Abstract:
:Femoral shaft fractures are commonly treated with closed reduction and reamed intramedullary nailing. However, some reductions are difficult to obtain or maintain, especially in muscular or large patients. When closed methods fail to achieve reduction, percutaneous techniques are extremely useful. In addition, the use of either permanent or temporarily placed blocking implants offer a minimally invasive option for improving sagittal and coronal plane alignment. In the accompanying video, we describe our method of percutaneous reduction techniques in the setting of a comminuted femoral shaft fracture treated with a retrograde femoral intramedullary nail.
journal_name
J Orthop Traumajournal_title
Journal of orthopaedic traumaauthors
Pettett BJ,Avery MC,Ostrum RFdoi
10.1097/BOT.0000000000000890subject
Has Abstractpub_date
2017-08-01 00:00:00pages
S6-S7eissn
0890-5339issn
1531-2291pii
00005131-201708003-00004journal_volume
31 Suppl 3pub_type
杂志文章abstract:OBJECTIVES:The purpose of this study is to evaluate the change in quantitatively scored knee pain during union. DESIGN:This is a retrospective review of prospectively collected data over a 15-year period. SETTING:Academic medical center. PATIENTS:All patients treated with an intramedullary nail were evaluated for kn...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318213f587
更新日期:2011-12-01 00:00:00
abstract::The effect of ultrasound (US) on the rate of fibula osteotomy healing in 139 mature New Zealand white rabbits was assessed in this study. Bilateral midshaft fibular osteotomies were made using a 1-mm Gigli saw. US was noninvasively applied to one limb for 20 minutes daily, while the contralateral limb served as a cont...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199004030-00002
更新日期:1990-01-01 00:00:00
abstract:OBJECTIVES:Fractures of the distal femur are severe injuries that present many clinical challenges. Nonunion, delayed union, implant failure, and the need for secondary procedures can reflect complications of healing. This article reviews the literature on distal femur fractures treated with locking plates to determine...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0b013e3182070127
更新日期:2011-02-01 00:00:00
abstract::Several clinical trials have examined the safety and efficacy of recombinant human bone morphogenic protein-7 (rhBMP-7) for osseous repair in clinical trauma. This article summarizes the results obtained from three recent clinical trials, which suggest that rhBMP-7 is useful in the treatment of tibial nonunion, long b...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200511101-00008
更新日期:2005-11-01 00:00:00
abstract:OBJECTIVES:To evaluate the effect of both high-pressure pulsatile lavage and bulb syringe irrigation on the biomechanical parameters of fracture healing using an in vivo open noncontaminated diaphyseal femoral fracture model in rats. BACKGROUND:The utility of high-pressure pulsatile lavage irrigation on soft tissue de...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200207000-00008
更新日期:2002-07-01 00:00:00
abstract:OBJECTIVES:Open fractures with bone loss are common, disabling injuries. Biodegradable, load-bearing scaffolds able to carry high concentrations of local antibiotics are an emerging technology to address these injuries. This study investigates the use of such scaffolds with gentamicin (along with bone morphogenetic pro...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181ed1349
更新日期:2010-09-01 00:00:00
abstract::Tibial shaft fractures distal to total knee arthroplasty are rare, but they are likely to become more common with the increasing number of arthroplasty procedures being performed. These fracture patterns have been treated in the past either with closed reduction and casting/bracing or with open reduction internal fixa...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000096
更新日期:2014-12-01 00:00:00
abstract:OBJECTIVES:To compare the abductor muscle function and trochanteric tenderness in patients operated with hemiarthroplasty using the direct lateral (DL) or posterolateral (PL) approach for displaced femoral neck fracture. DESIGN:Prospective cohort study. SETTING:A secondary teaching hospital. PARTICIPANTS:We enrolled...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000532
更新日期:2016-06-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to evaluate forearm rotation after volar plating of the distal radius fractures with and without pronator quadratus repair. DESIGN:This was an institutional review board-approved retrospective review of prospectively collected data. SETTING:The study was conducted at an Academ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3182539333
更新日期:2013-03-01 00:00:00
abstract:OBJECTIVES:For intramedullary nailing of tibial shaft fractures, a recent study has determined that the entry site should be just medial to the lateral tibial spine at the anterior margin of the articular surface. Gaining access to this site is often through a medial parapatellar or transpatellar approach. Several stud...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200211000-00001
更新日期:2002-11-01 00:00:00
abstract:OBJECTIVES:To determine whether there is a patient-reported functional difference between combat-related knee disarticulations (KDs) and transfemoral amputations (TFAs). SETTING:Role 3 Military Trauma Centers. PATIENTS:We identified and contacted all KDs and TFAs performed at the Walter Reed National Military Medical...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001440
更新日期:2019-06-01 00:00:00
abstract:PURPOSE:There are an estimated 1.2 million deaths from road traffic injuries annually, disproportionately affecting patients in low-resource settings. The purpose of this scoping review is to identify knowledge gaps in global orthopaedic trauma in an effort to help prioritize future research. METHODS:Using the 6-stage...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000001293
更新日期:2018-10-01 00:00:00
abstract::The development of a strong trauma program is clearly one of the most important facets of successful business development. Several recent publications have demonstrated that well run trauma services can generate significant profits for both the hospital and the surgeons involved. There are many aspects to this task th...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000142
更新日期:2014-07-01 00:00:00
abstract:OBJECTIVE:To evaluate the difference in quality of fracture reduction between the sinus tarsi approach (STA) and extensile lateral approach (ELA) using postoperative CT scans in displaced intra-articular calcaneal fractures (DIACFs). DESIGN:Retrospective SETTING:: Level 1 and Level 2 academic centers. PATIENTS:Consec...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001971
更新日期:2020-09-18 00:00:00
abstract:OBJECTIVE:To determine if a dual-purpose bone graft can regenerate bone and reduce infection in highly contaminated bone critical size defects in rats. METHODS:Biodegradable polyurethane (PUR) scaffolds were loaded with recombinant human bone morphogenetic protein-2 (BMP-2) and vancomycin (Vanc). The release kinetics ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31821f624c
更新日期:2011-08-01 00:00:00
abstract:OBJECTIVES:To investigate whether rotational malalignment of tibia, after fracture management with minimally invasive plate osteosynthesis technique (MIPO), leads to impaired results in knee and ankle joint functional scores. DESIGN:Prospectively collected data was retrospectively analyzed for this study. SETTING:Lev...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000002053
更新日期:2020-12-31 00:00:00
abstract:OBJECTIVE:The purpose of this study was to examine the results of computed tomography angiography (CTA) obtained in patients with high-energy tibial plafond fractures and assess if the information gleaned from CTA could be useful to the treating orthopedic surgeon. DESIGN:Consecutive patient series. SETTING:Level 2 t...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31815cf6e9
更新日期:2008-01-01 00:00:00
abstract::A unique case of an irreducible fracture dislocation of the knee is reported. A review of the literature revealed no previously reported cases of fracture dislocation of the distal femur not amenable to closed reduction. ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/00005131-199607000-00013
更新日期:1996-01-01 00:00:00
abstract::The ability of calcium phosphate cement (CPC) to reinforce cancellous screws placed in previously stripped holes was studied in vitro. The distal end of canine femurs were harvested. A total of 15 screws were placed in six femurs. The pullout strength (failure force), failure displacement, stiffness, and energy absorb...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199601000-00003
更新日期:1996-01-01 00:00:00
abstract:OBJECTIVES:To determine how often preoperative testing is requested for geriatric hip fracture patients, to assess the extent to which preoperative testing is associated with delayed surgery, and to measure the frequency with which preoperative testing changes patient management. DESIGN:Retrospective. SETTING:Academi...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000444
更新日期:2016-02-01 00:00:00
abstract:OBJECTIVES:To compare the results between a new intramedullary Gamma nail and a compression hip screw in the treatment of trochanteric fractures. DESIGN:Prospective randomized. SETTING:Level 1 trauma center. PATIENTS:Two hundred ten consecutive patients older than 65 years with trochanteric femoral fractures. INTER...
journal_title:Journal of orthopaedic trauma
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/01.bot.0000151819.95075.ad
更新日期:2005-04-01 00:00:00
abstract:OBJECTIVES:To document the high failure rate of a specific implant: the Synthes Variable Angle (VA) Locking Distal Femur Plate. DESIGN:Retrospective. SETTING:Urban University Level I Trauma Center. PATIENT/PARTICIPANTS:All distal femur fractures (OTA/AO 33-A, B, C) treated from March 2011 through August 2013 were re...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000391
更新日期:2016-01-01 00:00:00
abstract::Fracture compression can be achieved in many ways intraoperatively using either screws in compression plates, compression devices, or using intramedullary nails. The use of locked intramedullary nails combines the advantages of indirect fracture fixation and compression with minimal soft tissue disruption. This articl...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0b013e31819f2779
更新日期:2009-05-01 00:00:00
abstract:OBJECTIVE:To describe a novel approach for the treatment of nonunions of diaphyseal femur fractures. DESIGN:Retrospective review. SETTING:University hospital. PATIENTS:Seven patients (six men, one woman, average age 42.5 years) with diaphyseal femoral fracture nonunions treated between November 2006 and November 200...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181dfbb33
更新日期:2011-02-01 00:00:00
abstract::Antegrade intramedullary nails are an established, effective method of fixation for humeral shaft fractures. One significant limitation of this technique is chronic postoperative shoulder pain, which is likely related to the standard approach that involves splitting the rotator cuff to gain access to the nail starting...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000684
更新日期:2017-02-01 00:00:00
abstract::Orthopaedic surgery and biomechanics are intimately partnered topics in medicine. Biomechanical principles are used to design implants and fashion treatment protocols. Although it would seem that biomechanical principles in the design of fixation devices and fracture repair constructs have been already finalized, ther...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000001126
更新日期:2018-03-01 00:00:00
abstract::To evaluate the biomechanical and clinical results of modified separate vertical wiring technique (SVW) for inferior pole patellar fracture repair we conducted a finite element biomechanical study using 2 fixation methods and evaluated a clinical series of eleven patients. The modified SVW technique was an effective, ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001080
更新日期:2018-04-01 00:00:00
abstract:OBJECTIVES:To investigate the clinical and functional outcome in an elderly population with acetabular fractures after low-energy trauma treated acutely with a total hip arthroplasty supported by a reinforcement ring (Burch-Schneider antiprotrusion cage) and autologous bone grafting of the acetabulum. SETTING:Universi...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200303000-00007
更新日期:2003-03-01 00:00:00
abstract:OBJECTIVES:The increasing number of fractures of the proximal humerus, especially in the elderly, carries with it the unsolved problem of the optimal treatment for the displaced or unstable fractures. The authors' goal was to analyze whether fixation with a bent valgus angled blade plate could improve the outcomes repo...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200604000-00004
更新日期:2006-04-01 00:00:00
abstract::An 80-year-old man sustained a T-shaped supracondylar fracture of the femur associated with distal one-third shaft comminution. Initial failure of a 95 degrees angle blade plate was followed by insertion of an intraarticular intramedullary nail stabilized with static locking-screw fixation. A second failure of the imp...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199308000-00004
更新日期:1993-01-01 00:00:00