Abstract:
:Minifragment implants provide several advantages for the stabilization of distal humerus fractures. Compared with small fragment implants, minifragment implants may provide enhanced fracture fixation because a greater number of screws can be placed into the distal fragments. In addition, minifragment plates are easier to contour and less prominent. We describe the surgical technique of minifragment fixation.
journal_name
J Orthop Traumajournal_title
Journal of orthopaedic traumaauthors
Russell GV Jr,Jarrett CA,Jones CB,Cole PA,Gates Jdoi
10.1097/01.bot.0000157908.45939.d7subject
Has Abstractpub_date
2005-08-01 00:00:00pages
474-9issue
7eissn
0890-5339issn
1531-2291pii
00005131-200508000-00008journal_volume
19pub_type
杂志文章abstract::The ability of calcium phosphate cement (CPC) to reinforce cancellous screws placed in previously stripped holes was studied in vitro. The distal end of canine femurs were harvested. A total of 15 screws were placed in six femurs. The pullout strength (failure force), failure displacement, stiffness, and energy absorb...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199601000-00003
更新日期:1996-01-01 00:00:00
abstract::The conventional qualitative techniques of manual manipulation and plain radiography do not give a quantifiable measurement of healing. With internal fixation, manual manipulation is not usually possible, and conventional radiographs may not give much useful information, particularly if only a small amount of callus i...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199611000-00010
更新日期:1996-01-01 00:00:00
abstract::We present a rare case of complete talar extrusion after trauma. Treatment of this severe injury remains controversial as a result of the lack of congruent evidence-based literature, associated high complication rate with primary repair, and difficulty in objectively assessing long-term outcomes. Recent small sampled ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318210f236
更新日期:2011-11-01 00:00:00
abstract:OBJECTIVES:To determine whether uncemented implants would provide similar outcomes while avoiding the complications associated with cement in the treatment of elderly patients with proximal humerus fractures (PHFs) with primary reverse total shoulder arthroplasty (RTSA). DESIGN:Case series. SETTING:A single Level I t...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001465
更新日期:2019-07-01 00:00:00
abstract:OBJECTIVE:To determine the prognostic reliability, sensitivity, and specificity of the Hawkins sign. The Hawkins sign is a subchondral radiolucent band in the talar dome that is indicative of viability at 6 to 8 weeks after a talus fracture. It is visible in the anterior-posterior view, but seldom appears on lateral ra...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318148c665
更新日期:2007-09-01 00:00:00
abstract:OBJECTIVE:Syndesmotic instability may coexist with unstable Weber B supination-external rotation (SE) lateral malleolar fractures. Current recommendations suggest that Weber B injuries should not have associated syndesmotic instability after open reduction and internal fixation of the lateral malleolus. The purpose of ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318157a63a
更新日期:2007-10-01 00:00:00
abstract::Autologous bone graft is usually necessary for reconstruction of nonunions with shortening or bone loss. We developed a new technique to reconstruct such nonunions or delayed unions without bone grafting by chipping and lengthening of bone at the original fracture site. Five in six nonunions with shortening or bone lo...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318041f6d1
更新日期:2007-07-01 00:00:00
abstract::Salvage of limb length following oblique proximal foot amputations is presented. The technique, results, and follow-up of this procedure are described and compared with other standard procedures. A prospective study was done on 3 adolescents who presented consecutively during years 1999 and 2000. The salvage procedure...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/01.bot.0000164168.94365.49
更新日期:2005-04-01 00:00:00
abstract::Periprosthetic humerus fractures are relatively uncommon occurrence that can be difficult to manage nonoperatively. Locking plate technology has enhanced the surgical management of these fractures. However, adequate fixation around the stem remains of some concern. We describe an osteosynthesis technique using a locki...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000646
更新日期:2016-11-01 00:00:00
abstract:OBJECTIVES:We developed a protocol to determine the timing of definitive fracture care based on the adequacy of resuscitation. Inception of this project required a multidisciplinary group, including physicians from anesthesiology, general trauma and critical care, neurosurgery, orthopaedic spine, and orthopaedic trauma...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000383
更新日期:2015-11-01 00:00:00
abstract::The extraosseous tissue contribution to diaphyseal fracture callus has been investigated using a rabbit tibial fracture model and osteocalcin immunocytochemistry. The extraosseous tissues were isolated for study by reaming and nailing an osteotomy and excising 2 cm of periosteum on either side of the osteotomy. Specim...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199206000-00010
更新日期:1992-01-01 00:00:00
abstract::Twenty-six patients with major anterior-posterior pelvic disruptions not involving the acetabulum were reevaluated an average of 8 years (minimum 5 years) after injury. All pelvic injuries were treated nonoperatively. Subjective complaints at the time of follow-up included frequent or daily low back discomfort (50%), ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-198903010-00008
更新日期:1989-01-01 00:00:00
abstract:OBJECTIVES:To relate the incidence of implant failure after internal anterior fixation of the pelvic ring to functional outcome and the health-related quality of life in patients. DESIGN:Retrospective chart and radiographic review. SETTING:Level I Trauma center. METHODS:We retrospectively identified all patients who...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000501
更新日期:2016-06-01 00:00:00
abstract::Leg length discrepancies can occur despite successful union of femur fractures after intramedullary nailing (IMN). Often, the leg length discrepancy can result in significant disability to the patient, altered gait biomechanics, pelvic obliquity, and pain. Therefore, a successful clinical result for such deformities a...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181f92d6e
更新日期:2011-11-01 00:00:00
abstract:OBJECTIVES:To report the complications and pitfalls in the treatment of complex injuries of the proximal tibia when locking plates are used. DESIGN, SETTING, AND PATIENTS:This was a retrospective case series conducted at a university Level I trauma center. Thirty-seven patients with complex proximal tibia fractures (4...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318030df96
更新日期:2007-02-01 00:00:00
abstract::After completing an orthopaedic trauma fellowship, what challenges will you have as regard to maintaining balance and perspective in your new position in society? How will you view yourself, family, and your profession? These are simple suggestions on maintaining passion for your profession. ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000000431
更新日期:2015-11-01 00:00:00
abstract:OBJECTIVE:To compare the mechanical stability of fixation of an unstable bicondylar tibial plateau fracture with several different fixation techniques in a cadaveric model. DESIGN:Randomized laboratory investigation using a simulated bicondylar tibial plateau fracture with metaphyseal-diaphyseal dissociation. SETTING...
journal_title:Journal of orthopaedic trauma
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00005131-199911000-00005
更新日期:1999-11-01 00:00:00
abstract::The difficulty in assessing femoral rotation during intramedullary nailing is well-established. Navigation systems allow the surgeon to detect and set the version of the injured leg at the desired angle. We report the first cases of navigated femoral nailing using noninvasive registration of the contralateral uninjure...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31812f69a9
更新日期:2007-11-01 00:00:00
abstract::The standard AO-plate was used as an external fixator in 31 patients with an infected nonunion or open fracture mainly of the upper extremity. With the use of this technique, good stability can be achieved with an inexpensive and relatively simple construction. The low profile of the frame is an advantage for the pati...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200301000-00010
更新日期:2003-01-01 00:00:00
abstract:OBJECTIVE:To observe the results and describe the technique of closed reduction and placement of a two-pin supra-acetabular external fixator, followed by immediate weight bearing, in the treatment of displaced vertically stable lateral compression pelvic fractures. DESIGN:Prospective, consecutive. SETTING:Regional tr...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:
更新日期:2006-01-01 00:00:00
abstract:OBJECTIVES:To describe the technique and to determine the outcome of operatively treated displaced scapular body or glenoid neck fractures using minifragment fixation through a modified Judet approach. DESIGN:Retrospective review of scapular or glenoid fractures. SETTING:Level 1 teaching trauma center. PATIENTS:All ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181a18216
更新日期:2009-09-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to examine the efficacy of a fluoroscopically guided hip capsulotomy. METHODS:Ten fresh-frozen paired cadaveric hips were injected under fluoroscopic guidance with saline sufficient to generate an intra-articular pressure greater than 58 mmHg. The pressure was monitored continuo...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181e93cbe
更新日期:2011-04-01 00:00:00
abstract:OBJECTIVE:To determine whether an injectable thrombin product [thrombin hemostatic matrix (THM)] at closure of a Kocher-Langenbeck approach reduces the risk of heterotopic ossification (HO) formation after an acetabular fracture. DESIGN:Case control. SETTING:Two Level 1 trauma centers. PATIENTS:Patients with operati...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001783
更新日期:2020-09-01 00:00:00
abstract::Many of the current techniques of internal fixation of proximal humerus fractures use tension band wires to achieve secure fixation, allowing immediate postoperative exercise of the affected limb. In addition, the use of a cancellous lag screw placed from the humeral shaft into the humeral head may have several advant...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199402000-00006
更新日期:1994-01-01 00:00:00
abstract::Seat belt legislation has resulted in increased restraint use by passengers in automobiles in Washington State. At Harborview Medical Center in Seattle, we have observed an increased incidence of seat belt-related injuries. Twenty cases of Chance-type thoracolumbar flexion-distraction fractures were reviewed retrospec...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199105020-00006
更新日期:1991-01-01 00:00:00
abstract:PURPOSE:Comminuted iliac fractures are uncommon and difficult to treat. The purpose of this study is to further delineate the fractures, to present a management protocol, and to evaluate the results of treatment. DESIGN:Retrospective clinical study. SETTING:Level one trauma center at Harborview Medical Center. PATIE...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200005000-00008
更新日期:2000-05-01 00:00:00
abstract:OBJECTIVE:To determine the relative amount of fixation of self-reinforced poly-L-lactide (SR-PLLA) rods and Kirschner wires in bovine cancellous bone by comparing their pullout strength DESIGN:An in vitro laboratory study was performed using bovine femurs. Ten two-millimeter-diameter pins of each type were inserted in...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200108000-00008
更新日期:2001-08-01 00:00:00
abstract:OBJECTIVES:To compare failure rates between short and long cephalomedullary nails used for the treatment of intertrochanteric hip fractures in patients over 65 years of age. DESIGN:Retrospective cohort study. Data were collected from medical records and radiographs. SETTING:Three level 1 trauma centers. PATIENTS/PAR...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000036
更新日期:2014-07-01 00:00:00
abstract:OBJECTIVES:We evaluated the economic aspects of an orthopaedic trauma section at a regional Level I, semi-academic community hospital. This study analyzes the economics of a dedicated hospital-based orthopaedic trauma program. METHODS:Institutional financial reports were analyzed for 2 time periods. In the pre-program...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31816bae67
更新日期:2008-04-01 00:00:00
abstract::Understanding complex acetabular fractures is difficult and may require three-dimensional reformatted computed tomographic (CT) images. This paper evaluates a technique, digital rotational imaging (DRI), that displays multiple oblique images of the pelvis and acetabulum. When viewed statically, DRI provides optimal il...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199801000-00011
更新日期:1998-01-01 00:00:00