Triangular osteosynthesis of vertically unstable sacrum fractures: a new concept allowing early weight-bearing.

Abstract:

OBJECTIVE:Presentation of a new triangular osteosynthesis technique that permits early weight-bearing in vertically unstable sacral fractures. DESIGN:Retrospective evaluation of a consecutive series. SETTING:Level I trauma center. PATIENTS:Thirty-four patients, twenty-eight of whom were polytraumatized, all with vertically unstable sacral fractures. This group included eight women and twenty-six men, with a mean age of thirty-five years. Average time between trauma and definite operation was thirteen days (range 0 to 28 days). INTERVENTIONS:All patients underwent triangular osteosynthesis using a combination of a vertical vertebropelvic distraction osteosynthesis (pedicle screw system) and a transverse fixation of the sacrum fracture with either iliosacral screws or transsacral plating. Immediate postoperative weight-bearing was permitted postoperatively. RESULTS:Nineteen patients were treated with early progressive weight-bearing and advanced to full weight-bearing, on average, after twenty-three days (range 8 to 70 days). Three of the thirty-four patients (9 percent) experienced loosening of hardware, including two patients (6 percent) who required secondary intervention because of loss of the original reduction. Further complications included one pulmonary embolism (3 percent), one iatrogenic nerve lesion (3 percent), one wound necrosis (3 percent), and two local infections (6 percent). CONCLUSIONS:Triangular osteosynthesis is a demanding procedure that can be performed on vertically unstable sacral fractures to allow early progressive weight-bearing with an acceptable complication rate.

journal_name

J Orthop Trauma

authors

Schildhauer TA,Josten C,Muhr G

doi

10.1097/00005131-199806000-00002

subject

Has Abstract

pub_date

1998-06-01 00:00:00

pages

307-14

issue

5

eissn

0890-5339

issn

1531-2291

journal_volume

12

pub_type

杂志文章
  • Split fractures of the lateral tibial plateau: evaluation of three fixation methods.

    abstract::A laboratory study was performed to compare the stability and ultimate strength of three standard fixation techniques for split-type lateral tibial plateau fractures. The three methods of fixation were (a) three 6.5-mm cancellous lag screws with washers; (b) two 6.5-mm cancellous lag screws with washers and an additio...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199607000-00003

    authors: Koval KJ,Polatsch D,Kummer FJ,Cheng D,Zuckerman JD

    更新日期:1996-01-01 00:00:00

  • Connective tissue parameters in experimental nonunion.

    abstract::A previously developed experimental model for producing nonunions in rats was used to study the biochemical changes of connective tissue parameters in impaired fracture repair. The model is based on rotational instability between the fracture fragments. A mid-diaphyseal femoral osteotomy was performed on 30 male rats ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199602000-00007

    authors: Hietaniemi K,Paavolainen P,Penttinen R

    更新日期:1996-01-01 00:00:00

  • Operative fixation of acetabular fractures in the pregnant patient.

    abstract:OBJECTIVE:To describe in utero radiation exposures in pregnant patients undergoing acetabular fracture repair. DESIGN:Retrospective case series. SETTING:University-affiliated regional trauma center. PATIENT/PARTICIPANTS:Eight pregnant patients with acetabular fractures treated over a 6-year period. There were an add...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181847a42

    authors: Porter SE,Russell GV,Qin Z,Graves ML

    更新日期:2008-09-01 00:00:00

  • Does the Coexistence of Multiple Segmental Rib Fractures in Polytrauma Patients Presenting With "Major" Vertebral Fracture Affect Care and Acute Outcomes?

    abstract:OBJECTIVE:To determine whether operating on "major" vertebral fractures leads to premature abortion of surgery and/or other acute cardiopulmonary complications. DESIGN:Retrospective review. CLINICAL SETTING:Level 1 trauma center. PATIENTS/PARTICIPANTS AND INTERVENTION:We retrospectively queried our institutional Tra...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001316

    authors: Alvi MA,Kapurch JR 2nd,Ivanov DV,Kerezoudis P,Bydon M,Freedman BA

    更新日期:2019-01-01 00:00:00

  • Cannulated hip screws: a study of fixation integrity, cut-out resistance, and high-cycle bending fatigue performance.

    abstract::One major advancement in the treatment of femoral neck fractures has been the development of cannulated screws. This study investigates the integrity of five commercially available cannulated screw systems. Transcervical fractures were created in 25 adult femora and repaired by three cannulated hip screws of a randoml...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-199408000-00004

    authors: Rouleau JP,Blasier RB,Tsai E,Goldstein SA

    更新日期:1994-08-01 00:00:00

  • Bone regeneration with resorbable polymeric membranes: treatment of diaphyseal bone defects in the rabbit radius with poly(L-lactide) membrane. A pilot study.

    abstract::Tubular poly(L-lactide) membranes with a pore size of 5-15 microns and a molecular weight of 70,000 Daltons were implanted into 24 New Zealand skeletally mature rabbits to cover 10-mm mid-diaphyseal defects of the radius of the forelimb. An identical defect on the contralateral limb was not treated with the membrane a...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199604000-00006

    authors: Meinig RP,Rahn B,Perren SM,Gogolewski S

    更新日期:1996-01-01 00:00:00

  • The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures.

    abstract:OBJECTIVES:The purpose of this study was to evaluate forearm rotation after volar plating of the distal radius fractures with and without pronator quadratus repair. DESIGN:This was an institutional review board-approved retrospective review of prospectively collected data. SETTING:The study was conducted at an Academ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182539333

    authors: Hershman SH,Immerman I,Bechtel C,Lekic N,Paksima N,Egol KA

    更新日期:2013-03-01 00:00:00

  • Modified Technique of Separate Vertical Wiring for the Fixation of Patellar Inferior Pole Fracture.

    abstract::To evaluate the biomechanical and clinical results of modified separate vertical wiring technique (SVW) for inferior pole patellar fracture repair we conducted a finite element biomechanical study using 2 fixation methods and evaluated a clinical series of eleven patients. The modified SVW technique was an effective, ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001080

    authors: He S,Huang X,Yan B,Zhu J,Bao N,Zhao J

    更新日期:2018-04-01 00:00:00

  • The upper sacral nerve root tunnel: an anatomic and clinical study.

    abstract:OBJECTIVES:To radiographically demonstrate the upper sacral nerve root tunnel (USNRT) in both cadaveric specimens and a clinical cohort and to quantify its clinical relevance. SETTING:Level 1 trauma center and anatomy laboratory. PATIENTS AND PARTICIPANTS:Eleven cadaveric pelves and 23 consecutive patients who underw...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181a2e419

    authors: Farrell ED,Gardner MJ,Krieg JC,Chip Routt ML Jr

    更新日期:2009-05-01 00:00:00

  • Traumatic anterior dislocation of the radial head in an adult.

    abstract::We report an isolated anterior dislocation of the radial head in an adult after sustaining a fall on the outstretched arm. Based on history and presentation, we speculate that the injury occurred in a position of hyperextension and supination. Reduction was achieved by a pronation maneuver. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199505000-00014

    authors: Bonatus T,Chapman MW,Felix N

    更新日期:1995-01-01 00:00:00

  • Functional and radiographic results of patients with syndesmotic screw fixation: implications for screw removal.

    abstract:OBJECTIVE:Screw fixation of the injured syndesmosis restores stability but may reduce motion. The purpose of this study is to determine whether functional outcomes and radiographic results after ankle fracture are affected by the status of the syndesmosis screw. DESIGN:Retrospective review of a consecutive clinical se...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181a9f7a5

    authors: Manjoo A,Sanders DW,Tieszer C,MacLeod MD

    更新日期:2010-01-01 00:00:00

  • Failure of exchange reamed intramedullary nails for ununited femoral shaft fractures.

    abstract:OBJECTIVE:To determine the effectiveness of exchange reamed nails for treatment of aseptic femoral delayed unions and nonunions. DESIGN:Retrospective chart review. PATIENTS:Nineteen patients admitted to the Carolinas Medical Center Level I trauma center from 1990 to 1996 for repair of femoral shaft fracture nonunion ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200006000-00005

    authors: Weresh MJ,Hakanson R,Stover MD,Sims SH,Kellam JF,Bosse MJ

    更新日期:2000-06-01 00:00:00

  • Donor Site Morbidity After Anterior Iliac Bone Graft Harvesting.

    abstract:OBJECTIVES:The objective of this study was to evaluate donor site morbidity associated with anterior iliac crest bone graft harvesting for orthopaedic trauma reconstructions. DESIGN:Retrospective case series. SETTING:Level 1 trauma center. PATIENTS:Forty-Six consecutive patients who had undergone anterior iliac cres...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000551

    authors: Shin SR,Tornetta P 3rd

    更新日期:2016-06-01 00:00:00

  • Intraoperative fluoroscopy to evaluate fracture reduction and hardware placement during acetabular surgery.

    abstract:OBJECTIVES:To evaluate use of intraoperative fluoroscopy during acetabular surgery to determine fracture reduction and accurate placement of screws. DESIGN:Retrospective. SETTING:Level I trauma center. PARTICIPANTS:Thirty patients with thirty-two acetabular fractures. INTERVENTION:Patients were evaluated with fluor...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199908000-00004

    authors: Norris BL,Hahn DH,Bosse MJ,Kellam JF,Sims SH

    更新日期:1999-08-01 00:00:00

  • Patellar fixation protected with a load-sharing cable: a mechanical and clinical study.

    abstract::The stability of patellar fracture fixation protected with a load-sharing cable was studied in cadavers. A transverse patellar osteotomy was produced and stabilized with standard patellar fixation with or without a figure-of-eight cable that extends from the proximal pole of the patella to the tibial tubercle. Standar...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-198802030-00010

    authors: Perry CR,McCarthy JA,Kain CC,Pearson RL

    更新日期:1988-01-01 00:00:00

  • Calcaneal Avulsion Fractures: A Multicenter Analysis of Soft-Tissue Compromise and Early Fixation Failure.

    abstract:OBJECTIVE:To characterize the presentation and outcomes of calcaneal avulsion fractures. DESIGN:Case series. SETTING:Two ACS Level I trauma centers. PATIENTS/PARTICIPANTS:Forty-seven calcaneal avulsion fractures isolated from a cohort of 1365 calcaneus fractures treated over a 17-year period. MAIN OUTCOME MEASUREME...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000001582

    authors: Mitchell PM,OʼNeill DE,Branch E,Mir HR,Sanders RW,Collinge CA

    更新日期:2019-11-01 00:00:00

  • Mechanism of Injury Differentiates Risk Factors for Mortality in Geriatric Trauma Patients.

    abstract:OBJECTIVES:To evaluate the relationship between mechanism of injury and mortality in geriatric trauma patients and the ability of existing injury severity indices (ISIs) to assess mortality. DESIGN:Retrospective review. SETTING:Urban level 1 trauma center. PARTICIPANTS:Four thousand five hundred forty-five trauma pa...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000281

    authors: Konda SR,Lack WD,Seymour RB,Karunakar MA

    更新日期:2015-07-01 00:00:00

  • Stabilization of pediatric diaphyseal femur fractures with flexible intramedullary nails (a technique paper).

    abstract::The indications for surgical stabilization of a pediatric diaphyseal femur fracture are expanding. Children with multiple system injuries, a head injury, and/or multiple fractures have fewer local and distant complications if the femur fracture is treated operatively. Other indications include a pathological fracture ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199212000-00011

    authors: Heinrich SD,Drvaric D,Darr K,MacEwen GD

    更新日期:1992-01-01 00:00:00

  • Regeneration of diaphyseal bone defects using resorbable poly(L/DL-lactide) and poly(D-lactide) membranes in the Yucatan pig model.

    abstract:OBJECTIVES:To determine the effects of tubular resorbable polymer membranes on the healing of a segmental diaphyseal bone defect. DESIGN:A randomized prospective study using the minipig model. Animals were evaluated with in vivo roentgenograms on a biweekly basis until explanted at twelve weeks. SETTING:After surgery...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199711000-00002

    authors: Meinig RP,Buesing CM,Helm J,Gogolewski S

    更新日期:1997-11-01 00:00:00

  • Femoral cortical stress lesions in long-term bisphosphonate therapy: a herald of impending fracture?

    abstract:OBJECTIVE:Lateral cortical stress reactions have been documented to precede femoral insufficiency fractures after long-term bisphosphonate therapy. We studied the natural history of femoral stress lesions associated with long-term bisphosphonate therapy. DESIGN AND SETTING:A retrospective clinical and radiologic revie...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181b6499b

    authors: Koh JS,Goh SK,Png MA,Kwek EB,Howe TS

    更新日期:2010-02-01 00:00:00

  • Nonunion of capital femoral physeal fracture with a large metaphyseal fragment.

    abstract::This report presents a case demonstrating the nonunion of a capital femoral physeal fracture with a large metaphyseal fragment in a 10-year-old boy. To our knowledge, there is no previously reported case of this type of nonunion. The treatment of this nonunion presented a potential risk of premature physeal closure an...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181c83a3b

    authors: Yukata K,Kubo T,Matsui Y,Koizumi T,Takata S,Yasui N

    更新日期:2010-08-01 00:00:00

  • Technique for removal of intramedullary nails when there is failure of the proximal extraction device: a report of three cases.

    abstract::When attempting to remove an intramedullary nail, the extraction device can fail. This can occur due to stripping of the proximal threads or, more rarely, due to entrapped broken metal devices (impacted cap screws; broken introducers, extractors, or taps). This latter situation is particularly problematic if access to...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199702000-00012

    authors: Georgiadis GM,Heck BE,Ebraheim NA

    更新日期:1997-02-01 00:00:00

  • Compression plating versus hackethal nailing in closed humeral shaft fractures failing nonoperative reduction.

    abstract::Prospectively, 40 patients with an average age of 45 (20-65) with closed transverse fractures of the middle one-third of the humerus without associated radial nerve palsy were treated. All had failed nonoperative reduction and were then operated on with either compression plating or intramedullary fixation with Hacket...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-199506000-00003

    authors: Rodríguez-Merchán EC

    更新日期:1995-06-01 00:00:00

  • Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures.

    abstract:OBJECTIVES:Malalignment has been frequently reported after intramedullary stabilization of distal tibia fractures. Nails have also been associated with knee pain in several studies. Historically, plate fixation has resulted in increased risks of infection and nonunion. Our purposes were to compare plate and nail stabil...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/BOT.0b013e318213f709

    authors: Vallier HA,Cureton BA,Patterson BM

    更新日期:2011-12-01 00:00:00

  • Chipping and lengthening technique for delayed unions and nonunions with shortening or bone loss.

    abstract::Autologous bone graft is usually necessary for reconstruction of nonunions with shortening or bone loss. We developed a new technique to reconstruct such nonunions or delayed unions without bone grafting by chipping and lengthening of bone at the original fracture site. Five in six nonunions with shortening or bone lo...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318041f6d1

    authors: Matsushita T,Watanabe Y

    更新日期:2007-07-01 00:00:00

  • Management of distal humerus fractures with minifragment fixation.

    abstract::Minifragment implants provide several advantages for the stabilization of distal humerus fractures. Compared with small fragment implants, minifragment implants may provide enhanced fracture fixation because a greater number of screws can be placed into the distal fragments. In addition, minifragment plates are easier...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000157908.45939.d7

    authors: Russell GV Jr,Jarrett CA,Jones CB,Cole PA,Gates J

    更新日期:2005-08-01 00:00:00

  • Comparison of the 95-degree angled blade plate and the locking condylar plate for the treatment of distal femoral fractures.

    abstract:OBJECTIVES:In the distal femur, locked plating is efficacious when coronal fractures preclude the use of a conventional fixed-angle device. However, minimal comparative data exist for supracondylar fracture patterns, which could be treated with other devices. The purpose of this study was to compare the 95-degree angle...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318234d460

    authors: Vallier HA,Immler W

    更新日期:2012-06-01 00:00:00

  • Femoral fractures in Paget's disease.

    abstract::Since the original description of osteitis deformans, the treatment of femoral fractures occurring in this disease process has been difficult. A retrospective study of 35 fractures treated over an 8-year period was undertaken to identify the factors that influenced the results. The fractures were classified according ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-198912000-00011

    authors: Bidner S,Finnegan M

    更新日期:1989-01-01 00:00:00

  • Orthopaedic Trauma in the Developing World: Where Are the Gaps in Research and What Can Be Done?

    abstract:PURPOSE:There are an estimated 1.2 million deaths from road traffic injuries annually, disproportionately affecting patients in low-resource settings. The purpose of this scoping review is to identify knowledge gaps in global orthopaedic trauma in an effort to help prioritize future research. METHODS:Using the 6-stage...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000001293

    authors: Challa S,Wu HH,Cunningham BP,Liu M,Patel K,Shearer DW,Morshed S,Miclau T

    更新日期:2018-10-01 00:00:00

  • Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures.

    abstract:OBJECTIVE:Comparison between a Less Invasive Stabilization System (LISS) using monocortical screws with angular stability and two conventional plate systems Condylar Buttress Plate (CBP) and Dynamic Condylar Screw (DCS) for the treatment of distal femoral fractures with respect to biomechanical properties. DESIGN:Biom...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200109000-00004

    authors: Marti A,Fankhauser C,Frenk A,Cordey J,Gasser B

    更新日期:2001-09-01 00:00:00