Retrograde Femoral Nailing Using Percutaneous Reduction Techniques.

Abstract:

:Femoral shaft fractures are commonly treated with closed reduction and reamed intramedullary nailing. However, some reductions are difficult to obtain or maintain, especially in muscular or large patients. When closed methods fail to achieve reduction, percutaneous techniques are extremely useful. In addition, the use of either permanent or temporarily placed blocking implants offer a minimally invasive option for improving sagittal and coronal plane alignment. In the accompanying video, we describe our method of percutaneous reduction techniques in the setting of a comminuted femoral shaft fracture treated with a retrograde femoral intramedullary nail.

journal_name

J Orthop Trauma

authors

Pettett BJ,Avery MC,Ostrum RF

doi

10.1097/BOT.0000000000000890

subject

Has Abstract

pub_date

2017-08-01 00:00:00

pages

S6-S7

eissn

0890-5339

issn

1531-2291

pii

00005131-201708003-00004

journal_volume

31 Suppl 3

pub_type

杂志文章
  • Knee pain correlates with union after tibial nailing.

    abstract:OBJECTIVES:The purpose of this study is to evaluate the change in quantitatively scored knee pain during union. DESIGN:This is a retrospective review of prospectively collected data over a 15-year period. SETTING:Academic medical center. PATIENTS:All patients treated with an intramedullary nail were evaluated for kn...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318213f587

    authors: Ryan SP,Tornetta P 3rd,Dielwart C,Kaye-Krall E

    更新日期:2011-12-01 00:00:00

  • Non-invasive low-intensity pulsed ultrasound accelerates bone healing in the rabbit.

    abstract::The effect of ultrasound (US) on the rate of fibula osteotomy healing in 139 mature New Zealand white rabbits was assessed in this study. Bilateral midshaft fibular osteotomies were made using a 1-mm Gigli saw. US was noninvasively applied to one limb for 20 minutes daily, while the contralateral limb served as a cont...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199004030-00002

    authors: Pilla AA,Mont MA,Nasser PR,Khan SA,Figueiredo M,Kaufman JJ,Siffert RS

    更新日期:1990-01-01 00:00:00

  • Locking plates for distal femur fractures: is there a problem with fracture healing?

    abstract:OBJECTIVES:Fractures of the distal femur are severe injuries that present many clinical challenges. Nonunion, delayed union, implant failure, and the need for secondary procedures can reflect complications of healing. This article reviews the literature on distal femur fractures treated with locking plates to determine...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e3182070127

    authors: Henderson CE,Kuhl LL,Fitzpatrick DC,Marsh JL

    更新日期:2011-02-01 00:00:00

  • Recombinant human bone morphogenic protein-7: applications for clinical trauma.

    abstract::Several clinical trials have examined the safety and efficacy of recombinant human bone morphogenic protein-7 (rhBMP-7) for osseous repair in clinical trauma. This article summarizes the results obtained from three recent clinical trials, which suggest that rhBMP-7 is useful in the treatment of tibial nonunion, long b...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200511101-00008

    authors: McKee MD

    更新日期:2005-11-01 00:00:00

  • The biomechanical effect of high-pressure irrigation on diaphyseal fracture healing in vivo.

    abstract:OBJECTIVES:To evaluate the effect of both high-pressure pulsatile lavage and bulb syringe irrigation on the biomechanical parameters of fracture healing using an in vivo open noncontaminated diaphyseal femoral fracture model in rats. BACKGROUND:The utility of high-pressure pulsatile lavage irrigation on soft tissue de...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200207000-00008

    authors: Adili A,Bhandari M,Schemitsch EH

    更新日期:2002-07-01 00:00:00

  • The use of a biodegradable, load-bearing scaffold as a carrier for antibiotics in an infected open fracture model.

    abstract:OBJECTIVES:Open fractures with bone loss are common, disabling injuries. Biodegradable, load-bearing scaffolds able to carry high concentrations of local antibiotics are an emerging technology to address these injuries. This study investigates the use of such scaffolds with gentamicin (along with bone morphogenetic pro...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181ed1349

    authors: Stewart RL,Cox JT,Volgas D,Stannard J,Duffy L,Waites KB,Chu TM

    更新日期:2010-09-01 00:00:00

  • Intramedullary nailing of tibial shaft fractures distal to total knee arthroplasty.

    abstract::Tibial shaft fractures distal to total knee arthroplasty are rare, but they are likely to become more common with the increasing number of arthroplasty procedures being performed. These fracture patterns have been treated in the past either with closed reduction and casting/bracing or with open reduction internal fixa...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000096

    authors: Haller JM,Kubiak EN,Spiguel A,Gardner MJ,Horwitz DS

    更新日期:2014-12-01 00:00:00

  • Abductor Muscle Function and Trochanteric Tenderness After Hemiarthroplasty for Femoral Neck Fracture.

    abstract:OBJECTIVES:To compare the abductor muscle function and trochanteric tenderness in patients operated with hemiarthroplasty using the direct lateral (DL) or posterolateral (PL) approach for displaced femoral neck fracture. DESIGN:Prospective cohort study. SETTING:A secondary teaching hospital. PARTICIPANTS:We enrolled...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000532

    authors: Sayed-Noor AS,Hanas A,Sköldenberg OG,Mukka SS

    更新日期:2016-06-01 00:00:00

  • The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures.

    abstract:OBJECTIVES:The purpose of this study was to evaluate forearm rotation after volar plating of the distal radius fractures with and without pronator quadratus repair. DESIGN:This was an institutional review board-approved retrospective review of prospectively collected data. SETTING:The study was conducted at an Academ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182539333

    authors: Hershman SH,Immerman I,Bechtel C,Lekic N,Paksima N,Egol KA

    更新日期:2013-03-01 00:00:00

  • Incision placement for intramedullary tibial nailing: an anatomic study.

    abstract:OBJECTIVES:For intramedullary nailing of tibial shaft fractures, a recent study has determined that the entry site should be just medial to the lateral tibial spine at the anterior margin of the articular surface. Gaining access to this site is often through a medial parapatellar or transpatellar approach. Several stud...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200211000-00001

    authors: Althausen PL,Neiman R,Finkemeier CG,Olson SA

    更新日期:2002-11-01 00:00:00

  • Knee Disarticulations Versus Transfemoral Amputations: Functional Outcomes.

    abstract:OBJECTIVES:To determine whether there is a patient-reported functional difference between combat-related knee disarticulations (KDs) and transfemoral amputations (TFAs). SETTING:Role 3 Military Trauma Centers. PATIENTS:We identified and contacted all KDs and TFAs performed at the Walter Reed National Military Medical...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001440

    authors: Polfer EM,Hoyt BW,Bevevino AJ,Forsberg JA,Potter BK

    更新日期:2019-06-01 00:00:00

  • Orthopaedic Trauma in the Developing World: Where Are the Gaps in Research and What Can Be Done?

    abstract:PURPOSE:There are an estimated 1.2 million deaths from road traffic injuries annually, disproportionately affecting patients in low-resource settings. The purpose of this scoping review is to identify knowledge gaps in global orthopaedic trauma in an effort to help prioritize future research. METHODS:Using the 6-stage...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000001293

    authors: Challa S,Wu HH,Cunningham BP,Liu M,Patel K,Shearer DW,Morshed S,Miclau T

    更新日期:2018-10-01 00:00:00

  • Trauma program development.

    abstract::The development of a strong trauma program is clearly one of the most important facets of successful business development. Several recent publications have demonstrated that well run trauma services can generate significant profits for both the hospital and the surgeons involved. There are many aspects to this task th...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000142

    authors: Althausen PL

    更新日期:2014-07-01 00:00:00

  • Quality of Reduction of Displaced Intra-Articular Calcaneal Fractures Using a Sinus Tarsi versus Extensile Lateral Approach.

    abstract:OBJECTIVE:To evaluate the difference in quality of fracture reduction between the sinus tarsi approach (STA) and extensile lateral approach (ELA) using postoperative CT scans in displaced intra-articular calcaneal fractures (DIACFs). DESIGN:Retrospective SETTING:: Level 1 and Level 2 academic centers. PATIENTS:Consec...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001971

    authors: Busel G,Mir HR,Merimee S,Patel R,Atassi O,De La Fuente G,Donohue D,Maxson B,Infante A,Shah A,Watson D,Downes K,Sanders RW

    更新日期:2020-09-18 00:00:00

  • Dual-purpose bone grafts improve healing and reduce infection.

    abstract:OBJECTIVE:To determine if a dual-purpose bone graft can regenerate bone and reduce infection in highly contaminated bone critical size defects in rats. METHODS:Biodegradable polyurethane (PUR) scaffolds were loaded with recombinant human bone morphogenetic protein-2 (BMP-2) and vancomycin (Vanc). The release kinetics ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31821f624c

    authors: Guelcher SA,Brown KV,Li B,Guda T,Lee BH,Wenke JC

    更新日期:2011-08-01 00:00:00

  • Does malrotation following MIPO treatment of distal tibia metaphyseal fractures effect the functional results of the ankle and knee joints?

    abstract:OBJECTIVES:To investigate whether rotational malalignment of tibia, after fracture management with minimally invasive plate osteosynthesis technique (MIPO), leads to impaired results in knee and ankle joint functional scores. DESIGN:Prospectively collected data was retrospectively analyzed for this study. SETTING:Lev...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000002053

    authors: Çepni Ş,Yaman F,Veizi E,Fırat A,ÇayAssoc N,Tecimel O

    更新日期:2020-12-31 00:00:00

  • Vascular abnormalities as assessed with CT angiography in high-energy tibial plafond fractures.

    abstract:OBJECTIVE:The purpose of this study was to examine the results of computed tomography angiography (CTA) obtained in patients with high-energy tibial plafond fractures and assess if the information gleaned from CTA could be useful to the treating orthopedic surgeon. DESIGN:Consecutive patient series. SETTING:Level 2 t...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31815cf6e9

    authors: LeBus GF,Collinge C

    更新日期:2008-01-01 00:00:00

  • Irreducible fracture dislocation of the knee.

    abstract::A unique case of an irreducible fracture dislocation of the knee is reported. A review of the literature revealed no previously reported cases of fracture dislocation of the distal femur not amenable to closed reduction. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/00005131-199607000-00013

    authors: Pugh KJ,Wilber JH

    更新日期:1996-01-01 00:00:00

  • The reinforcement of cancellous bone screws with calcium phosphate cement.

    abstract::The ability of calcium phosphate cement (CPC) to reinforce cancellous screws placed in previously stripped holes was studied in vitro. The distal end of canine femurs were harvested. A total of 15 screws were placed in six femurs. The pullout strength (failure force), failure displacement, stiffness, and energy absorb...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199601000-00003

    authors: Mermelstein LE,Chow LC,Friedman C,Crisco JJ 3rd

    更新日期:1996-01-01 00:00:00

  • Preoperative Testing for Hip Fracture Patients Delays Surgery, Prolongs Hospital Stays, and Rarely Dictates Care.

    abstract:OBJECTIVES:To determine how often preoperative testing is requested for geriatric hip fracture patients, to assess the extent to which preoperative testing is associated with delayed surgery, and to measure the frequency with which preoperative testing changes patient management. DESIGN:Retrospective. SETTING:Academi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000444

    authors: Bernstein J,Roberts FO,Wiesel BB,Ahn J

    更新日期:2016-02-01 00:00:00

  • Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail.

    abstract:OBJECTIVES:To compare the results between a new intramedullary Gamma nail and a compression hip screw in the treatment of trochanteric fractures. DESIGN:Prospective randomized. SETTING:Level 1 trauma center. PATIENTS:Two hundred ten consecutive patients older than 65 years with trochanteric femoral fractures. INTER...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.bot.0000151819.95075.ad

    authors: Utrilla AL,Reig JS,Muñoz FM,Tufanisco CB

    更新日期:2005-04-01 00:00:00

  • Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate.

    abstract:OBJECTIVES:To document the high failure rate of a specific implant: the Synthes Variable Angle (VA) Locking Distal Femur Plate. DESIGN:Retrospective. SETTING:Urban University Level I Trauma Center. PATIENT/PARTICIPANTS:All distal femur fractures (OTA/AO 33-A, B, C) treated from March 2011 through August 2013 were re...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000391

    authors: Tank JC,Schneider PS,Davis E,Galpin M,Prasarn ML,Choo AM,Munz JW,Achor TS,Kellam JF,Gary JL

    更新日期:2016-01-01 00:00:00

  • Intramedullary nail fracture compression techniques: when and how to do it?

    abstract::Fracture compression can be achieved in many ways intraoperatively using either screws in compression plates, compression devices, or using intramedullary nails. The use of locked intramedullary nails combines the advantages of indirect fracture fixation and compression with minimal soft tissue disruption. This articl...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e31819f2779

    authors: Tejwani NC

    更新日期:2009-05-01 00:00:00

  • Plate fixation of femoral nonunions over an intramedullary nail with autogenous bone grafting.

    abstract:OBJECTIVE:To describe a novel approach for the treatment of nonunions of diaphyseal femur fractures. DESIGN:Retrospective review. SETTING:University hospital. PATIENTS:Seven patients (six men, one woman, average age 42.5 years) with diaphyseal femoral fracture nonunions treated between November 2006 and November 200...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181dfbb33

    authors: Hakeos WM,Richards JE,Obremskey WT

    更新日期:2011-02-01 00:00:00

  • Rotator Cuff-Sparing Approach for Antegrade Humeral Nailing With Biceps Tenodesis: A Technical Trick With Clinical Implications.

    abstract::Antegrade intramedullary nails are an established, effective method of fixation for humeral shaft fractures. One significant limitation of this technique is chronic postoperative shoulder pain, which is likely related to the standard approach that involves splitting the rotator cuff to gain access to the nail starting...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000684

    authors: Christ AB,Gausden EB,Warner SJ,Nellestein AM,Thacher RR,Lorich DG

    更新日期:2017-02-01 00:00:00

  • Biomechanics-Hot Topics Part II.

    abstract::Orthopaedic surgery and biomechanics are intimately partnered topics in medicine. Biomechanical principles are used to design implants and fashion treatment protocols. Although it would seem that biomechanical principles in the design of fixation devices and fracture repair constructs have been already finalized, ther...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000001126

    authors: Finkemeier C,Adams JD,Bernstein M,Lee MA,Harvey E,Crist BD

    更新日期:2018-03-01 00:00:00

  • Modified Technique of Separate Vertical Wiring for the Fixation of Patellar Inferior Pole Fracture.

    abstract::To evaluate the biomechanical and clinical results of modified separate vertical wiring technique (SVW) for inferior pole patellar fracture repair we conducted a finite element biomechanical study using 2 fixation methods and evaluated a clinical series of eleven patients. The modified SVW technique was an effective, ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001080

    authors: He S,Huang X,Yan B,Zhu J,Bao N,Zhao J

    更新日期:2018-04-01 00:00:00

  • Primary total hip arthroplasty with a Burch-Schneider antiprotrusion cage and autologous bone grafting for acetabular fractures in elderly patients.

    abstract:OBJECTIVES:To investigate the clinical and functional outcome in an elderly population with acetabular fractures after low-energy trauma treated acutely with a total hip arthroplasty supported by a reinforcement ring (Burch-Schneider antiprotrusion cage) and autologous bone grafting of the acetabulum. SETTING:Universi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200303000-00007

    authors: Tidermark J,Blomfeldt R,Ponzer S,Söderqvist A,Törnkvist H

    更新日期:2003-03-01 00:00:00

  • Unexpected high complication rate following internal fixation of unstable proximal humerus fractures with an angled blade plate.

    abstract:OBJECTIVES:The increasing number of fractures of the proximal humerus, especially in the elderly, carries with it the unsolved problem of the optimal treatment for the displaced or unstable fractures. The authors' goal was to analyze whether fixation with a bent valgus angled blade plate could improve the outcomes repo...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200604000-00004

    authors: Meier RA,Messmer P,Regazzoni P,Rothfischer W,Gross T

    更新日期:2006-04-01 00:00:00

  • Synovial metallosis resulting from intraarticular intramedullary nailing of a distal femoral nonunion.

    abstract::An 80-year-old man sustained a T-shaped supracondylar fracture of the femur associated with distal one-third shaft comminution. Initial failure of a 95 degrees angle blade plate was followed by insertion of an intraarticular intramedullary nail stabilized with static locking-screw fixation. A second failure of the imp...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199308000-00004

    authors: Johnson EE,Marroquin CE,Kossovsky N

    更新日期:1993-01-01 00:00:00