Functional and radiographic results of patients with syndesmotic screw fixation: implications for screw removal.

Abstract:

OBJECTIVE:Screw fixation of the injured syndesmosis restores stability but may reduce motion. The purpose of this study is to determine whether functional outcomes and radiographic results after ankle fracture are affected by the status of the syndesmosis screw. DESIGN:Retrospective review of a consecutive clinical series. SETTING:Level 1 academic trauma center. PATIENTS:One hundred six adults were reviewed radiographically; mean follow up was 15 months (range, 4-30 months). Seventy-six of the 106 patients completed formal functional testing; mean follow up was 23 +/- 13 months (range, 12-32 months). INTERVENTION:Open reduction and internal fixation, including fixation of the tibiofibular syndesmosis. MAIN OUTCOME MEASUREMENTS:Patients with intact, broken or loose, or removed syndesmosis screws were compared. Functional outcomes were measured using the Lower Extremity Measure and the Olerud Molander ankle score. Radiologic review included tibiofibular clear space, tibiofibular overlap, and medial clear space. RESULTS:Functional outcomes were improved in patients with fractured, loosened, or removed screws compared with those with intact screws. The Lower Extremity Measure score for patients with intact screws was 70 +/- 6 compared with 85 +/- 3 for fractured, loosened, or removed screws (P = 0.01). The Olerud Molander ankle score for patients with intact screws was 47 +/- 8.0 compared with 64 +/- 4 for fractured, loosened, or removed screws (P = 0.04). There was no difference in outcome comparing fractured, loosened, and removed screws. The tibiofibular clear space was narrowed in patients with intact screws compared with removed, fractured, or loose screws. The tibiofibular clear space for intact screws was 3.1 +/- 0.2 compared with 4.1 +/- 0.2 for removed, fractured, or loosened screws (P = 0.005). There was no difference in outcome comparing large and small fragment screws. CONCLUSIONS:An intact syndesmosis screw was associated with a worse functional outcome compared with loose, fractured, or removed screws. However, there were no differences in functional outcomes comparing loose or fractured screws with removed screws. Screw removal is unlikely to benefit patients with loose or fractured screws but may be indicated in patients with intact syndesmosis screws.

journal_name

J Orthop Trauma

authors

Manjoo A,Sanders DW,Tieszer C,MacLeod MD

doi

10.1097/BOT.0b013e3181a9f7a5

subject

Has Abstract

pub_date

2010-01-01 00:00:00

pages

2-6

issue

1

eissn

0890-5339

issn

1531-2291

pii

00005131-201001000-00002

journal_volume

24

pub_type

杂志文章
  • The association between restraint system and upper extremity injury after motor vehicle collisions.

    abstract:OBJECTIVES:This study was designed to investigate the relationship between upper extremity (UE) injuries and occupant restraint systems among front seat occupants who were involved in frontal motor vehicle collisions (MVCs). DESIGN:Case-control. SETTING:The 1995 through 2002 National Automotive Sampling System (NASS)...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000161543.52643.ab

    authors: Goldman MW,MacLennan PA,McGwin G Jr,Lee DH,Sparks DR,Rue LW 3rd

    更新日期:2005-09-01 00:00:00

  • Volar dislocation of multiple carpometacarpal joints: report of four cases.

    abstract::Four acute cases of volar carpometacarpal dislocations of the medial four metacarpals were treated in our hospital's emergency room. Our initial diagnosis after clinical examination was confirmed by routine x-rays of the hand. Closed reduction was followed by percutaneous fixation of the carpometacarpal joints with Ki...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199809000-00019

    authors: Kumar S,Arora A,Jain AK,Agarwal A

    更新日期:1998-09-01 00:00:00

  • Low-energy femoral shaft fractures associated with alendronate use.

    abstract:OBJECTIVE:Increasing evidence suggests long-term alendronate use may overly suppress bone metabolism, limiting repair of microdamage and creating risk for insufficiency fractures. The purpose of this study is to demonstrate an association between alendronate use and a specific pattern of low-energy femoral shaft fractu...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318172841c

    authors: Neviaser AS,Lane JM,Lenart BA,Edobor-Osula F,Lorich DG

    更新日期:2008-05-01 00:00:00

  • Complications of nailing in closed tibial fractures.

    abstract::Reamed intramedullary nailing was used to treat 102 closed tibial shaft fractures. Although a high rate of union was achieved (98%), we noted a higher incidence of complications than previously reported. Thirty-five (37%) patients exhibited one or more components of malunion. In 17 (18%) patients, further operative pr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199509060-00004

    authors: Williams J,Gibbons M,Trundle H,Murray D,Worlock P

    更新日期:1995-01-01 00:00:00

  • The Effect of Insertion Technique on Temperatures for Standard and Self-Drilling External Fixation Pins.

    abstract:OBJECTIVES:No studies have assessed the effects of parameters associated with insertion temperature in modern self-drilling external fixation pins. The current study assessed how varying the presence of irrigation, insertion speed, and force impacted the insertion temperatures of 2 types of standard and self-drilling e...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000859

    authors: Manoogian S,Lee AK,Widmaier JC

    更新日期:2017-08-01 00:00:00

  • Marginal mandibular nerve palsy due to compression by a cervical hard collar.

    abstract::A case history of a trauma patient who developed a palsy of the marginal mandibular nerve from compression by a cervical spine hard collar is presented. After clinical and radiographic screening found no evidence of occult cervical spine pathology, the collar was removed; the palsy resolved uneventfully during the nex...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199504000-00015

    authors: Rodgers JA,Rodgers WB

    更新日期:1995-04-01 00:00:00

  • Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model.

    abstract:OBJECTIVES:Lateral locked plating for proximal tibial fractures with metaphyseal disruption provides a biomechanically stable and biologically favorable alternative to conventional medial/lateral plate fixation. New polyaxial screw technology incorporates expanding screw bushings, allowing variable angle screw placemen...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/QAI.0b013e3181a25368

    authors: Cullen AB,Curtiss S,Lee MA

    更新日期:2009-08-01 00:00:00

  • In vitro femoral stiffness after femoral neck osteotomy and osteosynthesis with defined surgical errors.

    abstract::In our search for an osteosynthesis device that would tolerate the surgical errors of the inexperienced surgeon, we tested in vitro femoral stiffness in 75 human osteoporotic femora after internal fixation of a cervical neck osteotomy using three commonly used devices: two von Bahr screws (A. Ericsson AB, Sweden), two...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199608000-00009

    authors: Hernefalk L,Messner K

    更新日期:1996-01-01 00:00:00

  • Fabrication of an Interlocked Antibiotic/Cement-Coated Carbon Fiber Nail for the Treatment of Long Bone Osteomyelitis.

    abstract::Successful management of intramedullary long bone osteomyelitis remains a challenge for both surgeons and patients. Patients are often immune compromised and have endured multiple surgeries. Treatment principles include antibiotic administration (systemically ± locally), surgical debridement of the infection site, and...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000587

    authors: Mauffrey C,Butler N,Hake ME

    更新日期:2016-08-01 00:00:00

  • The use of a biodegradable, load-bearing scaffold as a carrier for antibiotics in an infected open fracture model.

    abstract:OBJECTIVES:Open fractures with bone loss are common, disabling injuries. Biodegradable, load-bearing scaffolds able to carry high concentrations of local antibiotics are an emerging technology to address these injuries. This study investigates the use of such scaffolds with gentamicin (along with bone morphogenetic pro...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181ed1349

    authors: Stewart RL,Cox JT,Volgas D,Stannard J,Duffy L,Waites KB,Chu TM

    更新日期:2010-09-01 00:00:00

  • Posteromedial Approach to Tibial Plateau Fracture Nonunion.

    abstract::Tibial plateau fractures can involve planes that require reduction and stabilization from a posterior approach. This includes posteromedial, posterolateral, and posterior column shear type injuries. This video outlines the prone posteromedial approach to the tibial plateau for posterior column fracture exposure, reduc...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001826

    authors: Shields CN,Eftekhary N,Egol KA

    更新日期:2020-08-01 00:00:00

  • Foot Function After Surgically Treated Intraarticular Calcaneal Fractures: Correlation of Clinical and Pedobarographic Results of 65 Patients Followed for 8 Years.

    abstract:OBJECTIVES:To correlate functional deficits after surgical treatment of displaced intraarticular calcaneal fractures (DIACFs) as measured through dynamic pedobarography with clinical and radiographic long-term results. DESIGN:Retrospective single-center study. SETTING:Level 1 trauma center. PATIENTS:Sixty-five patie...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001325

    authors: Dürr C,Apinun J,Mittlmeier T,Rammelt S

    更新日期:2018-12-01 00:00:00

  • The "swashbuckler": a modified anterior approach for fractures of the distal femur.

    abstract::A modified anterior approach to the distal femur is presented. The approach allows surgical exposure of the entire articular surface of the distal femur. The quadriceps muscle bellies are spared during the approach. The skin incision used will not interfere with subsequent total knee arthroplasty, if posttraumatic art...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199902000-00012

    authors: Starr AJ,Jones AL,Reinert CM

    更新日期:1999-02-01 00:00:00

  • Mortality after pelvic fractures in the elderly.

    abstract::Theoretically, fissures and minor fractures of the pelvis sustained by the elderly after low-energy trauma may lead to thromboembolic complications. Few studies exist, but clinically, these injuries had been considered to have an excellent prognosis until a recent study reported a 10% fatality rate from pulmonary embo...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/00005131-198906000-00005

    authors: Rossvoll I,Finsen V

    更新日期:1989-01-01 00:00:00

  • The PFNA proximal femur nail in treatment of unstable proximal femur fractures--3 cases of postoperative perforation of the helical blade into the hip joint.

    abstract::The proximal femur nail antirotation represents a new generation of intramedullary nailing devices for fixation of stable and unstable trochanteric fractures of the proximal femur. We report 3 cases of postoperative perforation of the helical blade through the femoral head into the hip joint without any signs of rotat...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181893b1b

    authors: Brunner A,Jöckel JA,Babst R

    更新日期:2008-11-01 00:00:00

  • Suprapatellar Versus Infrapatellar Tibial Nail Insertion: A Prospective Randomized Control Pilot Study.

    abstract:PURPOSE:The purpose of this OTA-approved pilot study was to compare the clinical and functional outcomes of the knee joint after infrapatellar (IP) versus suprapatellar (SP) tibial nail insertion. DESIGN:Prospective, randomized. SETTING:Level I trauma center. METHODS:After institutional review board approval, skelet...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/BOT.0000000000000499

    authors: Chan DS,Serrano-Riera R,Griffing R,Steverson B,Infante A,Watson D,Sagi HC,Sanders RW

    更新日期:2016-03-01 00:00:00

  • Prolonged thromboprophylaxis with dalteparin after surgical treatment of achilles tendon rupture: a randomized, placebo-controlled study.

    abstract:OBJECTIVES:Prophylaxis against thromboembolic complications has become routine after major orthopedic surgery. In contrast, it remains an issue for debate whether prophylaxis after minor surgery and immobilization is necessary, even though these treatments are well-known risk factors for deep-vein thrombosis (DVT). The...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/01.bot.0000250741.65003.14

    authors: Lapidus LJ,Rosfors S,Ponzer S,Levander C,Elvin A,Lärfars G,de Bri E

    更新日期:2007-01-01 00:00:00

  • Mechanical failure after locking plate fixation of unstable intertrochanteric femur fractures.

    abstract:OBJECTIVES:The aim of this study was analyze modes of mechanical failure in a consecutive cohort of patients and establish possible risk factors. DESIGN:This was a retrospective cohort study. SETTING:The study was conducted at an academic level-1 trauma center. PATIENTS:Twenty-nine patients (mean age 56 years, range...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318251930d

    authors: Streubel PN,Moustoukas MJ,Obremskey WT

    更新日期:2013-01-01 00:00:00

  • Orthopaedic Trauma Association Annual Meeting Program Committee: Analysis of Impact of Committee Size and Review Process on Abstract Acceptance.

    abstract:OBJECTIVE:To evaluate whether scientific abstracts selected for podium presentation at the Orthopaedic Trauma Association (OTA) Annual Meeting differ based on the program committee size and/or the proportion of abstracts each committee member evaluates. METHODS:Abstract scores from the Orthopaedic Trauma Association p...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001108

    authors: OʼHara NN,Slobogean GP,Zhan M,Gardner MJ,McKee MD,Moore SM,Higgins TF,OʼToole RV,Orthopaedic Trauma Association Program Committee.

    更新日期:2018-05-01 00:00:00

  • Results of indirect reduction and plating of femoral shaft nonunions after intramedullary nailing.

    abstract:OBJECTIVE:To observe and report the clinical results of indirect plating techniques in the treatment of femoral shaft nonunions originally treated with intramedullary nailing. DESIGN:Prospective consecutive. SETTING:Regional trauma center. PATIENTS:A consecutive series of twenty-three patients with nonunion of femor...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200105000-00004

    authors: Bellabarba C,Ricci WM,Bolhofner BR

    更新日期:2001-05-01 00:00:00

  • Knee Disarticulations Versus Transfemoral Amputations: Functional Outcomes.

    abstract:OBJECTIVES:To determine whether there is a patient-reported functional difference between combat-related knee disarticulations (KDs) and transfemoral amputations (TFAs). SETTING:Role 3 Military Trauma Centers. PATIENTS:We identified and contacted all KDs and TFAs performed at the Walter Reed National Military Medical...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001440

    authors: Polfer EM,Hoyt BW,Bevevino AJ,Forsberg JA,Potter BK

    更新日期:2019-06-01 00:00:00

  • Stereo fluoroscopy-assisted distal interlocking of intramedullary nails.

    abstract::A simulation study of distal interlocking of an intramedullary nail was performed using newly devised, portable stereo fluoroscopy. Two intramedullary nails in which ten holes were drilled perpendicular to the long axis and at various angles to the diameter were inserted into a femoral and a tibial bone model. Ten dri...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199705000-00014

    authors: Ohe T,Nakamura K,Matsushita T,Nishiki M,Watanabe N,Matsumoto K

    更新日期:1997-05-01 00:00:00

  • Young Practitioners Forum: What Really Matters.

    abstract::After completing an orthopaedic trauma fellowship, what challenges will you have as regard to maintaining balance and perspective in your new position in society? How will you view yourself, family, and your profession? These are simple suggestions on maintaining passion for your profession. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000431

    authors: Russell TT

    更新日期:2015-11-01 00:00:00

  • Recombinant human bone morphogenic protein-7: applications for clinical trauma.

    abstract::Several clinical trials have examined the safety and efficacy of recombinant human bone morphogenic protein-7 (rhBMP-7) for osseous repair in clinical trauma. This article summarizes the results obtained from three recent clinical trials, which suggest that rhBMP-7 is useful in the treatment of tibial nonunion, long b...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200511101-00008

    authors: McKee MD

    更新日期:2005-11-01 00:00:00

  • Extra-articular malunions of the scapula: a comparison of functional outcome before and after reconstruction.

    abstract:OBJECTIVE:To assess surgical and functional results after corrective reconstruction of malunited, scapula neck or body fractures in patients who presented with chronic pain, limited range of motion, weakness, and gross deformity of the shoulder. DESIGN:Case series. SETTING:Level I teaching trauma center. PATIENTS:Be...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31820af67f

    authors: Cole PA,Talbot M,Schroder LK,Anavian J

    更新日期:2011-11-01 00:00:00

  • The Effectiveness of Negative Pressure Wound Therapy Versus Conventional Dressing in the Treatment of Open Fractures: A Systematic Review and Meta-Analysis.

    abstract:OBJECTIVES:To compare the efficacy of negative pressure wound therapy (NPWT) versus conventional dressings (CD) in the management of open fractures. DATA SOURCES:A systematic search of English articles in the PubMed/MEDLINE, Embase, and the Cochrane Library through April 2019 comparing NPWT versus CD in the management...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001750

    authors: Grant-Freemantle MC,Ryan ÉJ,Flynn SO,Moloney DP,Kelly MA,Coveney EI,OʼDaly BJ,Quinlan JF

    更新日期:2020-05-01 00:00:00

  • Pathomechanical significance of radial head subluxation in the onset of osteochondritis dissecans of the radial head.

    abstract::Osteochondritis dissecans of the elbow mainly involves the capitellum; however, no authors have reported the condition in the radial head with subluxation of the radial head. We report four cases in which osteochondritis dissecans involved the radial head and was accompanied by radial head subluxation. All patients we...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318214d678

    authors: Tatebe M,Hirata H,Shinohara T,Yamamoto M,Morita A,Horii E

    更新日期:2012-01-01 00:00:00

  • Biomechanical Assessment of Locked Plating for the Fixation of Patella Fractures.

    abstract:OBJECTIVE:To analyze the mechanical stability of locked plating in comparison with tension-band wiring for the fixation of fractures of the patella. METHODS:Biomechanical tests were performed on artificial foam patella specimens comparing an angular stable plate and monocortical screws with tension-band wiring. Tests ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000309

    authors: Wurm S,Augat P,Bühren V

    更新日期:2015-09-01 00:00:00

  • Syndesmotic instability in Weber B ankle fractures: a clinical evaluation.

    abstract:OBJECTIVE:Syndesmotic instability may coexist with unstable Weber B supination-external rotation (SE) lateral malleolar fractures. Current recommendations suggest that Weber B injuries should not have associated syndesmotic instability after open reduction and internal fixation of the lateral malleolus. The purpose of ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318157a63a

    authors: Stark E,Tornetta P 3rd,Creevy WR

    更新日期:2007-10-01 00:00:00

  • The effects of clopidogrel (Plavix) and other oral anticoagulants on early hip fracture surgery.

    abstract:OBJECTIVE:Risk for bleeding complications during and after early hip fracture surgery for patients taking clopidogrel and other anticoagulants have not been defined. The purpose of this study is to assess the perioperative bleeding risks and clinical outcome after early hip fracture surgery performed on patients taking...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318240d70f

    authors: Collinge CA,Kelly KC,Little B,Weaver T,Schuster RD

    更新日期:2012-10-01 00:00:00