D,Donohoe E,Tosounidis T,Bahney C

    更新日期:2015-12-01 00:00:00

  • Convergent radioulnar translocation with radial head fracture in a child: a case report and review of the literature.

    abstract:SUMMARY:Convergent type radioulnar translocation is an extremely rare form of injury occurring in a growing child. We report a case of convergent radioulnar translocation along with a radial head fracture in a young child. Open reduction of the elbow and internal fixation of the radial head fragment helped in achieving...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e31821d7fd5

    authors: Agashe MV,Samant A,Aroojis AJ

    更新日期:2012-04-01 00:00:00

  • Mechanism of Injury Differentiates Risk Factors for Mortality in Geriatric Trauma Patients.

    abstract:OBJECTIVES:To evaluate the relationship between mechanism of injury and mortality in geriatric trauma patients and the ability of existing injury severity indices (ISIs) to assess mortality. DESIGN:Retrospective review. SETTING:Urban level 1 trauma center. PARTICIPANTS:Four thousand five hundred forty-five trauma pa...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000281

    authors: Konda SR,Lack WD,Seymour RB,Karunakar MA

    更新日期:2015-07-01 00:00:00

  • Nonunion of capital femoral physeal fracture with a large metaphyseal fragment.

    abstract::This report presents a case demonstrating the nonunion of a capital femoral physeal fracture with a large metaphyseal fragment in a 10-year-old boy. To our knowledge, there is no previously reported case of this type of nonunion. The treatment of this nonunion presented a potential risk of premature physeal closure an...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181c83a3b

    authors: Yukata K,Kubo T,Matsui Y,Koizumi T,Takata S,Yasui N

    更新日期:2010-08-01 00:00:00

  • Partridge osteosynthesis: a prospective clinical study on the use of nylon cerclage bands and plates in the treatment of periprosthetic femoral shaft fractures.

    abstract:OBJECTIVE:To evaluate the clinical use of the Partridge osteosynthesis in periprosthetic femoral fractures. DESIGN AND SETTING:Prospective nonrandomized clinical study. PATIENTS:Over a ten-year period, 222 patients presenting with femoral fractures near the tip of a hip prosthesis were treated with the Partridge syst...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章

    doi:10.1097/00005131-200101000-00011

    authors: de Ridder VA,de Lange S,Koomen AR,Heatley FW

    更新日期:2001-01-01 00:00:00