Orthopaedic Trauma Association Annual Meeting Program Committee: Analysis of Impact of Committee Size and Review Process on Abstract Acceptance.

Abstract:

OBJECTIVE:To evaluate whether scientific abstracts selected for podium presentation at the Orthopaedic Trauma Association (OTA) Annual Meeting differ based on the program committee size and/or the proportion of abstracts each committee member evaluates. METHODS:Abstract scores from the Orthopaedic Trauma Association program committee from 2010 through 2016 were obtained. All members (range, 8-9) reviewed each clinical abstract (range, 506-778) each year in a blinded fashion. The 90 top-scoring abstracts were considered "accepted" for this study. To determine the effect of reducing the committee size, all possible combinations of reviewers for each possible committee size were modeled. To determine the effect of reducing the number of abstracts each member reviewed, we used Monte Carlo simulation with 100 cycles to generate possible combinations of 1-9 reviewers for each abstract. Mean percent agreement with the actual selection was the primary outcome. RESULTS:The mean percent agreement progressively declined from 90.2% with 1 less committee member to 56.7% with only a single reviewer. For each reduction in the number of committee members, 4.4% agreement was lost. If all committee members were retained but the number of reviewers per abstract was reduced from 8 to 1, the mean percent agreement declined from 88.8% to 43.0%. Each reduction in reviewers per abstract reduced the mean percent agreement 6.3%. CONCLUSION:The findings inform program committees striving to balance the trade-off between an acceptable reduction in agreement, given a reduction in the program committee size or the proportion of abstracts each committee member evaluates.

journal_name

J Orthop Trauma

authors

OʼHara NN,Slobogean GP,Zhan M,Gardner MJ,McKee MD,Moore SM,Higgins TF,OʼToole RV,Orthopaedic Trauma Association Program Committee.

doi

10.1097/BOT.0000000000001108

subject

Has Abstract

pub_date

2018-05-01 00:00:00

pages

e176-e180

issue

5

eissn

0890-5339

issn

1531-2291

journal_volume

32

pub_type

杂志文章
  • Articulating external fixation to overcome nerve gaps in lower extremity trauma.

    abstract::This report describes the use of articulating external fixation in patients with lower extremity trauma with segmental nerve defects. Four patients who would otherwise require nerve grafting underwent application of an articulated external fixator, allowing optimal positioning for end-to-end, tension-free nerve repair...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200304000-00008

    authors: Ruch DS,Smith AM

    更新日期:2003-04-01 00:00:00

  • Open reduction and plate fixation of displaced AO type C3 fractures of the distal radius: restoration of articular congruity in eighteen cases.

    abstract:OBJECTIVE:To determine the ability of open reduction and plate fixation to restore articular congruity in the treatment of fractures of the distal radius with intraarticular comminution and displacement. DESIGN:Prospectively followed series. METHODS:Eighteen consecutive fractures of the distal radius with intraarticu...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200106000-00008

    authors: Schneeberger AG,Ip WY,Poon TL,Chow SP

    更新日期:2001-06-01 00:00:00

  • Economic value of orthopaedic trauma: the (second to) bottom line.

    abstract:OBJECTIVES:We evaluated the economic aspects of an orthopaedic trauma section at a regional Level I, semi-academic community hospital. This study analyzes the economics of a dedicated hospital-based orthopaedic trauma program. METHODS:Institutional financial reports were analyzed for 2 time periods. In the pre-program...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31816bae67

    authors: Ziran BH,Barrette-Grischow MK,Marucci K

    更新日期:2008-04-01 00:00:00

  • Internal fixation with a self-compressing plate and lag screw: improvements of the plate hole and screw design. 2. In vivo investigations.

    abstract::A mechanically improved design of bone plate and screw was compared in vivo with conventional plate fixation. This method was investigated biologically in a standardized osteotomy model on sheep tibiae. It was found that maintenance of reduction of an osteotomy was facilitated and there was no adverse effect of this f...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199109000-00006

    authors: Klaue K,Kowalski M,Perren SM

    更新日期:1991-01-01 00:00:00

  • Computed tomography scan to detect traumatic arthrotomies and identify periarticular wounds not requiring surgical intervention: an improvement over the saline load test.

    abstract:OBJECTIVE:To report our experience with computed tomography (CT) scans to detect traumatic arthrotomies of the knee (TAK) joint based on the presence of intra-articular air. DESIGN:Retrospective review. SETTING:Level I trauma center. PATIENTS:Sixty-two consecutive patients (63 knees) underwent a CT scan of the knee ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31828219bc

    authors: Konda SR,Davidovitch RI,Egol KA

    更新日期:2013-09-01 00:00:00

  • Efficacy of bone staples for fixation.

    abstract::The pull-out strength of two types of bone staples (A, Techmedica; B, Richards) was evaluated in a canine model and compared with a control of 6.5 mm cancellous bone screw (Synthes). Fifteen adult mongrel dogs were divided into three groups of five animals each. The implants were placed in the lateral femoral condyle ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-198701040-00009

    authors: Bargar WL,Sharkey NA,Paul HA,Manske DJ

    更新日期:1987-01-01 00:00:00

  • Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.

    abstract:OBJECTIVES:To introduce a modified operative technique for minimally invasive plate osteosynthesis (MIPO) for acute displaced humeral shaft fractures and to evaluate the clinical and radiological outcomes. DESIGN:: Prospective clinical series study. SETTING:University hospital. PATIENTS:Twenty-one patients with acut...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318254895f

    authors: Shin SJ,Sohn HS,Do NH

    更新日期:2012-10-01 00:00:00

  • The combined olecranon osteotomy, lateral paratricipital sparing, deltoid insertion splitting approach for concomitant distal intra-articular and humeral shaft fractures.

    abstract::Fractures of the distal humerus involving the articular surface can be challenging. The complexity of these fracture patterns increases when the distal fracture is associated with a concomitant humeral shaft fracture with significant proximal extension. The combined exposure technique described here allows for consist...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000245988.23684.79

    authors: Lewicky YM,Sheppard JE,Ruth JT

    更新日期:2007-02-01 00:00:00

  • Treatment of diaphyseal fractures of the humerus using a functional brace.

    abstract:OBJECTIVE:To determine humeral diaphyseal fractures at risk for nonunion with functional brace treatment. DESIGN:Retrospective case series. SETTING:A single surgeon's practice. PATIENTS:Forty-nine of 52 consecutive patients treated nonoperatively for an isolated diaphyseal fracture of the humerus during a 6-year per...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000249423.48074.82

    authors: Rutgers M,Ring D

    更新日期:2006-10-01 00:00:00

  • Intraarticular calcaneus fractures: a biomechanical comparison or two fixation methods.

    abstract:OBJECTIVE:To compare the strength of fixation obtained using two unicortical 4.0 mm diameter cancellous screws versus two bicortical 3.5 mm diameter cortical screws in the fixation of intra-articular calcaneus fractures. DESIGN:In eight paired fresh frozen cadaver feet, the subtalar joint complex, consisting of the ta...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199701000-00008

    authors: Bailey EJ,Waggoner SM,Albert MJ,Hutton WC

    更新日期:1997-01-01 00:00:00

  • The reinforcement of cancellous bone screws with calcium phosphate cement.

    abstract::The ability of calcium phosphate cement (CPC) to reinforce cancellous screws placed in previously stripped holes was studied in vitro. The distal end of canine femurs were harvested. A total of 15 screws were placed in six femurs. The pullout strength (failure force), failure displacement, stiffness, and energy absorb...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199601000-00003

    authors: Mermelstein LE,Chow LC,Friedman C,Crisco JJ 3rd

    更新日期:1996-01-01 00:00:00

  • Operative fixation of acetabular fractures in the pregnant patient.

    abstract:OBJECTIVE:To describe in utero radiation exposures in pregnant patients undergoing acetabular fracture repair. DESIGN:Retrospective case series. SETTING:University-affiliated regional trauma center. PATIENT/PARTICIPANTS:Eight pregnant patients with acetabular fractures treated over a 6-year period. There were an add...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181847a42

    authors: Porter SE,Russell GV,Qin Z,Graves ML

    更新日期:2008-09-01 00:00:00

  • Surgical Site Infections in Patients With Type 3 Open Fractures: Comparing Antibiotic Prophylaxis With Cefazolin Plus Gentamicin Versus Piperacillin/Tazobactam.

    abstract:OBJECTIVES:The purpose of this study was to compare rates of surgical site infection (SSI) in patients with type 3 open fractures who had received cefazolin plus gentamicin versus piperacillin/tazobactam for antibiotic prophylaxis. DESIGN:Retrospective cohort study. SETTING:Level 1 trauma center. PATIENTS:Seven hund...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000554

    authors: Redfern J,Wasilko SM,Groth ME,McMillian WD,Bartlett CS 3rd

    更新日期:2016-08-01 00:00:00

  • Anterior tension band plating for anterior tibial stress fractures in high-performance female athletes: a report of 4 cases.

    abstract::Stress fracture of the anterior tibial cortex is an extremely challenging fracture to treat, especially in the high-performance female athlete who requires rapid return to competition. Previous reports have not addressed treating these fractures in the world-class athlete with anterior plating. We hypothesize that ant...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200607000-00011

    authors: Borens O,Sen MK,Huang RC,Richmond J,Kloen P,Jupiter JB,Helfet DL

    更新日期:2006-07-01 00:00:00

  • Results of indirect reduction and plating of femoral shaft nonunions after intramedullary nailing.

    abstract:OBJECTIVE:To observe and report the clinical results of indirect plating techniques in the treatment of femoral shaft nonunions originally treated with intramedullary nailing. DESIGN:Prospective consecutive. SETTING:Regional trauma center. PATIENTS:A consecutive series of twenty-three patients with nonunion of femor...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200105000-00004

    authors: Bellabarba C,Ricci WM,Bolhofner BR

    更新日期:2001-05-01 00:00:00

  • Rotational imaging of complex acetabular fractures.

    abstract::Understanding complex acetabular fractures is difficult and may require three-dimensional reformatted computed tomographic (CT) images. This paper evaluates a technique, digital rotational imaging (DRI), that displays multiple oblique images of the pelvis and acetabulum. When viewed statically, DRI provides optimal il...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199801000-00011

    authors: Patel NH,Hunter J,Weber TG,Routt ML Jr

    更新日期:1998-01-01 00:00:00

  • Importance of Mechanoreceptors and Other Neural Structures Within the Anterior Intermeniscal Ligament in the Etiology of Anterior Knee Pain After Tibial Nailing.

    abstract:BACKGROUND:Anterior knee pain is the most common complication after intramedullary tibial nailing. The cause is often multifactorial and varies among individuals. Violation of the anterior intermeniscal ligament (AIL) during intramedullary tibial nailing might be a possible source of postsurgical anterior knee pain. Al...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001258

    authors: Franke J,Brobeil A,Lips KS,Gattenloehner S,Franke AP,Hohendorff B,Alt V,Schnettler R

    更新日期:2018-10-01 00:00:00

  • Biomechanical evaluation of methods of internal fixation of the distal humerus.

    abstract::The best results following fractures of the distal humerus are provided by anatomic reduction and rigid internal fixation. Plates of two designs placed in five different fixation configurations were used to determine the construct that would maximize rigidity of fixation of the distal humerus. Using a cadaver distal h...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Schemitsch EH,Tencer AF,Henley MB

    更新日期:1994-12-01 00:00:00

  • Scaphocapitate syndrome in a child associated with a distal radius and ulna fracture.

    abstract::A case is presented of scaphocapitate fracture syndrome associated with a Salter-Harris type II fracture of the distal radius and ulna occurring in an 11-year-old girl. The proximal fragment of the fractured capitate was rotated 180 degrees. The injury was treated by open reduction and internal fixation. One year afte...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199704000-00017

    authors: Mazur K,Stevanovic M,Schnall SB,Hannani K,Zionts LE

    更新日期:1997-04-01 00:00:00

  • A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates.

    abstract:OBJECTIVES:To examine the biomechanical behavior of 2 techniques of double-plate osteosynthesis for fractures of the adult distal humerus using conventional reconstruction plates and locking compression plates. DESIGN:Basic science study. SETTING:Experimental in vitro study. PATIENTS/PARTICIPANTS:Forty fresh-frozen ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200405000-00004

    authors: Korner J,Diederichs G,Arzdorf M,Lill H,Josten C,Schneider E,Linke B

    更新日期:2004-05-01 00:00:00

  • Harvesting of autogenous cancellous bone graft from the proximal tibial metaphysis. A review of 230 cases.

    abstract::A study was undertaken to review the results of donor site morbidity of cancellous bone grafts obtained from the proximal tibial metaphysis. Two hundred six patients who underwent 230 proximal tibial bone graft harvestings were reviewed. Patients with lower-extremity fractures or nonunions who required cancellous bone...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199112000-00014

    authors: O'Keeffe RM Jr,Riemer BL,Butterfield SL

    更新日期:1991-01-01 00:00:00

  • Efficacy of popliteal block in postoperative pain control after ankle fracture fixation: a prospective randomized study.

    abstract:OBJECTIVES:To compare postoperative pain control in patients treated surgically for ankle fractures who receive popliteal blocks with those who received general anesthesia alone. DESIGN:Institutional Review Board approved prospective randomized study. SETTING:Metropolitan tertiary-care referral center. PATIENTS:All ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/BOT.0b013e3182638b25

    authors: Goldstein RY,Montero N,Jain SK,Egol KA,Tejwani NC

    更新日期:2012-10-01 00:00:00

  • Management of humeral nonunion after the failure of locking intramedullary nails.

    abstract::We reviewed 21 cases of humeral nonunion following the failure of "locking" humeral nails. The nails had been inserted as the primary operative procedure following humeral fracture in fifteen cases or after the failure of closed treatment in six cases. Reconstruction after the failure of these implants was complicated...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199610000-00008

    authors: McKee MD,Miranda MA,Riemer BL,Blasier RB,Redmond BJ,Sims SH,Waddell JP,Jupiter JB

    更新日期:1996-01-01 00:00:00

  • Ninety-Five Degree Angled Blade Plate Fixation of High-Energy Unstable Proximal Femur Fractures Results in High Rates of Union and Minimal Complications.

    abstract:OBJECTIVES:To describe the surgical technique and clinical outcomes of high-energy proximal femur fractures treated with a 95-degree angled blade plate. DESIGN:Retrospective case series. SETTING:Single academic Level I trauma center. PATIENT/PARTICIPANTS:Forty-five consecutive patients from March 2012 to April 2017 ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001505

    authors: Berkes MB,Schottel PC,Weldon M,Hansen DH,Achor TS

    更新日期:2019-07-01 00:00:00

  • Lengthening of the femur over an existing intramedullary nail.

    abstract::Leg length discrepancies can occur despite successful union of femur fractures after intramedullary nailing (IMN). Often, the leg length discrepancy can result in significant disability to the patient, altered gait biomechanics, pelvic obliquity, and pain. Therefore, a successful clinical result for such deformities a...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181f92d6e

    authors: Kim HJ,Fragomen AT,Reinhardt K,Hutson JJ Jr,Rozbruch SR

    更新日期:2011-11-01 00:00:00

  • The Community Orthopaedic Surgeon Taking Trauma Call: Pediatric Femoral Shaft Fracture Pearls and Pitfalls.

    abstract::Pediatric femoral shaft fractures present many challenging patient care decisions. Nonoperative treatment approaches still dominate care of the youngest age groups while surgical intervention is commonplace in virtually all older children. Treatment is determined primarily by patient age as modified by clinical factor...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001016

    authors: Gordon JE,Mehlman CT

    更新日期:2017-11-01 00:00:00

  • Treatment of displaced, proximal, humeral, epiphyseal fractures with a two-prong splint.

    abstract::To evaluate the use of a two-prong splint for displaced, proximal, humerus, epiphyseal fractures, seven children with Neer-Horwitz Classification Type 3-4 fractures of the proximal humerus were retrospectively investigated. After closed reduction, fracture stabilization was accomplished with the use of a two-prong spl...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200309000-00007

    authors: Karatosun V,Unver B,Alici E,Serin E

    更新日期:2003-09-01 00:00:00

  • Quantification of the upper and second sacral segment safe zones in normal and dysmorphic sacra.

    abstract:OBJECTIVES:To quantify the obliquity and dimensions of the upper and second sacral segment iliosacral screw safe zones and to determine the differences between normal and dysmorphic sacral morphology. DESIGN:Retrospective cohort. SETTING:University Level I trauma center. PATIENTS/PARTICIPANTS:Fifty patients with pel...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181cf0404

    authors: Gardner MJ,Morshed S,Nork SE,Ricci WM,Chip Routt ML Jr

    更新日期:2010-10-01 00:00:00

  • Intraoperative fluoroscopy to evaluate fracture reduction and hardware placement during acetabular surgery.

    abstract:OBJECTIVES:To evaluate use of intraoperative fluoroscopy during acetabular surgery to determine fracture reduction and accurate placement of screws. DESIGN:Retrospective. SETTING:Level I trauma center. PARTICIPANTS:Thirty patients with thirty-two acetabular fractures. INTERVENTION:Patients were evaluated with fluor...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199908000-00004

    authors: Norris BL,Hahn DH,Bosse MJ,Kellam JF,Sims SH

    更新日期:1999-08-01 00:00:00

  • Extensile Fasciotomy for Compartment Syndrome of the Forearm and Hand.

    abstract:PURPOSE:The purpose of this video is to demonstrate the technique of an extensile fasciotomy of the forearm and hand. METHODS:A patient presented to our hospital with a rapidly progressing infection of the right upper extremity and clinical signs and symptoms of compartment syndrome. The patient was immediately taken ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000903

    authors: Turkula SC,Fuller DA

    更新日期:2017-08-01 00:00:00